55 kVA Generator Sets
Motor Brand : Ricardo
Alternator Brand : Gentech
Cylinder Numbers : 55 kVA ( 4 Cylinders )
Rpm : 1500
Working Systems : Automatic
The brand of Control Modules : Datakom
Fuel Systems : Diesel
Delivery Terms : FOB Istanbul or CIF
Warranty : International 1 year spare part warranty
Quality Standard Certificates : CE / ISO 9001 / OHSAS 18001 / ISO 14001 / Gost-R / TS
All products that we manufacture are in the A class quality
Gentech Alternators have been entirely manufacturing with Turkish property products in Gucbir factory in Turkey
Datakom Control Panels have been entirely manufacturing with Turkish property products in Turkey Datakom facilities.
We have productions of Automatic,Manuel,Portable Generators as optional
Please contact us for our competitive export prices
We can send the goods to all world countries as CIF delivery
•Diesel engine types suitable for heavy duty
•4 stroke engine,water cooled
•Mechanic/Electronic governor systems
•Direct injection fuel system
•Replacable cylinder jackets
•12/24 Volt DC
•Replacable oil filter,fuel filter and dry type air filter
•Cooling radiator and fan
•Flexible fuel hoses and oil outlet valve
•Industrial muffler and flexible expansion compensator
•Starter battery (lead acid) including wire and mount
•Jacket water heater (for automatic models)
ALTERNATOR FEATURES
•Gentech brand,made in Turkey
•Brushless,mono bearing,4 polar
•Isolation class H
•Protection class IP 21/22/23
•Self-alarm and regulated
•Electronic automatic voltage regulator
•2/3 stator windings to prevent harmonic failures
•Windings are imprengiated with tropic epoxy resin against oil and acid
CONTROL PANEL FEATURES
•The control panel of monitoring,operation and safety is mounted on generator chassis
•The features of automatic control panel :
•Components on the panel
•DKG 307 control module to monitor complete system
•Static battery charger
•Emergency stop button
a) The features of generator control module DKG 307/DKG 309
•Automatic generator protection and control functions
•Remote control function
•Analaog displays for temperature and oil pressure
•CosØ and KW displays for Generator
•Engine operation time-clock
•Maintenance time-clock
•165 programmable parameters
•Battery operated real-time clock
•Weekly operating timer
•Daily,weekly,monthly test
•Fault recorder (with date and time info)
•Statistical counters
•Monitoring and recording at pc via RS-232 serial data port
b) Displays on LCD monitor
•Generator Volt (F-N)
•Generator Ampere (L1,L2,L3)
•Generator Frequency (Hz)
•Generator CosØ
•Generator Active Power (KW)
•Oil Pressure (bar)
•Cooling Water Temperature (0C)
•Maintenance Timer
•Network Volt (F-F/F-N)
•Operating time display
•Battery Voltage
c) Alarms on LCD monitor
•Overload/Over voltage
•Over speed
•Low/High network voltage
•Low/High Generator Frequency
•Cooling Water Level
•Battery Alternator or Belt Breakage
•Engine Low Oil Pressure
•High Engine Temperature
•Low Battery Voltage
•Charge Failure
L:260 cm
W:95 cm
H:165 cm
Q:1400 kgs.
197 Diesel Generators Suppliers
Short on time? Let Diesel Generators sellers contact you.
•Diesel engine types suitable for heavy duty
•4 stroke engine,water cooled
•Mechanic/Electronic governor systems
•Direct injection fuel system
•Replacable cylinder jackets
•12/24 Volt DC
•Replacable oil filter,fuel filter and dry type air filter
•Cooling radiator and fan
•Flexible fuel hoses and oil outlet valve
•Industrial muffler and flexible expansion compensator
•Starter battery (lead acid) including wire and mount
•Jacket water heater (for automatic models)
ALTERNATOR FEATURES
•Gentech brand,made in Turkey
•Brushless,mono bearing,4 polar
•Isolation class H
•Protection class IP 21/22/23
•Self-alarm and regulated
•Electronic automatic voltage regulator
•2/3 stator windings to prevent harmonic failures
•Windings are imprengiated with tropic epoxy resin against oil and acid
CONTROL PANEL FEATURES
•The control panel of monitoring,operation and safety is mounted on generator chassis
•The features of automatic control panel :
•Components on the panel
•DKG 307 control module to monitor complete system
•Static battery charger
•Emergency stop button
a) The features of generator control module DKG 307/DKG 309
•Automatic generator protection and control functions
•Remote control function
•Analaog displays for temperature and oil pressure
•CosØ and KW displays for Generator
•Engine operation time-clock
•Maintenance time-clock
•165 programmable parameters
•Battery operated real-time clock
•Weekly operating timer
•Daily,weekly,monthly test
•Fault recorder (with date and time info)
•Statistical counters
•Monitoring and recording at pc via RS-232 serial data port
b) Displays on LCD monitor
•Generator Volt (F-N)
•Generator Ampere (L1,L2,L3)
•Generator Frequency (Hz)
•Generator CosØ
•Generator Active Power (KW)
•Oil Pressure (bar)
•Cooling Water Temperature (0C)
•Maintenance Timer
•Network Volt (F-F/F-N)
•Operating time display
•Battery Voltage
c) Alarms on LCD monitor
•Overload/Over voltage
•Over speed
•Low/High network voltage
•Low/High Generator Frequency
•Cooling Water Level
•Battery Alternator or Belt Breakage
•Engine Low Oil Pressure
•High Engine Temperature
•Low Battery Voltage
•Charge Failure
Standby 40 kVA Prime 36 kVA
Rpm. 1500
Engine Model : R4105D
Number of Cylinders: 4
Dimensions without Canopy ( WxHxL ) cm : 95 x 170 x 140
Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160
Weight without Canopy kg. : 650
Maximum Fuel Consumption at Full Power: 6,6 Lt./Sa
Fuel Tank Capacity: 130 Lt.
