Product description
Petroleum Kinematic Viscometer for conforms to GB/T 265-1988 "Measuring and calculating method for kinematic viscosity of petroleum products", which is applicable to test the kinematic viscosity of liquid petroleum products (Newtonian liquids). It is used to measure the time when a certain volume of liquid flowing through a calibrated glass capillary viscosimeter under the gravity at a constant temperature. The product of capillary viscosimeter constant and flow time is the kinematic viscosity of liquid at that temperature.
Technical index
Display: Color LCD display and touch screen
Temperature control range: Room temperature~150
Set temperature: 20 40 50 80 100 any value Higher than room temperature~150
Temperature control accuracy:±0.1
Number of test holes: 4
Timing range 0~999 second (According to the national standard, the flow time of each test sample must be higher than 200 seconds.)
Timing accuracy: 0.1 second
Timing number: 1~4 times (Optional)
Printing method: Panel mounted thermal printer
Power supply: AC220V�±5% 50Hz�±5%
Power: 1500W
Ambient temperature:5~35
Ambient humidity: 10%~80%
Product Introduction
After years of research and development our company has successfully developed battery charge and discharge tester which is highly intelligent and accurate with its proprietary technology. This tester can be used as a discharge load in the off-line state of the battery and realize constant discharge of the set value through continuous control of discharge current. During discharge when the terminal voltage of the battery or the voltage of the single battery falls to the set lower limit or the set discharge time reaches or the set discharge capacity the instrument will automatically stop discharging and record all valuable and continuous real-time data of the process.
Battery charge and discharge tester system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access.
Battery charge and discharge tester it has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Battery charge and discharge tester there is perfect protection function not only sound light warning but also a clear interface tips.
After years of research and development our company has successfully developed battery charge and discharge tester which is highly intelligent and accurate with its proprietary technology. This tester can be used as a discharge load in the off-line state of the battery and realize constant discharge of the set value through continuous control of discharge current. During discharge when the terminal voltage of the battery or the voltage of the single battery falls to the set lower limit or the set discharge time reaches or the set discharge capacity the instrument will automatically stop discharging and record all valuable and continuous real-time data of the process.
Battery charge and discharge tester system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access.
Battery charge and discharge tester it has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Battery charge and discharge tester there is perfect protection function not only sound light warning but also a clear interface tips.
Product description
The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple.
Main technical indicators and conditions of use
Measurement accuracy voltage, current 0.2 level
Power COS 0.1 0.5 grade, COS 0.1 1.0 grade
Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade
Voltage measurement range AC 3V 300V
Internal power output range voltage 0 250V, current 0 10A
Current measurement range AC 0.2A 20A
Working temperature 10 50
Working humidity 0 80
Working power supply AC220V 10 50Hz 1Hz
Dimensions 360mm 220mm 150mm
Weight of the instrument 20Kg
Transformer Short circuit Impedance Tester
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge meter can be in offline mode battery as discharge load Through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data.
Battery discharge meter system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access.
Battery discharge meter has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Product Introduction:
Lightning Protection Element Tester is suitable for testing the DC parameters of over-voltage protection components such as zinc oxide surge arresters (varistor) cermet two three-electrode discharge tubes and vacuum lightning arresters.
Product Parameters:
Varistor measurement
Technical index Measuring range Maximum error Test Conditions
Send InquiryCHAT NOW
Product Details
Product description
When the voltage of the battery pack or the voltage of a single battery is less than the set voltage lower limit, or the set discharge duration or set discharge capacity has been reached during discharge, the tester will automatically stop discharging and record the discharge Real-time data of all valuable and continuous processes in the process.
Battery charge and discharge tester Technical index
Applicable battery
Lead-acid battery
Model
DC220V
Discharge current
0-100A
recharging current
0-30A
Operating mode
Used independently or with a constant-current module
Control accuracy
Discharge current: â?¤�±1%; battery packâ??s terminal voltage: â?¤ �±0.1%; single battery voltage: â?¤�±0.05%
Communication with the host PC
RS485 interface
Data storage capacity
2Gbit FLASH
Product description:
Battery discharge meter should receive check discharge tests at regular intervals or whenever necessary as specified in the maintenance regulations of power systems so that the single batteries that have failed or tend to fail can be found and replaced early to make sure the corresponding battery packs can operate normally or their expected lives can be evaluated. We have successfully a line of extremely intelligent and accurate battery pack capacity testers (tester)
Battery discharge meter
Product description
The Single phase capacitance and inductance tester is specially developed for the problem of measuring the capacitance value of the capacitor on the substation.
Technical parameters
Instrument measurement range and accuracy
Capacitance measurement
Measurable capacitance range 0. 1 F 3,300
Measurable capacity range 5 20,000kvar
Measurement accuracy 1.0 readings 0.02 F
Resolution 0.001 F
Current measurement
Current measurement range 0 20A
Measurement accuracy 3.0 readings 0.05A
Resolution 0.01A
Inductance measurement
Inductance measurement range
small inductance mode 0.1mH 5mH
large inductance mode 5 mH 50H
Inductive reactance measurement range 50m 20K
Measurement accuracy 3.0 readings 0.05mH
Resolution 0.01mH
Resistance measurement
Resistance measurement range
small resistance mode 50m 1
Overview
High voltage insulation megohmmeter is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD.
Technical Parameters
Working Conditions environment temperature
relative humidity 85%RH
output voltage level 500V 1000V 2000V2500V
measurement range 019990M
Resolution 0.01M0.1M1.0M10.0M
relative error
Voltage/load 2500V/20M
Voltage drop about10%
short-circuit current 1.6mA
direct current 81.5V(AAR6)battery
alternating current 220V/50Hz
Power quiescent dissipation
WFLC-VI Portable Waveform Recorder is a portable device based on the structure of industrial portable computer. It takes high-performance DSP high-precision ADC chip and embedded operating system as hardware and software architecture and integrates data acquisition processing transmission storage analysis and other functions as one.
DSP acquisition chip for data acquisition and calculation so as to achieve full digital analog signal filtering flexible and diverse sampling frequency from 10K /s 20K /s 50k/s 100K /s can be selected by users can be used for transient electrical signal waveform recording and analysis.
With advanced industrial control kernel and embedded operating system users can easily carry out data storage backup analysis output and other operations
WFLC-VI portable waveform recorder is a collection of fault wave record generator characteristic test and other functions in the integration of intelligent instrument with its small size strong function scope of application is wide flexible configuration and many other advantages favored by the masses of users is a power utility workers standing it will be for the electric power industry production and technological progress to make due contributions.
The product names Waveform recorder waveform an
Overview
The gas relay calibrator is a tester device that specializes in verification of gas gas relays. The gas relay calibrator is a detection check device for the detection of the Vaste Relay Flow Period Value, Cable Point Value, and Sealing Pressure Value. Gas Relay Calibrator is suitable for more than 90 of Gas Relay checks in
Gas relay is also known as gas gas relay, is a protective unit in an oil immersion transformer, mounted in an oil pipe under transformer oil pillow. The gas relay detector is a dedicated gas relay pressure release valve calibrator device for the gas relay value, a capacity value, and sealing pressure value, and the gas relay tester uses a microcomputer control technology, and the gas relay tester is detected by detecting a high-precision pressure sensor. When the gas relay tester simulates the internal failure of the transformer, the gas method of the gas relay tester is calculated to calculate the flow rate value to achieve the detection of gas relatives, the Gas protection action value, the gas relay calibrator adopts the fine container combined with the US MCC's micro Press the precision sensor, detect the inside of the gas relay to exclude the liquid volume method to calculate the light gas capacity value
Technical parameter
Portable gas relay calibrator
Protection IP65
Execution standard Compliance with DL T540-1994 standards and IEC
power input 50HZ 220V
Flow speed detection heavy gas 0. 0.5m s 0.05m s resolution 0.01
0.52.5m s 0.1m s resolution 0.1
Maximum error 1
Volume detection light mill
0 300ml resolution 0.01ml
300ml 700ml resolution 0.1ml
Maximum error 1
test method Automatic measurement, semi automatic measurement, manual measurement of three measurement methods
Sealing test
0-150KPA resolution 0.1
0-300KPA resolution 1.0
Comprehensive error
Overview
Gas recovery inflatable device. The system includes vacuum and return system, purification system, compression system, condensing system, can be applied to various power supply companies, transmission and power generation engineering companies, power plants, high voltage transmission power stations, SF6 electrical switch manufacturing plants, etc. The department, as a Auxiliary equipment used by SF6 electrical products such as GCBP, GCBT, GIS, in installation, modulation, and overhaul. The above electrical products are used to recover, return, vacuum, gaseous, and liquid storage. The system can also be used as a device that evacuates and recover other expensive gases.
Technical parameter
Product recommendation model Size mm Weight kg Product Usage
12Q 4 40 1750 800 1550
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
(I) Technical index
1. Rated voltage:
2. Quality factor under full load in test of fire power generator: Q10 (relating to load)
3. Quality factor under full load in cable test: Q 30 (relating to load)
4. Quality factor under full load in test of main transformer: Q 30 (relating to load)
5. GIS, the quality factor under full load in switch test and other tests: Q 50 (relating to load)
6. Input power supply: single phase of 380V
7. Frequency adjustment range: 20Hz 300Hz
8. Accuracy of system measurement: 1.5
9. The unit possesses protective functions, such as over voltage, over current and zero start.
(II) Description for main configuration and technical data of equipment:
1. One set of variable-frequency power supply:
Rated power: 10kVA;
Input voltage: single phrase of 220V or three phase of 380V 10% and 45 65Hz
Output voltage: 0 400V adjustable
Output voltage frequency: 30 300Hz
0.1Hz adjustable stepping
Instability degree of frequency 0.02%
Output current: 0 25A
2. High-voltage resonane reactor (4sets in all): 27kV/1A
Rated working voltage: 27kV
Rated working current: 1A
Rated inductance value: 120H
Continuous working time: 60min
Temperature rise should be less than 60
Working frequency: 30- 300Hz
3. One set of exciting transformer:
Rated capacity: 10kVA
Input voltage: 400V
Output voltage: 1.2kV/3kV/5kV
Products Introduction
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05 F. 0.05 F capacitor in parallel to auxiliary output. Below is the capacitance of some instruments for your reference.
