Key Features:
1.Robust design with high repeatability of switching contacts
2.Over pressure protection
3.Short circuit protection
4.Maintenance free due to inductive circuit movement
Key Specifications:
1.Measurement range: 0-400 mbar to 0-6 bar
2.Operating temperature: Ambient: 0°C to +70°C
3.Protection class: IP54 per DIN EN 60529
4.Static operating pressure: 16 bar
5.Diaphragm: NBR or Viton
6.Measuring linearity: < 2.0% Full scale
7.Measuring hysteresis: < 1% Full scale
8.Operating voltage: 24 V DC/AC
9.Output signal: (0) 4-20 mA or 0-10 V, linear, proportional
10.Zero adjustment with the dial
11. 1 or 2 adjustable microswitches
12.Pressure chamber: Brass
13.Pressure connection: G 1/8, female thread
Applications areas:
1.Water pumps, lube pump monitoring
2.Pump control
3.Pipe water / liquid flow monitoring
4.Air ducts monitoring
Industrial areas:
1.HVAC & MEP applications
2.Cement plants
3.Hydro power plants
4.Manufacturing and chemical plants
Key features:
Two independent differential pressure sensors
Robust design, over-pressure protected
Selectable pressure unit
Signal output with possibility of spreading and inverting characteristic curve with any offset (optional)
Characteristic conversion of output via 3, .30 entries tablets)
Fully programmable via pc based eu03 module
Large led display
Key specifications:
1.Two independent differential pressure sensor.
2.Measuring range (of each sensor): 0 ~ 4.0 mbar up to 0 ~ 100 mbar; , ± 2.5 mbar to , ± 60.0 mbar
3.Maximum static operating pressure: 50 mbar to 500 mbar
4.Maximum safe pressure: 150 mbar to 1500 mbar
5.Straight line deviation error (max): 1.0% full scale
6.Pressure connection: g 1/8 female threads with optional cutting ring fittings for 6 or 8 mm tube
7.Operating ambient & media temperature: -10, ° c to +70, ° c
8.Protection class: ip65 per din en 60529
9.Electrical output: 4-20ma or 0-10v, 3 , ?? wire
10.Power supply: 24 v dc/ ac
11.Switching contacts: 2 sets of programmable voltage free contacts: no or nc
12.Display: 3 1/2 digit led
13.Electrical connections: two round shell multi-pin connector sockets (m12, male)
14.Material, housing: polyamide pa 6.6
15.Materials, media contact: silicon, pvc, aluminum, brass
Application areas:
1.Roll band filter monitoring
2.Vacuum system monitoring
3.Chimney draught measurement
4.Flow and control pressure monitoring
5.Surface coating system
6.Pump monitoring and control
7.Compressor monitoring and control
Industrial areas:
1.Air conditioning and ventilation systems
2.Auditorium, office, conference rooms
3.Hvac and ventilation application
4.Environment monitoring
5.Clean room and laboratory rooms
Key Features:
1.High sensitivity
2.Robust Design, over pressure protected
3.Wear resistant sensor
4.High resistance to corrosion
5.Low hysteresis
6.Large LED Display
Key Specifications:
1.Measuring range:
0 ~ 6 mbar to 0 ~ 60 mbar, max static pressure: 32 bar
0 ~ 32 mbar to 0 ~ 320 mbar, max static pressure: 140 bar
0 ~ 130 mbar to 0 ~ 1300 mbar, max static pressure: 140 bar
0 ~ 500 mbar to 0 ~ 5000 mbar, max static pressure: 140 bar
0 ~ 2 bar to 0 ~ 20 bar, max static pressure: 140 bar
2.Linearity: < 0.1 %
3.Hysteresis: < 0.1 %
4.Temperature coefficient: < 0.5 % / 10° C
5.Operating ambient temperature: -10° C to +70° C
6.Operating media temperature: 0° C to +80° C
7.Protection class: IP67
8.Electrical output: 4-20mA
9.Power supply: 24 V DC
10.Pressure connection: 2 x 1/4â?³ NPT
11.Display: analog display with 0 ~ 100% scale. digital display (only with communication module option -K installed)
12.Electrical connections: internal terminal block
13.Material (media contact): Stainless steel 316 L (1.4404)
14.Electronic housing: Aluminum, surface coated
15.Marking / approval: CE mark, complies with EMV specifications EN 50082-1 and EN 50082-2
Application areas:
1.Filter technique
2.Precision measurements in air conditioning conduits
3.Clean room pressure compensation
4.Burner vacuum measurement
5.Circulating air controlling in furnaces
Industrial areas:
1.Air conditioning and ventilation systems
2.HVAC and ventilation application
3.Environment monitoring
4.Clean room and laboratory rooms
Key Specifications:
1.Measuring range: 0 ~ 25 Pa to 0 ~ 1000 Pa
