Please click here to check who's online and chat with them.

Find Verified Optical Fiber Cables Suppliers, Manufacturers and Wholesalers

Nov-28-12
 
Features
Rugged construction providing shock, dust and moisture resistance
Dual monitor position with automatic image orientation
Automatic arc calibration and iber identiication
User-selectable iber clamping method sheath clamp or fiber holders
Auto-start tube heater feature
Color LCD display with anti-relective coating for excellent visibility in bright sunlight
Simultaneous battery charge and splicer operation
Long life battery (up to 160 splice/heat cycles per charge)
Detachable work table incorporated into the transit case
Data and video download software and splicer upgrade software included; software upgrades through PC application via the internet
Green friendly RoHS & WEEE compliant

Specifications
Model FSM-60S
Applicable Fibers SM(G.652),MM(G.651), DS(G.653),NZ-DS(G.655)
Cladding Diameter 80 um to150 um
Coating Diameter 100 um to 1000 um
Fiber Cleave Length 8 to 16mm with 250um coating diameter, 16mm with 900um coating diameter
Typical Average Splice Loss 0.02dB with Sm, 0.01dB with mm, 0.04dB with DS, 0.04dB with NZDS
Splicing Time Typical 9 seconds with standard single-mode fiber
Arc Calibration method Automatic, real-time and by using results of previous splice when in AUTO mode, manual arc calibration function available
Splicing modes 100 preset and user programmable modes
Splice Loss Estimate Based upon dual camera core alignment data
Storage of Splice Result Last 2000 results to be stored in the internal memory
Fiber Display X or Y, or both X and Y simultaneously. Front or rear monitor display options with automated image orientation
Magnification 300X for single X or Y view, or 187X for X and Y view
Viewing method Dual cameras with 4.1 inch TFT color LCD monitor
Operating Condition 0 to 5,000 m above sea level, 0 to 95 % RH and -10 to 50°C respectively
mechanical Proof Test 1.96 to 2.25N
Tube Heater Built-in tube heater with 30 heating modes; auto-start function
Tube Heating Time Typical 30 seconds with FP-03 sleeve, 35 seconds with FP3(40), 35-55 seconds with Fujikura micro sleeves
Protection Sleeve Length 60mm, 40mm, micro
Splice Cycles with Battery Typical 160 cycles with power save functions activated
Power Supply Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-11, 13.2V DC with BTR-08 battery
Terminals USB 1.1 (USB-B type) for PC communication.
Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater
Wind Protection Max. wind velocity of 15m/s. (34 mph)
Dimensions (W × D × H ) 136 × 161 × 143 mm; 5.3 × 6.3 × 5.6 inches
Weight 2.3 kg (5.1 lbs) with AC adapter; 2.7 kg (5.9 lbs) with BTR-08 battery.
Nov-14-12
Supplier From Shenzhen, Guangdong, China
 
Fiber patch cord
Fiber optic accessories.
Aug-06-12
Supplier From Brunswick, Ga, United States
 
Bulk fiber cables
Panels and connectivity
Assemblies and patch cables.
Aug-30-12
 
Model: gztgl-12


Fiber diameter: 10.0mm
Fiber material: pmma

Cable diameter: 12.0mm
Cable material: transparent pvc

Solid core side glow cable is produced by jacketing with transparent pvc cover for uv protection.


100m/spool
Jul-17-12

Fiber Optic Patch Cord

$1.50
MOQ: Not Specified
 
Fiber optic patch cord

Applications
1. CATV
2. Metro
3. Test equipment
4. Active device termination
5. Local area networks (lans)
6. Premise installations
7. Telecommunication networks
8. Data processing networks
9. Wide area networks (wans)

Features
1. Low insertion loss and high reflection loss
2. Good durability
3. Compliant standard: IEC & ROHS
4. Good exchangeability
5. High temperature stability
6. Customization, I. E.: print company name on the connector and adapter.


