Product Introduction
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
1. Applicable to transformers connected in Z type.
2. Two output voltages are optional and applicable to transformer whose zero-load current is relatively high.
3. Have wide testing range and the highest transformation ratio may reach 10000.
4. Automatically calculate tap position.
5. Fast speed which is only 18 seconds for three-phase.
6. Favorable repeatability.
7. Automatically save 99 data at most.
8. Flexible data processing including retrieval print transfer to U-disk delete and upload to PC computer for testing.
9. Have transformer short-circuit protection and interturn short-circuit protection functions. In case of short circuit relevant information will be displayed on the LCD screen in characters.
10. The upper computer could control the whole testing process save data .
11. Struction manual is attached to the tester providing convenience for users.
12. The tester is small and is a little bigger than a piece of A4 paper.
13. The tester is light and its weight is only 6.9kg.
GDBC-901 Multi Function Transformer Turns Ratio Tester
It is designed according to IEC76-1,IEC60044,and GB/T1094 standard.It could be applied to test the ratio of single or three phase transformer.Also the connection group of three phase transformer could be calculated with the ratio.All parameters are measured in one test for three phase transformer.
Functions
1. The voltage ratio measurement for three or singe phase transformer
2. The group vector measurement for three phase transformer.
3. The polarity measurement for single phase transformer or CT/PT
4. Voltage ratio error calculation
5. Current transformer ratio measurement
6. Excitation current measurement in ratio testing
7. Reproduction the AC test voltage from power source to reduce the effects of bad power source
8.Save the test results in the memory internal the tester
9. Print the test results by micro printer
10. Reverse connection detect unit to prevent the high voltage injected to operator
11.Over current protection unit integrated in software and hardware
12. Upload the test results to PC by RS232 and make word report by software
Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.
Our Services
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;GDBC-901 Multi Function Transformer turns ratio Meter TTR tester
AC transformer ratio tester is an innovative product are mainly applied to change than group test transformer, PT and CT polarity test, test speed, high accuracy.
Technical Indicators
Working power supply
AC22050/60 HZ
Instrument weight
3.8 kg
Instrument dimension
325 mm L 225 mm W 125 mm H
Use of temperature
-10 50
Relative humidity
90 No dew
Functional Characteristics
It has the function of blind measurement, that is, to perform variable ratio and group test when there is no connection between high and low voltage.
Based on the test of conventional transformer, Z-type transformer and PT sample, the polarity test function of CT variable ratio is added, and the application field is wider
Wide range and high accuracy, the variable ratio measurement range can reach 10,000, and the test accuracy can be guaranteed 0.3% when the maximum value is 10,000.
It has perfect protection functions such as reverse connection protection and output short circuit protection.
AC transformer ratio tester
Packaging Content
Standard accessories
1 transformer turn ratio tester
1 sets of test lines (red and black each)
1 power cord
1 print user manual
1 copy of certificate and factory test report
31535 Transformer Turns Ratio Tester Suppliers
Short on time? Let Transformer Turns Ratio Tester sellers contact you.
GF1061R portable instrument transformer turns ratio test set is mainly used for field or lab testing of current transformers and voltage transformers, it can fully automatic test CT and PT turns ratio. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. Test quickly, operation simply
Environmental conditions
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz
Voltage Range 0-100Vrms
Resolution 0.1V
Current Range 0-500mA
Current accuracy ±1mA, ±0.05% of reading ±1 digit
CT PT Turns ratio CT 0.8-50000; PT 0.8-10000
CT PT turns ratio Accuracy ±0.05%
Phase angle measurement 0-90
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
Juniper bushes can be found in eastern Europe, Bulgaria, Hungary, also in western Europe France and Spain and in north America - Canada.
This evergreen shrub grows up to 6 metres tall. It has dark green or blue needles and small flowers and berries. The berries change colour over the first few years of growth. They start off green, but after a year or two, they turn black.
Juniper is used to flavour food and drink and is the characteristic aroma in gin.
Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.
Technical index
Test range: 5A5A~25000A5A or 5A1A~5000A1A
Tested current transformer work scope: 1% 120%
Second load 2.5 VA 300VA, COS 0.8 1.0
Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S
Resistance, admittance measurement errors 5.0%
Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS
Power consumption 20 VA
Accuracy level 0.05 S level
Shape dimension mm 460 L 375 W 183H
Weight kg 10
Feature
HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device.
HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
We offer 200 tons per month of tire wire scrap from combustion of used tires. Material has no rubber left. Tire wire is loaded loose in 20' containers (28 tons each).
The Incinerated scrap or E46, is the by-product derived from the reprocessing of incinerated domestic waste.
After the combustion process, the furnace output (IBA Incinerator bottom ash) is firstly washed, magnetically separated and screened to separate any no ferrous material.
