Application:XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil.
Application:XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil.
PVC Insulated & Sheathed Power Cables
Standards: IEC60502, GB/T12706-2008
Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity.
Service Conditions:
1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2
2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
This cables are used as power distribution and transmission at rated voltage of 0.6/1kV.
Working temperature: max 70 degree centigrade
Short circuit: 5 seconds at max 160 degree centigrade
Models:
VV: Copper Core, PVC insulated and Sheathed Electric Cable
VLV: Aluminum Core, PVC insulated and Sheathed Electric Cable
VV22: Copper Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable
VLV22: Aluminum Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable
VV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable
VLV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable
VV42: Copper Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable
VLV42: Aluminum Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable
ZR-VV: Copper Core, PVC insulated and Sheathed, Flame retardant Electric Cable
ZR-VLV: Aluminum Core, PVC insulated and Sheathed, Flame retardant Electr ic Cable
Installation:
While installation, the temperature should not lower than 0 degrees Celsius, if the ambient temperature is lower than 0 degrees Celsius, the cable should be preheated.
The bending radius should not be smaller than 8 times of diameter of cable.
After installation, voltage withstand test for 15 minutes at 8.4kV direct current should be performed.
Application:XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil.
As one of the leading Suppliers, we keep our quality in synchronization with our reputation and offer the best PVC Power Cables to the buyers. Only strict and different quality tests, we undertake, ensure the utmost quality of our products.