The luminox family is a range of factory calibrated optical sensors which measure ambient o2 levels using the principle of fluorescence quenching by oxygen.
Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle.
* low drift
* rohs compliant
* extended temperature range compared to electrochemical sensing devices
* low in cost
* factory calibrated
* measures temperature and pressure (if selected)
* small and compact
* maintenance free
Luminox unlike other sensor technologies is stable and robust, it is rohs compliant as it does not contain lead or any other hazardous materials and has negligible cross sensitivity.
Luminox can be purchased as a single optical sensor, or as part as an evaluation kit which includes the luminox sensor evaluation interface board, which was designed to allow customers to easily evaluate the sensor with minimum effort or design work.
Typical applications for the luminox optical oxygen sensor are;
* oxygen detection
* portable equipment
* breathing apparatus
* inerting
* medical
* lab equipment
* agriculture
* incubation
* fore prevention
* flue gas in condensing boilers
Part numbering system
Lox - xx
01: measures 0-300 mbar ppo 2 and temperature (â°c)
02: measures 0-300 mbar ppo 2 , 0-25% o 2 , temperature (â°c) and 500-1200mbar barometric pressure
Performance
Output î¼a @ 20.9% o2 80 to 120
Response time t90 (s) from 20.9% to 0% o2 < 15
Zero current î¼a in n2 < 2.5
Linearity % o2 deviation @ 10% o2 0.6
Lifetime
Output drift % change in output @ 3 months < 1
Operating life months until 85% original output of 20.9% o2 > 24
Environmental
Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7
Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1
Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1
Features:
* Long life
* Virtually no in�uence from CO2
* No external power supply required for sensor operation
* No warmup time is required
Applications:
* Water quality control
The GS Yuasa Dissolved Oxygen Sensor KDS-25B is a unique galvanic cell type sensor which was developed for water quality control. Its most notable features are long life expectancy and it is not influenced by CO2.
Specification:
Measurement range: 0~80mg/L dissolved oxygen
Accuracy in water at 25'C±1'C: ±5% (full scale)
Operating conditions
Atmospheric pressure: 81~203kPa (corresponds to 10m of water depth)
Temperature: 5~35'C
Relative humidity: 10 ~ 90%R.H. (no condensation)
Thermal time constant: 10 min. or less
Initial output voltage in clean air under standard test conditions: 8.0~15.0mV
Standard test conditions
Atmospheric pressure: 1013±5hPa
Temperature: 25'C±1'C
Relative humidity: 60±5%
Features:
* Virtually no influence from CO2, CO, H2S, NO, H2
* Temperature compensation circuit included
* Good linearity
* No position dependency
* Stable output signal
* No external power supply required for sensor operation
* No warmup time is required
Applications:
* Safety - Air conditioners, oxygen detectors, fire detectors, fuel cell systems
* Measurement - Oxygen monitors in flue gas
* Biotechnology - Oxygen incubators, anaerobic cultivators
* Food industry - Refrigeration, greenhouses
The Figaro Oxygen Sensor SK-25F is a unique galvanic cell type oxygen sensor. Its most notable features are no influence from CO2, good linearity up to 30% oxygen, and excellent chemical durability. This feature makes the sensor ideal for oxygen monitoring in various applications such as the biochemical field, food industry, and domestic safety applications.
Specification:
Measurement range: 0~30% O2
Accuracy: ±1% full scale
Operating conditions
Atmospheric pressure: 1013hPa ± 20%
Temperature: -10~50'C
Relative humidity: 0~99%RH (no condensation)
Response time (90%): â?¤ 15 seconds
Initial output voltage under factory test conditions: 5.5~8.5mV
Fcatory test conditions
Atmospheric pressure: 1013hPa
Temperature: 25±5'C
Life expectancy at 20'C in normal air: approx. 3 years
FOT-M Temperature sensor Fiber Optic Temperature sensor
The FOT-M is a fiber optic temperature sensor specifi cally designed for med-ical applications. The FOT-M temperature sensor combines all the desired characteristics you would expect from the ideal sensor. Its compact size, immunity to microwave and RF, resistance to corrosion, high accuracy and reliability make it the best choice for temperature measurements in harsh environments.