40KV vlf high voltage generator parameter :
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-40
40kV
(peak )
0.1Hz, µF
20A
Control
Body Boost 50
Used for cable and generator with corresponding voltage
0.05Hz, 2.2 F
0.02Hz, 5.5 F
0.01Hz, 11.0 F
Products Introduction
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose the suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05�µF. 0.05�µF capacitor in parallel to auxiliary output. Below is capacitance of some instrument for your reference.
40KV vlf high voltage generator parameter :
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-40
40kV
(peak )
0.1Hz,1.1µF
20A
Control 6
Body Boost 50
Used for cable and generator with corresponding voltage
0.05Hz, 2.2µF
0.02Hz, 5.5µF
0.01Hz, 11.0 µF
Theory of Ultra-Low Frequency Dielectric Strength Test
Ultra-low frequency dielectric strength test is an alternative method of power frequency withstand voltage test.As we know, due to the large capacitance of the insulating layer, a large-capacity test transformer or resonant transformer is required to perform power frequency withstand voltage tests on large generators and cables. Huge equipment is not only cumbersome, but also expensive and unsuitable for use.
Product description
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Technical index
1
Conditions of use
1 540
RH 80%
2
Anti-interference principle
Frequency conversion method
3
Electric source
AC 220V 10%
allowed generator
4
Measure output current
1A 5A Adjustable
5
Measure output voltage
0V 100V
6
Test power frequency
45, 50, 55, 60, 65HZ single frequency
45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency
7
Output rating
500W
8
Distinguishing rate
Grounding impedance 0.0001
Impedance angle 0.0001
9
Precision
Grounding impedance 1% reading 0.002
Impedance angle 1% reading 0.02
10
Resistance measurement range
0.001 5
11
Exterior dimensions
370 295 W 225 H
12
Memory size
100 groups support U disk data storage
13
Weight
Main engine 13 Kg, ground pile 7 Kg
This Tester is used to verify the electrical performance of Zinc Oxide Arrester. The instrument is suitable for various kinds of voltage levels zinc oxide arrester de-energized testing or energized testing thus define the risk and inner insulation moisture and valve aging defects.
1. 800 Ã?? 480 color LCD touch screen and high speed thermal printer.
2. Long distance wireless transmission. PT signal wireless transmission distance more than 400 m up to 2000 m;
3. Applicable for arrester de-energized test energized test and lab room test.
4. Three-phase current and three-phase voltage test simultaneously current and voltage sensor is isolated safe and reliable.
5. Two signal sampling methods support no voltage mode software calculation to get voltage reference
6. Built in high energy lithium battery And only weak current inside the instrument voltage is less than 12 volts.
7. Equipped with industrial grade operating system support direct shun-down mode
8. With 4G SD card can store massive testing data
9. With USB interface
10. Advanced data processing system support historical data management data analysis report automatic generation&printing
11. High sampling rate advanced digital signal processing technology high anti-interference performance and high precision.
12. With dust-proof waterproof anti-corrosion engineering seal box package small volume light weight and portable.
TKBLQ-II zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-II zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable.
1. This machine adopts large screen LCD display all English menu operation easy to use.
2. High precision sampling and processing circuit and advanced Fourier harmonic analysis technology ensure more reliable data.
3. The instrument adopts high-speed magnetic isolation digital sensor to directly collect the input voltage and current signals which ensures the reliability and safety of the data.
4. Support wireless synchronous voltage sampling mode (type II).
5. The instrument can use electric field induction instead of PT secondary wiring (type I).
6. It has the functions of resistive current fundamental peak output and side phase correction.
7. The instrument is equipped with rechargeable battery calendar clock and micro printer which can store 120 sets of measurement data.
Application:
TKBLQ-I zinc oxide arrester tester is a special instrument used to test the electrical performance of arresters. The instrument is suitable for live or power failure detection of arresters of various voltage levels, so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-I zinc oxide arrester test instrument is easy to operate and easy to use. The whole measuring process is controlled by microcomputer. It can measure the total current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large screen.
Features:
1. 5.7 "320 Ã?? 240 LCD, high-speed thermal printer; graphic display, intuitive interface, easy to operate and use.
2. It is applicable to live arrester, power failure or laboratory.
3. The current and voltage sensors are completely isolated, safe and reliable. A, B, C three-phase arrester can be stored as a group of test data.
4. The instrument can test continuously, display voltage current curve, and print data and curve quickly.
5. The internal configuration memory can store 200 groups of test data when power down.
6. With RS232 communication interface, the test data can be exported through the upper computer.
7. High speed sampling frequency, advanced digital signal processing technology, strong anti-interference performance, high accuracy of measurement results.
8. It adopts dustproof, waterproof and anticorrosive engineering plastic sealing box, which is small in volume, light in weight and easy to carry.
This instrument is carefully designed and developed by the relevant technical personnel of our company according to the needs of power users. The product is beautiful in appearance and easy to carry and use. It replaces the traditional bulky test instruments and test methods and is very popular among professionals.
1. Small size and light weight.
2. The measurement process is safe and fast and the measurement result is accurate.
Product Introduction
This instrument is used for discharge action logger inspection and verification of discharge counter in valve-type arrester including silicon carbide common valve type (FZ and FS), silicon carbide magnetic blow valve-type (FCZ and FCD) and zinc oxide arrester.
Product nickname Arrester discharge counter tester discharge counter tester discharge counter calibrator lightning counter counter lightning counter calibrator
Product description
The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests.
Zinc oxide arrester tester Technical Indexes
Range of reference voltage input peak 10V-200V
Measurement range of full leakage current peak 100uA 10mA
Measurement range of resistive current peak 100uA 10mA
Measurement range of capacitive current peak 100uA 10mA
Measurement range of angle 0-90
Power consumption 4W
System measurement accuracy reading 5 5 words not more than 2m for harmonic current
AC power supply AC 220V 10 50Hz 1
Precautions
When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit.
Be careful not to wrongly connect the current and voltage sampling lines in the connecting process.
In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.
Summary
The Arrester is suitable for testing the internal defects of 10KV and below 10KV MOA (metal Oxide Arrester).Before the annual season of thunderstormsit 's necessary to test metal Oxide using 1mA DC voltage and 0.75U1mA leakage current at Power plants/substations.The equipment was developped according to the requirement of site it 's integrated with DC HV supplymeasurement and control system. it has the characters of small size and light weight.
Feature
1.Supply power: AC220V or Charging battery.
2.LCD display test datas.
3.Convenient to carry.
Lightning Protection Element Tester is suitable for testing the DC parameters of over-voltage protection components such as zinc oxide surge arresters (varistor) cermet two three-electrode discharge tubes and vacuum lightning arresters.
Product nicknameï¼?Lightning Protection Element Tester Lightning Protection Component Tester Lightning Protection Element Tester Lightning Protection Element Tester
1 Lightning Protection Element Tester is suitable for the measurement of DC parameters of zinc oxide surge arresters (varistor) cermet two three-electrode discharge tube vacuum lightning protection tube and other overvoltage protection components. It can also be used for voltage regulation constant current power supply and used in other aspects.
2 with high voltage short circuit protection over current protection high pressure preset range adjustment and other functions high pressure self-release time is less than 0.5 seconds.
3 with self-test function.
4. The measurement data is displayed by three-and-a-half LCD digits with high accuracy and good reliability.
5. When measuring the range can be preset and an audible indication is given to the over-range test during the measurement process which is suitable for device grouping and inspection.
6 select continuous measurement you can carry out uninterrupted testing of batch samples.
7 the Lightning Protection Element Testerpanel is simple and easy to operate.
8 light weight easy to carry.
Overview
zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable.
Parameter:
1. Full current measurement range: 0-10mA effective value 50Hz/60Hz accuracy: (reading 5% + 5a)
2. Measurement accuracy of resistive current fundamental wave (secondary method without Interphase Interference): (reading 5% + 5a)
3. Current harmonic accuracy: (reading 10% + 10a)
4. Reference voltage input range: 25V-250V RMS total harmonic content 30% 50Hz/60Hz
5. Reference voltage measurement accuracy: (reading 5% + 0.5V)
6. Voltage harmonic measurement accuracy: (reading 10%)
7. Angle between fundamental current and fundamental voltage: 0-360
8. Working time of battery: 6 hours of main engine charging power supply: 220 V 10% 50Hz/60Hz charging time: 5 hours
9. Host volume: 325 280 140
10. Host weight: 3.5kg (without cable)
Product description
Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Electrical parameters
Electrical parameters
Accuracy class
0.05%, 0.1%
Power supply
Single phase AC 85-265V, 50/60 Hz
AC Voltage output
Range
57.7V / 100 V / 220V / 380V, Switch automatically (max 500V)
Adjustment resolution
0.01%, 0.1%, 1%, 10%,
AC Voltage output
Range 57.7V / 100 V / 220V / 380V, Switch automatically (max
Adjustment resolution 0.01%, 0.1%, 1%, 10%,
Accuracy 0.05% RG
Stability Better than 0.01% RG/1min
Distortion degree Better than 0.1% (not capacitive load)
Load capacity 40VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1ms
Temperature drift 8 PPM C
Long-term stability 60 PPM/year
AC Current output
Range
Adjustment resolution
Accuracy Stability
Distortion degree
Load capacity
Full load regulation rate
Full load regulation time
Temperature drift
Long-term stability
0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A,
Switch automatically 0.01%, 0.1%, 1%, 10%,
0.05% RG
Better than 0.01% RG/1min
Better than 0.1% (not capacitive load)
40VA
Less than 0.01% RG Less than 1mS
8 PPM C
60 PPM/year
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nicknameï¼?High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A.
