PARAMETERS
Electrical parameters
Power voltage AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement 0.1ms-999999.999s
AC current output
Phase current output (effective value) 3 x 0-30A
Maximum power output 260VA/phase
Maximum parallel current output (effective value) 0-90A
Long-term allowable working value of phase current
(effective value) >10A
Allowable working time of maximum current >11s
Accuracy class
Model s40a (3*40a, 3*150v) has large lcd display and panel control facilities. No external pc is required. It can easily test many types of relays, including distance relay, df/dt relay. The rotating mouse and quick touch buttons make the operation very easy.
3*40a, 3*150v
Additional 200ma ac current source
Aux dc (24v, 110v, 220v)
4 binary inputs, 1 binary output
Locally with color lcd
(universal relay tester, relay test equipment, 3 phase relay test set, secondary injection test system)
Model t200a (250aac, 500vac, ac/dc current) can be used to test many types of relays, including high burden relay and ct.
Operation is easy, no much training is required.
High power current source for high burden relay test
Capable of testing differential relay with two independent current sources
Capable of testing directional relay with adjustable phase angle
In-built ammeter and voltmteter
120s output time at 250a
Rotating mouse control and quick control buttons
Large lcd display
Many ready test modules for automatic test applications
(secondary injection test set, relay tester, single phase relay test set, universal tester)
Since long relay testing equipment have been associated with the impression of heavy in weight and large in size. Carrying the relay testing equipment to work site is supposed to be the job for man who is physically strong. Now the automatic relay test equipment of l336i(6*15a, 4*120v) has integrated the portability with multi-functions.
6*15a, 4*120v
8 binary inputs, 4 binary outputs
Adjustable threshold (0-250v) for binary inputs
Can be upgraded to support the test of iec61850 complied relay
Weight : 9.4kg
Dimension : 256*110*395mm
124538 Relay Testing System Suppliers
Short on time? Let Relay Testing System sellers contact you.
Model pw460 (6*15a, 4*300v) can test all types of protective relays, including differential and distance relay.Further features include iec61850 interface, analog recording unit, external amplifier, gps control, energy meter and transducer test.(3 phase relay test equipment, universal test system, secondary injection test kit)
Six-channel current output, six-channel voltage output, six-channel share of dc current, six-channel dc voltage output, eight pairs of binary input, four pairs of binary output.
2.Features
Integration in the host crystal 8.4 inches true color, light weight and easy to carry
Built-in high-speed high-performance industrial computer, embedded operating system, running a stable and reliable also be connected pc testing
Panel embedded user-friendly buttons can also be an external keyboard, mouse
High-precision dac to 12 road, simultaneous output to ensure that waveform fitting of high precision, good linearity
Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can be connected electromagnetic compatibility tests
Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and test parameters of the surveillance
Exterior appearance of cabinetImported electromagnetic compatible cabinet, which is made of high-grade all aluminum alloy extruded section and has fine appearance, is selected.
Dimension of cabinet: length¡ñwidth¡ñheight¡@360mm ¡ñ195mm ¡ñ365mm
Weight of cabinetWeight of host machine ¡@¡@¡@¡@¡@¡@¡@¡@¡@ ¡@16.6kg
Warranty: 2 years
After-sale Service: Online technical support
Material: metal
Shelf Life:2 years
Instrument classification:Class II
Safety standard: none
Application: Cardiology
We are the authorized first vendor of ADTech!
KFDA CE approved,
FDA Pending
Price : Negotiable
Pre-Clinical Test Report
Accuracy
- In total samples 93.3% (14/15) - In positive samples 91.7% (11/12)
1. Pre-Clinical Test summary
1) Pre-clinical test is fulfilled by Domestic large clinical laboratory with ADTech COVID-19 IgM/IgG RAPID KIT
2) Tests are made by total 15 samples with 12 positive and 3 negative samples
3) Clinical Laboratory tested the sample with Immunofluorescence Analysis
2. Pre-clinical test result
1) Samples were tested by ADTech COVID-19 IgM/IgG RAPID KIT
2) Test result by ADTechs RAPID KIT
- 4 negatives and 11 positives results in 15 samples
3) Comparison between Immunofluorescence analysis and ADTechs RAPID KIT
- 14 test results are same(including negative and positive results) - 1 samples test result are different(Positive Negative by ADTech
For in vitro qualitative detect of Covid-19 antigen in nasal(NS) swab specimens directly from individuals who are suspected of COVID-19 by their healthcare provider within the first 5 days of the onset of the symptoms. This test is only provided for use by clinical laboratories or to healthcare workers for point-of-care testing, and not for at home testing.
1.Easy to collect samples simple operation without professional equipment.
2.The test results are available in 15 minutes, and the test results are clearly visible. 3.Convenient transportation and low price, higher accuracy.
4.Suitable for large-scale rapid screening.
Shelf life: 24 Months
Test Result time: 10 Mins
Packing: 25 Pieces per Box
A conveyor belt is a looped belt that is driven by and wrapped around one or more pulleys. It is powered by an electric motor and supported by a metal plate bed or rollers upon which the conveyor belt rests. The pulley that powers a conveyor belt is referred to as the drive pulley and has an unpowered idler pulley.
COVID-19 Rapid Test Kit IgG + IgM (Colloidal Gold) comes in packs of 40 tests and contains:
GCMS manufactures COVID-19 antigen test kit, the GENEDIA W COVID-19 Ag which is listed on the EU common list, also with GMP and ISO certifications. GENEDIA W COVID-19 Ag is unaffected based on the in-silicon analysis of the mutations in the nucleocapsid (N gene) of Omicron viruses. Letter of statement is available upon your request.
To get over COVID-19 pandemic, especially the recent Omicron breakout, currently we are doing big promotions for three kinds of COVID-19 Ag kit. All are in stock and available right away.
1. Nasopharyngeal
2. Nasal
3. Saliva
Price and Minumum Quantity
Price FOB in USD: negotiable 0.8 to 1.8Minimum Order Qty: None Pieces
Production Capacity: 3,000,000/monthPackaging: 20 Tests/kit, 30 Kits/box, 12 Boxes/pallet
Sample: Available. Sample Cost Born By Supplier
Product Model And Origin
Brand: GENEDIAModel: 643G-S (Saliva)
Seller Code: Genedia w covid 19 agHS Code: 3002.15
Standards: Ce
Competitive Advantages
Allow wider testing with fast test time (10 minutes)
All necessary materials provided / no equipment needed
Sensitivity: 93.33%, specificity: 100%
Free sample. no moq. price is negotiable. customized packing.
Other Details
20 tests / kit
24 months from the date of manufacture
2 ~ 30c(35.6 ~ 86f) available for room temperature deliver
In stock. fast delivery.
1 x Instructions for Use Manual
40 x Test Cassettes
1 x Buffer
40 x Dropper
124538 Relay Testing System Suppliers
Short on time? Let Relay Testing System sellers contact you.