200 piece per carton,
0.0587 cbm per carton
12kg per carton.
2097 Optical Fiber Cables Suppliers
Short on time? Let Optical Fiber Cables sellers contact you.
Jul-10-12
 
Features:
1. FTTH project usable
2. Field installable
3. Fast, easy, accurate
4. Cost effective
5. Portable
6. Installation less than 2 minutes
7. Reliable and superior optical performance
8. Cable Tensile test complies with Telcordia GR-326-CORE

Application:
1. Distribution frames
2. Maintenance or emergency restoration of fiber networks
3. Patch panels
4. FTTH Outlets
5. Field word.
Jul-10-12
 
Features:
Uitra-end insertion loss and associated loss of polarization
Goodspectral uniformity
Wide wavelength bandwidth
A wide range of working environment
High reliability
Small size
Applications:
Can be widely used for FTTX
Passive Optical Network (OPN)
Cable TV Network (CATV)
Other optical signal splitter system
Standard compliance:
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
YD/T1117-2001

Performance Index
Type
Unit
1 X 2
1 X 4
1 X 8
1 X 16
1 X 32
1 X 64
Optical Fiber diameter
um
9/125 um¡¨º¡¡ìsmf-28¡¨º©
wavelength
nm
1260~1620
Insertion Loss
dB
¡¨º¼3.8
¡¨º¼7.3
¡¨º¼10.6
¡¨º¼13.7
¡¨º¼16.9
¡¨º¼21
Uniformity
dB
¡¨º¼0.6
¡¨º¼0.8
¡¨º¼1.0
¡¨º¼1.4
¡¨º¼1.6
¡¨º¼1.9
PDL Loss
dB
¡¨º¼0.20
¡¨º¼0.20
¡¨º¼0.30
¡¨º¼0.30
¡¨º¼0.30
¡¨º¼0.35
Directivity
dB
¡¨º¾55
Return Loss
dB
¡¨º¾50
Operation Temperature
¡æ
-40~ +85
Storage Temperature
¡æ
-40 ~ +85

Type
Unit
2X 2
2 X 4
2 X 8
2X 16
2 X 32
2 X 64.


ABS box.
Jun-05-12
 
BV electirc cable (60227 IEC 05)
1) Conductor: Copper (70¡ã C single core solid)
2) Insulation: PVC
3) Sheathed: Non
4) Rated voltage (U0/U): 300/500V
5) Standard: IEC60227-2003 or as per the customers' requests
6) Purpose: For internal wiring
7) The max continuous operating temperature of the conductor: 70¡ã C
8) The ambient temperature for the cable installation: 0¡ã C
9) The bending radius of the cable: (D=cable outer diameter, R=bending radius)
A. D 25mm, R 4D
B. D>25mm, R 6D"

10) Specifications & Technical Data :
Nominal
cross-
section Con-
ductor
Type Insulation
Thickness Average
Overall
Diameter Approx
Weight Max
Conductor
Resistance
¦¸ /km Min
Insulation
Resistance
mm 2 mm mm kg/km without
coat metal
coat M¦¸ /km
0.5 1 0.6 2.4 8.08 36 36.7 0.015
0.75 1 0.6 2.6 10.55 24.5 24.8 0.012
1 1 0.6 2.8 13.28 18.1 18.2 0.011

HS Code: 8544492100
Productivity: 600km/Month
Unit Price: Negotiable
Shipment Terms: FOB
Payment Terms: L/C,T/T,negotiation
Minimum Order: 1000 Meter
Price Valid Time: From Jan 09,2012 To Jan 09,2013
Insulation Material: PVC
Conductor Type: Stranded
Conductor Material: Copper
Application: Inner House Wiring
Type: Insulated
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe.


100m/roll 3roll/bags.
May-30-12
Supplier From Icerenkoy, Istanbul, Turkey
 
Control :by technician
Needed air :10.5 bar 12 m³/min.(duct 40 hdp)
Air engine : double effective, 740 watt (2 pieces)
Needed air for engines : 6 bar-1.6m³/min.
Cable installing velocity : 0, 30, 50m/min.
Lay down power :80~85 kg.
Dimensions (width x lenght x height) : 365mm x 330mm x 540mm
Weight of machine :46kg.


