Product synopsis
Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing.
Model: CM8829S
With separate probe(s)
Operating principle: magnetic induction/eddy current (F/NF)
Measuring range:0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: í+1-3%n or í+2.5um
Min. measuring area:6mm
Min. sample thickness:0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4x1.5V AAA(UM-4)battery
Auto power off
Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH
Dimensions: 126x65x27mm
Weight: 81g(not including battery)
Application:
Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep.
Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation.
Specifications:
Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz )
Velocity : 0.1-200mm/s0. (10Hz to 1KHz)
Displacement: 0.001-2.0mm(10Hz to 1KHz)
Accuracy:·+5¼t
Auto power off
Max hold
Operating conditions:0-+40f¦(32+H-104+H),f_90%RH
Power supply: 4x1.5V AA(UM-3)battery
Battery indicator: low battery indicator
Dimensions : 160x68x32mm
Weight: 181g(not including battery)
Features
Used in production site to measure surface roughness of various machinery-processed parts, calculate corresponding parameters according to selected measuring conditions and clearly display all measurement parameters.
Specifications
Displayª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz
Display Range
Ra: 0.05-10.00um/1.000-400.0uinch
Rz: 0.020-100.0um/0.780-4000uinch
Accuracy: Not more than 10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 10um
Material of Probe Pin: Diamond
Measurement Force of Probe: 16mN(1.6gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 1~5 cut off optional
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Resolution : 0.001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0-50f¦
Humidity <80%
Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface
Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
25 Electronic Meters Suppliers
Short on time? Let Electronic Meters sellers contact you.
Features
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.
When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate
Specifications
Display·ª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz, Rq, Rt
Measuring Range
Ra, Rq: 0.005-16.00um/0.020-629.9uinch
Rz,Rt: 0.020-160.0um/0.078-6299uinch
Accuracy: f_f+10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 5um
Material of Probe Pin: Diamond
Dynamo-measurement of Probe: 4mN(0.4gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 5l
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Profile digital filter
Filtered Profile: RC
Filtered Profile: PC-RC
Filtered Profile: Gauss
Non-Filtered Profile: D-P
Resolution : .001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Evaluation length : 5 cut-off
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0~50f¦
Humidity <80%
Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface
Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
Product synopsis
Model: HM-6561
Typical Applications
Die cavity of molds
Inspection of bearing and other mass produced parts on a production line
Failure analysis of pressure vessel, steam generator and other equipment
Inspection of installed machinery, permanent parts of assembled systems and heavy work pieces.
Testing surface of a small hollow space
Material identification in the warehouse of metallic materials
Rapid testing in large range and multi-measuring areas for large-scale work piece
Testing Features
Palm size for narrow space.
Test at any angle, even upside down.
Direct display of hardness scales HRB, HRC, HV, HB, HS, HL.
Large memory could store 250 groups including single measured value, impact direction, material and hardness
scale etc.
User recalibration function allowed.
Can communicate with PC computer for statistics and printing by the optional cable.
Manual or automatic shut down.
Low battery indication.
Technical Specifications
Display: 12.5mm LCD with back light
Accuracy: Display error í+0.8% at LD=900
Measuring range: 200-900L
Conversion: HL-HRC-HRB-HB-HV-HSD
Materials: 9 different common materials
With RS232C interface
Memory: 250 data can be stored and re-readable
Impact device: D Will handle the majority of hardness testing applications. Weight: 75g
Power supply: 2x1.5V AAA size battery
Working temperatureú¦ - 10íµí½ú½50íµ
Storage temperatureú¦- 30íµí½ú½60íµ;
Relative humidity: í_90úÑ
Dimension: 146í-65í-36mm
Weight: 130g (not including batteries)
Specification
60 groups memory function.
Average function for last 3 times measurement value.
Fuzzy Logic technology.
Arrhythmia detection function (IHB).
Automatically inflate and deflate.
Automatic power-off function.
Power: 4 AA size alkaline batteries.
Measurement Range: Pressure: 0mmHg~299mmHg; Pulse: 40~200 times/min.
Measurement Accuracy: Pressure: +/- 3mmHg; Pulse: +/- 5% of reading.
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc.
Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h
LCD 3-1/2 LCD display
Dimension Width *length* thick·ª92mmf-192mmf-50mm
LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm
Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼
Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V
resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V
Measurement accuracy
·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp
current·ªf+1%f+2dgt
Voltage·ªf+1.2%f+2dgt
line voltage Line test under AC500V
Sampling speed About 3 times /s
Signal frequency sine wave 45Hz~55Hz ¬-=0.05
Data hold Data holding function·ªdisplayed by fªDHfª symbol
Back light function Blue back light ,suit for dark occasion
Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption
Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery;
Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g
Work temperature and moisture -10f¦~40f¦·+85%rh below
Storage temperature and moisture -20f¦~60f¦·+70%rh below
Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+
Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼
Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input.
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameter. When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of
Inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier. The exclusive dsp processes and calculates and then
Outputs the measurement results on lcd.
* multiple parameter measurement: ra, rz, rq, rt
* highly sophisticated inductance sensor
* four wave filtering methods : rc, pc-rc,
Gauss and d-p
* built-in lithium ion chargeable battery and control
Circuit with high capacity
* small in size, light in weight and easy to use
* can communicate with pc computer for statistics,
Print and analyz by the optional cable and the
Software for rs232c interface.
*manual or automatic shut down. The tester can be
Switched off by pressing the power key at any time.
On the other hand, the tester will power itself off
About 5 minutes after the last key operation.
Eatures:
Measuring rpm is safe & accurate without attachment to object.
Wide measuring range & high resolution.
Digital display gives exact rpm with no guessing or errors.
Used the exclusive micro-computer lsi-circuit and crystal time base to offer the high accuracy measurement & fast measuring time.
The last value/max. Value/min. Value will be automatically stored in memory and can be displayed by turn.
The use of durable, long-lasting components, including a strong, light weight abs-plastic housing assures maintenance free performance for many years.
Product synopsis
Model: dt
Measuring range: rotative velocity laser . - r/min
Contact . - r/min
Laser tach detecting distance: - mm
Accuracy: f+( . %n+ d)
Resolution: . / . /
Memory: max/min/last value
Power supply: x . V aa (um- ) battery
Battery indicator: low battery indicator
Dimensions: x x mm
Weight (not including probe): g