Please click here to check who's online and chat with them.

Outdoor High Voltage Drop Fuse

Supplier From China
Apr-18-20

1. Use
(H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current.
2. Brief introduction of structure
The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse.
Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero.
3. Implementation criteria
The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard.
4. Conditions of Use
1. Environmental temperature: - 40 ~40 C;
2. No more than 1200 m above sea level;
3. The wind speed is not more than 35m/s.
4. Earthquake intensity does not exceed 8 degrees.
5. Fuses are not suitable for the following places:
A. Places where there is a danger of combustion or explosion;
B. Places with violent vibration or shock;
C. Areas with heteroelectrochemical gases, severe air pollution and salt fog.
5. Instructions for Order
1. Product type, name, rated voltage, rated current and rated switching-on current;
2. Environmental requirements (anti-pollution, plateau type);
3. Special requirements can be consulted with our company.
Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Outdoor High Voltage Drop Fuse

GOLD Member
VERIFIED
Jun-20-25
Supplier From Howrah, West Bengal, India
Feb-16-23

High Voltage Fuses

$13
MOQ: Not Specified
 
Porcelain High Voltage Fuses for Transformer Protection, high quality with copper material. 12KV 24KV 35KV Fuses.
Dec-26-12
 
Technical parameters for XRNT-36KV fuse:

Rated voltage: 36KV

Rated current of fuse: 25A

Dimension: 442mm*51mm

Type Rated voltage (KV) Rated current (A) Diameter (mm) Length (mm)

XRNT1 3.6 6.3 10 16 20 25 31.5 40 51 192
XRNT1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292
XRNT1 7.2 80 100 125 160 76 292
XRNT1 12 10 16 20 25 31.5 40 51 292
XRNT1 12 50 63 71 80 100 76 292
XRNT1 12 125 76 292
XRNT1 12 160 200 88 292
XRNT1 24 6.3 10 16 20 25 31.5 40 51 442
XRNT1 24 50 63 71 80 100 76 442
XRNT1 24 125 76 442
XRNT1 24 160 88 442
XRNT1 40.5 3.15 6.3 10 16 20 25 51 537
XRNT1 40.5 31.5 40 76 537
XRNT1 40.5 63 88 537


3pcs a carton
Dec-26-12
 
Type k high voltage fuse link for dropout fuse cutout.

1). Product description:
This fuse wires apply to the 11kv -36kv drop out fuse.

2). Standard:
According to ansi/ieee c37.41-2000 and iec-282 standard.

3). Technical specification:
Rated current: 1a-300a
Rated voltage: 11kv-27kv
Length: 530mm-600mm (23 inch)

Length of fuse link can be make according to requests.


500pcs a carton
SILVER Member
Dec-29-24
 
PE coil pipes and tubes for water and wire cable conduit PL231


The PE coil pipes and tubes can be used:

water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm
pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm
weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm


We use new 100% pure raw PE material


WHY NEW MATERIAL HDPE PIPES?

1. Health performance

PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria.

2. Corrosion resistance

It can resist various chemical media erosion, with no electrochemical corrosion.

3. Service life

Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years.

4. Impact resistance

PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break.

5. Connection performance

The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load.

6. Construction performance

It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
GOLD Member
Feb-18-21
 
Product description

VFD for biomass burner, biomass gasification burner. For electric cabinet frequency and voltage converting, to meet different countries voltage. Ensure the bioamss burner can work well.
Dec-26-12
 
Din hrc "s" type high voltage fuse for transformer protection:

1. According to bussmann din "s" type high performance back-up fuse
2. Comply with iec282-1, din, bs
3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use.
4. Any other specifications can be designed specially.

Type rated voltage (kv) rated current (a) diameter (mm) length (mm)
Xrnt1 3.6 6.3 10 16 20 25 31.5 40 51 192
Xrnt1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292
Xrnt1 7.2 80 100 125 160 76 292
Xrnt1 12 10 16 20 25 31.5 40 51 292
Xrnt1 12 50 63 71 80 100 76 292
Xrnt1 12 125 76 292
Xrnt1 12 160 200 88 292
Xrnt1 24 6.3 10 16 20 25 31.5 40 51 442
Xrnt1 24 50 63 71 80 100 76 442
Xrnt1 24 125 76 442
Xrnt1 24 160 88 442
Xrnt1 40.5 3.15 6.3 10 16 20 25 51 537
Xrnt1 40.5 31.5 40 76 537
Xrnt1 40.5 63 88 537


3pcs a carton