At a visual inspection, the material is fragmentized, with iron and steel parts, resulting partly cut or in shredded form.
The stock appears heterogeneous and contains all kind of cut or dismantled steel parts such as sheets, bars, frames, wires, bolts and other iron/steel household residues.
The incinerated scrap is eventually oxidized, due to the thermal and cooling treatments, that the material has been submitted to. The burnt scrap also contains minor slag parts, ash and iron oxide, due to the recovery process.
Such components are inherent and adhere to the scrap surface. The total impurities, can be sorted, but not fully removed.
The consignment does not contain any type of arms, ammunition, mines, shells, cartridges, radioactive contaminated, or any other explosive material in any form either used or otherwise.
The collected stock, is stored in open air, on cemented flooring. It can be loaded loose in 20â?? heavy duty container.
Please feel free to contact us for further details.
The Tire derived Steel or Tire Wire Scrap is a light melting scrap obtained during the shredding and granulation process of used tires.
Generally 10% - 20% of the weight of an old passenger car tyre usually consists of steel. An average shredding plant produces about 100-200 MT of steel tyre wire and its quality can vary according to technology, storing and management systems adopted by the producing plants.
We can provide tire wire scrap that still contains up to 20% rubber/fiber. This percentage is detected by manual separation test.
The material can be loaded loose in 40 HC container.
For further details, please feel free to contact us.
Plate Iron Scrap is a material that a visual inspection appears of regular shape. This by-product is formed after slag processing in electrometallurgical furnaces.
Its chemical composition is homogeneous and stable with about Fe 90% and P around 1.4%, S 0.8% and C 1.4%.
The max weight of each pieces is up to 1 ton.
The material can be loaded loose in 20 heavy duty container.
Desulphurisation Slag is an iron slag derived from the desulphurisation skimming process. This material is an iron by- product that is encapsulated in varying levels of contaminants (S,Mg,Si), but has a stable chemistry with 75 -80% chemistry.
The level of Fe% in the slag has been estimated by water displacement test.
This material con offer competitive advantages respect other metal scraps:
Price;
Stable Chemistry;
The material can be loaded loose in 20 heavy duty container.
The material is loose steel scrap processed through an incinerating plant for domestic waste followed by magnetic separation, fragmentized into pieces and consisting partly of tin coated steel cans.
At a visual inspection, the material is fragmentized, with iron and steel parts, resulting partly cut or in shredded form.
The stock appears heterogeneous and contains all kind of cut or dismantled steel parts such as sheets, bars, frames, wires, bolts and other iron/steel household residues.
The incinerated scrap is eventually oxidized, due to the thermal and cooling treatments, that the material has been submitted to. The burnt scrap also contains minor slag parts, ash and iron oxide, due to the recovery process.
Such components are inherent and adhere to the scrap surface. The total impurities, can be sorted, but not fully removed.
The consignment does not contain any type of arms, ammunition, mines, shells, cartridges, radioactive contaminated, or any other explosive material in any form either used or otherwise.
The collected stock, is stored in open air, on cemented flooring.
Due to the scrap dimensions and the material conditions, this particular scrap, should be carefully evaluated first, by the end users, to confirm its adequate recovery ratio and its suitability to be re-melted in the electric arc furnace.
Please feel free to contact us for further details
We are proposing about 2000tons of iron slag derived from the desulphurisation skimming process. This material is a iron by- product that is encapsulated in varying levels of contaminants (S,Mg,Si). In order to enhance its usability, the material is processed and screened. We can propose two specifications of Iron Slag
- European Code: 19.12.01
- Basel Code: B1010
- HS Code: 2619.0020
- Quantity: 2000 tons currently available
- Monthly quantity: 500-1000 tons depending on production
- Size: 350 1200 mm
- Fe content: from 77 to 86%
- C content: above 2,5-3%
- Bulk density: 2,8-3,4 tons/m3
- Loading type: loose in 20 (26-27 tons on average)
The level of Fe% in the slag has been estimated by water displacement test. For any further information please feel free to contact us
This Cast Iron slag is a by-product derived from the production of thermal insulating products. The byproduct is a ferrous slag which can be utilised in an electric arc furnace to produce crude steel.
Physical Description
On visual inspection, it appears to be made up of irregular shapes. Dimension: 500mm -800mm
Chemical Composition
Its chemical composition is homogeneous and stable with Fe contents in the range of 90 +/- 5% and P contents < 0.6% S around 0.15% and C% around 3.5%.
Packing: Loose in container
Loading: in 20 Container
For further information, please feel free to contact us.
31535 Transformer Turns Ratio Tester Suppliers
Short on time? Let Transformer Turns Ratio Tester sellers contact you.