Please click here to check who's online and chat with them.

Door Release Manual Call Point

Supplier From China
Jul-28-18

Product introduce:1. When the accident happens, press the plastic elements to alarm or open the door. Plastic elements had printing a indication.2. There are four colors, red, yellow, white, green.* The red used for FIRE fighting.* The white and green can be used for the access control system, emergency safety door.* The yellow is generally a warning function and an emergency rescue for natural disasters.Specifications:Product nameManual Call Point,Emergency door releaseBrand nameYIXINModelYX-BP560STypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalColorRed/Green/Yellow/Blue/White optionalBreaked materialPlastic filmCoverWith water-proof cover optionalDimension87*87*52mmWarranty1 YearProduct Feature:1.The manual call point use plastic sheet which can reused.2.Adopt plastic film instead of glass to avoid cutting the hand when alarm.3.The shape is rugged and durable,the shell is made of fire retardant materials, and the product components are resistant to high temperature
and shock resistance.It is special design for fire alarm control panel and security alarm system.

Price and Minimum Quantity

Price: $10.00
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Door Release Manual Call Point

Jul-28-18
 
Introduction:The emergency door release manual call point is 3 poles with sounder and light. The manual call point are used to allow building occupants to signal that a emergency exists within the building.SpecificationsProduct NameEmergency Door Release Manual Call PointPower supplyDC 12-24VOperation currentDC 12V/18mA(Standby)/75mA(Operation DC 24V/11mA(Standby)/41mAOperation)BuzzerSet as silent,  interval wailing or  continuous wailingIndicatorDual-color (red and green).Red indicator to set blinking,off or on.OutputN.O.N.C.&COM.Output(Maximum load of 125V/3A)MaterialABS,PC(trasparent part)Starting parts typeReusableStarting modeManual pull down plateReset modeKey resetWeight208gDimensions90*93*45mmInstallationSurface mounted with screwFeatures1.Resetable design,obvious indicators around the edges of the unit.2.Press the pressing plate to enable the output function.3.Pressing plate with status (green and red) shown.4.Reversionary key with non-slip design.5.Input power range from DC12-24V to connect with all types of alarm system.6.Built-in buzzer status to set as silent,interval wailing or continuous wailing Volumeis adjustable.7.Easy to assemble,outer case without screws,3 set of output points to connect other equipment,embedded or surface installations to select.Note: only has output point function.
GOLD Member
Sep-07-21
Supplier From Hui Zhou, Guang Dong, China
Jul-28-18
 
Product Introduction:This product named Manual Call Point,Website:,also called emergency door release button or manual pull button.1.Fire--When there is a fire,pull button to issue a signal to a fire alarm control panel,the control panel will showing the serial number of the call point or the location
and send out alarm sound, once it received the signal.Access control--When there are chaos or emergency surround you,pull the call point to open the corresponding safety, door.2.Applicable type: safety, door, escape door, safety systemTechnical Parameters:Product nameManual Call PointBrandYIXINModelYX-BP562TypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalColorRed/Green/Yellow/Blue/White optionalCoverWith water-proof cover optionalDimension91*87*55mmWarranty1 YearProduct, Feature, :1.Key reset manual call point use plastic sheet which can reused and reset.2.It takes just a few seconds to reset the call point by Special key after pull.3.The manual call point can use its own, bottom case surface mounted or recessed mounted,easy to install.
Oct-20-16
 
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient
Way for building occupants to manually initiate a fire alarm condition.
Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the
Operating face to the quiescent position.
Pressure activated displacement element provides a safe user experience
Integral indicator to show polling and alarm activation
Resettable with simple key operation
Suitable for indoor use
Monitors for quiescent, alarm and fault conditions
Dip switch address setting
125 usable detector address settings per loop
Dec-26-17
 
2-wire DC24V Conventional Manual Call Point Broken Glass Button Push Button

The conventional manual call point designed for
conventional fire alarm system for reporting fire or
emergency condition by pull down the plate. The
manual call point can be reset by a special key
without breaking the glass.

Features

1. Compatible with all the conventional fire alarm control panel
2. Can be reset by key without use a new glass
3. 470 Ohm resistance
4. Easy surface mounting Base included
Specifications

Operating Voltage Range: 9 to 28VDC Volts
Alarm Resistance 470ohm/1W
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: Length 140mm, Width 105mm, Depth 45mm
Weight: Net Weight 220g
Oct-20-16
 
The 460 manual call points includes a pressure-activated displacement element to provide a safe and convenient
Way for building occupants to manually initiate a fire alarm condition.
Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the
Operating face to the quiescent position.
Pressure activated displacement element provides a safe user experience
Integral indicator to show polling and alarm activation
Resettable with simple key operation
Suitable for indoor use
Monitors for quiescent, alarm and fault conditions
Dec-26-17
 
2-wire DC powered Conventional Manual Call Point Push Button

The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.
Specifications:

Operating Voltage Range: 9ï½?32VDC Volts
Nominal Operating Resistance: 300Ω
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: W89mm ,H93mm, D26mm
Base Dimensions: W87mm ,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
GOLD Member
Feb-06-23
Supplier From Dhaka, Dhaka, Bangladesh
 
The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
GOLD Member
Feb-06-23
Supplier From Dhaka, Dhaka, Bangladesh
 
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.

Verification Status