YJ-120 series Mechanical Flow meter is used for fuel transferring application, diesel fuel, kerosene ect.These flow meters are reliable, inexpensive, and easy to install and simple to calibrate on the workplace.lt has the advantage of easy reading, quick resetting, and knob, flexible flow ports can be positioned vertically or horizontally. The easy reset register indicates product use up to 999/999.9.The master totalizer registers up to 999999/9999, 9999.Aluminium metering chamber, thread connection. Mechanical readout device with rotating wheels.
Digital oil flowmeter suitable for the lubrication oil flow meter guns and suitable for metering the engine oil,motor oil,freeze oil,hydraulic oil and all kinds of lubrication oil...
YJ-120 series Mechanical Flow meter is used for fuel transferring application, diesel fuel, kerosene ect.These flow meters are reliable, inexpensive, and easy to install and simple to calibrate on the workplace.lt has the advantage of easy reading, quick resetting, and knob, flexible flow ports can be positioned vertically or horizontally. The easy reset register indicates product use up to 999/999.9.The master totalizer registers up to 999999/9999, 9999.Aluminium metering chamber, thread connection. Mechanical readout device with rotating wheels.
Digital oil flowmeter suitable for the lubrication oil flow meter guns and suitable for metering the engine oil,motor oil,freeze oil,hydraulic oil and all kinds of lubrication oil...
Apply to engine oil, gear oil, automatic gear-box oil, hydraulic oil, antifreeze and similar products of precision filling;
Filling the total memory, a single volume displays filling function;
5 easy to read LCD display, a 3V battery-powered; Automatic power-saving mode.
Real-time error coefficient of calibration, easy to operate;
Multi-unit selection
With anti-drip function, anti-drip muzzle
Rotary Joints 1 / 2 "easy to use, anti-collision switch design.
853 Water Meter Suppliers
Short on time? Let Water Meter sellers contact you.
Multi-jet dry-dial meter for cold water
Nominal flow rate Qn 1.5 to 15 m3/h/ Q3 2.5 to 25 m3/h
EEC approval metrological class B·H
MID-type examination certificate R160
Good readability even at extreme operational conditions
Hermatically sealed counter
Antimagnetic shield (optional)
ELSTER conText inscription system
FILL-RITE 901CL Mechanical Flow Meter
Features
Flow ports that can be positioned vertically or horizontally
Maximum pressure of 50 psi (3.5 bar)
Aluminum housing with Viton and Buna seals
UL/cUL, CE listed
±2% accuracy
1' inlet and outlet
Multi-jet dry-dial meter for cold water
Nominal flow rate Qn 1.5 to 15 m3/h/ Q3 2.5 to 25 m3/h
EEC approval metrological class BH
MID-type examination certificate R160
Good readability even at extreme
operational conditions
Hermatically sealed counter
Antimagnetic shield (optional)
ELSTER conText inscription system
Description
Water Meter for Hot & Cold water is manufactured using advanced technology, in which the register device is combinated pointers and rolling counters for convenience, clarity & correctness as well as nice appearance.
The register system is designed by means of magnetic drive, which is hermetically sealed and completely separates register system from water. These water meters have high accuracy of measurement and steady error curve of flow rate. The performance is more advanced than existing ISO â?? Standard
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
(APS Marines & Logistics)
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Cold
Water Temperature: 50C
Water Pressure: 1MPa
P < 0.03 MPa
(APS Marines & Logistics)
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Hot
Water Temperature: 90 C
Water Pressure: 1MPa
P < 0.03MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
Hot: Exclusive: + 3%
Application
Dismountable spiral hot water is for recording discharge, flowing through its pipe. It can not record the amount of polluted water end corrosive liquid
(APS Marines & Logistics)
Description
Type LXSG-15E-50E water meter for cold water is manufactured by using advanced technology, in which, the register device is combinated pointers and rolling counters which is convenient, clear and correct for reading as well as nice appearance.
The register system is designed by means of magnetic-drive, which is hermitically-sealed and completely separates the register system & water. It however can not be influence even if in pure water condition as well as corrosion of indicating dial. These water meter have high accuracy of measurement, steady error curve of flow rate. The performance is more advanced than existing ISO standard.
Working Conditions
Water Temperature < 50 C
Water Pressure < 1MPa
P < 0.1MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
Application
This water meter is used for measurement of total quantity of water passing through the pipeline.
It is available for water flowing in a single direction.
(APS Marines & Logistics)
Description
Product Standard: ISO 4064 Class B
End Details: Flanges as per DIN:2533 RF (PN16) Drilled
Features
It is dismountable and it can be pulled out easily for repair.
The recorder is sealed so that readings are clear.
The pressure loss is small and it has big flow capacity.
It can be installed vertically or horizontally.
Working Conditions
Pressure Rating: PN 1.6 (16 Bar) Hyd.
Maximum Temperature: 45 C
Working Pressure: 1.0 MPa Hyd.
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+2%
(APS Marines & Logistics)
Features
Dry register and register with 5 or 8 numbered roller.
Brass body can be painted or nickel coated.
High accuracy.
Measuring unit is m
The meters conform to ISO4064 Standard Class B.
Working Conditions
Water temperature 30 C; hot water meter 90 C
Water pressure 1MPa (PN:1.6MPa/16bar)
P < 0.1MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
(Hot water meter: �±3%)
(APS Marines & Logistics)
Description
Electromagnetic Flow Meters follow the Faraday Law of Electromagnetic Induction. They are used to accurately measure the flow rate of liquids which are electrically conducting.
Nominal Size: 25-200 mm
Electrode Material: SS 316L
Lining Material: FEP
Flange Material: Carbon Steel
Flow Sensor Housing: SS 316
Flow Sensor Protection Class: IP 65
Power Supply: 85VAC 240VAC
Signal Output: 4~20mA
Pulse Output: Adjustable from 0.001 to 1000 L Pulse
Communication: RS 485 with Galvanic Isolation, MODBUS
Cable Length: 5M
Features
No moving parts. virtually no pressure lost.
Corrosion protection, abrasion resistant.
High accuracy, stable performance.
High level of anti-vibration and anti-jamming, wide measuring dimensions.
Multi output interface: 4~20mA, Pulse, Alarm outputs, RS â?? 485 (Modbus) communication.
Working Conditions
Pressure Rating: PN16
Temperature Rating: <80 C
Relative Humidity: <85%
Accuracy
Accuracy: +0.5%
(APS Marines & Logistics)
Feeder of Raw meal includes steady flow feeder, mass flow meter, gas-solid injector and FB-DACS5000 control system. It has a great effect on improving the stability of kiln working conditions, improving the working time and clinker strength, saving energy and prolongs the service life of refractory materials.
Accuracy: +/- 0.5%
Weighing Range: 100-1200 m3/h
GMF200-W ultrasonic water meter is designed for water metering settlement and production of a high performance products, with the remarkable features of low power consumption, wide measuring range ratio, stable and reliable measurement .Each component reaches IP68 protection class, to ensure long term operation though water in the inside meter.
Pipe type ultrasonic flowmeter is composed of a main body and a pipe segment type sensor. The DN15-DN32 uses a -type pipe segment sensor, and the DN40 and above uses a standard pipe segment sensor. The pipe-type ultrasonic flowmeter has the advantages of simple installation, low starting flow, high measurement accuracy, and no pressure loss.
The main unit can be installed in the wall, instrument box, and distribution box with a protection level of IP67. The external clip sensor is installed on the surface of the pipe and selects different sensors. The applicable diameter is DN15~DN6000.
853 Water Meter Suppliers