Security alarm system, wireless alarm control panel, alarm host, wired burglar alarm host, security protection alarm, anti-theft alarm, panalarm, alarm control system,
8 wired &16 wireless zones multi-function alarm control panel, alarm host
Model: md-816(compatible with both wired and wireless)
Compatible with wired and wireless function
1 group 6 bits primary passwords, 15 groups subsidiary setting passwords are available to improve security;
6 groups of phone number and 3 group alarm center phone number could be set. When the alarm activated, it could repeat dialing the numbers.
8 arm modes: exit arm, boundary arm, single zone arm, delay arm, remote arm, compel arm , remote arm and preset time arm.
6 disarm modes: single zone disarm, keypad password disarm, long distance disarm, time disarm, remote setting disarm, disarm when connecting alarm.
8 zone modes: instant zone, delay zone, 24 hours zone, boundary zone , fire alarm zone, gas zone, check zone, and by-pass zone
Backlight Digital LCD Alarm Clock
Smart back-light: smart light(auto light at night) Auto on when into dark,when you put the clock into dark, it will light up by itself.
Dim brightness of backlight, with on/off of sensor for smart light
Light up when press the button, normal brightness different from smart light.
5 minutes repeating ascending snooze alarm,with on/off setting of snooze.
Big digits time display, big LCD size digits display screen: Alarm time display,12/24 hour time format, calendar display
Battery Digital Clock: digital clock battery operated, No USB cable. Need 3* AAA 1.5V batteries (NOT INCLUDED)
Big LCD screen, energy saving, clear boldface number display, easy to read.
Convertible , 12HR & 24HR with simple operation.
Mini small digital clock, whole size of a palm , it can be stashed in bag when travel.
Kids alarm clocks for girls: 4 Color choose. pink clock for girls; blue/ black/white alarm clock for kids teens
When alarm is activated, the clock sounds beep for 60 seconds in a crescendo
Smart Alarm light,built in light sensor,LCD backlight turns on automaticaly when the room or circumstance becomes dark.and don't worry,this also wont disturb the sleepness.
Colourful Cube Digital Clock Alarm Clock 7 LED Color Digital Display
Alarm Clock
Digital Clock
LED colourful lights
Home and Office Decor
Calender
Date | Time
Temperature
LED Colour Changing Digital LCD Alarm Clock Thermometer Date Time Night Light Alarm and sleeping function Display Time, Data Week and Temperature.
Put It on Your Bedroom Side Table, Night Table, Work Desk, Dressing Table, Kitchen Shelf, Office Desk, Dining Table, Living Room Shelf, Etc.
Special functions: thermometers, alarm clocks, calendars, world time, night lights, decorations Power type: Battery Without batteries, you'll have to buy it yourself.
The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.
16984 Security Alarm Host Alarm Control Panel Suppliers
Short on time? Let Security Alarm Host Alarm Control Panel sellers contact you.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be
Connected to non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require
Special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Description:
8 led display of defense zone
Build-in dialer with build-in siren
Telephone line anti-cut function
Record your own personal message for ten seconds
Up to 6 telephone numbers can be pre-stored in the unit and dialed to summon help in priority order.
Remote command and access to the system from anywhere via a telephone/mobile
Emergency/panic button is available for 24 hours whenever arm/disarm
|¨¬
Relative humidity: ¡§a_ 90%
Dimension: 340mmx 250mm x 78mm (gift box)
Net weight: 1.2kg
If you want to know more information¡§a»s about wireless alarm system, please contact us by email, thanks. Hope we could help you on business.
Look forward to your favorable reply.
Summer pan
Dimension: 340mmx 250mm x 78mm (gift box)
Net weight: 1.2kg
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Mn/300/100 fire alarm control panel
Overview
The mn300 is a new type of analog fire alarm control panel which has 100 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses). It complies with the provisions of both fire alarm control units (gb4717-2005) and automatic control system for fire protection (gb16806-2006).
Features
1 the intelligent detectors and the intelligent modules have internal microprocessors to realize digital filtering and auto-compensation functions; the data collection is true and reliable; the mn300 control panel can carry out data processing based on fuzzy control theory and modern fire alarm theory to fundamentally avoid missing alarms and to reduce false alarms, so as to improve reliability.
2 the detectors have a sensitivity setup function and can adjust the alarm sensitivity according to the specific environment and their influences.
3 the detecting bus and the control bus share a two-wire structure and have non-polarity and fully mixed coding of the detectors and modules, and the intelligent detectors and the intelligent modules can be directly connected to them, which greatly simplifies the system wiring, engineering installation and circuit maintenance.
4 the system uses an ac-dc master-standby power supply system which will automatically change between the master and standby power supplies in the event of a power failure of either of the two power supplies to ensure uninterrupted operation of the system.
5 the mn300 can be connected to a special mini-printer to realize real-time printing.
6 the mn300 can be connected to floor fire display panels to display fire alarms by standard rs-485
7 the mn300 can be connected to ten multi-line linkage control/monitoring points to control and monitor important equipment.
8 the mn300 is equipped with eight bus manual control points, which makes it very easy for the user to control related equipment.
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected
To non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that
Require special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive)."
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Conventional Fire Alarm Control Panel with four Zones
2. Specifications
Two Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
One built-in Fire Fighting Ouput.
24-volt operation.
Resettable four-wire smoke detector power 500 mA.
Non-resettable power 500 mA.
One-man walk-test programmable for silent or audible test.
Disable/Enable control per IDC.
Reverse polarity protection.
3. Packaging and shipping
Conventional Fire Alarm Control Panel with four Zones
1 pc/carton box;carton M:43*17*51cm
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode