PARAMETERS
Electrical parameters
Power voltage AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement 0.1ms-999999.999s
AC current output
Phase current output (effective value) 3 x 0-30A
Maximum power output 260VA/phase
Maximum parallel current output (effective value) 0-90A
Long-term allowable working value of phase current
(effective value) >10A
Allowable working time of maximum current >11s
Accuracy class

Price and Minimum Quantity

Price: $13558
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Three Phase Relay Protection Test System

May-06-22
 
Overview

The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact.



Technical parameter:

AC current output
Output accuracy Level 0.5
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 1000VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (foundation) 20 1000Hz
Harmonic number 1 20 times
DC current output
Output accuracy Level 0.5
Current output 0 10A / each phase, 0 20A / two superimposed
Maximum output load voltage 20V
AC voltage output
Output accuracy Level 0.5
Phase voltage output (effective value) 0120V
Line voltage output (effective value) 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
GOLD Member
Sep-03-10
Buyer From Mumbai, Maharashtra, India
GOLD Member
VERIFIED
Oct-02-20
Supplier From Singapore, Singapore, Singapore
GOLD Member
Nov-14-19
Supplier From Busan, South Korea (Republic Of Korea)
May-23-14
 
1.Starting test and creeping test

2.Measuring the different constant meters synchronously.

3.With the protect function of overload, short voltage circuit and open current circuit.

4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test.

5.The stored testing data can be transferred to multi-format for other program using
Jul-14-11
 
Overview:

The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.
Jul-14-11
 
Overview:

The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions)If necessary, the maximum load can be extended to Current:1,500VA and Voltage:800VA
10. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave, content<40%;3rd,5th and 7th sub-harmonic waves are superposed, content<10% each;Control of conduction angle(odd sub-harmonic wave);Control of wave group(sub-harmonic wave)
12. Starting up current: Minimum 0.3 mA, Accuracy:5%,Starting power: Accuracy:5%
13. Tests: Demand test; Frequency impact test; Voltage impact test; Second pulse clock precision test; GPS clock synchronization; Constant calibration; Combined error test; Various register checking;RS485 communication interface test
14. Energy meter testing positions:16/32(standard);3 to 40 meter testing positions also available
15. Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing, Dial testing and etc
16. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 Meter testing positions(1 rack): 2200*700*1920mm
32 Meter testing positions(2racks): 2200*700*1920mm
Cabinet: 600*800*1920mm.