Please click here to check who's online and chat with them.

Microprocessor Dissolved Oxygen Meter

Supplier From India
Apr-14-25

Highly Stable & Accurate
16X2 Line Alphanumeric LCD
1000 Samples Storage Facility
PC Interface Facility
Auto/Manual Calibration
D.O. & Temperature Measurements
Soft Touch Membrane Type Keys

Technical Specifications:-

Model
S- 955


Display
16X2 Line Alphanumeric LCD With Backlit


Range
DO: 0-20 ppm, Temp. 0-100C


Resolution
DO: 0.1 ppm, Temp.: 0.1C

Accuracy
DO: +0.2 ppm, Temp.: + 0.2C

Temp. Comp.
0-50C (Auto/Manual)

Key Board
8 Keys, Soft Touch Membrane Type

PC Interface
RS 232

Storage
Up to 1000 Samples

Power Supply
230V, + 10% AC, 50 Hz

Dimension
195X225X65 mm (LXBXH)

Weight
2 KG

 Accessories:

D.O. Probe
Temperature Probe.
D.O. Membranes
12V DC Adapter
Operation Manual
Dust Cover
RS 232
Software CD

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Microprocessor Dissolved Oxygen Meter

Apr-14-25
 
Ip67 Waterproof level, can float on the water surface.
Polarographic DO Electrode module can be replaced.
Auto OFF Function.
Double Line LCD Display.
Temperature Compensation.
Long Life Usage.

Applications- 
Laboratories, Environmental Monitoring, Food processing,
conventional Water or Wastewater, Chemical industry,
aquaculture, Aquariums, Swimming Pools.

TECHNICAL SPECIFICATIONS :

DO Range- 0.0-19.9mg/l (ppm)
DO Resolution : 0.1mg/l (ppm)
DO Accuracy-+0.5mg/l (ppm)
DO Calibration Points - 2 points
Temperature Compensation : 5-45 C (Auto)
Temperature Range : 0.0-99.9 C
Temperature Resolution : 0.1 C, Accuracy +0.5 C
Ambient Temperature : 10-50 C
Calibration Reminder-Yes
Display : Double Line LCD display
Auto OFF - After 10 minutes, if not in use
Battery- 4 x 1.5V coin cell batteries
Dimension (LxWxH) & Weight 170 x 37 x 37mm & 90g
Apr-15-25
 
Microprocessor Turbidity-Temp. Meter S-966

Highly Stable & Accurate.
16 Character X 2 Lines Alphanumeric LCD.
30 mm flat bottom Test Tube.
0 to 1000 NTU
Automatic Range Selection.
Higher durability and long life.
Tested on quality parameters.
1000 Samples Storage with Date &Time.
Measurement of Temp. and Turbidity.

Technical Specifications:-

Model
S- 966

Turbidity
Range
0-1000 NTU
Resolution
1.0 NTU in lowest Range
Range Selection
Automatic
Accuracy
+3%, FS+1 -digit

Detector
Photodiode

Sample System
30mm Clear Glass Test Tube

Light Source
3.6 V/ 100ma LED

Calibration
Manual

Temperature

Range
0C to +100C

Resolution
0.1c

Accuracy
+0.2%

Input Type
Pt 100

Calibration
Auto/Manual

Display
16 Character X 2 Lines Alphanumeric LCD

Display Format
Temp &Turbidity Simultaneously

Setting
By Soft Touch Keys

Storage
1000 Samples With Date & Time

PC Interface
RS-232

Real Time Display
24 Hour Mode With Date

Power Supply
230 V +-10% Ac 50 Hz Dimension 198x238x103mm

Weight
3 kg.
Accessories-

Test tube (Set of 5)
Operation Manual
Dust Cover
Apr-14-25
 
Polarographic Dissolved Oxygen Electrode easy to use.
Portable Dissolved Oxygen meter is equipped with a backight LCD display.
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations eliminate the measurement errors.
Automatic temperature compensation ensures accurate readings over the entire range.
Auto-read function senses and locks the measurement endpoint.
Auto-power OFF effectively conserves battery life.
Setup menu allows setting the number of calibration points, temperature unit, etc.
Reset function automatically resumes all settings back to the factory defaults.
Expanded memory stores or recalls up to 100 data sets.
USB communication interface for data transfer or connecting a power adapter to the meter.
Battery Life : Approximately 150 hours without backlight.
Automatic shutdown - After 15 minutes, If not in use
Carrying Case is Standard Supply

Dissolved Oxygen Range -  0.00 to 20.00 mg/L, (ppm)
Dissolved Oxygen Resolution : 0.01 mg/L, (ppm)
Dissolved Oxygen Accuracy-±0.5 mg/L, (ppm)
Saturation Range -  % 0.0 to 200.0%
Saturation Resolution : 0.1%
Saturation Accuracy -±2.0%
Calibration : 1 or 2 points
Temperature Compensation - 0 to 50C / 32 to 122F, automatic
Pressure Correction - 60.0 to 113.3 kPa / 450 to 850 mmHg, manual
Salinity Correction -  0.0 to 50.0 ppt, manual
Display -  LCD
Hold Function Selectable : - Manual or Automatic hold after measurement end point
Auto-Power OFF-  15 minutes, if not in use
Carrying Case- Available
Reset Function-  Yes
Date & Time -  Yes
Memory  : Upto 100 data readings
Connector- 6-pin mini-DIN
Communication : USB Interface
Power Supply : 3 1.5V AA batteries or 5V DC power adapter
Packing Dimension : (LxWxH)mm 350 100 300mm
Net / Gross Weight -  300g/ 1.5kg
Aug-13-19
Supplier From Shanghai, China
Oct-17-20
Supplier From Guntur, Andhra Pradesh, India
Jul-29-22
 
Agasthya 2013 Series Insitu Zirconia Oxygen Analyzer
BI 2100-HL (upto 900 deg C)

Technology Zirconia
Range 0100% O2 Programmable
Accuracy 0.5% of FS
Resolution 0.01%
Repeatability 0.5% of FS
Response Time T90 3 sec
Process Gas Temperature 900
Probe MOC Inconel
Diffusion Element Unbreakable Ceramic. Sintered Steel filter as optional
O2 Probe Length 250, 500, 750, 1000, 1500, 2000 mm
Flange ANSI Cl. 150 3RF. Other Flanges on request
Reference Air Clean & Dry Instrument quality air (2 LPM)
Area Classification Safe Area. (Explosion Proof on request.)

Display Keypad LCD Display
Power 24 VDC. 230 V AC optional on request
Output 4-20 mA Analog Output & 3 Nos. Relay Output
Digital Interface RS 485, Modbus protocol
Ambient Temperature
Mounting Wall. Rack optional on request.
Enclosure Rating IP65
Calibration Auto & Manual
Cable between Sensor & Electronic 4 core, 25 meter
May-09-20
Supplier From Kolkata, West Bengal, India
Jun-01-20
Supplier From Istanbul, Turkey
Oct-18-18
Supplier From Ambala, Haryana, India

Verification Status