FISO's FOT-M fiber optic temperature sensor features complete immunity to EMI and RFI, built-in safety for medical applications, and high accuracy for temperature measurement. The FOT-M temperature sensor provides the medical industry with higher fi delity temperature measurements for demanding applications, like MRI applications.
Key Features
Intrinsically safe
Immune to EMI/RFI
Up to 85'C (180'F)
Accuracy of ±0.3'C
Miniature and rugged sensor
Fast response time
Applications
Medical applications
Industrial environments
Harsh and hazardous environments
MRI environment
Immune to microwaves and RF
Specifications
Temperature range: 20'C to 85'C (68'F to 185'F)
Resolution (*1): 0.1'C
Accuracy: ±0.3'C
Response time: Less than 750 ms
Connector type: ST connector
*1. Signal conditioner dependent
27815 Electronic Semi Conductor Devices Other Components Suppliers
Short on time? Let Electronic Semi Conductor Devices Other Components sellers contact you.
UVA-only SiC based UV photodiode A = 0.06 mm
Model Number: SG01SA18
1.Properties of the SG01SA18 UV photodiode
* UVA-only sensitivity, PTB reported high chip stability
* Active Area A = 0,06 mm2
* TO18 hermetically sealed metal housing, 1 isolated pin and 1 case pin
* 10mW/cm2 peak radiation results a current of approx. 222 nA
2.About the material Silicon Carbide (SiC)
SiC provides the unique property of extreme radiation hardness, near-perfect visible blindness, low dark current, high speed and low noise. These features make SiC the best available material for visible blind semiconductor UV de-tectors. The SiC detectors can be permanently operated at up to 170'C (338'F). The temperature coefficient of signal (responsivity) is also low, < 0.1%/K. Because of the low noise (dark current in the fA range), very low UV radiation intensities can be measured reliably
3.Options
SiC photodiodes are available with seven different active chip areas from 0.06 mm2 up to 36 mm2. Standard version is broadband UVA-UVB-UVC. Four filtered versions lead to a tighter sensitivity range. All photodiodes have a hermeti-cally sealed metal housing (TO type), either a 5.5 mm diameter TO18 housing or a 9.2 mm TO5 housing. Further op-tion is either a 2 pin header (1 isolated, 1 grounded) or a 3 pin header (2 isolated, 1 grounded).
Based on the rugged HS1101LF capacitive humidity sensor, HM1520LF is a dedicated humidity transducer designed for measurements at low humidity. Direct measurement of dew point or water concentration can be easily obtained in really cost effective conditions. Direct interface with a micro-controller is made possible with the moduleâ??s linear voltage output.
Main Features
* Tubular form for through wall mounting
* Not affected by water condensation
* Full interchangeability
* Typical 1 to 1.6 Volt DC output for 0 to 20% RH at 5 V DC supply
* Calibrated, linear voltage for easy electronic interface
* Controlled temperature dependency
* Ratiometric to voltage supply
Humidity Sensor Specfic Features
* No affected by long period at low humidity values.
* Patented solid polymer structure.
* High resistance to chemicals.
* Fast response time.
Features
* Battery operable
* High repeatability/selectivity to CO
* Linear relationship between CO gas concentration and sensor output
* Simple calibration
* Long life
* UL recognized component
* Meets UL2034, EN50291, and RoHS requirements
Applications
* Residential and commercial CO detectors
* CO monitors for industrial applications
* Ventilation control for indoor parking garages
* Recreational vehicle CO detectors
* Marine CO detectors
* Fire detection
Figaro's TGS5042 is a battery operable electrochemical sensor which offer several advantages over traditional electrochemical sensors. Its electrolyte is environmentally friendly, it poses no risk of electrolyte leakage, can detect concentrations as high as 1% CO, operates in a range from -40Ë? and +70Ë?C, and it has lower sensitivity to interferant gases. With a long life, good long term stability, and high accuracy, this sensor is the ideal choice for CO detectors with digital display. OEM customers will find individual sensors data printed on each sensor in bar code from, enabling users to skip the costly gas calibration process and allowing for individual sensor tracking. TGS5042 utilizes a standard AA battery-sized package.
