Please click here to check who's online and chat with them.

Find Verified Water Treatment Chemicals Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Jakarta   Surabaya   -  
Oct-14-15
Supplier From Jakarta, Dki, Indonesia
Jan-31-05
Supplier From Jakarta, Indonesia
Oct-31-06
Supplier From Tangerang, Jawa Barat, Indonesia
Feb-05-20
Supplier From Batam, Riau, Indonesia
Oct-06-16
Supplier From Tangerang, Banten, Indonesia
66 Water Treatment Chemicals Suppliers
Short on time? Let Water Treatment Chemicals sellers contact you.
Mar-27-16
Supplier From Tangerang, Banten, Indonesia
Oct-21-21
Supplier From Bandung, West Java, Indonesia
 
We Produce multifunctional Bacterial liquids that can be utilized among others in sewage treatment, RDF manufacturing, organic fertilizers, additional animal feed and so on

Our Bacterial Uses:
Azotobacter sp
Bacillus sp
Saccharomyces

APPLICATIONS OF OUR BACTERIAL LIQUIDS:
1. Waste Processing (to make RDF)
2. Sewage Treatment
3. Agriculture & Plantation
4. Livestock
5. Fisheries

We Provides to worldwide wholesale businesses
We have a warehouse that keeps the room temperature stable and in accordance with procedures so that the quality of the product is maintained.
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
LC 100 ideal to remove not only calcium carbonate &
calcium phosphate deposits but also calcium sulfate
and barium sulfate as well.
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
Application LC 231 is a special blend of volatile acids,
corrosion inhibitors & dispersing agents. It effectively
removes scale and soil of carbonate nature from metal
and other surfaces. LC 231 is an excellent additive for
the LC 233 for the initial removal of the carbonate based
scale and effectively bring down cost by reducing the
amount of other descalers. Its acid formulation dissolves
lime scale and rust deep down with the selective inhibitors
protecting metal surfaces.
Application
Spray or brush on surfaces. Clean surface free from rust, soil and dirt. Apply
LC 231. Allow to stand for 2-5 minutes, scrub thoroughly and re-apply. Repeat
and then flush off with water. Flush with water until all scale is removed. Add
with other descaler like LC 232 & LC 233 for stubborn and difficult to remove
scales. Cannot be used alone.
Dosage
Dilute one part of LC 231 with up to 10 parts of water depending on the
thickness of scales.
Handling & Precaution
Irritating to eyes and skin. Protective clothing and eye protection should be
provided and worn. After contact with skin, wash immediately with plenty of
water. In case of eye contact irrigate thoroughly with water for at least 15
minutes. Seek medical advice.
Packaging
Available in pail of 20 lt.. Can also be custom packaged.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Lc 250 is a water displacing anti corrosion compound
Used to prevent rust on metal surfaces with unlimited
Applications in the fields of marine, automobile, aviation
Farming, etc.
Lc 250 creeps along surfaces and into cracks to
Lubricate, loosen frozen parts and displace water. The
Loosened rust can easily be removed. The displacing
Mechanism works by preferential wetting. The attraction,
Of the preventative that of water, thus displacing water.
Application
Apply lc 250 to metal surfaces either by brushing or dipping.
When dipping is used, allow excess chemical to drip prior to
Storage.
Handling & precaution
Avoid unnecessary skin contact. Prolonged contact may cause
Irritation.
Packaging
Available in pail of 20 lt.. Can also be custom packaged.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Clean the floor with a perfect and refreshing fragrance.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Remove impurities in the form of carbon from the surface of the oven, cooking utensils, sewer, ventilation, and other places where carbon deposition thickness is usually attached.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Lc 106 is an ideal steam line anti corrosion treatment for
Boilers. It is a highly concentrated, alkaline product.
Eliminates corrosion in the outgoing steam lines and
Stabilizes ph in the condensate.
Application
For use with boilers which requires anti-corrosion treatment in the steam lines. It
Disperses with steam and forms a protection film on the inner surfaces of the
Steam pipes. Injected directly into the boiler by means of a proportioning pump.
It is environmentally safe. Do not use in boilers where steam
Contacts food.
Dosage
Initial : 1 quarts per 100 gallons or 1 : 400
Maintenance: 1 quart for every 200 gallons of make-up water or 1 : 800
Maintain ph of 7.5 – 8.5 in the steam line of system. Maintain sulfite of 30 – 60
Ppm along with lc 106. Maintain the conductivity less than 5000 mho/cm.
Handling & precaution
Lc 106 is an alkaline product and should be handled with care to prevent
Personal injury. Wear protective clothing and eye protection. In case of contact
With skin, immediately flush with water. In case of contact with eye, flush with
Water for 15 minutes and obtain immediate medical attention. Triple rinse used
Cans before reuse or disposal.
Packaging
Available in pail of 20 lt.. Can also be custom packaged.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Lc 120 is a product which effectively prevents scale and
Corrosion in cooling towers having very soft waters which
Are more corrosive, have a rysnar index over 7 and
Calcium 25 – 75 ppm in the make-up water. It is an
Excellent dispersant for calcium phosphate, iron oxides
And clay. This product is used where heavy metals and
Zinc is not allowed in effluent waters. Lc 120 is a
Hydroxy-phosphonoacetic acid with polymers and copolymers
To control scaling. It also has inorganic
Phosphate and sodium tolytriazole to prevent corrosion
And pitting of all metal surfaces.
Application
Injected directly into the circulating pipe upstream from the condenser.
Cycles of concentration will vary from 5 – 20 as a probable upper limit. For
Higher limits consult our laboratory.
Dosage
Feed lc 120 from a chemical mix tank or directly from the drum by means
Of a proportioning pump at the rate of 0.5 pound / 1, 000 gallons of make-up
Water. Adjust the dosage to maintain 5 – 10 ppm of orthophosphate in the
Circulating water. A ph of 8.0 – 8.5 must be maintained.
Handling & precaution
Protective clothing and eye protection should be worn. In case of skin
Contact, immediately flush thoroughly with plenty of clean water. In case of
Eye contact, flush with copious of amounts of water for 15 minutes and
Obtain immediate medical attention.
Packaging
Available in pail of 20 lt.. Can also be custom packaged


