MIRA fire alarm control panel provides a cost effective platform for a fire alarm system that is
Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, MIRA offers an out of the box and on the wall solution.
Microprocessor controlled, user friendly design
-Reliable wide operating Voltage SMPS suitable for Indian
Power Conditions
-Operates from Single 12V, 7AH SMF Battery to save cost
-Regulated 24V for reliable Smoke Detector Operation
-Standby Battery backup with CC/CV Battery Charger
-Battery Low Voltage Cut-off to extend battery life
-Drives upto 4 Hooters
-Independent Potential free relays for Fire and Fault
SureFIRE fire alarm control panel provides a cost effective platform for a fire alarm system that is
Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, SureFIRE offers an out of the box and on the wall solution.
Microprocessor controlled, user friendly design
-16 Zones of Input
-Reliable wide operating Voltage SMPS suitable for Indian Power Conditions
-Regulated 24V for reliable Smoke Detector Operation
-Standby Battery backup with CC/CV Battery Charger
-Battery Low Voltage Cut-off to extend battery life
-Drives upto 16 Hooters
-Independent Potential free relays for Fire and Fault
-Ethernet Connectivity
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be
Connected to non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require
Special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
86722 Fire Alarm Control Suppliers
Short on time? Let Fire Alarm Control sellers contact you.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
One man detector test
Zone isolate
Revert to short-circuit: fire (no resistors in call points)
External indicators:
Sounder fault
Battery/power supply fault
Mains on
Zone fire
Zone fault
Internal indicators:
Open circuit zone fault
Short circuit zone fault
Zone isolated
Engineer test selected
Outputs:
Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
Repeater panels
Multiple sounder outputs
Connection to landlord panel
Mn/300/100 fire alarm control panel
Overview
The mn300 is a new type of analog fire alarm control panel which has 100 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses). It complies with the provisions of both fire alarm control units (gb4717-2005) and automatic control system for fire protection (gb16806-2006).
Features
1 the intelligent detectors and the intelligent modules have internal microprocessors to realize digital filtering and auto-compensation functions; the data collection is true and reliable; the mn300 control panel can carry out data processing based on fuzzy control theory and modern fire alarm theory to fundamentally avoid missing alarms and to reduce false alarms, so as to improve reliability.
2 the detectors have a sensitivity setup function and can adjust the alarm sensitivity according to the specific environment and their influences.
3 the detecting bus and the control bus share a two-wire structure and have non-polarity and fully mixed coding of the detectors and modules, and the intelligent detectors and the intelligent modules can be directly connected to them, which greatly simplifies the system wiring, engineering installation and circuit maintenance.
4 the system uses an ac-dc master-standby power supply system which will automatically change between the master and standby power supplies in the event of a power failure of either of the two power supplies to ensure uninterrupted operation of the system.
5 the mn300 can be connected to a special mini-printer to realize real-time printing.
6 the mn300 can be connected to floor fire display panels to display fire alarms by standard rs-485
7 the mn300 can be connected to ten multi-line linkage control/monitoring points to control and monitor important equipment.
8 the mn300 is equipped with eight bus manual control points, which makes it very easy for the user to control related equipment.
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected
To non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that
Require special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive)."
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Conventional Fire Alarm Control Panel with four Zones
2. Specifications
Two Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
One built-in Fire Fighting Ouput.
24-volt operation.
Resettable four-wire smoke detector power 500 mA.
Non-resettable power 500 mA.
One-man walk-test programmable for silent or audible test.
Disable/Enable control per IDC.
Reverse polarity protection.
3. Packaging and shipping
Conventional Fire Alarm Control Panel with four Zones
1 pc/carton box;carton M:43*17*51cm
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
Fire guard manufactures a wide range of fire control panels and accessories. From the newly launched conventional 2-8 zone conventional control unit to the highly capable analogue addressable panels.
Conventional Fire Alarm Control Panel /Security Alarm Host/ Master Control Panel
Products Features
4,8,16 Class B Initiating Device Circuits (IDCs)
All zones accept conventional detectors and any normally open contact device
Four Class B Notification Appliance Circuits (NACs)
One Form-A Alarm Relay
One Form-A Trouble Relay
One Form-A Supervisory Relay
3.0 amps of system power
Max 30 conventional detectors
in one zone.
Auto/Manual mode setting enable walk test.
Each Zone can be disabled,
Sound output can be disabled.
Manual active sound output enabled.
Able to report short and broken circuit of detection zones.
Designed with standby batteries and space provision for two sealed lead-acid batteries.
Testing and disable functions.
Can connect max 32 repeater panels by RS485 communication port
Dimensions : 14.57 " (37 cm) long X 17.32" (44 cm) high X 3.94"(10cm).
Weight: 6.6kg (without battery).
Specifications
AC Power
90-270 VAC, 50 Hz, 2.3 amps
Wire size: minimum #14 AWG (2.0 mm 2 ) with 600V insulation
Battery (lead acid only)
Maximum Charging Circuit: Normal Flat Charge27.6V @ 0.8 amp
Maximum Charger Capacity: 18 Amp Hour batter
Sound Output Device Circuits
General Alarm Zones 1 through 16
Operation: All zones Class B
Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
Alarm Current: 15 mA threshold
Short Circuit Current: 42 mA maximum
Maximum Loop Resistance: 100 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
Standby Current: 7.26 mA
Three Relays Output
Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)
Nonresettable 24 VDC Power
Maximum ripple voltage: 10 mV RMS Operating Voltage nominal 24 volts
Total DC current available from this output is up to 500 mA
Recommended maximum Standby current is 150 mA
The mini 2 zone panel HS-CK1002 have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
2. Specifications
Item No.
HS-CK1002
HS-CK1004
HS-CK1008
HS-CK1016
Zones
2
4
8
16
Sound output
1
1
2
4
AC power
220VAC/50Hz
220VAC/50Hz
220VAC/50Hz
220VAC/50Hz
Battery
Sealed lead-acid only
Total DC24V system power
3.0 amps
Max current per NAC
1.25amps
Max battery charging capability
18AH
Cabinet weight(net/gross)
3.5/4kg w/o battery
6.0/6.6kg w/o battery
6.0/6.6kg w/o battery
6.0/6.6kg w/o battery
3. Features
our Style B (Class B) Initiating Device Circuits (IDCs).
One Master Panel also has two zones, each zone can connect max.25 conventional detectors.
One slave Panel has two zones, each zone can connect max.25 conventional detectors.
The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
Power Supply: AC 240V 50/60Hz
Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery
Charging Voltage: DC26.4V Below 450mA Trickle Charging
Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA
Loop Resistance: Below 50+ back and forth
Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A)
Terminal Resistor: 10k+
Number of indicators: 1 time the number of panel circuits
Number of Local Alarm: 1 time the number of panel circuits.
Number of circuit & Dimension:
1L/2L/4L/5L/8L (330x280x120mm)
12L/16L(400x300x120mm)
24L(495x300x120mm).