2.Maximum static operating pressure: 1.0 bar
3.Maximum safe pressure: 1.7 bar
4.Straight line error (max.): 1.0 % Full scale
5.Pressure connection: screw clamp connectors (aluminum) for 6/4 mm or 8/6 tube
6.Repeatability: 0.1 % full scale
7.Operating ambient & media temperature: -10° C to +70° C
8.Protection class: IP65 per DIN EN 60529
9.Linearity: < 2% Full scale
10.Electrical output: 4-20mA linear, 2 â?? wire
11.Power supply: 24 V DC
12.Material, housing: Polyamide PA 6,6
13.Materials, media contact: Silicon, PVC, aluminum, brass
Application areas:
1.Filter status / condition monitoring
2.Precision air duct measurement
3.Clean room pressure balance monitoring
4.Burner air feed low pressure detection
5.Oven air feed control
Industrial areas:
1.Air conditioning and ventilation systems
2.Auditorium, office, conference rooms
3.HVAC and ventilation application
4.Environment monitoring
5.Clean room and laboratory rooms
Key Features:
1.Explosion proof ATEX certification with CE Ex II 3 G c EEx nA IIC T4 for DE38###R and CE Ex II 3 D c IP65 T125 for DE38###S
2.Robust design with high repeatability
3.Over pressure protection
4.Wear free non-contact LVDT sensing element, thus no maintenance
5.Signal output with possibility of various characteristic curve
6.Characteristic conversion of output via 3?¦.30 entries table
7.Complete set-up of all parameters and print out by using optional PC programming interface EU03
8.Measuring range: 0-400 mbar to 0-1600 bar
9.Operating temperature: Ambient: -10°C to +70°C; Media:-10°C to +70°C
10.Protection class: IP65 per DIN EN 60529
11.Output: 0/4-20mA, 0-10 VDC
12.Display: 3 ½ digit LCD
Applications areas:
1.Monitoring of compressors, filters and vacuum systems
2.Measurement of differential pressure between supply and return fuel lines in heating & 3.cooling systems (Chillers)
4.Flow measurement ?? lubricants, oil, hydrocarbons, water, gases
5.Control pressure ?? air, gases, oil, water, lubricants
6.Level measurement- tank, container of lubricants, oils, water, liquids etc
Industrial areas:
1.Cement plants
2.Nuclear plants, coal or gas fired power plants
3.hydro power plants
4.Manufacturing and chemical plants
6255 Dp Transmitter Suppliers
Short on time? Let Dp Transmitter sellers contact you.
Key Features:
1.Rugged, wear & tear resistant sensor design
2.High corrosion resistant
3.Rinsable pressure chambers
4.Suitable for aggressive media
5.Unaffected by vibration, radiation, dirt etc
Key Specifications:
1.Measuring range: 0 ~ 100 mbar to 0 ~ 25 bar
2.Measuring principle: fluid filled membrance / diaphragm system with inductive pickup system
3.Maximum static pressure: 100 bar
4.Measuring span: can be set steplessly from 20% ~ 100% of the full scale
5.Measuring start: can be set steplessly from 0% ~ 100% of the measuring range when the characteristic curve falls (switchable) can be set steplessly from 100% ~ 0% of the full scale
6.Temperature or measuring media: -10 °C to +70 °C
7.Ambient temperature: -10 °C to +70 °C
8.Electromagnetic compatibility: DIN EN 61000-6-2 (interference resistance), DIN EN 61000-6-4 (emitted interference)
9.Output: analog 0/4-20mA, with characteristic curve of linear, rising or falling (switchable)
10.Measuring membrane: Nickle-Beryllium / Duratherm
11.Fluid Filling: Baysilone oil PD 5
12.Measuring chamber, separating membrane: Chromium nickel steel 1.4571 (AISI 316Ti)
13.Protection: IP as per EN 60529 / IEC 529
14.Product qualification: in compliance with KTA 3505
Application areas:
1.Water and effluent treatment plants, and other filtration applications
2.Filter condition monitoring
3.Flow measurement of steam and hot water, using differential pressure flow sensors, in 4.remote heating systems
5.Pump Control dependent on differential pressure in block unit heating power stations
Application areas:
1.Nuclear power plants
2.Manufacturing and chemical plants
3.Marine, shipping application
4.Onshore and offshore area
5.Petrochemical, solvent industry
6.Sewage, effluent treatment plants
Moisture less than 5%, ABS stock : 300~500tons
It is virgin from LG chemical, No data in the MSDS
Do not matter at virgin powder. Can make extrusion or injection both.