1. The instrument can be used separately or linked to PC.
2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system.
3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability.
4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity.
5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure.
6. Two options: ampere-second characteristic test or through current characteristic test.
7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation.
8. Protection functions for overheat over-current and over voltage.
9. Anti-interference capacity and good EMC(electromagnetic compatibility).
Product Introduction
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A.
1. The instrument can be used separately or linked to PC.
2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system.
3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability.
4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity.
5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure.
6. Two options: ampere-second characteristic test or through current characteristic test.
7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation.
8. Protection functions for overheat over-current and over voltage.
9. Anti-interference capacity and good EMC(electromagnetic compatibility).
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nicknameï¼?High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product description:
Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices.
Major Technical Index
1. Environmental conditions
Temperature 5 40 Humidity:
Dielectric strength tester forTransformer Oil BDV Tester Three Cups insulation oil is my company all the scientific and technical personnel according to national standard GB507-86 line and the DL - 474-4-92 the relevant provisions of the DL/T596-1996 play their own advantages after a lot of field test and long-term unremitting efforts carefully research and development of high accuracy fully digital industrial equipment.Dielectric strength tester for insulation oil as a simple modelling is beautiful and easy.Due to the use of automatic digital microcomputer control so high measurement accuracy strong anti-interference ability safe and reliable.
Technical parameters
Booster capacity 1.5kVA
Booster speed 2.0kV /s 2.5kv /s 3.0kV /s 3.5kV /s
error: 0.2 kV/s
The output voltage 0 80kV (optional)
Voltage accuracy (2% reading +2 words)
Power distortion rate 1
Electrode gap standard 2.5 mm
Number of test 6 times (1-6 times optional)
Let stand time 5 min (1-9min optional)
Dimensions 670mm 420mm 410mm
Weight 38kg
Product description AC DC high voltage dividerFRC series AC DC high voltage divider also known as FRC Divider, it is a kind of resistance-capacitance equivalent potential screen voltage division type high voltage measurement device, is mainly used for the measurement of pulsed high voltage, lightning high voltage and power frequency high voltage. It is the first choice for the replacement of high voltage electrostatic voltmeter.
Technical index
Item
FRC-50
Voltage grade(kV)
AC: 50
DC: 50
DC frequency(Hz)
Overview
Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 ~ 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value " 12 road simulation small signal output, provides testing of protection devices input for small signals;
Technical parameter:
Fiber Ethernet port
4/6/8 pairs 100 Mbits / S, ST, Mode, 1310nm;
IEC61850-9-1 / 2 / Le, Goose, IEEE-1588;
Send dispersion:
Overview
The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.
Technical parameter
Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 ~ 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature: 0 360 Move 30 per step
Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer.
Technical parameter :
AC current output
Phase current output (effective value) 040A
Three merge current output (effective value) 0120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 900VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
AC voltage output
Output accuracy Level 0.2
Phase voltage output valid value 0120V
Line voltage output valid value 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
volume and weight Dimensions 365*300*165MM
Stand-alone weight 15.5KG
Overview
The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact.
Technical parameter:
AC current output
Output accuracy Level 0.5
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 1000VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (foundation) 20 1000Hz
Harmonic number 1 20 times
DC current output
Output accuracy Level 0.5
Current output 0 10A / each phase, 0 20A / two superimposed
Maximum output load voltage 20V
AC voltage output
Output accuracy Level 0.5
Phase voltage output (effective value) 0120V
Line voltage output (effective value) 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control
1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter
2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs
3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability
4. With RS232 and USB(optional) communication interface for PC connection
5. With aluminum alloy carrying box which look nice and with little weight
1. Design with touch panel and mask button massive information to see and simple to use
2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference
3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection
4. Three phase rated current rated voltage can be preset by users
5. Multiple choose of voltage current phase testing point
6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters
7. Large memory for data storage and searching data is very convenient
8. With R232 communication interface for PC control and software upgrade
Product Introduction:
AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Overview
The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are also available for sports, and measure the speed of the A point to the B point.
Technical parameter
Measuring range 0.0001 999.9999 seconds
Timing accuracy 0. 01 2 words
power supply AC 220V 10 50Hz
power 5W
input signal Mechanical air contact or electrical signal 5 20V
Reset method Manual or software clearing
Relative humidity 80 RH
Dimensions 195 175 80
weight 1.5 kg
Intelligent digital millisecond 1Intelligent digital millisecond
Product Introduction
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Technical Parameters
Measuring range Dew point value 80 20
Moisture content 0 19999uLL
Accuracy of measurement 0.5 60 20
1.0 80 60
The resolution of the Dew point value 0.1
Moisture content 1uLL
Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20
63 needs 10s 90 needs 240s 20 60
Sampling flow 0.6L min 20
Pressure range 01.0Mpa
The use of temperature 20 60
Environmental humidity 0 100 RH
Storage temperature 20 80
Charging time 4 hours
The whole machine size 250 150 300mm3
The weight of The machine 3.5kg
Overview
In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China.
Specification
Technical Parameters
Power supply voltage AC 220V22V
Power frequency 50Hz 2.5Hz
Work rate 200W
output voltage 0-80kV
Booster capacity 1.5kVA
Booster speed 2.0 2.5 3.0 3.5kV s adjustable
Total voltage distortion 3
Installation dimensions 470 390 420mm3
Weight 40kg
Conditions of Use
Environment temperature 40
Relative humidity 80
Capacity of the oil cup 200ml
Distance between the electrodes 2.5mm
Product description
Anti Emulsification performance automatic tester meets the requirement of GBT 7305-87 and GBT 7605-87, which adopts 32-bit high-performance microprocessor, high definition color touch screen and digital PID control algorithm to achieve high accuracy of temperature control, good repeatability, automatic lifting of stirrer, simultaneous test of four samples, smart storage and convenient check of test result.
Technical index
Temperature measurement Platinum resistance
Water bath temperature 54 Room temperature 100 can be set arbitrarily
Control accuracy 0.1
Stirring speed 1500 15 rmin
Number of cylinders 4
Self-check function Stirring device lifting and rotating
Display High definition color touch screen
Power supply AC 220V 22V
Power 1800VA
Frequency 50Hz 2.5Hz
Ambient temperature 10 35
Ambient humidity 85
Weight about 24kg
Profile size 358mm 302mm 858mm
Anti-emulsification performance automatic tester
Overview
High pressure wireless phase detector is a dedicated test high-voltage nuclear phase tester based on national power industry standard norms and market demand, and high-voltage nuclear photographic applies to detecting the two-sided circuit breaker of the ring or dual power supply power network closed loop circuit breaker. Whether it is produced in the same phase.
Before the closed loop two power supply, you must perform a nuclear phase, otherwise a short circuit can occur, suitable for the 6KV 220KV transmission line with the electrical core, the sight can reach 200 meters, and the wall can be used, and it has a test function.
Wireless high pressure cores use wireless transmission technology, safe and reliable operation, easy to use, in line with national electric power safety equipment quality supervision and testing standards. Compared with the cable core, it is the main advantage that the lead wire connected to both grids power supply is removed, and the safety is used to improve the security in a manner that is not subject to any terrain and facility architecture.
Technical parameter
Phase difference
Error 5
Frequency accuracy 0.1Hz
The voltage grade measured by this product is 6kv 220kv
Transmission distance of the transmitter and receiving host
Overview
Generator Rotor AC Impedance Testing Instrument is a special instrument for determining whether the turn-to-turn short circuit exists in the generator rotor winding, and can manually and automatically unidirectionally or bidirectionally measure many parameters of the generator rotor such as voltage, current, impedance, power and rotating speed.Generator Rotor AC Impedance Testing Instrument is the latest enhanced AC impedance tester launched by our Company. The instrument adopts the state of the art high speed microprocessor technology with more powerful functions, preferable performances and more convenient use. The Tester has a series of characteristics such as high reliability, easy operation, high test precision, being compact and lightweight and etc., and currently is in the domestic leading level.
Major Technical Indicators
Temperature 5 C 40 C
Relative Humidity 0 1 FS2d
Cos 0.1 0.5 FS2d
1kW 72KW 0.1 Cos 0 1 FS2d
Cos0.1 0.5 FS2d
Frequency 40-75HZ 0.2
Volume 415 225 200mm
Product description
3 phase capacitance and inductance tester is developed for the problems of capacitance value, and it solves the following problems
Field measurement capacitor needs dismantling cables, not only the big workload but also easy to damage the capacitor.
Low capacitance meter output voltage causes the fault detection rate is low.
The instrument has characteristics of small measured workload, fast and simple, stable performance, high measurement accuracy, high fault detection, etc.
Reactor inductance measurement.
Technical parameters
Working power supply
Rated voltage power frequency of 220 V10
The rated frequency 50Hz
The rated output 2V 20V 500VA
Equipment normal working conditions
Environmental temperature 10 50
Relative humidity 90
Display and print mode LCD display with Chinese characters
Panel high speed printer
Shape weight 370 260 220 mm 15 kg
5. Work principle as shown in figure 1
3 phase capacitance and inductance tester
Feature
The inductance capacitance tester adopts the bridge circuit structure, the standard capacitor and tested capacitor as two arms of the bridge circuit. When conducting the capacitor capacitance value measurement, test voltage applies on the standard capacitor and tested capacitor at the same time. Processor obtains capacitance value of tested capacitor by sensors with acquisition the current signals through the two capacitors after processing.
