Supplier : Electric cable, control cable, wire cable, rubber cable, solar cable, overhead cable, power cords, special cable, electric wire, mineral cable, aerial bundled cable
Model: QS-001
Conductor : Tinned fine copper strands, according to VDE0295/IEC60228, Class 5
Insulation : Polyolefin copolymer electron-beam cross-linked
Jacket : Polyolefin copolymer electron-beam cross-linked, UV and ozone resistant
Jacket color : All color
Rated voltage : U0/U=600/1000V AC; 1000/1800V DC
Test voltage : 6500V, 50Hz, 5 minutes
Max. conductor temperature : -40 ~ 120
Ambient temperature : -40 ~90
Max. Short circuit temperature : 280
Bending radius : Fixed installation: >4xO.D.; Occasionally moved: >5xO.D.
Fire performance : IEC60332-1
Smoke emission : IEC61034; EN50268-2
Low fire load : DIN51900
These cables are widely used in photovoltaic system power station, terminal block, connector, inverter, junction box and so on.
It is flexible, uvioresistant, Ozone resistant, hydrolysis resistant, able to be used in high temperature occasion.
It could work for over 25 years at 9
This cables are used as power distribution and transmission at rated voltage of 0.6/1kV.
Working temperature: max 70 degree centigrade
Short circuit: 5 seconds at max 160 degree centigrade
Models:
VV: Copper Core, PVC insulated and Sheathed Electric Cable
VLV: Aluminum Core, PVC insulated and Sheathed Electric Cable
VV22: Copper Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable
VLV22: Aluminum Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable
VV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable
VLV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable
VV42: Copper Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable
VLV42: Aluminum Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable
ZR-VV: Copper Core, PVC insulated and Sheathed, Flame retardant Electric Cable
ZR-VLV: Aluminum Core, PVC insulated and Sheathed, Flame retardant Electr ic Cable
Installation:
While installation, the temperature should not lower than 0 degrees Celsius, if the ambient temperature is lower than 0 degrees Celsius, the cable should be preheated.
The bending radius should not be smaller than 8 times of diameter of cable.
After installation, voltage withstand test for 15 minutes at 8.4kV direct current should be performed.
Its applicable to overhead line with AC rated voltage of 10/12kV.
Maximum long-term allowable working temperature of conductor is 90 degrees Celsius.
While the installation, the ambient temperature should not lower than minus 20 degrees Celsius.
When the core is in short circuit (max 5s), the temperature should not exceed 250 degrees Celsius.
Solar cables are widely used in photovo ltaic system power station, terminal block, connector, inverter, junction box and so on.
It is flexible, uvioresistant, Ozone resistant, hydrolysis resistant, able to be used in high temperature occasion.
It could work for over 25 years at 90â??.
The product is applicable to overhead power line with rated AC voltage of 10kV (12kV);
Maximum long-term allowable working temperature is 90 Degrees Celsius;
While installation,the ambient temperature should not be lower than minus 20 Degrees Celsius;
When the core is in short circuit ( max 5 s ) the temperature should not exceed 250 Degrees Celsius.
This cable will produce very little smoke and innocuous gas without halogen when burnt, it could definitely reduce the damage to the instrument, equipment and people. It was widely used in the crowded public place, such as high-rise building, hospital, library, gym, station, and mall.
The plastic insulated cables (rated voltage: 35kV) produced by Qinshan Company, completely comply with GB/12706:2002, GB5023:1997 and GB9330:88, DJ08-93:2002; meanwhile, our flame retardant, low smoke and zero halogen cables comply with GB/T17650-1~2:1998, GB/T17651-1~2:1998, burning in the environment of 800 degrees Celsius or lower, ensure the conductor working at least 180 minutes, itâ??s twice of of the regular fire resistant cables.
Models:
WDZN-YJE: Copper core, XLPE insulated,Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable
WDZN-YJE22: Copper core, XLPE insulated, Steel tape armoured, Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable
WDZN-YJE32: Copper core, XLPE insulated, Fine steel wire armoured,Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable
A. Single core - Nominal cross section area of conductor 2.5~630mm2
B. Cores: 2,3,4,5,3+1,3+2,4+1 - Nominal cross section area of conductor 4~300mm2
The wire is suitable for fixed installation of electrical equipment or lighting devices at AC rated voltage U0/U: 300/500V or lower.
Models:
BXF - Copper conductor rubber insulated/chloroprene rubber mixture sheathed power line
BLXF - Aluminum conductor rubber insulated/chloroprene rubber mixture sheathed power line
BX - Copper conductor rubber insulation cotton yarn or other similar fiber weaving power line
BLX - Aluminum conductor rubber insulation cotton yarn or other similar fiber weaving power line
BXR - Copper conductor rubber insulation cotton yarn or other similar fiber weaving flexible power line