Technical Specifications
Model No : CDG11AF011SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1

Price and Minimum Quantity

Price: $1500
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Self-Powered Dir. Inverse Time O/c Or E/

VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF001SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF001SACH
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5-10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF004SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 795
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126793
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF013SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125696
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
GBCDG11AF013SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SCCH
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 796
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF014SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF014SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 795
Outline Diagram MFJ012
Wiring Diagram MADZ802-64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125693
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF016SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF016SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA /1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 792
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1

Verification Status