Due to adopting the standard capacitor, tested capacitor synchronous sampling technology, it may not affected by the power supply voltage fluctuation; Combined with the measurement process is fully automatic, which avoids the error due to manual operation, so it has the characteristics of good stability, good repeatability, accurate and reliable, the machine has tested object automatic identification and short circuit protection function.
Overview
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
Main Technical Parameters:
Booster output current & voltage
1A/2500V
2A/1500V
5A/600V
10A/220V
20A/30V
Current generator output current
600A
Output power
3000VA
Voltage and current measurement accuracy
0.2%
CT ratio tests
Range
1~40000
Voltage method / current method
Accuracy
0.2%
PT ratio tests
Range
1~40000
Accuracy
0.2%
Phase measurement
Accuracy
5min
Resolving power
0.5min
Secondary winding resistance tests
Range
Accuracy
0.52m
AC load tests
Range
0~1000VA
Accuracy
0.5% 0.05VA
Power supply
AC220V 10 50Hz
work environment
Size & Weight
Size: 425 mm 290 mm 310mm
Weight: 30kg
Product Introduction
This Transformer control boxof console is suitable for adjustable voltage control of 0.5-10kVA test transformer.
Technical Indicators
Maximum capacity
20kVA
Input voltage
220kV
Output voltage
0-250V
Maximum output current
0-90A
Mains phase number
single-phase
Power frequency
50HZ
Instructions precision
1.5 Class
Using Methods and Attention Matters
1.Check the test transformer measuring winding rated output voltage, and make it match the operation box correctly.
2. Connect the line between test transformer and operation box according to the wiring diagram.
3. Switch on the power supply, then close the knife switch, and the power indicator light, finally set the work time of relay.
4. Make the pressure regulator display zero, press the start button, the clockwise rotation of the hand wheel, until it reaches the required value.
5. Start the timing switch, timing begins, the electric bell will alarm automatically when it reaches the setting time(artificially controlled time if there is on alarming function), then break off the timing switch.
Q&A:
What is the difference between a control box and a box-type transformer
The control box has only control functions. It is a control unit. Its main function is to issue instructions to control the rapid breaking of the circuit breaker in the box substation; it is a component in the box substation.
The box-type transformer generally refers to the box-type substation, which integrates the functions of power transformation, power distribution, control, and protection.
Product description
The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device.
Technical index
Temperature
Humidit
Capacity: 20kVA
Specification
Weight: 75Kg
Allow long-term work on the rated current
Allowable overload 1.5 times,30 minutes of continuous work.
Feature
This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ.
Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline.
The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing.
The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Product description
Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight.
Technical Parameters
Working Condition:
(1) Temperature: 5
(2) Relative humidity:
FRC series AC DC high voltage divider also known as FRC Divider, it is a kind of resistance-capacitance equivalent potential screen voltage division type high voltage measurement device, is mainly used for the measurement of pulsed high voltage, lightning high voltage and power frequency high voltage. It is the first choice for the replacement of high voltage electrostatic voltmeter.
CT PT load box Please use an appropriate power cord for this product. Only the power cord dedicated to the machine or a suitable gauge can be used.
Connect and disconnect properly. Please do not connect or disconnect the test lead if it is connected to the charging terminal.
Ground the machine. The grounding pole of the machine enclosure must be grounded, unless the product is grounded through the power ground wire. To avoid electric shock, the grounding conductor must be connected to the ground. Before connecting the input or output terminals, make sure that the machine is properly grounded.
The arrester monitor has popularized my country s power plant power plants, providing important data for the reliable operation of the lightning arrester. Due to the difference in sealing performance, the monitor may enter moisture and moisture during operation, causing internal device rust, or other reasons, causing the monitor counter, and the leakage current indicates inaccurate.
At present, there are many varieties of monitors in the market, and the quality is also mixed, and most manufacturers do not provide monitoring equipment, and the simple detection methods provided by the procedures are very difficult, and the use of operation is not convenient. So how to determine the quality of the monitor has become a problem that the staff is very headache. In response to the above status, our company has developed a multi-functional high-precision test instrument that combines multiple functions such as monitor current verification, monitor motion test and current measurement, based on years of live experience, and current measurement. The instrument is an integrated structure, built-in large-capacity rechargeable battery, easy to carry, easy to carry.
Overview
The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.
Technical parameter
Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature
1. 5 LED digitally display output by actual value or by percentage
2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional)
3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V
4. Three AC frequency for option: 50Hz 60 Hz 400 Hz
5. Auto protection or manual resetting function for over load
6. Over load rang is 10% for each level of voltage current
7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
Product description
Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.
A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves).
The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment.
Technical Parameters
Input voltage AC220V 50 Hz
Output voltage 0~30kV
Capacity 3kVA
Test number 3 pairs each time
Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
1. Design with touch panel and mask button massive information to see and simple to use
2. built-in standard energy meter for digital closed loop feedback U I F W VAR VA PF all for reference
3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection
4. Three phase rated current rated voltage can be preset by users
5. Multiple choose of voltage current phase testing point
6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters
7. Large memory for data storage and searching data is very convenient
8. With R232 communication interface for PC control and software upgrade
Product description
The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage
Oil Immersed Testing Transformer 1
Technical index
Model
Capacity
KVA
High Frequency Voltage Output Voltage
KV
High Frequency Voltage Output Current mA)
Low Frequency Voltage input
Change
Tempera- ture() raised/
30 minute
V
A
YD G -1.5
1.5
50
30
200
7.5
500
10
YD G 3
3
50
60
200
15
500
10
YD G-5
5
50
100
200
25
500
10
YD G10
10
50
200
220/380
50/26
500
10
YD G20
20
50
400
380
53
500
10
30
50
600
380
79
500
10
40
50
800
380
105
500
10
50
50
1000
380
132
500
10
100
100
100
500
263
1000
10
150
100
1500
500
300
1000
10
200
100
2000
500
400
1000
10
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables.
1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use.
2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
Product description
120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90)
Technique Index
1. power: AC220V+10%, 50Hz+1%
2. Output voltage indicator accuracy:
Product Introduction
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. For circuit breakers with closing resistors the closing resistor and switching waveform can be accurately measured. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-pressure Breaker Analyzer Breaker Analyzer circuit breaker tester switch mechanical characteristic tester switch parameter tester
product brief introduction Product Introduction
TC power frequency voltage tester adopts integrated design, small size, light weight, more convenient for transportation and portable operation. The over-current protection of voltage tester is set by current relay, The high-voltage output, direct reading instrument and operation are integrated with the voltage stand. Therefore, the operation is simple, practical and reliable.
product brief introduction Product Introduction
Alternating and direct current amphibious light AC DC Hipot Test Set. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Product Parameters
technical parameters
environment temperature 0ï½?40â??
altitude < 100m
relative humidity < 85%
Main product specifications
type specification capacity power source output operating mode Refer to the weight
anthroposcopy (V) (A) (V) (A)
XC-2 2 1 220 50 0-220 10 manual operation 14
XC-3 3 1 220 50 0-220 15 manual operation 16
XC-5 5 1 220 50 0-220 20 manual operation 18
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation
1) AC/DC analog value input measurement
2) state variables input measurement
3) remote control execution testing
4) remote regulation function testing
5) digital value input testing
6) impulse input testing
2. AC Power source
It can output AC voltage AC current
accuracy 0.05 class
can provide standards of AC/DC voltage/current power phase power factor frequency energy.
Output method and output electric quantity can be set arbitrarily
3. Data management
It can save search browse print or delete RTU testing data.
Calibrated parameters can be saved permanently
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control
1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter
2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs
3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability
4. With RS232 and USB(optional) communication interface for PC connection
5. With aluminum alloy carrying box which look nice and with little weight
Product Description
ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.
Product Characteristics
1ã??Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1µA, shock resistance current 0.1µA.
3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .
4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.
5 75% MOA voltage switch button, simple and convenient testing arrester.
6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
product brief introduction Product Introduction
series is the equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through which completely overcome the problems of long blow water time bottom water hard to dry easy to cause arcing within the coil. The device is light simple wiring and easy to read. Polarization compensation voltage is output directly by the case.
product features Product Characteristics
1. Electronic control and tune easy to operate.
2. The date of voltage and current are recorded in the panel reading without conversion.
3. One minute timing and tip function.
4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator.
5. Portable design suitable for on-site testing.
6. Four parts separated: control unit Intermediate Frequency Transformer doubler and accessories all packed with special shockproof aluminum alloy cabinet easy to move.
Product description
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor
Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard
Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates
Impulse voltage generator (2)
Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);
(2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3%
(3)Standard operating impulse voltage wave 250 20% s
2500 60% s,
Products Introduction
Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
Technical Parameter
Product description
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude 1000m
Ambient temperature 5 40 Relative humidity 90 20 Use of the environment indoor
Non conductive dust Grounding resistance 0.5 No fire or explosion hazard
Earthquake resistance 8 magnitude There is no gas that corrodes metal and insulates
Impulse voltage generator 2
Supply voltage waveform is the actual sine wave, waveform distortion rate 85 more than 90 when no load 300PF
2 Truncated wave cut-off time 2-6 10 s, zerocrossing coefficient 0.3
Product description
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: 5 40 Relative humidity: 90 20 Use of the environment: indoor
Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard
Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates
Impulse voltage generator (2)
Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);
(2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3%
(3)Standard operating impulse voltage wave 250 20% s / 2500 60% s,
The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
1 Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1 A, shock resistance current 0.1 A.
