We are manufacturer & exporter of Brass Neutral Links. They are designed with the intention of minimising issues during installation. The screws minimize the risk of shearing, stripping and cross threading which each hole is clearly identified with an engraved number. Brass Neutral Links are available in various configurations. Brass Neutral Links and Bars are used for ground or earth in mains electrical wiring system which provides a low impedance path to the earth to prevent hazardous voltages from appearing on equipment.
Terminal Blocks are all developed exclusively as per Customers design & specification.
Application :
Used in Street Light Isolator, Distribution Board, Switchgear, Electrical Panels Boards, Electrical and Telecommunication, Circuit breaker, RCD, etc.
In MCBs ELCBs and Isolators to protect the installation
For termination of neutral and ground wires on bus bar
For termination of Rated Conductors
For mounting of DIN Rails and clamp type
For surface mount applications
Designed for Easy Installation and Termination
Carries current back to the source
Material : Free Cutting Brass, High Tensile Brass, CDA 360 Brass, Alloy 360 Brass, CDA 230 Brass.
Size : Begins from M2 or equivalent threads, 2 ways to 50 ways.
Length : 1 meter to 15 meter or as per customers requirement.
Suitability : 70Amp, 90A, 110A, 165A through 350Amp
Finish : Natural, Nickel Plated, Tin Plated, Chrome Plated, Electrolyte Tin Plated or any coating as per customer specification.
Features :
Lighter and easier to handle.
The use of modern polymer channel has reduced the weight of the products making them easier to handle.
Pre-Drilled fixing holes for ease of installation.
Plastic channel base is entirely corrosion proof.
High Durability, Tensile strength and Resistant to adverse conditions.
Drop out fuses and load-drop fuses are outdoor high voltage protection appliances. It is installed on the high voltage side of the distribution transformer or on the branch line of the distribution line. used as a short circuit of the transformer and the line, overload protection and split load current.
The drop fuse is composed of two parts:
An insulating bracket and a fuse tube. The static contact is installed at two ends of the insulating bracket, the movable contact is installed at both ends of the fuse tube, and the fuse tube is composed of an inner arc extinguishing tube and an outer layer.
It consists of a phenolic paper tube or an epoxy glass tube. The load drop fuse enhances the elastic auxiliary contact and the arc extinguishing cover to divide and combine the load current.
Product use environment:
1. The ambient temperature is not higher than +40 C, not lower than-40 C
2.The altitude does not exceed 3000m
3.The maximum wind speed does not exceed 35m/s
4.The earthquake intensity does not exceed 8 degrees
1. Use
(H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current.
2. Brief introduction of structure
The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse.
Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero.
3. Implementation criteria
The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard.
4. Conditions of Use
1. Environmental temperature: - 40 ~40 C;
2. No more than 1200 m above sea level;
3. The wind speed is not more than 35m/s.
4. Earthquake intensity does not exceed 8 degrees.
5. Fuses are not suitable for the following places:
A. Places where there is a danger of combustion or explosion;
B. Places with violent vibration or shock;
C. Areas with heteroelectrochemical gases, severe air pollution and salt fog.
5. Instructions for Order
1. Product type, name, rated voltage, rated current and rated switching-on current;
2. Environmental requirements (anti-pollution, plateau type);
3. Special requirements can be consulted with our company.