A&S Transmitter Co., Ltd. provide all types of Azbil/Yamatake pressure transmitters:
Yamatake Pressure Transmitter AT9000
Advanced Transmitter Model GTX
Examples of model we can offer:
Yamatake Temperature Transmitter ATT60,
Yamatake Temperature Transmitter ATT70,
Yamatake Temperature Transmitter ATT 90,
Yamatake Temperature Transmitter ATT9X,ect.
A&s transmitter co., ltd. Provide all types of fuji pressure transmitter
Fuji pressure transmitter model fkh
Fuji pressure transmitter model fka
Fuji pressure transmitter model fkg
Fuji pressure transmitter model fkp
Fuji pressure transmitter model fkb
Fuji pressure transmitter model fkw
Fuji pressure transmitter model fkc
Fuji pressure transmitter model fkd
Fuji pressure transmitter model fkx
A&s transmitter co., ltd. Provide all types of emerson/rosemount pressure transmitters
Rosemount pressure transmitters 3051cd
Rosemount pressure transmitters 3051cg
Rosemount pressure transmitters 3051ca
Rosemount pressure transmitters 3051tg
Rosemount pressure transmitters 3051ta
Rosemount pressure transmitter 3051s
Rosemount pressure transmitters 3051l
Etc.
Besides rosemount 3051 pressure transmitters, we can also help you with other rosemount transmitters as follows:
Rosemount 2051 pressure transmitters
Rosemount 1151 pressure transmitters
Rosemount 5300 series pressure transmitters
Rosemount 5400 series pressure transmitters
Rosemount 3100 series pressure transmitters
Rosemount temperature transmitters.Etc.
overview
The diaphragm of the differential pressure level transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It uses a filling fluid such as silicone oil to transmit pressure between the transmitters.
The HR3051-LT differential pressure level transmitter be used for measuring the level, density, pressure, and flow of a liquid, gas, or vapor and converts it into a 4-20 ma DC HART current signal output. The RP2001 can also communicate with the RST375 handheld te
rminal or the RSM100 Modem for parameter setting, process monitoring, and more. The measuring range of the HR3051-LT differential pressure level transmitter (when not moved) is 0-1kPa~2MPa, and the rated pressure of the liquid level flange is: 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi or 600psi.
Working principle and structure
The HR3051-LT differential pressure level transmitter consists of a HR3051-DP differential pressure transmitter and a soldered liquid level flange. Its working principle is the same as HR3051-DP type differential pressure transmitter (see HR3051-DP type differential pressure transmitter technical specification), except that the pressure transmission path on the positive pressure side is slightly different: the pressure acting on the high pressure side is firstly The diaphragm and filling liquid on the liquid level flange pass through the transmitter body and finally reach the high voltage side of the measuring sensor.
Comparison of range code and range limits
Range code Minimum range Maximum range Rated pressure (maximum)
B 1kPa 6kPa Rated pressure of the liquid level flange
A&S Transmitter Co., Ltd. provide all types of Yokogawa Pressure Transmitters:
Yokogawa Y/11AL Pneumatic Absolute Pressure Transmitter,
Yokogawa P10 series pneumatic pressure transmitters,
Yokogawa DPharp EJX series pressure transmitters,
Yokogawa DPharp EJA-E series pressure transmitters,
Yokogawa DPharp EJA series pressure transmitters,etc.
Model:
Yokogawa Temperature Transmitter YTA110
Yokogawa Temperature Transmitter YTA310
Yokogawa Temperature Transmitter YTA320
Yokogawa Temperature Transmitter YTA70
Yokogawa Temperature Transmitter YTA50