Mn/300/100 fire alarm control panel
Overview
The mn300 is a new type of analog fire alarm control panel which has 100 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses). It complies with the provisions of both fire alarm control units (gb4717-2005) and automatic control system for fire protection (gb16806-2006).

Features
1 the intelligent detectors and the intelligent modules have internal microprocessors to realize digital filtering and auto-compensation functions; the data collection is true and reliable; the mn300 control panel can carry out data processing based on fuzzy control theory and modern fire alarm theory to fundamentally avoid missing alarms and to reduce false alarms, so as to improve reliability.
2 the detectors have a sensitivity setup function and can adjust the alarm sensitivity according to the specific environment and their influences.
3 the detecting bus and the control bus share a two-wire structure and have non-polarity and fully mixed coding of the detectors and modules, and the intelligent detectors and the intelligent modules can be directly connected to them, which greatly simplifies the system wiring, engineering installation and circuit maintenance.
4 the system uses an ac-dc master-standby power supply system which will automatically change between the master and standby power supplies in the event of a power failure of either of the two power supplies to ensure uninterrupted operation of the system.
5 the mn300 can be connected to a special mini-printer to realize real-time printing.
6 the mn300 can be connected to floor fire display panels to display fire alarms by standard rs-485
7 the mn300 can be connected to ten multi-line linkage control/monitoring points to control and monitor important equipment.
8 the mn300 is equipped with eight bus manual control points, which makes it very easy for the user to control related equipment.

Price and Minimum Quantity

Price: $758
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Addressable Fire Alarm Control Panel

Oct-20-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected
To non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that
Require special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Nov-28-16
 
1. General

Conventional Fire Alarm Control Panel with four Zones
2. Specifications



Two Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
One built-in Fire Fighting Ouput.
24-volt operation.
Resettable four-wire smoke detector power 500 mA.
Non-resettable power 500 mA.
One-man walk-test programmable for silent or audible test.
Disable/Enable control per IDC.
Reverse polarity protection.


3. Packaging and shipping

Conventional Fire Alarm Control Panel with four Zones
1 pc/carton box;carton M:43*17*51cm
Aug-23-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm

System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be

Connected to non-addressable devices when used with addressable input modules.

Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile

Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require

Special operating features.

The 6001 comes standard with features that allows flexibility and expandability.

Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Nov-22-16
 
1. General

HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
Nov-22-16
 
1. General

HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.

2. Specifications

Name
6" Alarm Bell
Item No.
HS-JL188-6
Operating voltage
DC24V
Alarm current
70mA @ DC24V
Alarm sound intensity
Minimum 95dB
Dimension
Diameter 155mm, height 45mm
Weight
650g
Features
Easy to install bracket


3. Features

Operating Voltage : DC24V

Alarm Current: Maximum 70 mA

Alarm Sound Intensity: Minimum 95dB
Nov-30-16
 
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc.

1. Specifications

a. Four Style B (Class B) Initiating Device Circuits (IDCs).
b. All zones accept two-wire smoke detectors and any normally-open contact devices.
c. One built-in Fire Fighting Ouput.
d. 24-volt operation.
e. Resettable four-wire smoke detector power @ 500 mA.
f. Non-resettable power @ 500 mA.
g. One-man walk-test programmable for silent or audible test.
h. Disable/Enable control per IDC.
i. Reverse polarity protection.
Nov-28-16
 
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response.
It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored.
The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
Oct-20-16
 
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
May-06-16