3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .
4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.
5 75% MOA voltage switch button, simple and convenient testing arrester.
6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
Product Introduction
Insulation resistance tester dedicated to the measurement of water-cooled generator test but also can be used for laboratory or field testing insulation testing to do. Output current greater than 25mA. The maximum output voltage of 2500V. Includes high-precision micro-current measurement system digital boost system. Just use a high-voltage lines and a signal line connecting the test product can be measured. Automatic measurement the results from the large screen liquid crystal display and store the results.
Product Characteristics
First the main features
1. 32-bit micro-controller Chinese user interface easy to operate.
2. Automatically calculates the absorption ratio and the polarization index and automatically save 15 seconds 1 minute 2 minutes 10 minutes to facilitate analysis of data per minute.
3. Output current (2500V the output is greater than 25mA) short-circuit currents greater than 40mA.
4. A fully enclosed high-voltage generator module technology the protection of the internal resistance safe and reliable.
Anti-interference ability to meet the EHV substation on-site operation.
5. Automatic discharge test is completed and real-time monitoring the discharge process.
Product Description
450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test
Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below.
Product Characteristics
Rated parameter value
Rated nominal voltage ±450kV
Rated voltage ±150kV
Rated energy 20kJ
Total impulse capacitance 0.20F
The total series 3 series
Rated power capacity
The following waveforms can be generated when the load capacitance is 300~5000PF
2±30%/50 ±20%s Lightning impulse voltage full waveï¼?The efficiency of voltage 92%(no-load )
standard impulse voltage cut wave 2~6 The efficiency of voltage 92% (no-load)
The impulsevoltage waveform parameters all meet the requirements of IEC and GB311-97 national standards
Class voltage within 10% ~ 100% rated voltage range positive and negative synchronous range is not less than 20%.
Ignition range 10%ï½?100%
Synchronous discharge rate out of control 2%
Minimum output voltage 10un
Charging voltage instability ±1.0%
Service duration: > over 70% UN rated voltage can operate continuously every 90 seconds. Under the rated voltage of < 70% UN charging and discharging once every 45 seconds can run continuously.
Products Introduction
Very Low-Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
Technical Parameter
1 output frequency 0.1Hz 0.05Hz 0.02Hz 0.01Hz
2 Loading capability : Table 1 for reference
0.1 Hz maximum 1.1F
0.05 Hz maximum 2.2F
0.02 Hz maximum 5.5F
0.01 Hz maximum 11.0F
3 accuracy :± (3% of full scale +0.5 KV)
4 voltage waveform distortion 5%
5 condition of use : indoor, outdoor; temperature : -10+40humidity 85%RH
6 power supply AC50 Hz 220V +5%
7 power fuse : output rated voltage Table for reference
Products Introduction
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose the suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05µF. 0.05µF capacitor in parallel to auxiliary output. Below is capacitance of some instrument for your reference.
40KV vlf high voltage generator parameter :
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-40
40kV
(peak )
0.1Hz,1.1µF
20A
Control 6
Body Boost 50
Used for cable and generator with corresponding voltage
0.05Hz,2.2µF
0.02Hz,5.5µF
0.01Hz,11.0µF
Products Introduction
VLF high voltage generator 60KV.The capacity of it is 1/500 of traditional way. Greatly simplify testing procedures, That is why commonly used in the developed countries, china ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to China's made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (µF/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-60
60kV
(peak )
0.1Hz, 0.5 µF
25A
Control 6
HV TANK-I30
HV TANK-II 33
25KV and below the cable Generator
0.05Hz, 1.0 µF
0.02Hz, 2.5 µF
0.01Hz, 5.0 µF
Precautions
1.Please use the STOP button and discharge by rod then shut down the power if you need to discontinue the machines which in the high pressure conditions.Otherwise it will damage the instrument!
2.Please operation it according to the screen instructions.
3.It is a normal phenomenon to see small amount of oil spill after boosting the pressure because the insulating oil in the booster is full, besides, it will not affect your use.
4.When carrying out 10KV cable test, one-phase test is strongly suggested. The voltage shall be 18KV and the frequency shall be 0.1Hz 0.05Hz 0.02Hz 0.01Hz. The manual said load capacity is the theoretical value, the scene 10KV cable length can reach 3-20km.
Product description
Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Electrical parameters
Electrical parameters
Accuracy class
0.05, 0.1
Power supply
Single phase AC 85-265V, 50 60 Hz
AC Voltage output
Range
57.7V 100 V 220V 380V, Switch automatically max 500V
Adjustment resolution
0.01, 0.1, 1, 10
AC Voltage output
Range 57.7V 100 V 220V 380V, Switch automatically max
Adjustment resolution 0.01, 0.1 1, 10,
Accuracy 0.05 RG
Stability Better than 0.01 RG 1min
Distortion degree Better than 0.1 not capacitive load
Load capacity 40VA
Full load regulation rate Less than 0.01 RG
Full load regulation time Less than 1ms
Temperature drift 8 PPM C
Long-term stability 60 PPM year
Product Description
ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.
Product Characteristics
1 Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1A, shock resistance current 0.1A.
3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .
4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.
5 75% MOA voltage switch button, simple and convenient testing arrester.
6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
Rated parameter value
Rated nominal voltage±450kV
Rated voltage ±150kV
Rated energy 20kJ
Total impulse capacitance 0.25F
The total series ï¼? 3 series
Rated power capacityï F
The following waveforms can be generated when the load capacitance is 300~5000PF
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
Products Introduction
VLF high voltage generator 70KV instrument can be widely used in cables, large-scale high-voltage rotating motors, and power capacitors for AC withstand voltage tests. The advantage is that the instrument is small in size, light in weight, and large LCD display.
VLF high voltage generator 70KV
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-70
70kV
(peak )
0.1Hz, 0.5F
25A
Control 6
HV TANK-I 30
HV TANK-II 33
30KV and below the cable Generator
0.05Hz, 1.0µF
Products Introduction
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose the suitable products for test ï¼?
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05µF. 0.05µF capacitor in parallel to auxiliary output. Below is the capacitance of some instrument for your reference.
Product Introduction
Insulation resistance tester dedicated to the measurement of water-cooled generator test but also can be used for laboratory or field testing insulation testing to do. Output current greater than 25mA. The maximum output voltage of 2500V. Includes high-precision micro-current measurement system digital boost system. Just use a high-voltage lines and a signal line connecting the test product can be measured. Automatic measurement the results from the large screen liquid crystal display and store the results.
Product Characteristics
First the main features
1. 32-bit micro-controller Chinese user interface easy to operate.
2. Automatically calculates the absorption ratio and the polarization index and automatically save 15 seconds 1 minute 2 minutes 10 minutes to facilitate analysis of data per minute.
3. Output current (2500V the output is greater than 25mA) short-circuit currents greater than 40mA.
4. A fully enclosed high-voltage generator module technology the protection of the internal resistance safe and reliable.
Anti-interference ability to meet the EHV substation on-site operation.
5. Automatic discharge test is completed and real-time monitoring the discharge process.
Product Introduction
It is suitable for evaluating the insulation quality of high voltage transformergenenratorling-distance power cable and busbar under strong interference in the field of high-voltage substation and power plant.Specially used for 110KV and above large capacity transformer and long distance power cable power system
Product Characteristics
1.Strict accordance with the safety standards for design with 5 range: 500V 1000V 2500V 5000V 10000V test up to 10T�©.
2.This instrument has the function of automatic calibration and calibrate precision automatly before test
3.Actual test object live voltage measurement functionmeasure leakage currentdischarge automatly.
4.automatic measure and remenber R15Sã??R60S ã??R10min valueAutomatic display polarization index (PI) induced electric absorption test values than (DAR)and test time.
5.Anti-jamming performance is superior the interference current reaches 600 mA still ensure accuracy of test instruments.
6.Automatic discharge:quickly discharge for capacitive test object by advanced high-voltage discharge technology and real-time measurement of discharge voltage (test voltage to 0v) .
7.powered by internal rechargeable lithium battery or ac power supply the real ac and dc dual use does not affect the test accuracy.
8.digital displayautomatic display battery level and undervoltage alarm protection function.
9.Short circuit protection short circuit condition will not burn out the instrument
Products Introduction
The power department did some tests to solve some problems. According to theories and test results at home and abroad, the 50KV Very Low Frequency high voltage generator withstand voltage test can solve this problem. Its advantages are that not only the test results are the same, but the instrument size is small and the weight is greatly reduced.
output rated voltage power fuse Refer to the following table
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-50
50kV
(peak )
0.1Hz,â?¤1.1�µF
20A
Products Introduction
VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (F/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-60
60kV
(peak )
0.1Hz,0.5F
25A
Control 6
HV TANK-30
HV TANK-II33
25KV and below the cable
Products Introduction
Ultra-low frequency dielectric strength testing is another method of power frequency withstand voltage testing, because large-capacity testing is required, and large-scale equipment is not only expensive, but also bulky. The power department did some tests to solve these problems. According to domestic and foreign tests, this product can solve this problem. Not only the size of the instrument is small, but the weight is greatly reduced.
Precautions
When carrying out 35KV cable test, one-phase test is strongly suggested. Voltage is set to 60KV (General Requirements)-78KV (according to the rules needed) and the frequency is set to 0.1Hz, 0.05Hz,0.02Hz and 0.01Hz. The manual said load capacity is the theoretical value, the scene 35KV cable length can reach 3-15 km.
In case the cable is too short(less than 500 meters), the capacitance of the test object is smaller than 0.1 F and the pressure cannot be normally boosted, please connect 0.1 F high-voltage capacitance in parallel way.
