Water Meter for Hot & Cold water is manufactured using advanced technology, in which the register device is combinated pointers and rolling counters for convenience, clarity & correctness as well as nice appearance.
The register system is designed by means of magnetic drive, which is hermetically sealed and completely separates register system from water. These water meters have high accuracy of measurement and steady error curve of flow rate. The performance is more advanced than existing ISO â?? Standard
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
(APS Marines & Logistics)
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Cold
Water Temperature: 50C
Water Pressure: 1MPa
P < 0.03 MPa
(APS Marines & Logistics)
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Hot
Water Temperature: 90 C
Water Pressure: 1MPa
P < 0.03MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
Hot: Exclusive: + 3%
Application
Dismountable spiral hot water is for recording discharge, flowing through its pipe. It can not record the amount of polluted water end corrosive liquid
(APS Marines & Logistics)
Description
Type LXSG-15E-50E water meter for cold water is manufactured by using advanced technology, in which, the register device is combinated pointers and rolling counters which is convenient, clear and correct for reading as well as nice appearance.
The register system is designed by means of magnetic-drive, which is hermitically-sealed and completely separates the register system & water. It however can not be influence even if in pure water condition as well as corrosion of indicating dial. These water meter have high accuracy of measurement, steady error curve of flow rate. The performance is more advanced than existing ISO standard.
Working Conditions
Water Temperature < 50 C
Water Pressure < 1MPa
P < 0.1MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
Application
This water meter is used for measurement of total quantity of water passing through the pipeline.
It is available for water flowing in a single direction.
(APS Marines & Logistics)
Description
Product Standard: ISO 4064 Class B
End Details: Flanges as per DIN:2533 RF (PN16) Drilled
Features
It is dismountable and it can be pulled out easily for repair.
The recorder is sealed so that readings are clear.
The pressure loss is small and it has big flow capacity.
It can be installed vertically or horizontally.
Working Conditions
Pressure Rating: PN 1.6 (16 Bar) Hyd.
Maximum Temperature: 45 C
Working Pressure: 1.0 MPa Hyd.
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+2%
(APS Marines & Logistics)
Features
Dry register and register with 5 or 8 numbered roller.
Brass body can be painted or nickel coated.
High accuracy.
Measuring unit is m
The meters conform to ISO4064 Standard Class B.
Working Conditions
Water temperature 30 C; hot water meter 90 C
Water pressure 1MPa (PN:1.6MPa/16bar)
P < 0.1MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
(Hot water meter: �±3%)
(APS Marines & Logistics)
Description
Electromagnetic Flow Meters follow the Faraday Law of Electromagnetic Induction. They are used to accurately measure the flow rate of liquids which are electrically conducting.
Nominal Size: 25-200 mm
Electrode Material: SS 316L
Lining Material: FEP
Flange Material: Carbon Steel
Flow Sensor Housing: SS 316
Flow Sensor Protection Class: IP 65
Power Supply: 85VAC 240VAC
Signal Output: 4~20mA
Pulse Output: Adjustable from 0.001 to 1000 L Pulse
Communication: RS 485 with Galvanic Isolation, MODBUS
Cable Length: 5M
Features
No moving parts. virtually no pressure lost.
Corrosion protection, abrasion resistant.
High accuracy, stable performance.
High level of anti-vibration and anti-jamming, wide measuring dimensions.
Multi output interface: 4~20mA, Pulse, Alarm outputs, RS â?? 485 (Modbus) communication.
Working Conditions
Pressure Rating: PN16
Temperature Rating: <80 C
Relative Humidity: <85%
Accuracy
Accuracy: +0.5%
(APS Marines & Logistics)
Product : Cast Steel Y-Type Strainer
Type of Pattern : Y-Type
Body Material cum Standard : CCS (ASTM A216 Gr.WCB)
Description : Y-Type Bolted Cover
Trim : SS AISI-304 Screen having 1.2 dia perforation
End Details : Flanges as per BS 10 Table J FF Undrilled
Testing & Certification
Body Test Pressure : 700 Psig Hyd.
Working Pressure : Max. BOP 350 Psig.
Maximum Working Temperature: 400C
Test Certificate in Form lll-C as per IBR is furnished with every supply.
(APS Marines & Logistics)
Product : Sant Cast Steel Y Type Strainer
Type of Pattern : Y Type
Body Material cum standard : CCS (ASTM A-216 Gr. WCB)
Product Description : Bolted Cover Type
Trim : AISI-304, Screen 1.2mm dia perforation
End Details : Flanges as per BS10 Table F/Class-150
Testing & Certification
Body Test Pressure : 40kg/cm Hyd.
Maximum Working Pressure : 20kg/cm
Maximum Working Temperature : 400 C
Our Works Test Certificate is furnished with every supply.
Product : Forged S.S.Thermodynamic Steam Trap
Body Material cum Standard : FSS (AISI-410)
Description : Thermodynamic Type with inbuilt strainer
Type of Seat : Renewable Seat
Type of Disc : Renewable Disc
Trim : SS AISI-410
End Details : Socket Welded Ends as per ASME B-16.11
Testing & Certification
Body Test Pressure : 900 Psig Hyd.
Working Pressure : Max. BOP 450 Psig. (31.65Kg/cm)
Maximum Working Temperature : 400 C
Test Certificate in Form lll-C as per IBR is furnished with every supply