Please click here to check who's online and chat with them.

Zp-02 Head-Mounted Temperature Transmitter

Supplier From China
Aug-14-22

The ZP series Temperature Transmitter is designed to meet common Single Point measurement application requirements. This transmitter can easily work with a variety of sensors (RTDs and thermocouples) and thermowells. It provided in a head mount configuration suitable for installation in a wide variety of connection heads and housings. A PC-programmable interface is available, providing an easy-to-use configuration method from any PC.

Basic temperature transmitter offers a reliable solution for temperature monitoring points, provides flexible and reliable performance in process environments, Excellent performance with low temperature drift and auto zero calibration, reducing the need for expensive extension wires and multiplexers.

Power Supply 8.5VDC~32VDC
Input Types 4-20mA / 20-4mA;
RTD(PT100,PT200,PT500,PT1000,Cu50);
R(0-400 ,0-4000 );
TC(K,E,S,B,R,J,T,N);
mV(-80-+80mV);
V(0-1V)
Output signal types 4-20mA or 0...1/5V, 0...1/10V
Response Time < 0.4S (0-90%,100%-10%)
Precision �±0.05%
Temp. Drift 0.01% per Celsius
Volt fluctuation influence �±0.005% X span / below V DC
Load Capacity < 700 in 24VDC; (mA output)
< 1060 in 36VDC (Volt output)
Isolation Strength AC1500v 1min between the input / output
IP Ranking Casing/Terminal IP50/IP20

Price and Minimum Quantity

Price: $200
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Zp-02 Head-Mounted Temperature Transmitter

Oct-30-19
 
Product Overview

NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control.

Features

Support multiple thermal resistance and thermocouples
Thermal resistance supports 2/3/4-wire connection mode
Thermocouple can use cold end compensation function
Better accuracy: PT100 ±0.3 ; K-type ±0.4
Universally programmable for various input signals
Available protocols: HART /FF H1 /PROFIBUS PA
Parameter

Value

Input Signal

Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω

Thermocouple: B, E, J, N, K, R, S, T

Voltage signal: -100mV~100mV

Channel Single

RTD Wiring 2-wire, 3-wire, 4-wire

Bus Power 9~32 VDC Current consumption (static): â?¤14mA

Bus Signal Communication ratio 31.25Kbit/s, current mode

Isolation Between terminal and housing: 1kV

Working Temperature -40~85

Humidity Range 10%~90%RH

Start Time â?¤5s

Refresh Time 0.5s

EMC GB/T 18268-2000

Protection IP20

Signal Type Suggested Range ()

Accuracy
Resistance 0~500Ω,0~4000Ω ±0.05%
PT100 -200 ~ 850 ±0.2
PT1000 -200~ 850 ±0.1
CU50 -50 ~ 150 ±0.3
CU100 -50 ~ 150 ±0.2
mV -100mV ~ 100mV 0.05%
B 500 ~ 1810 ±1.0
E -200 ~ 1000 ±0.4
J -190 ~ 1200 ±0.4
K -200 ~ 1372 ±0.4
N -190 ~ 1300 ±0.8
R 0 ~ 1768 ±1.0
S 0 ~ 1768 ±1.0
T -200 ~ 400 ±0.4
GOLD Member
May-12-24
Supplier From Kolkata, West Bengal, India
GOLD Member
Jun-10-21

Hand Max Power Cut Sleeve 14Inch

$8
MOQ: Not Specified
Sample Available
Supplier From Busan, South Korea (Republic Of Korea)
 
- Material : Stainless Steel Core, Polyethylene Yarn, Span Yarn
- Number of Stitiches : 10 Gauge
- Length : 14 inch
- Cut Level : 5
- Color : Gray, Black, White
- Packing : 1pair/individual packing (1pack=5pair, 1box=200pair)
- Origin : Made in South Korea
- Purpose : Cut Resistant
Oct-17-11
 
• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).



Appearance and Size (in mm)

NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
GOLD Member
May-15-25
Supplier From Mumbai, Maharashtra, India
SILVER Member
Dec-29-24
 
PE coil pipes and tubes for water and wire cable conduit PL231


The PE coil pipes and tubes can be used:

water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm
pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm
weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm


We use new 100% pure raw PE material


WHY NEW MATERIAL HDPE PIPES?

1. Health performance

PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria.

2. Corrosion resistance

It can resist various chemical media erosion, with no electrochemical corrosion.

3. Service life

Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years.

4. Impact resistance

PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break.

5. Connection performance

The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load.

6. Construction performance

It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
Nov-01-16
Supplier From Ansan-si, South Korea (Republic Of Korea)
 
- Great performance with excellent RTD sensor element
- 2-Wired 4~20mA output
- IP65 class for the extreme condition use

Verification Status