Keep high-voltage terminals nylon spin by the above numbers to the corresponding nylon seat, high-voltage lines to ensure good contact , no contact is good , it will cause a discharge , burned the high side . When nylon terminals tightened, pay attention to the intensity, excessive tightening may damage the nylon terminals.
80KV 0.1HZ VLF high voltage generator
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-80
80kV
(peak )
25A
Product description
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor
Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard
Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates
Impulse voltage generator (2)
Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);
(2)Truncated wave: cut-off time (2-6) 10% s, zero-crossing coefficient 0.3%
(3)Standard operating impulse voltage wave 250 20% s / 2500 60% s,
The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
7, the lowest output voltage is greater than 10% of the nominal voltage
8. Duration of use: Above 70% of rated voltage, it can be continuously operated every 120 seconds after charging and discharging. It can be continuously operated after charging and discharging every 60 seconds under 70% of rated voltage.
One computer is used for control and waveform analysis 18-inch LCD monitor, strong anti-interference and long life
WINDOWS XP, OFFICE 2003, LabVIEW related driver software, ACE measurement and control software package,built in
Product description
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: -5 ~ +40 Relative humidity: 9020 Use of the environment: indoor
Non-conductive dust Grounding resistance < 0.5 No fire or explosion hazard
Earthquake resistance: 8 magnitudes There is no gas that corrodes metal and insulates
Insulation resistance tester dedicated to the measurement of water-cooled generator test but also can be used for laboratory or field testing insulation testing to do. Output current greater than 25mA. The maximum output voltage of 2500V. Includes high-precision micro-current measurement system digital boost system. Just use a high-voltage lines and a signal line connecting the test product can be measured. Automatic measurement the results from the large screen liquid crystal display and store the results.
Product Characteristics
First the main features
1. 32-bit micro-controller Chinese user interface easy to operate.
2. Automatically calculates the absorption ratio and the polarization index and automatically save 15 seconds 1 minute 2 minutes 10 minutes to facilitate analysis of data per minute.
3. Output current (2500V the output is greater than 25mA) short-circuit currents greater than 40mA.
4. A fully enclosed high-voltage generator module technology the protection of the internal resistance safe and reliable.
Anti-interference ability to meet the EHV substation on-site operation.
5. Automatic discharge test is completed and real-time monitoring the discharge process.
Product Description
ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.
Product Characteristics
1 Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1�µA, shock resistance current 0.1µA.
3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site .
4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.
5 75% MOA voltage switch button, simple and convenient testing arrester.
6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
Product Description
450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test
Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below.
Product Characteristics
Rated parameter value
Rated nominal voltage ±450kV
Rated voltage ±150kV
Rated energy 20kJ
Total impulse capacitance 0.25F
The total series 3 series
Rated power capacity1F
Product Description
ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.
Product Characteristics
1ã??Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: -5 ~ +40 Relative humidity: 900 Use of the environment: indoor
Non-conductive dust Grounding resistance < 0.5 �© No fire or explosion hazard
Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates
Overview
Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Product Introduction
3-phase energy meter calibrator introduction:
HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
Product Characteristics
3-phase energy meter calibrator introduction:
TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
3-phase energy meter calibrator technical parameters:
Input feature
Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range.
Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional)
Phase angle measuring range: 0 ~ 359.999
Frequency Measurement Range: 45 ~ 55Hz.
Product Introduction
Digital double clamp Phase voltammeter is a high-precision low-price hand-held double-channel input measurement instrument designed for voltage current and Phase measurement on site.Using this meter the phase between u-u i-i and u-i can be easily measured in the field the phase sequence of sensitive and capacitive circuits and three-phase voltage can be distinguished the wiring group of transformers can be detected the secondary circuit and bus differential protection system can be tested the phase relationship between CT of each differential protection group can be read out and the wiring of the electricity meter can be checked.The tongs current transformer is used to input the measured current so there is no need to disconnect the measured line.When measuring the phase between u1-u2 the two input circuits are completely insulated and isolated so it completely avoids the possible short-circuit of the measured circuit caused by wrong wiring and thus burns out the measuring instrument.The display screen USES high-contrast Liquid crystal display with words up to 25mm and The screen Angle can be freely converted to about 70�° to obtain better visual effects.
Digital double clamp Phase voltammeter enclosure USES engineering insulation materials another rubber vibration protection sleeve safe and reliable.
Product namesï¼?Phase meter double clamp Phase meter double clamp Phase voltammeter clamp forms a table clip-on Phase voltammeter Digital Phase double clamp Phase meter Digital double clamp table low-pressure volt-ampere Phase inspection table hand-held Digital double clamp Phase voltammeter double clamp type Digital Phase meter double clamp Digital Phase meter double clamp type volt-ampere Phase meter double clamp volt-ampere Phase table double clamp Phase meter Digital display double clamp Phase voltammeter
Product description
Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source.
Technical index
Electrical parameters
Accuracy
0.05%, 0.1%
Power Supply
One Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output
Range(U1,U2,U3)
57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range
(0-120)%RG(1)
Adjustment �neness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Electrical parameters - continued
AC Voltage Output - continued
Stability
0.01%/120s
Distortion
0.3% (Non-capacitive load)
Output load
each phase 25VA
Measuring accuracy
0.05%RG
AC Current Output
Range(I1,I2,I3)
200mA, 1A, 5A, 20A, 100A
Adjustment range
(0-120)%RG
Adjustment �neness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
Product description:
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
Technical index:
Electrical parameters
Accuracy class
0.05%, 0.1%
Resolution
6 TFT (640-480)
Electrical parameters - continued
Power supply
220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port
RS232
Test voltage
Range
5-480V
Error
±0.05% (30V-480V)
±0.1% (5V-30V)
Harmonic
2nd-63st
Test current
Range (direct connection)
5mA-20A
Error (direct connection)
±0.05% (100mA-20A)
±0.1% (10mA-100mA)
Range (clamp CT)
10mA-3000A
Error (camp CT)
�±0.2% (100mA-100A)
±0.5% (100A-3000A)
Harmonic
2nd-63st
Product description
Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Feature
1. Current clamp and meter combined together, colorful and touch-screen display;
2. One AAA Li-battery can continuously working 4 hours;
3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A;
4. Display all the measuring parameters in one screen;
5. Current clamp has automatic compensation function, 0.2% class accuracy;
6. Current clamp has automatic calibration function;
7. Integration design of the meter and clamp;
8. 16bit high accuracy AD switch 32 bit ARM processor core.
9. Automatically record and save 999 groups calibrate data;
10. Micro-multifunction optic sampler
Technical index
1. Manual/automatic test inductive single phase meters;
2. Manual/automatic test electric single phase meters;
3. Measure virtual value of alternating voltage (15~300Vrms);
4. Measure virtual value of alternating current (50mA~120Arms);
5. Test parameters: active power, phase angle of voltage and current, frequency and etc;
6. Automatic store testing data, and 999 group test results can be saved.
Product description
The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source.
Technical index
Electrical parameters
Accuracy class
0.05%, 0.1%
Power Supply
One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range
57.7V, 100V, 220V, 380V; max 500V
Adjustment range
(0-120)%RG(1)
Adjustment
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
0.01%/120s
Electrical parameters - continued
Distortion 0.2% (Non-capacitive load)
Output load max 25VA
Measuring accuracy 0.05%RG
Product description
Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system.
When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.
3 phase handheld power quality analyzer Technical index
Input characteristics
Voltage measuring range 0 200V 800V, automatic cutting gear.
Current measurement range
Clamp transformers three types 5A 25A standard
100A 500A optional
400A 2000A optional
Phase angle measuring range 0 359.99
Frequency measurement range: 45 55Hz.
Voltage channels three channel UA UB UC
Current channels three channel IA IB IC
Maximum harmonic analysis times 63 times.
Maximum continuous storage period in 1 minute interval: 18 months.
Accuracy
Measurement of electrical parameters section:
Voltage 0.2%
Frequency 0.01Hz
Current, power 0.5%
Phase 0.2
Power quality section
Fundamental voltage tolerance 0.5% F.S.
Fundamental current tolerance 1% F.S.
Phase between fundamental voltage and current measurement erro0.2
Overview
Three phase phase volt-ampere meter a high precision instrument for measurement of three phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Specifications
TYPE
MEASUREMENT RANGE
UNIT
ERROR
RESOLUTION RATIO
Voltage
1 600
V
0.5 measuring range
0.01V
Current
0.001 10
A
0.5 measuring range
0.0001A
active power
0.001 5000
W
0.5 reading PF 1
0.1W
reactive power
0.001 5000
VAR
0.5 reading PF 0
0.1VAR
apparent power
0.001 5000
VA
0.5 reading
0.1VA
frequency
45 65
HZ
0.1 reading
0.01HZ
phase position
0 360
2
0.1
Product Introduction
This instrument is developed and designed according to the national power industry standard DL/ t506-2007 "insulation gas humidity measurement method for sulfur hexafluoride electrical equipment" and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Product nickname intelligent micro water meter micro water meter micro quality meter.
Product description
Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Electrical parameters
Electrical parameters
Accuracy class
0.05, 0.1
Power supply
Single phase AC 85-265V, 50 60 Hz
AC Voltage output
Range
57.7V 100 V 220V 380V, Switch automatically max 500V
Adjustment resolution
0.01, 0.1, 1 10,
Product description
The portable Three-phase standard power source is suitable for metering departments, power distribution terminals, power management, reactive power compensation devices and enterprise production.
Technical index
Electrical parameters
Accuracy class
0.05%, 0.1%
Power supply
Single phase AC 85-265 V, frequency 50/60 Hz
AC Voltage output
Range (U1, U2, U3 phase)
57.7V/100V/220V/380V; range switch automatically
(Max 500V)
Electrical parameters - continued
0.01% RG
Accuracy
0.05% RG
Stability
Product description
Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory.
