Features and Benefits
Wider EPDM seat design, replaceable, its suit for different type of flanges.
ISO5211 standard top flange, suit for different operations.
Eccentric pin on the stem, not destroy structure of the stem, make sure the safety and strongth.
Lever operation BWLX: DN50~DN150.
Applicable Standards
Design standard: BS5155, EN593, API609 Flange standard: BS EN1092-2
Top flange standard: ISO5211
Face to face standard: BS EN558-1
Pressure test standard: BS EN12266-1, API598
Technical Data
Nominal diameter:DN50~DN150(2"~6") Nominal pressure: PN16
Working temperature: -5C ~ +85C Sealing test:1.1PN
Shell test:1.5PN
Suitable for: Water, ethylene glycol, non correction medium, etc.