Please click here to check who's online and chat with them.

Earth Ground Resistance Tester

Supplier From China
Dec-10-21

Product description

Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.


Technical index

1

Conditions of use

1 540

RH 80%

2

Anti-interference principle

Frequency conversion method

3

Electric source

AC 220V 10%

allowed generator

4

Measure output current

1A 5A Adjustable

5

Measure output voltage

0V 100V

6

Test power frequency


45, 50, 55, 60, 65HZ single frequency

45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency

7

Output rating

500W

8

Distinguishing rate

Grounding impedance 0.0001

Impedance angle 0.0001
9

Precision

Grounding impedance 1% reading 0.002

Impedance angle 1% reading 0.02
10

Resistance measurement range

0.001 5

11

Exterior dimensions

370 295 W 225 H

12

Memory size

100 groups support U disk data storage

13

Weight

Main engine 13 Kg, ground pile 7 Kg

Price and Minimum Quantity

Price: $770 - $15397
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Earth Ground Resistance Tester

Dec-09-21

Earth Ground Resistance Tester

$770 - $15.40K
MOQ: Not Specified
 
Product description

Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.


Technical index

1

Conditions of use

15 40

RH 80%

2

Anti-interference principle

Frequency conversion method

3

Electric source

AC 220V 10%

allowed generator

4

Measure output current

1A 5A Adjustable

5

Measure output voltage

V100V

6

Test power frequency


45, 50, 55, 60, 65HZ single frequency

45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency

7

Output rating

500W

8

Distinguishing rate

Grounding impedance 0.0001

Impedance angle 0.0001
9

Precision

Grounding impedance (1% reading +0.002)

Impedance angle (1% reading +0.02 )
10

Resistance measurement range

0.001 5
Jul-31-21

Earth Ground Resistance Tester

$770 - $15.40K
MOQ: Not Specified
 
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Dec-09-21

Ground Network Earth Resistance Tester

$770 - $15.40K
MOQ: Not Specified
 
Overview
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.

Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.

Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. measurable substation ground network (4) water and fire power plants microwave station (10) the lightning rod 10 multi-purpose machines.

Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Jul-15-21

Ground Network Earth Resistance Tester

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.

Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.

Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.

Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Jun-16-21

Ground Network Earth Resistance Tester

$770 - $15.40K
MOQ: Not Specified
 
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.

Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.

Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.

Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.

Product nickname Earth grid earth resistance tester earth grid earth resistance tester large earth grid earth resistance tester
Jun-23-21
 
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.

Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.

Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.

Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Jul-26-18
Supplier From Guang Dong, Guang Zhou, China
 
MEWOI3100B+ Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster. MEWOI3100B+ Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable; MEWOI3100B+ Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead.
Main Features 1Measuring Range0.01-200Ω2Stored Data99 sets3Clamp Size32mm4Power Consumption:Maximum 50mA
Model No.: MEWOI3100B+
Name: MEWOI3100B+-0.01Ω-200Ω Earth Resistance Clamp meter/tester
GOLD Member
Feb-15-14
Supplier From Gandhdidham, Gujarat, India
Supplier Of Quartz   |   Kaolin   |   Coke   |   Bentonite   |   Briquette   |   Iron Ore   |   Hematite Iron Ore   |   Heavy Melting Scrap (HMS)   |   Spices   |   Slag   |   Table Salt   |   Gypsum   |   Carbon   |   Salt   |   Clay   |   Common Salt   |   Coal   |   Sea Salt   |   Fly Ash   |   Zinc Ore   |   Silica Sand   |   Wood Powder & Sawdust   |   Ores & Minerals   |   Indonesian Coal
Jul-26-18
Supplier From Guang Dong, Guang Zhou, China
 
Main Features: 1,Equipotential bonding resistance Test,2,low value resistance test, 3,DC
resistance test
Model No:MEWOI4700
Name: MEWOI4700 Equipotential&DC low resistance testerMain
Function:Test of equipotential bonding resistance between functional metal components,
low value resistance test, DC resistance test, resistance test of connecting
conductor in ground network ground pole, contact resistance, riveting
resistance test, wire length test, etc.
Test Wires:2 red and 2 black wires, each 5m

Verification Status