Technical index
Portable Three-phase Standard Meter
Electrical parameters
Accuracy class
0.05%
Voltage supply
Range
5V-480V
Error
Display range
5.000000V-480.0000V
Harmonic
2nd-63st
Range
1mA-120A
Error
Display range
1.000000mA-120.0000A
Active power
0.05% (0.01A-0.2A)
Reactive power
Apparent power
Active energy
This instrument is developed and designed according to the national power industry standard DL/ t506-2007 "insulation gas humidity measurement method for sulfur hexafluoride electrical equipment" and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Product nickname intelligent micro water meter micro water meter micro quality meter.
Product description
Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system.
When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.
3 phase handheld power quality analyzer Technical index
1. Input characteristics
Product description
Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory.
Technical index
Portable Three-phase Standard Meter
Electrical parameters
Accuracy class
0.05%
Voltage supply
Range
5V-480V
Error
Display range
5.000000V-480.0000V
Harmonic
2nd-63st
Range
1mA-120A
Error
Display range
1.000000mA-120.0000A
Active power
Product Introduction
The product combines modern advanced digital variable frequency technology and microcomputer control together therefore it can realize the full automatic voltage boost step down measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display and can display the output wave form.
Product Characteristics
VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus.
1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms.
3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Product description:
Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices.
Major Technical Index
1. Environmental conditions
Temperature 5 40 Humidity:
Overview
Cable check and cable, cable lookups are a bit a bit of arbitrary wiring no need to publicly line. It can greatly improve the construction progress, which is a new test tool in on site construction such as electricity, telecommunications, automation control.
The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate.
Technical parameter
Parameter Display the maximum row of LEDs 1000, the maximum distance of the quilt is 40km 1.5mmmmmmmmma
size Transmitter Size 135 70 24MM Receiver Size 135 70 24mm
Function
The entire instrument consists of a transmitter and a receiver;
There is no need to determine the public line to make it easy to use
Wire recognition, distribution, application to a part of the wire or multi-heeled wire
One item can be identified, if you need to distinguish more wires can measure or use multiple instruments
Can determine whether there is a short circuit or disconnect between the wires
The receiver is also a disconnect detector that can be used to measure whether the wire is turned on
The structure is small and easy to operate.
Product description
Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .
Technical index
Measuring range and accuracy
(Temperature, humidity: 235, 45 75%RH)
Model
BC2305
Rated
Voltage
250V
500V
1000V
2500V
5000V
Measuring Range
0.099.9M
product brief introduction Product Introduction
The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
warning
1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit.
2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity.
3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire.
4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software
2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion
3. RAM system large color LCD display massive information can be seen directly through screen
4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency
5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm
6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional)
7. With 485 communication interface can do various communications test for universal meters
Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply.
1 the company's Triple frequency transformer is simple to operate reliable performance
2 can well meet the needs of transformers transformers withstand voltage
Product Introduction
Insulation boot (glove) withstand voltage is designed and manufactured by our company according to the test procedure of insulated boots (gloves) and in accordance with the opinions of users. Insulation boot (glove) withstand voltage uses automatic (lower) voltage to automatically read out the leakage current of each test item. The whole test process is completed automatically and the test data is automatically printed which effectively solves the irregular test method in the past. This simplifies the testing procedures and improves the testing speed. More reliable identification of the leakage current of the insulated boots (gloves) power frequency withstand voltage and other parameters. It is the ideal equipment for insulating boots (gloves) to ensure the safety of test workers. Its main features: test 6 test items at the same time and read the leakage current of each test item to accurately judge the unqualified test items; the test vehicle is equipped with casters at the bottom for easy movement using a large white light display under strong light Still clearly visible with a one-click shuttle easy to operate with a good interactive experience.
product features Product Characteristics
1 automatic and fast: the use of high-fine stepper motor to control the voltage regulator boost process according to the national standard test parameters fully automatic pressure test. After the test starts the instrument automatically closes and automatically boosts the boosting speed according to the national standard. It reaches the scheduled voltage and starts to count and keeps the test voltage. It automatically depressurizes the timer until the preset time. After zero the power is automatically turned off indicating that the test is over. Display each sample leak Current and display the test result
2 full-featured: full Chinese interface work status display simple and clear operation wide application; with status display with reminder function the user can see the status of the device at a glance; rotate the mouse operation all functions can be rotated by one Mouse setting all digital adjustment abandoned the old potentiometer adjustment mode the field is very convenient to use; button directly set the target Voltage leakage Current pressure time application freely
3 intelligent security protection: with Current over the protection of the Voltage. Accurate and fast protection ensuring the safety of personnel and equipment
Product Introduction
Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply.
product features Product Characteristics
1 the company's Triple frequency transformer is simple to operate reliable performance
2 can well meet the needs of transformers transformers withstand voltage
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement.
1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ;
2. High Anti-interference ability accurate and reliable measurement;
3. Easy operation equipped with large LCD and American rotating mouse and micro printer
4. Simple wiring only connecting with tested down leads to finish all line parameter measurement
5. High speed micro-controller as inner core integrated structure
6. Fast testing process one sequence parameter testing time is 1 min
7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Product Introduction:
AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
xc control cabinet Technical Paramenters:
environment temperature 0-40
altitude < 100m
relative humidity < 85%
Main product specifications
type specification capacity power source output operating mode Refer to the weight
anthroposcopy (V) (A) (V) (A)
XC-2 2 1 220 50 0-220 10 manual operation 14
XC-3 3 1 220 50 0-220 15 manual operation 16
XC-5 5 1 220 50 0-220 20 manual operation 18
xc
Overview
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
Technical index
Rated voltage
Quality factor under full load in test of fire power generator Q 10 relating to load
Quality factor under full load in cable test Q 30 relating to load
Quality factor under full load in test of main transformer: Q 30 relating to load
GIS, the quality factor under full load in switch test and other tests Q 50 relating to load
Input power supply single phase of 380V
Frequency adjustment range 20Hz 300Hz
Accuracy of system measurement 1.5
The unit possesses protective functions, such as over voltage, over current and zero start.
Description for main configuration and technical data of equipment
One set of variable-frequency power supply
Rated power 10kVA;
Input voltage single phrase of 220V or three phase of 380V 10 and 45 65Hz
Output voltage 0 400V adjustable
Output voltage frequency 30 300Hz
0.1Hz adjustable stepping
Instability degree of frequency 0.02
Output current: 0 25A
Overview
The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on site debugging experience and user communication in and has been re designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.
Technical parameter
Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01
The AC current is in the range of 10A-100kA, error no more than 0.03
Current resolution current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V
The AC voltage is within 100V 1000kV range, error: no more than 0.03
Current resolution: current is 0.001V in the range of 0V-1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
Product Introduction
Dc Hipot Test Equipment for the power supply department, for example: DC HV withstand and leakage current test in power cables, the conductance current and 1mA reference voltage of magnetic blow out arrester and zinc oxide arrester test.ZGF DC Hipot Test Equipment supplies 60kV to 400kV from 60kV to 400kV is DC high voltage power supply equipment.It has functions of switch on protection under 0 voltage,over voltage and over current protection.They are high stability and reliability. ZGF is easy to operate , small in size and light in weight.
product features Product Characteristics
1 Series dc high voltage generators have small ripple coefficient stable and reliable voltage output no noise and good reliability
2 with overvoltage overcurrent zero voltage start and fault protection voltage protection value can be set display intuitive
3 voltage current using digital display and power supply has a reading easy to monitor the output status
4 with 0.75 times voltage conversion easy to test zinc oxide arrester
5 the product structure is compact small size easy to carry
VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus.
1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms.
3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation
1) AC/DC analog value input measurement
2) state variables input measurement
3) remote control execution testing
4) remote regulation function testing
5) digital value input testing
6) impulse input testing
2. AC Power source
It can output AC voltage AC current
accuracy 0.05 class
can provide standards of AC/DC voltage/current power phase power factor frequency energy.
Output method and output electric quantity can be set arbitrarily
3. Data management
It can save search browse print or delete RTU testing data.
Calibrated parameters can be saved permanently
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control
1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter
2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs
3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability
4. With RS232 and USB(optional) communication interface for PC connection
5. With aluminum alloy carrying box which look nice and with little weight
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault.
After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent.
The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
Product description
Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry.
Technical Parameter
CTA-1000
Usage
CT PT
Output
0~180Vrms12Arms36Apeak value
Voltage measurement accuracy
0.1%
CT Ratio
Range
1~40000
accuracy
0.05%
PT Ratio
Range
1~40000
accuracy
0.05%
Phase
Range
2min
accuracy
0.5min
DC resistance
Range
0~300
accuracy
0.2%2m
Burden
Range
0~1000VA
accuracy
0.2%0.02VA
0.2%0.02VA
Power supply
AC220V 10%50Hz
Environmental Conditions
Operating temperature -10C~50C Humidity 90%
Weight and Dimensions
Dimensions 365 mm290 mm153mm,Weight
Overview
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
Main Technical Parameters:
Booster output current & voltage
1A/2500V
2A/1500V
5A/600V
10A/220V
20A/30V
Current generator output current
600A
Output power
3000VA
Voltage and current measurement accuracy
CT ratio tests
Range
1 -40000
Voltage method / current method
Accuracy
PT ratio tests
Range
1 - 40000
Accuracy
Overview
The transformer integrated test system complies with GB1094, GB / T4776, GB / T5169 and other relevant national standards. With the increase in transmission and electrical power generation and the continuous increase in power grids, the successful transformation of the national city network, the farnet, and the number of online quantities and capacity of power transformers are increasing.
