Supplier : Conventional and addressable smoke detector, gas detector, heat detector, flame detector, fire alarm control panel, bells, manual call point, sounder strobe, beam detector
Established: 2013
Standards: ISO9000
Verification Status
Contact Details:
4f, Building B1, Xinhaosheng High-tech
Shenzhen
518103
Guangdong
China
2-wire DC powered Conventional Manual Call Point Push Button
The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.
Specifications:
A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner
Fire alarm.
A705/IR2 is converted to electrical si gnal by two infrared pyroelectric sensors which work in different bands.
Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time.
A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time
In the indoor, outdoor and all kinds of special industrial places.
Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor
Optical window ï¼?white gems (Al2O3)
housing
L material: aluminum alloy
L molding process: Die Casting
L coating process: surface electrostatic powder coating, internal metal passivation treatment.
The weight is less than 1kg
Explosion proof and protection l anti explosion: EXd II CT6
The conventional manual call point designed for
conventional fire alarm system for reporting fire or
emergency condition by pull down the plate. The
manual call point can be reset by a special key
without breaking the glass.
Features
1. Compatible with all the conventional fire alarm control panel
2. Can be reset by key without use a new glass
3. 470 Ohm resistance
4. Easy surface mounting Base included
Specifications
Operating Voltage Range: 9 to 28VDC Volts
Alarm Resistance 470ohm/1W
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: Length 140mm, Width 105mm, Depth 45mm
Weight: Net Weight 220g
3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
2-wire Conventional Sound Strobe Fire alarm Sound Siren
The Sounder strobe is a kind of audible and visual alarm
device installed in field, which can be activated by fire
alarm control panel in fire control center or by manual
call point installed in field. After activated, it will
generate strong audible/audible and visual alarm signal to
warn people in field.
Features
1. Compatible with all the conventional fire alarm control panel
2. Long light life up to 40000 flahsed
3. High sound level up to 100dB
Specifications
Working voltage: 16VDC to 30VDC.
Alarm Current: â?¤ 50mA.
Ambient temperature: -10â?? to +55â??.
Ambient humidity: â?¤95%RH.
Sound level of alarm : â?¥100dB.
Flash Intensity: â?¥75CD
Flash Period: 40000times
Dimensions: 133mmÃ?115mmÃ?50mm
L Ã?WÃ?D(With base)
Weight: 141g
Key specifications/special features
Power source: 9 v battery (included).
Audio alarm: & g e; 85 db /3 m
Temperature range: 0 to 40 degree
Humidity range: 5%-95% relative humidity(rh)
Sensor: photoelectric
Size: diameter 105 mm in diameter x59 mm depth
Interconnects: no
Easy to install with mounting base included
Suitable for any room
Low battery signal
Test button for simple testing
The Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real
user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount
mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between
the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in
alignment commissioning.
The beam detector has four adjustable operational range of between 8 to 20, 40, 70 and 100 meters beside
with three adjustable sensitivity setting ranges from 2.6dB to 4.8dB to meet the specific environmental
requirement. The detector works on the principle of reflective infrared beam obscuration. Used in conjunction
with a reflectors, it will notify the fire alarm panel when the infrared beam is obscured by smoke. Secure and
quick communication through the onboard processor enables the detector to make its own decision and drift
compensation resulting in greater automation.
The detector is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls,
leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well
as places where slight smoke particles or corrosive gas exist.
Feature and Benefits
1. Manufacture in compliance with EN54-12
2. Hassle free alignment, built with digital guide display and laser beam pointing
3. Employ single-ended design through reflective mirror.
4. Four ranges wide monitoring from 8-100 meters via encoder
5. Three users programing sensitivity adjustment
6. Built-in microprocessor
7. Self-diagnosis function can monitor for internal faults
8. Automatic compensation for factors weakening received signals, such as dust contamination, positional
movement and ageing of the transmitter
9. Fire and Fault interfacing relays
10. Attractive and pleasing appearance
11. Real User friendly alignment method