.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Lc 143 is specially formulated for use in systems that are
Constantly exposed to air, such as vented air to pressurized
Systems providing corrosion protection even in systems that
Are not tight. It reduces maintenance costs by keeping
Exchangers, air handling units and zone valves free of
Corrosion clogs. It also reduces corrosion insulation and
System damage. Lc 143 contains boron nitrate that protects
Against oxygen and acid attack, works well in any closed
System. Recommended for any hot water boiler or recirculating
Or closed loop system.
Application
Can be added to a system either manually or with a pot feeder. If the
Treatment dosage is less that the capacity of feeder, fill up the feeder with
Tap water to prevent air on treatment. Not to be used in electric
Steam boilers.
Dosage
For chilled water circulating system : for initial or maintenance treatment,
Add 1 gallon of lc 143 for each 200 gallons of chilled water. The treatment
Level is easily tested with the drop titration nitrite test kit.
Handling & precaution
Irritant. Avoid contact with eyes. Avoid repeated or prolonged contact with
Skin. If contact occurs, flush with water. If eye contact occurs, flush with
Water for 15 minutes. Seek medical attention. Keep out of reach of
Children. Refer to material safety data sheet for more specific procedures.
Packaging
Available in pail of 20 lt.. Can also be custom packaged.
Oct-10-16
Supplier From Tangerang, Banten, Indonesia
 