In chrome box.
Aug-23-11
 
Specifications:
1) UTP Cat5, Cat5e cable, utp Cat6 cables are available
2) CCC,CE,CB,RoHS approved
3) Sale in Asia,Europe,Africa etc

Structure:
1. Conductor:
Material: solid or stranded copper
Diameter: 23AWG
Construction 1/0.57,0.02mm

2. Insulation:
Material: HDPE
Thickness: 0.24,0.05mm
Diameter: 1.04,0.06mm
Color: optional
Elongation rate: Min.300%
Tensile strength: Min.1.22kg/mm2

3. Jacket:
Material: PVC
Thickness: average:0.50mm Min. at any point:0.40mm
Diameter: 6.3,0.3mm
Color: to your option
Elongation rate: Min.125%
Tensile strength: Min.1.41kg/mm2

4. Rip cord& meter mark: optional
5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC

Application:
1) Data transmission cable for structure laying electric wires
2) For figure, voice, data and video signal transmission
3) Suitable for all of D-level lines and Cat6 application
4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring,
TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s.



Carton.
Aug-23-11
 
Specifications:
1) Utp Cat5, Cat5e cable, utp Cat6 cables are available.
2) CCC, CE, CB, RoHS approved.
3) Sale in Asia,Europe,Africa etc.

Structure:
1. Conductor:
Material: solid or stranded copper
Diameter: 23AWG
Construction 1/0.570.02mm

2. Insulation:
Material: HDPE
Thickness: 0.240.05mm
Diameter: 1.040.06mm
Color: optional
Elongation rate: Min.300%
Tensile strength: Min.1.22kg/mm2

3. Jacket
Material: PVC
Thickness: average:0.50mm Min. at any point:0.40mm
Diameter: 6.30.3mm
Color: to your option
Elongation rate: Min.125%
Tensile strength: Min.1.41kg/mm2

4. Rip cord& meter mark: optional
5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC

Application:
1) Data transmission cable for structure laying electric wires
2) For figure, voice, data and video signal transmission
3) Suitable for all of D-level lines and Cat6 application
4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring,
TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s.



Standard Lot Size
Nov-07-11

Flexible Cable

$1
MOQ: Not Specified
 
Conductor: Plain annealed flexible copper complying with BS6360, class 5
Insulation: PVC (polyvinyl chloride)
Outer sheath: PVC (polyvinyl chloride). Color: Grey
Voltage Range: 300/500 volts, Test 3000 volts
Core Identification: Black cores with white numbers with green/yellow core.
Operating temperature:- 20° C to + 70° C in fixed condition,
- 5° C to + 70° C in mobile condition.
Bending Radius:10 x Overall Diameter.
The type flexible control cable, sometimes referred to as PVC/PVC control cable is ideal in fixed and mobile conditions. For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning.

100m/roll.
Nov-07-11

Nym-J Cable

$1
MOQ: Not Specified
 
Voltage rating: 300/500V
Application:For industrial and wiring installation in air or in cable management systems, embedded in masonry or cement. Not suitable for laying in ground.
Construction:Solid or stranded plain copper conductors to VDE0295. PVC insulation, PVC sheath.
Insulation colours: Three Core: Green/Yellow, Blue, Brown.
Sheath colour: Grey
Minimum bending radius: 4D
Maximum conductor temperature: 70C.


100m/roll, roll in carton.
Nov-07-11

Control Cable

$1
MOQ: Not Specified
 
Application:
Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.

Standards:
Generally to BS6500, VDE0250
Conductor: Class 5 flexible plain copper conductors
Insulation and sheath: PVC (Polyvinyl Chloride)
Sheath Colour: Grey
Voltage Rating: 300/500V
Temperature Rating:Fixed: -35C to + 70CFlexing: -5C to + 70C
Minimum Bending Radius:10 x overall diameter

Core Identification:
Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.
RoHS Compliant.

