Conventional Fire Alarm Contol Panel

Supplier From Taiwan
Dec-07-10

Power Supply: AC 240V 50/60Hz
Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery
Charging Voltage: DC26.4V Below 450mA Trickle Charging
Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA
Loop Resistance: Below 50+ back and forth
Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A)
Terminal Resistor: 10k+
Number of indicators: 1 time the number of panel circuits
Number of Local Alarm: 1 time the number of panel circuits.


Number of circuit & Dimension:
1L/2L/4L/5L/8L (330x280x120mm)
12L/16L(400x300x120mm)
24L(495x300x120mm).

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Conventional Fire Alarm Contol Panel

Mar-28-19
 
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Mar-28-19
 
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Mar-28-19
 
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Dec-26-17
 
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel

Product Features

1. 2 conventional input zones.
2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex.

3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Nov-28-16
 
1. General

Conventional Fire Alarm Control Panel with four Zones
2. Specifications



Two Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
One built-in Fire Fighting Ouput.
24-volt operation.
Resettable four-wire smoke detector power 500 mA.
Non-resettable power 500 mA.
One-man walk-test programmable for silent or audible test.
Disable/Enable control per IDC.
Reverse polarity protection.


3. Packaging and shipping

Conventional Fire Alarm Control Panel with four Zones
1 pc/carton box;carton M:43*17*51cm
Oct-20-16
 
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
Nov-22-16
 
1. General

HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
Dec-26-17
 
Conventional fire alarm smoke detector smoke probe sensor

This device is photoeletronic detector uses a state-of-the-art optical sensing chamber.

This smoke detector is compatible with all conventional fire alarm control panel

Dual leds, two leds blink standby, provide 360dgree visibility

With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources.

Unpolarized wire input to prevent the likelihood of wiring errors
Specifications

Operating voltage range: 9 to 28vdc volts non-polarized

Standby current: 60µa @ 24 vdc

Maximum alarm current (led on: ) 30ma @ 24 vdc

Operating humidity range: 10% to 93% relative humidity, non-condensing

Operating temperature range: 14°f to 122°f (-10°c to50°c)

Adjustable sensitivity: 0.15ï½?0.3db/m

Height: 2.2ë� (55 mm) installed in base

Diameter: 4.0ë� (103 mm)

Weight: 5.5 oz. (155 g)
GOLD Member
May-13-20
Supplier From Garfield Heights, Ohio, United States
 
We just processed in a large batch of chipsets. I posted below current inventory and attached pictures of each type of chipset. Please review and let me know your interest/offer.

Chipset 1 (H61) â?? 3,350 units
Chipset 2 (H81) â?? 2,206 units
Chipset 3 (H55) â?? 436 units
Chipset 4 (B250) â?? 1,600 units
Chipset 5 (SR406) â?? 345 units


Thank you,

Divanti Group

Verification Status