Lc 253 is an alkaline concentrated food grade product
Designed for “passivating“ as well as neutralizing the
Metal surfaces that is succeptable to corrosion. Lc 253
Is also an alkaline formulation of phosphate, polymeric
Dispersants and corrosion inhibitors. It is designed to
Control corrosion and neutralize any acidic left over from
Acid cleaning processes. It contains no chromate or
Heavy metals.
Application
Can be added directly into the raw water to give a 2% to 10% solution,
Which then may be used for “passivating”, “neutralization” & “protection”.
For offline storing purposes a 0.5% solution may be quite effective. The
Surface to be passivated, neutralized or get protection must receive a
Minimum of 15-30 minute contact time.
Dosage
Dosage is calculated depending on the circulating or storing volume and
The time of contact. A diluted solution of 0.5% up to 10% is recommended.
Use concentrated solution for less contact time & higher initial conditions,
Where as a 0.5% solution may be used for storing.
Handling & precaution
This product is quite alkaline and should be handled with care to prevent
Personal injury. Protective clothing and eye protection should be provided
And worn. In case of skin contact, immediately flush thoroughly with plenty
Of clean water. In case of eye contact, flush with copious of amounts of
Water for 15 minutes and obtain immediate medical attention.
Packaging
Available in pail of 20 lt.. Can also be custom packaged
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
LC 122 is an effective wide band micro-biocide designed
for use in algae and bacteria control. It does not cause
foaming and is not lost by evaporation from the system.
It is a concentrated blend of organo-sulfur compounds,
which should be added only after proper dilution by slug
feeding.
Application:
Use to control algae and bacteria in re-circulating commercial and industrial
water cooling towers. Prior to its use, systems be cleaned to remove algae
growth, microbiological slime and other deposits.
Dosage:
Initial slug additions of LC 122 per 1,000 gallons of water should be
employed every 1 - 5 days or as needed. The frequency of addition
depends upon the relative amount of bleed-off and the severity of the
microbiological problem. Slug additions should be made in the sump of the
cooling tower. During very hot weather, greater frequency or higher dosage
may be required to increase its effectiveness.
Handling & Precaution:
It is a very strong alkaline treatment and may cause eye damage and skin
irritation. Do not get in eyes, skin or on clothing. Wear goggles or face shield
and rubber gloves when handling. Avoid contamination of food. Harmful or
fatal if swallowed. In case of skin contact wash with plenty of soap and
water. Remove contaminated clothing and wash before reuse. If product
gets in the eyes, flush immediately with copious amount of clean cool water
for at least 15 minutes. If swallowed, call physician. Do not induce vomiting
or give anything by mouth to an unconscious person.
Packaging:
Available in pail of 20 lt.. Can also be custom packaged.
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
LC 123 is specially formulated for large installations high
hardness water. It is developed for effective, economical
cooling water treatment at hospitals, hotels, large apartment
houses, office buildings and other industrial and institutional
cooling installations with high hardness make-up water. It
contains no phosphates, chromate, zinc, or other chemicals
that cause pollution problem. Helps control mineral
deposits, sludge and surface pitting and does not stain
automobiles or buildings.
Application
Use a reliable automatic proportioner with timer for controlled dosage.
Follow instructions for calculated bleed of rate and recommended daily
maintenance treatment as suggested by the Field Chemist Personnel. The
dosage and treatment program depend on size of installation and water
hardness (ppm).
Dosage
Initial treatment : Add 1 gallon of LC 123 per 2,000 gallons of recirculating
water. Maintenance treatment as per size of installation &
hardness (consult our Technician)
Handling & Precaution
Wear protective clothing and eye protection should be provided and worn.
In case of skin contact, immediately flush thoroughly with plenty of clean
water. In case of eye contact, flush with copious of amounts of water for 15
minutes and obtain immediate medical attention. Refer to MSDS for more
specific directions.
Packaging
Available in pail of 20 lt.. Can also be custom packaged.
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
LC 124 is an effective chlorine based designed for use in
algae and bacteria control. It does not cause foaming. It
is a concentrated blend of organo-chloro compounds
which should be added only by slug feeding.
Application:
Use to control algae and bacteria in re-circulating commercial and industrial
water cooling towers. Prior to its use, it is advisable that systems be cleaned
to remove slime and other deposits.
Dosage:
An initial slug addition of 1 gallon of LC 124 per 2,000 gallons of water
should be employed every 1-4 days or as needed. The frequency of
addition depends upon the relative amount of bleed-off and the severity of
the microbiological problem. Slug additions should be made in the sump of
the cooling tower. During very hot weather, greater frequency or higher
dosage may be required to increase its effectiveness.
Handling & Precaution:
It is a very strong treatment and may cause eye damage, mucous attack
and skin irritation. Do not inhale, get in eyes, skin or on clothing. Wear
goggles or face shield and rubber gloves when handling. Avoid
contamination of food. Harmful or fatal if swallowed. In case of skin contact,
wash with plenty of soap and water. Remove contaminated clothing and
wash before reuse. If product gets in the eyes, flush immediately with
copious amount of clean cool water for at least 15 minutes. If swallowed,
call physician. Do not induce vomiting or give anything by mouth to an
unconscious person.
Packaging:
Available in pail of 20 lt.. Can also becustom packaged.
Oct-07-16
Supplier From Tangerang, Banten, Indonesia
 
KB 201 is a powerful porcelain cleaner for brightening
& cleaning porcelain surfaces. It contains complexing
agent, sequestering agent, scale remover, wetting
agent and specialized blooming remover. It is a
specialized product and requires careful application
methods. WRONG & UNWANTED APPLICATIONS
NOT PRESCRIBED, MAY CAUSE UNEXPECTED
RESULTS & DAMAGE. Must be diluted before use.
Never use on glazed surfaces.
Application:
Pour diluted KB 201 on the surface to be cleaned, allow it to react for 2 –
20 minutes, depending on the type of stain & dilution factor. After that,
brush with soft brush then rinse thoroughly with clean water. Make small
test spot to verify result before actual use.
Dosage:
Dilute with water depending on the cleaning work. Can be diluted up to
50 times or more.
Handling & Precaution:
Contains only organic acidic compounds. Do not ingest. Do not get in
eyes, on skin or clothing. Keep the container closed when not in use.
Avoid breathing the mists. Wear a mask when handling. Use sufficient
ventilation to prevent build-up or mists. KEEP AWAY FROM CHILDREN.
Packaging:
Available in pail of 20 lt.. Can also be custom packaged.
66 Water Treatment Chemicals Suppliers
Short on time? Let Water Treatment Chemicals sellers contact you.
See what buyers and suppliers are discussing in Water Treatment Chemicals import export community