Temperature Head Transmitter

Supplier From South Korea (Republic Of Korea)
Nov-01-16

2-wire technology and analog signal output (4-20mA)
High accuracy in total ambient temperature range
Wide power supply range (voltage)
Easy programming (calibration) via HART modem


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Temperature Head Transmitter

Oct-17-11
 
• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).



Appearance and Size (in mm)

NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
Oct-30-19
 
Product Overview

NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control.

Features

Support multiple thermal resistance and thermocouples
Thermal resistance supports 2/3/4-wire connection mode
Thermocouple can use cold end compensation function
Better accuracy: PT100 ±0.3 ; K-type ±0.4
Universally programmable for various input signals
Available protocols: HART /FF H1 /PROFIBUS PA
Parameter

Value

Input Signal

Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω

Thermocouple: B, E, J, N, K, R, S, T

Voltage signal: -100mV~100mV

Channel Single

RTD Wiring 2-wire, 3-wire, 4-wire

Bus Power 9~32 VDC Current consumption (static): â?¤14mA

Bus Signal Communication ratio 31.25Kbit/s, current mode

Isolation Between terminal and housing: 1kV

Working Temperature -40~85

Humidity Range 10%~90%RH

Start Time â?¤5s

Refresh Time 0.5s

EMC GB/T 18268-2000

Protection IP20

Signal Type Suggested Range ()

Accuracy
Resistance 0~500Ω,0~4000Ω ±0.05%
PT100 -200 ~ 850 ±0.2
PT1000 -200~ 850 ±0.1
CU50 -50 ~ 150 ±0.3
CU100 -50 ~ 150 ±0.2
mV -100mV ~ 100mV 0.05%
B 500 ~ 1810 ±1.0
E -200 ~ 1000 ±0.4
J -190 ~ 1200 ±0.4
K -200 ~ 1372 ±0.4
N -190 ~ 1300 ±0.8
R 0 ~ 1768 ±1.0
S 0 ~ 1768 ±1.0
T -200 ~ 400 ±0.4
Aug-14-22
 
The ZP series Temperature Transmitter is designed to meet common Single Point measurement application requirements. This transmitter can easily work with a variety of sensors (RTDs and thermocouples) and thermowells. It provided in a head mount configuration suitable for installation in a wide variety of connection heads and housings. A PC-programmable interface is available, providing an easy-to-use configuration method from any PC.

Basic temperature transmitter offers a reliable solution for temperature monitoring points, provides flexible and reliable performance in process environments, Excellent performance with low temperature drift and auto zero calibration, reducing the need for expensive extension wires and multiplexers.

Power Supply 8.5VDC~32VDC
Input Types 4-20mA / 20-4mA;
RTD(PT100,PT200,PT500,PT1000,Cu50);
R(0-400 ,0-4000 );
TC(K,E,S,B,R,J,T,N);
mV(-80-+80mV);
V(0-1V)
Output signal types 4-20mA or 0...1/5V, 0...1/10V
Response Time < 0.4S (0-90%,100%-10%)
Precision �±0.05%
Temp. Drift 0.01% per Celsius
Volt fluctuation influence �±0.005% X span / below V DC
Load Capacity < 700 in 24VDC; (mA output)
< 1060 in 36VDC (Volt output)
Isolation Strength AC1500v 1min between the input / output
IP Ranking Casing/Terminal IP50/IP20
Nov-01-16
Supplier From Ansan-si, South Korea (Republic Of Korea)
 
- Great performance with excellent RTD sensor element
- 2-Wired 4~20mA output
- IP65 class for the extreme condition use
Oct-17-11
 
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type RTD, TC, R or Millivolt signal
Convert accuracy 0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output
Max-load £¨V -13V£©/0.025A£¨Current output £©
Limit current 25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
3.6mA or ¡Ý21.0mA
Power supply 13¡«30V DC
Temperature drift 0.01£¥ FS/1
Long-term stability 0.1 per year or 0.05 £¥per year
Ambient -40¡«+85.
Oct-17-11
 
MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output.
It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance.
Primary Technical Characteristics
Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ
£¨according to user's demand£©
Input type Pt100,Cu50£¨TC if specially required£©
Measuring Points 2,3,4,5,6 points
Convert accuracy ¡Ü0.5£¥FS
linearity error < 0.1%
Output 4¡«20mA Electrical isolation output
Digital display LED
Display accuracy 0.5%
Voltage drop for display 3V
Isolated voltage Drop 2V
Isolate Voltage 1500V AC (Input/Output¡¢with isolator)
Max-load £¨V -14V~16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Power supply 14~30V DC
Temperature draft 0.025% FS/ 1¡æ
Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year
Ambient -40~+85¡æ£¨Aluminium alloy .Casing£©
-25 ~+75¡æ£¨Plastic Casing£©
Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£©
Anti-RFI >10v/m(80MHz¡­¡­1000MHz).
Jul-24-07
 
Universal head transmitter anl 181

Universal head transmitter for resistance thermometers (rtd), thermocouples, resistance and voltage transmitters, settable using a pc, for installation in a sensor head (form b), compatible tmt 181.
Areas of application
Pc programmable (pcp) temperature head transmitter for converting various input signals into an scalable 4 to 20 ma analogue output signal
Input:
Resistance thermometer (rtd)
Thermocouple (tc)
Resistance transmitter (ohm)
Voltage transmitter (mv)
Online configuration using pc with anl 181 configuration kit and pc-software anly win 2000 (compatible e+h readwin 2000)
Benefits at a glance
Universally pc programmable for various signals
Galvanic isolation
2 wire technology, 4 to 20 ma analogue output
High accuracy in total ambient temperature range
Fault signal on sensor break or short circuit, presettable to namur ne 43
Emc to namur ne 21, ce
Ul recognized component to ul 3111-1
Ship building approval gl
Online configuration during measurement using setup connector
Output simulation
Customer specific measurement range settings or expanded setup
Technical data
Input: Rtd, tc, ohm, mv
Output: 4 to 20 ma
Supply voltage: 8 to 35 v dc (non-ex-area)
8 to 30 v dc (ex-area)
Operation: Pcp (pc programmable)
Installation: Sensor head form b
Field housing

Verification Status