Intake System: Natural
Engine oil capacity Lt.. : 6
Engine water capacity Lt. : 12.
Standby 50 kVA Prime 45 kVA
Rpm. 1500
Engine Model : R4105D
Number of Cylinders: 4
Dimensions without Canopy ( WxHxL ) cm : 95 x 180 x 145
Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160
Weight without Canopy kg. : 900
Maximum Fuel Consumption at Full Power: 8,1 Lt./Sa
Fuel Tank Capacity: 140 Lt.
Intake System: Turbo Charge
Engine oil capacity Lt.. : 13
Engine water capacity Lt. : 16.
Standby 75 kVA Prime 68 kVA
Rpm. 1500
Engine Model : R4105ZD
Number of Cylinders: 4
Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145
Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160
Weight without Canopy kg. : 1200
Maximum Fuel Consumption at Full Power: 12,4 Lt./Sa
Fuel Tank Capacity: 150 Lt.
Intake System: Turbo Charge
Engine oil capacity Lt.. : 13
Engine water capacity Lt. : 16.
Standby 90 kVA Prime 81 kVA
Rpm. 1500
Engine Model : R4105IZLD
Number of Cylinders: 4
Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145
Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160
Weight without Canopy kg. : 1400
Maximum Fuel Consumption at Full Power: 15,6 Lt./Sa
Fuel Tank Capacity: 150 Lt.
Intake System: Turbo Charge, Intercooler, Aftercooler
Engine oil capacity Lt.. : 16
Engine water capacity Lt. : 25.
EAP 88
Engine: PERKINS
Engine Model : 1104A-44TG2
Stand By kVA: 88
Stand By kW : 70,4
Prime kVA: 80
Prime kW : 64
Rated Current : 115,2
Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1104A-44TG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 88 / 120
Prime Power Hp 80 / 110
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 18,5
Lt %75 LOAD 14,2
Lt %50 LOAD 9,8
Frequency Hz
Power kVA 93
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1350
Weight (Open) Kg 1160
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70
Engine: PERKINS
Engine Model : 1104A-44TG1
Stand By kVA: 70
Stand By kW : 56
Prime kVA: 64
Prime kW : 51
Rated Current : 92
Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1104A-44TG1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 65,6 / 88,5
Prime Power Hp 59,6 / 80,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 14,6
Lt %75 LOAD 11
Lt %50 LOAD 8
Frequency Hz
Power kVA 79
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1280
Weight (Open) Kg 1100
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 66
Engine: PERKINS
Engine Model : 1103A-33TG2
Stand By kVA: 66
Stand By kW : 52,8
Prime kVA: 60
Prime kW : 48
Rated Current : 86,4
Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1103A-33TG2
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 60,5 / 82
Prime Power Hp 55 / 74
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 10,2
Fuel Consumption (lt / h) Lt Full Load 14
Lt %75 LOAD 10,4
Lt %50 LOAD 7,2
Frequency Hz
Power kVA 66
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1200
Weight (Open) Kg 1030
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22
Engine: PERKINS
Engine Model : 404A-22G1
Stand By kVA: 22
Stand By kW : 17,6
Prime kVA: 20
Prime kW : 16
Rated Current : 28,8
Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERKINS
Engine Model 404A-22G1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 23.3:1
Bore 84
Strok 100
Displacement Lt 2,21
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 10,6
Standby Power kw / Hp 20,6 / 27,8
Prime Power Hp 18,7 / 25,2
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 14
Fuel Consumption (lt / h) Lt Full Load 5,3
Lt %75 LOAD 4
Lt %50 LOAD 2,9
Frequency Hz
Power kVA 22
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 720
Weight (Open) Kg 590
Width (Silent) Mm 950
Length (Silent) Mm 2000
Height (Silent) Mm 1200
Fuel Tank Capacity Lt 125
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 1000
Engine: CUMMINS
Engine Model : KTA38-G2A
Stand By kVA: 1000
Stand By kW : 800
Prime kVA: 909
Prime kW : 727
Rated Current : 1308
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2A
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 895 / 1199
Prime Power Hp 813 / 1089
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 202,3
Lt %75 LOAD 153,7
Lt %50 LOAD 103,1
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9350
Weight (Open) Kg 8200
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890
Engine: CUMMINS
Engine Model : KTA38-G2B
Stand By kVA: 890
Stand By kW : 712
Prime kVA: 809
Prime kW : 647
Rated Current : 1165
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2B
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 789 / 1057
Prime Power Hp 711 / 953
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 176,9
Lt %75 LOAD 133,3
Lt %50 LOAD 91,3
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9300
Weight (Open) Kg 8150
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Place of Origin - Turkey and Germany
Brand Name - LOTUS
Model Number - LOTUS-GEN LOTUS-GAS
Usage - SVC
Phase - Three Phase
Protection - IP20 / IP55 / IP65
Frequency - 50Hz/60Hz
Power factor - 0.8/0.9/1/Customized
Color - Black or RAL7035 or Customized
Rated power - 10KVA - 4000KVA
EAC 825
Engine: CUMM�°NS
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
197 Diesel Generators Suppliers