Specifications
Model number: TGS5042-A00 (pin version)
TGS5042-B00 (ribbon version)
Target gases: Carbon monoxide
Typical detection range: 0 ~ 10,000ppm
Output current in CO: 1.2~2.4nA/ppm
Baseline offset:
Miniature 30 bar Pressure Sensor Module MS5541-30C
0-30 bar absolute pressure range
16 Bit ADC
10 - 1100 mbar absolute pressure range
6 coefficients for software compensation stored on-chip
Piezoresistive silicon micromachined sensor
Integrated miniature pressure sensor 6.2 x 6.4 mm
16 Bit ADC
3-wire serial interface
1 system clock line (32.768 kHz)
Low voltage and low power consumption
Description:
The MS5540C is a SMD-hybrid device including a precision piezoresistive pressure sensor and an ADC Interface IC. It is a miniature version of the MS5534C barometer/altimeter module and provides a 16-bit data word from a pressure and temperature dependent voltage. MS5540C is a low power, low voltage device with automatic power down (ON/OFF) switching. A 3-wire interface is used for all communications with a microcontroller. Compared to MS5534A the pressure range (measurement down to 10 mbar) has been improved. The MS5540C is fully software compatible to the MS5534C and previous versions of MS5540. In addition, the MS5540C is from its outer dimensions compatible to the MS54XX series of pressure sensors. Compared to the previous version, the ESD sensitivity level has been improved to 4kV on all pins. The gel protection of the sensor provides a water protection sufficient for 100 m waterproof watches without any additional protection.
Features:
Integrated pressure sensor
Small size 6.2 x 6.4 mm
Pressure range 10-1100 mbar
Resolution 0.1 mbar
16 Bit ADC
6 coefficients for a software compensation stored on-chip
3-wire serial interface
1 system clock line (32.768 kHz)
Temperature range -40 ~ +85'C
Low voltage (2.2 to 3.6V)
Low power (Standby current:0.1uA)
Pb-free and RoHS-compatible
No external components required
1.Features
Gallium Nitride Based Material
Schottky-type Photodiode
Photovoltaic Mode Operation
Good Visible Blindness
High Responsivity & Low Dark Current
2.Applications
UV Index Monitoring
UV-A Lamp Monitoring
In some pathological cases (multiple myeloma etc) abnormal monoclonal bands appear in electrophorogram. The identification of these monoclonal bands can be done by different immunological techniques such immunofixation electrophoresis (ife).
Hellabio offers 2 kind of ife kits. Kit ife 01 is for 10 tests and the kit ife d01 is for 20 tests. Each kit is complete containing all needed reagents and the monospecific antisera.
The hot air gel drier is perfect for drying agarose gels up to 12x15 cm. The drier is easy to use and produces high-quality results. The gels are heated from over and the air removes the moisture so that the gel dries homogeneously. The dried gels are ideal for densitometry this manual is considered as a part of the instrument; it has to be at the operator's hand as well as at the maintenance operator's availability. For accurate installation, use and maintenance, please read the following instructions carefully. In order to avoid instrument or personal damages, carefully read the "general safety warnings", describing the suitable operating procedures. In case of breakdowns or any troubles with the instrument, apply to the local technical service.
Being a well-established enterprise, we are offering an inclusive consignment of GSM Rubber duck 9dbi Antenna
Product Details:
Elevated performance
Excellent design
High conductivity
Longer life
Easy to use
Quick installation
we are in manufacturer and supplyer of best quality GSM Internal Antenna. Known for its compact design and perfect finish, the whole range of high quality internal antennas offered by us has fetched high demands in the market. Committed to the satisfaction our clients, we make the offered products available at cost-effective prices.GSM PCB Internal antenna using in internally GSM device.
Features:
Compact design
Light weight
Perfect finish
GSM Sicker antenna is stick type antenna , and it is Extensively used for long distance communication. Known for its high tensile strength and durability, the entire range of high quality GSM sticker antennas offered by us is highly popular in the market.
Applications
Automation
Monitoring
Energy manageme
Traffic engineering
Designed for GSM system, Wireless bridge
Point to point & Point to multipoint applications.
Being one of the largest companies, we are involved in presenting a wide range of GPS Marine Antennas to meet the necessities of our clients, in very effective price with wide ranges
Features:
High strength
Rigid structure
Quality approved design
Smooth finish
Longer life
Less maintenance