SUS304 stainless steel Electromagnetic Flowmeter
measurement, high precision, flow range reach to 1500: 1;
4. Converter adopts to 16-bit embedded microprocessor and surface mounting technology, convenient preferences, totally Chinese menu operation, easily use, with self-check and diagnosis functions;
5. With the function of measuring two way flow, can show the positive and reverse flow, also have two way current and rate output, which is convenient for the record and store different flow signal;
6. Inside have three counters, which can separately show positive cumulation, reverse cumulation and D-value calculation;
7. With RS485 or RS232 digital communication signal output;
8. With self-check and diagnosis functions.
QTYB G
Standard Type R
Remote type S
Sanitary Type I
Insertion Type
Medium Conductivity Fluids
Accuracy ± 0.5% ± 0.5% ± 0.5% ± 1.5%
Repeatability ± 0.25% ± 0.25% ± 0.25% ± 0.75%
Fluid Temperature -25° C ~ 130 ° C -25° C ~ 130 ° C -25° C ~ 130 ° C -25° C ~ 130 ° C
Conductivity ≥ 5¦Ìs/cm ( soft water should be ≥ 20 ¦Ìs/cm)
Size 10mm ~2200 mm 10mm ~2200 mm 10mm ~125 mm 200mm ~3000 mm
Operation Pressure 0.6Mpa/1.0Mpa/1.6Mpa/2.5Mpa/4.0Mpa/Others
Velocity 0.5 m/s ~ 10 m/s
Flow Direction Forward / Reversed
Electrodes Material 316L / Hastelloy C2, B4/Tantalum/Titanium/Platinoiridita/others
Liner Material Rubber /PTFE/PFA PFA PTFE
Electrodes Type Standard
Qty of Electrodes 2 pairs ( one pair for measuring, one pair for grounding) 1 pair( for measuring)
Measuring tube Material 304 Stainless Steel
Flange Material Carbon steel/304 Stainless steel 304 Stainless steel 304 Stainless steel
Installation Type Wafer/flange Tri-clamp/screw Flange/plug-in
Protection level IP65/P68 ( Remote Version)
Power 220VAC ± 20% 60HZ / 24 VDC
Signal Output 4~20mA
Communication Hart / Modbus/ Profibus
Electrical connection 2* M20 * 1.5
Explosive-Proof Exdemib II BT3~T6
Construction Type Compact / Remote
Operation Environment Environment temperature: -25 ° C~ + 60 ° C; Relative Humility: 5% ~90%
PUTF201 clamp-on transit-time ultrasonic flow meter utilizes transit-time principle.The transducer is mounted outside surface of the pipe without requirements of flow stop or pipe cutting.It is very simple,convenient for installation,calibration and maintenance. Small,media,large three pairs of transducers meet different size pipeline measurement demand.Plus,select thermal energy measuring function to achieve completely energy analysis.Widely applied for processing monitoring water balance test district heating balance test energy efficiency monitoring as easy installation and simple operation advantages.
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages: â?¢ Rugged, Robust, Construction withstanding to IP67.â?¢ No pressure Drop due to full bore constructionâ?¢ Maintenance free construction because of no moving parts.â?¢ Long lasting PTFE/PFA lining maximize life of meter.â?¢ Customized designs are also available as per requirement. Applications:Accumax Electromagnetic Flow-meters are used to measure various types of liquids which can be found in various industrial processes like as Acidic chemical, west water,
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
Product overview
Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection.
Technical parameters
Category Performance, parameters
Host Principle Ultrasonic time difference principle
Accuracy ±1%
Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French.
Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms)
Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC.
Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined.
Pipe inner diameter 15~6000mm
Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter)
Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves.
Temperature -30�ºC~160�ºC
Turbidity 10000ppm and small bubble content
Flow rate 0~�±10m/s
Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C
Humidity Host:85%RH Sensor protection level IP67
Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time.
Different measurement can be achieved by using the AC90~260V power adapter.
Power consumption 1W
Shell material Flame retardant ABS
Host weight 390g
Product overview
Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection.
Technical parameters
Category Performance, parameters
Host Principle Ultrasonic time difference principle
Accuracy ±1%
Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French.
Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms)
Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC.
Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined.
Pipe inner diameter 15~6000mm
Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter)
Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves.
Temperature -30C~160C
Turbidity 10000ppm and small bubble content
Flow rate 0~±10m/s
Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C
Humidity Host:85%RH Sensor protection level IP67
Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time.
Different measurement can be achieved by using the AC90~260V power adapter.
Power consumption 1W
Shell material Flame retardant ABS
Host weight 390g