100m/roll.
Nov-07-11
 
Conductor: Bare stranded copper, IEC 60228, Class 5.
Insulation: PVC (polyvinyl chloride)
Outer sheath: PVC (polyvinyl chloride).
Screen: Polyester tape, TWCB (Tinned Wire Copper Braid)
Operating temperature: - 40° C to + 70° C in fixed condition, - 15° C to + 70° C in mobile condition.
Bending Radius:15 x Overall Diameter.

Flexible data transmission control cable with a Tinned Copper Wire Braid (TWCB). Used in electronic control systems, in voice frequency, signal and data transmission. LiYCY (CY) can be used as a connection cable in office machinery and measurement devices. Suitable for fixed and flexible applications with unrestricted mobility, without forced movement control and without exposure to tensile load. Because these cables have a copper screening they are ideally suitable for interference free transmissions.


100m/roll.
Nov-07-11
 
Technical Information
Voltage Working : 300 / 500V to BS7919 & BS6500
Temperature range : Flexing : -25oC to +60oC
Static : - 40oC to + 60oC
Bending radius Flexing : 15 x cable diameter
Static : 6 x cable diameter
Stranding of fine copper wires plain or tinned
Rubber insulation :Colored cores acc. to VDE 0293
More than 2 cores with one green / yellow earth conductor.

Conductor Identification:
Two Core - Brown and Blue
Three Core - Brown, Blue and Green / Yellow
Four Core - Brown, Grey, Black and Green / Yellow
Five Core - Brown, Blue, Grey, Black and Green / Yellow
Application of H05RR-F: For connection of electrical appliances when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is minimal physical damage expected.

100m/roll.
Aug-09-11
Supplier From Gwalior, Madhya Pradesh, India
 
XLPE Cable, PVC Cable, Copper Cable, ABC Cable, AAC and ACSR Conductors.

Packed in various sizes/weight of wooden/steel drums.
Apr-28-10
 
Fiber optical cable.


Tray 100 100 pcs 13.5*27*3 cm
Inner box 20 tray/box 2000 pcs 29*29*22 cm
Outer box 2 inner box/outer box 4000 pcs 60*31*25.8 cm.
Aug-14-07
 
PVC Insulated & Sheathed Power Cables
Standards: IEC60502, GB/T12706-2008
Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity.

Service Conditions:
1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2
2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
May-11-11
 
1, Use:
Aluminum wire and ACSRs structures are simple. They are easy to set up and maintenance. The cost is low in building the lines. The transmission capacity is large. They are also convenient to cross special geographical conditions, such as rivers, valleys and so on. So the products are applied for various voltage levels of overhead transmission and distribution lines.

2, Model
Model Name
cross sectional area

LJ
aluminum wire
16-500

LGJ
ACSR
10-240



GB/T1179-1999 "Round wire concentric lay, stranded conductors" standard is equivalent to IEC61089-1991 standard. According to user needs. Our company can produce the aluminum wire and ACSR on the basis of ASTM, DIN, BS and other standards. Note: the products model and code in GB1179-83 of the new and old standard still has a large number of users and market, it can be used as non-standard£¨or users special needs£© when ordering the products.
3, material standards:
Aluminum wire and ASCR with a hard steel core execute GB/T17048 (identical with IEC60889 standard). ACSR with galvanized steel execute IEC60888 standards. According to users needs, we can produce the production on the basis of the user's material standards and requirements.
4, product performance: the electrical properties of aluminum wire and ACSR should be showed as the resistance at 20 ¡æ. Hard aluminum wire's resistance is not greater than the international standard value 0.028264¦¸.mm2 / m. ACSR has three intensity levels: general intensity level ACSR, high strength ACSR and extra high strength grade level ACSR.
5, product maintenance: the product should avoid squeezing and bumps during handling and transportation. Cables should not be laid flat during the transportation and storage. Product should take moisture measures during storage.
2097 Optical Fiber Cables Suppliers
Short on time? Let Optical Fiber Cables sellers contact you.
See what buyers and suppliers are discussing in Optical Fiber Cables import export community