Please click here to check who's online and chat with them.

Double Clamp Digital Phase Meter

Supplier From China
May-26-09

Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc.
Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h
LCD 3-1/2 LCD display
Dimension Width *length* thick·ª92mmf-192mmf-50mm
LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm
Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼
Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V
resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V
Measurement accuracy
·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp
current·ªf+1%f+2dgt
Voltage·ªf+1.2%f+2dgt
line voltage Line test under AC500V
Sampling speed About 3 times /s
Signal frequency sine wave 45Hz~55Hz ¬-=0.05
Data hold Data holding function·ªdisplayed by fªDHfª symbol
Back light function Blue back light ,suit for dark occasion
Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption
Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery;
Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g
Work temperature and moisture -10f¦~40f¦·+85%rh below
Storage temperature and moisture -20f¦~60f¦·+70%rh below
Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+
Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼
Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input.




92*192*50(mm)

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Double Clamp Digital Phase Meter

GOLD Member
VERIFIED
Nov-21-20
Supplier From New Delhi, Delhi, India
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
Jan-11-10
 
Three Phase Double Tariff Meter (DTS353)
Executive Standard: IEC62052-11 2003; IEC62053-21 2003
DIN-rail standard: "SO"43864.

Function and characteristic:
Two tariffs; Double LCD;
Control tariff by exterior controller;
Two display window for two different tariffs T1, T2.

Technical data:
Rated Voltage: 3*220V/380V; 3*230V/400V
Rated Current: 3*5(30)A; 3*10(60)A; 3*10(100)A
Frequency: 50-60Hz
Connection Mode: Direct type
Display: LCD 5+1=99999.9kWh
Accuracy Class: 1.0;
Power Consumption: Less than 0.6W; Less than 0.3VA
Start current: 0.004Ib
Constant: 800/1600/3200/6400imp/kWh.


Size: 122*100*65mm.
GOLD Member
VERIFIED
Apr-06-21
Supplier From Jamnagar, Gujarat, India
 
we are leading manufacturer & exporter of standoff/spacers as per requirement or Drawing
Jan-11-10
 
Single Phase kWh Meter
Executive Standard: IEC62052-11 2003; IEC62053-21 2003

Function and characteristic:
Infrared function;
Measurement accurately.

Technical data:
Rated current: 1.5(6)A 5(30)A 10(40)A 5(60)A 20(80)A
Rated voltage: 110V 220V 230V 240V
Display mode: LCD 6+1=999999.9kWh
Accuracy class: 1.0
Frequency: 50Hz (60Hz)
Impulse constant: 800/1600imp/kWh
Connetion mode: CT type; Direct type.



Size: 153*118*50mm.
Apr-26-17

Clamp-On Ultrasonic Flow Meter

$800
MOQ: Not Specified
Supplier From Shanghai, Perak, China
 
The RBBF Clamp-on Ultrasonic Flow Meter is a fixed-mount, low cost transit-time ultrasonic flow meter with clamp-on transducers for non-invasive liquid flow rate measurement. Our microprocessor-based, user friendly field programmable creates no interruption of the process flow and has low installation costs.

This versatile series of flow meters is available in a variety of configurations. Available transducer types include clamp-on, in-line, and insertion. Wall-mount, panel-mount, pipe-mounted and compact din-rail mounted display types are also offered. Additional available features include pulse, 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function.
May-15-14
Supplier From Busan, South Korea (Republic Of Korea)
 
Weight Measurement Function: By Hours, minutes and seconds unit, Display the status of the usage of liquid gas and it can be used being installed on storage tank or tank lorry and can be carried as a portable measuring instrument.
PC Monitoring Function: As the remained liquid goes below 10% of its capacity, it automatically alarms to supplement liquid gas. Thus, the appropriate time for supplement of liquid gas can be decided on time.
Alarm Function: the liquid remaining of the storage tank is less than 10%, The alarm sound provides information that you can setting the a liquid supply time.
Diversity Of Power Supply: Use the usual 220volt electric, in case of power outage, the built-in battery will supply the charged electricity, in addition built-in battery is operated and available for tank lorry using the car battery.

Option (Printer : additional purchase): Receipt Output Function; Portable thermal transfer printer can use the output value measuring of storage tank and tank lorry without visiting a long measuring place directly by the output as a receipt.
Mar-09-10
 
Xl5135v-1 ac220v power supply--measuring dc voltage--voltmeter

Technical index:

Digit display: 1999

Operating temperature:0~40

Relative humidity:20%~80%

Power supply:ac220v

Installation method:inlay

Tapping size:76 x 39 (mm)

Dimension: (w) 79mm x (h) 42.5mm x (d) 25.5mm

Resolution: 10mv

Input impedance: 100mª+

Max. Input voltage:ía10v

Full range:ía199.9mv.
Mar-05-09
 
1.General
PZ96 Series power analyzer specializes in measuring the data of all kinds of AC networks, such as the currents, the voltages, the powers, the energies etc... It may be used for local display, or it is connected with the control equipment in measuring and controlling system.
They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication with Modbus-RTU protocol; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely
They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system.

2.Technical feature
- Input
Network: Single-phase network; 3-phase balanced network, 3-phase unbalanced, 3 wires; 3-phase unbalanced, 4 wires
Measurable: 26 parameters (3I, 6U, F, 4P, 4Q, 4cos, 4E)
Frequency: 45í½65Hz
Voltage: AC 100V, 400V (programmable); Overload: 480V (continuous), 800V/30s; Consumption: < 0.2VA
Current: AC 1A, 5A (programmable); Overload: 6A (continuous), 50A/30s; Consumption: < 0.2VA
Thermal drift: <200ppm
Transformation ratio: Programmable
- Power supply: AC/DC 85í½270V; Consumption í_ 4VA
- Test voltage: 2kVAC/min (voltage input / power; between current inputs); 1.5kVAC/min (outputs / power)
- Insulation: input / housing and output / housing >100Mª+
- Environment
Work T: -10Cí½+45C
Storage T: -20Cí½+70C
Relative humidity: 5%í½95% (no condensation)
Altitude: í_2500m

3.Options
- Display (L): LED or LCD display, the brightness can be set
- Communication (/C): RS485 (Modbus-RTU); 1 start bit, 8 data bit, 1 stop bit, no parity, speed
(1200/2400/4800/9600/19200)
- Alarm output(/J): 1 passive relay (1A/30VDC, 1A/250VAC); alarms of over voltage, low voltage and over current;
The hysteresis and the delay can be set
- Analog output(/M): DC4~20mA, DC0~20mA( load < 600ª+), DC0~5V,DC1~5V( load > 1kª+); Number: /M, /M3 (1 or 3
analog outputs)
- Logic options(/K)
4 logic inputs and 2 logic outputs
Logic Input: dry contact Input, supplied inside, optoisolator
Logic output: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments)
- Accuracy: 0.2
Note: /M and /K can not be chosen simultanously.

4. Specification
96 * 96 mm
PZ96-E3 3 Phase LED
PZ96L-E3 3 Phase LCD

72 * 72 mm
PZ72-E Single Phase LED
PZ72L-E Single Phase LCD

80 * 80 mm
PZ80-E Single Phase LED
PZ80-E3 3 Phase LED
PZ80L-E Single Phase LED
PZ80L-E3 3 Phase LCD

120 * 120 mm
PZ42-E3 3 Phase LED
PZ42L-E3 3 Phase LCD

144 * 144 mm
PZ144-E3 3 Phase LED

Verification Status