Please click here to check who's online and chat with them.

Find Verified Electric Circuit Breakers Suppliers, Manufacturers and Wholesalers

May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage( Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Time
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current In: 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: EC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 4.5/6kA
Rated working current: In 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
1035 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity( Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 10kA
Release Type of Leakage Protection: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity Icn: 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-32A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity( Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current In: 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life :4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue) : AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-21-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: C/D
The number of poles: 1P+N
Rated short circuit breaking capacity: Icn 4.5kA
Rated working current: In 6-40A
Rated working voltage Ue : AC 230V
Rated operating frequency : 50/60Hz
Rated insulation voltage Ui: 500V
Rated impulse withstand voltage Uimp: 4kV
Mechanical/electrical life: 10000/4000 Times
1035 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
See what buyers and suppliers are discussing in Electric Circuit Breakers import export community