Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF004SACH
CDG11
APPLICATION - E/F
BURDEN - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126-795
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF004SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 795
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126793
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
GBCDG11AF011SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF011SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
2125 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF012SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF012SA(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9125671
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
GBCDG11AF012SCCH
IDMT OVER CURRENT RELAY
Technical Specifications
Relay Model No CDG11AF012SCCH
Relay type CDG 11
Case size 1D V 10T
Application O/C
Current setting 0.5 to 2 amps
Frequency 50 Hz
Contacts 2 N/O 2 N/C H/R
Output contacts 2 N/O 2 N/C H/R
Taps Std
Burden 3 VA
Operating time 1.3 Secs
C.T.Secondary 1 amps
Flag Yes
Mounting Flush
Name Plate RFG9125 771
Outline Diagram MFJ 012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF013SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125696
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
GBCDG11AF013SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SCCH
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 796
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF014SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : - CDG11AF014SA(M)
CDG11
APPLICATION - E/F
BURDEN /D.M.T - 3VA /1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125-795
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF014SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF014SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 795
Outline Diagram MFJ012
Wiring Diagram MADZ802-64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125693
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF016SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF016SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125692
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF016SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF016SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA /1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 792
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
GBCDG11AF018SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Relay Model No CDG11AF018SACH
Relay type CDG 11 Special
Case size 1D V 10T
Application E/F
Current setting 0.2 to 0.8 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Burden 3 VA
Operating time 1.3 secs
Taps Std
Frequency 50 Hz
Flag Yes
Mounting Flush
Name Plate RFG9125 793
Outline Diagram MFJ 012
Wiring Diagram MADZ 802.66-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF106SACH
SELF-POWERED INVERSE TIME O/C ORE/F 60HZ
Technical Specifications
Model No CDG11AF106SACH
CDG11
Application - E/F
Burden / D.M.T - 3Va / 3 Secs.
C.T. Secondary - 1 Amp
Case Size - 1D V 10T
Contacts - 2 N/O S/R
Current Setting - 0.1 - 0.4 Amps.
Flag - Yes
Mounting - Flush
Taps - STD
Frequncy - 60 Hz
Note:-In NamePlate write 60 Hz in place of 50 Hz
Name Plate RFG9126792
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
Alstom Gbcdg11af8101kch
Idmt O/c Relay, Bss Curve,ac Series Trip
Technical Specification
Model No. Cdg11af8101kch
Application O/c
Burden / D.m.t 3va / 3 Secs.
C.t. Secondary 5 Amp C.t.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 2 N/c H/r
E/f or U/v Setting Not Aplicable
Flag Yes
Frequency 50 Hz
Mounting Flush
O/c or O/v Setting 2.5 - 10 Amps.
Name Plate-1 Rfg9126674
Outline Drawing Mfj012
Wiring Diagram Madz821-17
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF8104KCH
INV.TIME O/C OR E/F RELAY FOR AC SERIES
Technical Specifications
Model No : CDG11AF8104K(M)
CDG11 S/T
APPLICATION - E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126695
Outline Diagram MFJ012
Wiring Diagram MADZ821-17
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF9007ACH
INVERSE TIME E/F RELAY MULTI-AUX-VOLTAGE
Technical specification
Relay model no CDG11AF9007ACH
Relay type CDG 11
Case size 1D S/E
Application E/F
Current setting 1 to 4 amps
C.T.Secondary 5 amps
Taps Std
Burden 3 VA
Operating time 3 secs
Frequency 50 Hz
Aux.voltage vdc 30-50 / 100-125 V
220-250 V dc
Contacts shunt 2 N/O S/R
Flag Yes
Mounting Type Flush
Name plate RFG9126 796
Outline drawing MFJ 012
Wiring diagram MADZ 802.26-1
2125 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
See what buyers and suppliers are discussing in Temperature Controllers Indicators import export community