Please click here to check who's online and chat with them.

Find Verified Electric Meter Scrap Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Dongguan  
Dec-30-06
 
Features:
1, in accordance with iso 2372, used for periodic measurements, to detect out-of-balance, misalignment and other mechanical faults in rotating machines.
2, specially designed for easy on site vibration measurement of all rotating machinery for quality control, commissioning, and predictive maintenance purposes.
3, individual high quality accelerometer for accurate and repeatable measurements.
4, lcd digital display.
5, lightweight and easy to use
6, automatic power shut off to conserve power.
7, can communicate with pc computer for statistics and printing by the optional cable and the software for rs232c interface.


Dimensions : 160x68x32mm
Jan-10-07
 
Moisture meter mc-7825ps

Model: mc-7825ps
Meaning: pin ·¬ search type
Specifications: wood over 150 species
Building moisture: 0-50%
Measuring range: 0-80%
Resolution: 0.1
Display: lcd display
Accuracy: f+(0.5%n+0.1)
Power supply: 4x1.5v aaa (um-4) battery
Battery indicator: low battery indicator
Dimensions: 165x62x26mm
Weight (not including probe):175g

Dimensions: 165x62x26mm
Dec-30-06
 
Can measure the thickness of non-magnetic coating layers on magnetic substrate, such as: (aluminum, chrome, copper, enamel, rubber, plaint) on magnetic substrate(steel, iron, alloy and magnetic stainless steel), and can measure the thickness of nonconductive coating layers covered on nonferrous substrate, such as:(ename1, rubber, paint, vanish, plastic anodic-oxide layer) covered on nonferrous substrate(aluminum, brass, nonmagnetic stainless steel)
Model: cm-8820, cm-8821, cm-8822, cm-8823, cm-8825fn, cm-8825f, cm-8825n, cm-8826fn, cm-8826f, cm-8826n, cm-8829, cm-8829s.


Dimensions: 160x68x32mm
Oct-23-10
 
Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing.
Model: CM8825FN
In built probe(s)
Operating principle: magnetic induction/eddy current (F/NF)
Measuring range:0-1250um/0-50mil
Resolution; 0.1/1
Accuracy: í+1-3%n or í+2.5um
Min. measuring area: 6mm
Min. sample thickness: 0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4x1.5V AAA(UM-4)battery
Auto power off
Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH
Dimensions: 126x65x27mm
weight: 81g(not including battery)
Optional accessories: other range 0-200um to 15000um
RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface.
Feb-22-08
 
Optical power meter pop-560

Pop-560 power meter is the newest-generation handheld fiber optical tester. It can offer the
Best performance for the daily maintenance for fiber network, and cwdm system, dwdm
System and fttx network. The perfect test function and test ensurence are all ideal for
Indoor or field-testing.
Features:
The most perfect testing function:
1. Three kinds of modulated signal recognitiong270hzb1khzb
2khz
2. Auto-wavelength recognition, no need for communication
Between the sources and power meter. Save test time and
Decreases the potential error.
3. 21 calibrated wavelengths offered to meet the customersªtesting
Requirement. Such as fttx 1490nm.
4. The moveable connector provides several types of connector
Included fc, sc etc.
5. Superior testing range: -70dbm p +10dbm or -50dbm p
+26dbm
Nthe most perfect power supply and power management:
1. Internal rechargeable li batterybaa battery and ac adapter.
2. Auto power-off.
3. More than 200hr battery operating.
Nthe most perfect testing guarantee:
1. Superior stability to ensure the testing performance and repeatability.
2. Wide lcd display that provides the most complete testing information: wavelength,
Modulated signal, all kinds of conditions.
3. High quality and rugged design, ideal for field testing.
6304 Electric Meter Scrap Suppliers
Short on time? Let Electric Meter Scrap sellers contact you.
GOLD Member
Jun-18-24
Supplier From Guangzhou, Guangdong, China
Nov-27-14
Supplier From Guangzhou, Huangpu, China
Mar-07-16
Supplier From Guangzhou, China, China
Dec-22-06
Supplier From Guangzhou, China
Nov-17-10

Coating Thickness Meter

$100
MOQ: Not Specified
 
Product synopsis
Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing.
Model: CM8829S
With separate probe(s)
Operating principle: magnetic induction/eddy current (F/NF)
Measuring range:0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: í+1-3%n or í+2.5um
Min. measuring area:6mm
Min. sample thickness:0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4x1.5V AAA(UM-4)battery
Auto power off
Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH



Dimensions: 126x65x27mm
Weight: 81g(not including battery)
Nov-09-10
 
Acceleration 10Hz-1KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
10Hz-10KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
Velocity 10Hz-1K 0.1-400mm/s 0.004-16.0inch
Displacement 10Hz-1KHz 0.001-4.0mm 0.04-160 mil
Accuracy:++5%
Auto power off
RPM(revolution):5-100000r/min
Frequency:0.1 to 10KHz
Metric/imperial conversion
With RS232C interface
Max hold
Operating conditions:0-+45f+(32=¬-104=¬),f-90%RH
Power supply:4x1.5V AAA(UM-4)battery
Battery indicator: low battery indicator
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Dimensions : 124x62x30mm
Weight: 120g(not including battery)
Nov-10-10
 
Application:
Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep.
Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation.
Specifications:
Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz )
Velocity : 0.1-200mm/s0. (10Hz to 1KHz)
Displacement: 0.001-2.0mm(10Hz to 1KHz)
Accuracy:·+5¼t
Auto power off
Max hold
Operating conditions:0-+40f¦(32+H-104+H),f_90%RH
Power supply: 4x1.5V AA(UM-3)battery
Battery indicator: low battery indicator



Dimensions : 160x68x32mm
Weight: 181g(not including battery)
Nov-10-10
 
Specifications
Display: 4 digits LCD, backlit
Range: 0~1250 »m/0~50mil
(other ranges can be specified )
Min.radius workpiece: F: Convex 1.5mm/Concave 25mm
N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min.Sample thickness : 0.3mm
Resolution: 0.1 »m (0~99.9»m);
1 »m (over 100»m)
Accuracy: f+1~3%n or 2.5 »m or 0.1mil
(Whichever is the greater)
Bttery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50f¦ .
Humidity <95% .

Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Size: 126x65x35 mm; 5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
Nov-17-10
 
Wholesale PH Meter
Dec-13-06
 
Moisture meter mc7806

Model:
Moisture meter mc7806
Measurement range: moisture content 0-50%
Temperature +c10-60f
Resolution: 0.1
Accuracy:
Moisture: f+(0.5%n+0.1)
Temp: f+0.8f
Calibration: automatic
Power supply: 4x1.5v aa (um-3) battery
Dimensions: 182x68x38mm
Probe dimension: 170x44x25mm
Weight (not including probe):334g


Dimensions: 182x68x38mm
Probe dimension: 170x44x25mm
May-28-08
Supplier From Guangzhou, Guangdong, China
VERIFIED
Mar-07-14
Supplier From Guangzhou, Guangdong, China
May-26-09
 
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc.
Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h
LCD 3-1/2 LCD display
Dimension Width *length* thick·ª92mmf-192mmf-50mm
LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm
Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼
Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V
resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V
Measurement accuracy
·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp
current·ªf+1%f+2dgt
Voltage·ªf+1.2%f+2dgt
line voltage Line test under AC500V
Sampling speed About 3 times /s
Signal frequency sine wave 45Hz~55Hz ¬-=0.05
Data hold Data holding function·ªdisplayed by fªDHfª symbol
Back light function Blue back light ,suit for dark occasion
Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption
Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery;
Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g
Work temperature and moisture -10f¦~40f¦·+85%rh below
Storage temperature and moisture -20f¦~60f¦·+70%rh below
Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+
Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼
Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input.




92*192*50(mm)
Dec-14-06
 
Coating thickness meter cm-8823

Application:
Product synopsis
Measurement range
0200um/500um/1000um/15000um
Resolution
0.1/1
Tolerance
+(13%n) or +2um
Power supply
4x1.5v aa(um-3)battery


Dimension
161x69x32
Jun-16-17
 
Waterproof ph meter with backlight
Specifications
Range 0.0 to 14.0 ph
Resolution:     0.1 ph
Accuracy : ±0.01 ph
Typical emc deviation  ±0.1 ph
Calibration:  manual, 1 point,
Temperature compensation automatic: 0 to 50
Environment:  0 to 50 (32 to 122f);
Rh max 95%
Battery type   4 x 1.5v alkaline
Battery life approx. 200 hours of use
Dimensions 152 x 30 x 21 mm
(5.9 x 1.2 x 0.8")
Weight:     53 g

Operation
Remove the protective cap. Do not be alarmed if white crystals
Appear around the cap. This is normal with ph electrodes and
They dissolve when rinsed with water.
Turn the meter on sliding the switch on the top.
Immerse into solution up to the max immersion level.                                         ?¢ stir gently and wait until the display stabilizes. Readings are automatically compensated for temperature variations.
After use, switch off ph meter, use the water clean the electrode and replace the protective cap.
Do not use distilled or deionized water for storage purposes.
Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

Calibration
Immerse the tester up to the maximum immersion level in ph 6.86 buffer solution
Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.9.
Calibration is now complete.
Always use fresh buffers for calibration.
Battery replacement
When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5v batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.
6304 Electric Meter Scrap Suppliers
Short on time? Let Electric Meter Scrap sellers contact you.