Technical parameter:
Equipment measurement range and precision Voltage metering range: 50V 500V
Voltage metering accuracy: 0.2%
Current metering range: 0.1a 5a (can be 0.1A 1A)
Current metering accuracy: 0.2%;
Power frequency withstand voltage test Leak current: 400mA
Input current monitoring instrument Monitoring range: 200A
Function:
Equipment failure automatic detection function, automatically detect peripherals, such as: the voltage regulator is zero, etc .;
Test item: no-load loss measurement, no-load current percentage (automatic conversion to the value of the rated voltage), load loss measurement, the impedance voltage percentage (automatic conversion to the rated current reference temperature) Automatic measurement (voltage ratio measurement, connection group label test), external pressure test (power frequency withstand voltage test), induction pressure test (multiplier multiplier test), insulation resistance measurement, lightning shock test, insulation Oil test (breakdown voltage, flash point, acid value, volume resistivity, moisture, etc.), local discharge test, temperature rise test
Product description
Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.
A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves).
The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment.
Technical Parameters
Input voltage AC220V 50 Hz
Output voltage 0~30kV
Capacity 3kVA
Test number 3 pairs each time
Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Insulated boots gloves withstand voltage
Overview
This device is designed and manufactured for 35kV cable AC withstand voltage test. The reactor is individually designed for multiple units, which can not only meet the test conditions of high-voltage and low-current equipment, but also meet the low-voltage AC withstand voltage test requirements of 10kV cables.
The special AC resonance test system for cables adopts the method of adjusting the frequency of the power supply, so that the reactor and the capacitor under test can achieve resonance, and the high voltage and large current can be obtained on the test product. It is a new method of current high voltage test and The trend has been widely used at home and abroad.
The AC resonance test system uses a dedicated SPWM digital waveform generator chip with a frequency resolution of 16 bits, and the frequency fineness can reach 0.1 Hz at 20 to 300 Hz; it adopts an orthogonal non-synchronous fixed carrier modulation method to ensure that the entire frequency The output waveform is good in the interval; the advanced IPM module is used in the power part to ensure the stability and safety of the instrument under the minimum weight.
The test system consists of a frequency and voltage regulation power supply, an excitation transformer, a reactor, and a capacitor divider.
Technical index
1. the resonant excitation power supply only needs 1/Q of test capacity, which is 1/10-1/30 of common test unit and reduces the system weight and volume greatly.
2. Rated voltage:
1.108kV meeting the alternating current withstand voltage test for 35kV cable;
2.Waveform distortion rate of output voltage should be less than 1.0
3.The permissible continuous working time is to work for 5 minutes at one time under rated condition.
4.Quality factor of unit itself: Q 50
Advantage
1.The power capacity needed is reduced greatly.
2.The weight and volume of equipment is reduced greatly.
3.The waveform of output voltage is improved.
4.The large short-circuit current is prevented from burning fault point.
Feature:
1. A large number of cables with voltage levels of 35kV and below are used, and the test workload is large, so this type of withstand voltage test device is small in size and light in weight, and a portable cable withstand voltage test system was born;
2. This system requires that the weight of the parts that a single person can move on-site does not exceed 30kg, and the weight of the parts that two people can move on-site does not exceed 60kg, which is suitable for on-site transportation;
3. The power supply adopts 220V single-phase power supply or 380V single-phase power supply, which is convenient for on-site power supply;
4. The reactor part is made of dry epoxy casting, which is beautiful and reliable, suitable for the requirements of various cables;
5. The withstand voltage test of 110kV and above cables adopts oil-immersed reactors.
Overview
The system is suitable for high-voltage 10KV, 35KV low voltage 400V capacity 5000kVA and the following transformer factory test and voltage 10kV capacity 3150kVA and below the distribution transformer no-load test, load test, variable ratio measurement, DC resistance measurement, power frequency withstand voltage test, sensitive The pressure test is integrated integrally integrated, digitized, reducing mechanical faults and reading errors, improves the accuracy and applicability of the overall test system, making the factory trial easier and faster.
Technical parameter
High pressure 35K, low pressure 400V capacity 5000kVA or less dry press factory test High pressure 10K, low pressure 400V capacity 5000kva dryer factory test High pressure 10K, low voltage 400V capacity 3150kVA or less oil immersion press factory test
Voltage transformer metering range and accuracy Voltage Transformer Range: 100V 3.6kV
Voltage transformer gear: 3.6kV, 2kV, 1.2kV, 0.6kV
Current transformer accuracy: 0.05%
Power frequency withstand voltage test Leak current: 300mA
Output voltage: 100kV
Function:
The system has two operating modes (two ways to lock each other, can only work in an operation) automation, flexible design, high integration, complete function
1. Design with touch panel and mask button massive information to see and simple to use
2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference
3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection
4. Three phase rated current rated voltage can be preset by users
5. Multiple choose of voltage current phase testing point
6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters
7. Large memory for data storage and searching data is very convenient
8. With R232 communication interface for PC control and software upgrade
1. 5 LED digitally display output by actual value or by percentage
2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional)
3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V
4. Three AC frequencies for option: 50Hz 60 Hz 400 Hz
5. Auto protection or manual resetting function for over load
6. Over load rang is 10% for each level of voltage current
7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
Product Introduction
TKJF fit for many products it has high sensitivity high S/N a large screen which has clear testing wave displaying high frequency ellipse scan (the power is less than 1VA). auxiliary zero marking system. The discharge meter has pointer/digital display and linearity /digital function. The amplifier has large dynamic range 9 kinds of frequency band combinations.
TKJF is a powerful tool for developing new high voltage electric products and improving the quality of the products. It is also an efficient testing device to judge the work condition of equipments on the work field. This device is used together with model JZF-9 or JZF-10 calibrator.
product features Product Characteristics
Working Principle
When measured piece Cx has partial discharge under testing voltage the circuit will have pulse current which get by the input unit. The pulse signal is amplified by front amplifier and the frequency band is chose by filter amplifier then been amplified to needed amplitude by the main amplifier. The pulse signal will be displayed on oscillograph screen. The pulse value is also sent to the pulse peak meter and displayed immediately. The time window unit chooses a working period of the pulse peak meter during each cycle of testing voltage and it increases the brightness of the relevant displaying area in this time. In this way it can avoid the disturbing of fixed phase.
Input discharge volume to the measured piece Cx through JZF series PD external calibrator adjust the fine adjusting knob till the displayed value is equal to the discharge volume the discharge can be read directly and conveniently on the meter without counting.
The testing voltmeter will have an over zero mark signal of testing voltage through the voltmeter resistance R and the zero mark pulse will be displayed on oscillograph screen. The testing voltage can be displayed on KV meter.
product features Product Characteristics
1 in light weight
2 good-looking appearance
3 capaciousness
4 strong stability
Product Parameter Product Parameters
FY96-H Current Transformer Load Box
environmental conditions temperature 15 25
humidity
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation
1) AC/DC analog value input measurement
2) state variables input measurement
3) remote control execution testing
4) remote regulation function testing
5) digital value input testing
6) impulse input testing
2. AC Power source
It can output AC voltage AC current
accuracy 0.05 class
can provide standards of AC/DC voltage/current power phase power factor frequency energy.
Output method and output electric quantity can be set arbitrarily
3. Data management
It can save search browse print or delete RTU testing data.
Calibrated parameters can be saved permanently
1. Design with touch panel and mask button massive information to see and simple to use
2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference
3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection
4. Three phase rated current rated voltage can be preset by users
5. Multiple choose of voltage current phase testing point
6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters
7. Large memory for data storage and searching data is very convenient
8. With R232 communication interface for PC control and software upgrade
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software
2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion
3. RAM system large color LCD display massive information can be seen directly through screen
4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency
5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm
6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional)
7. With 485 communication interface can do various communications test for universal meters
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control
1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter
2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs
3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability
4. With RS232 and USB(optional) communication interface for PC connection
5. With aluminum alloy carrying box which look nice and with little weight
Product Introduction
3-phase energy meter calibrator introduction:
HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
Product Characteristics
3-phase energy meter calibrator introduction:
TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
3-phase energy meter calibrator technical parameters:
Input feature
Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range.
Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional)
Phase angle measuring range: 0 ~ 359.999
Frequency Measurement Range: 45 ~ 55Hz.
Product Description
450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test
Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below.
Product Characteristics
Rated parameter value
Rated nominal voltage±450kV
Rated voltage ±150kV
Rated energy 20kJ
Total impulse capacitance 0.25 F
The total series 3 series
Rated power capacity 1 F
This instrument is an instrument which is specially used for transformer loss parameters and line frequency parameters testing. The instrument has the advantages of ingenious design excellent performance and powerful functions. The interior adopts advanced multi A/D synchronous sampling and digital signal processing technology and successfully solves the problem of multi-channel signal synchronous measurement and calculation. The instrument adopts large screen liquid crystal display Chinese menu prompt simple operation equipped with high-speed thermal printer and has storage function convenient for data storage and printing. The instrument is small in volume light in weight easy to carry and is very convenient to use in the field. It greatly reduces the labor intensity of the experimenters and improves the working efficiency.
1. Large LCD display simple menu operation.
2. With thermal printer storage function.
3. Small volume and light weight suitable for field work.
Product Introduction
Single Phase Relay Test Set General
TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay.
Product Characteristics
Single Phase Relay Test Set Main Features
1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range.
2 Maximum Output Current:0150Aã??
3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state.
4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement.
5 Light-weight design, small-volume, and fully-functional.
Product Parameter
1. It can output three-phase 0-500a current at the same time.
2. It can synchronously test the action time of thermal relay thermocouple and motor protector.
3. Normally open and normally closed contact detection.
4. Several calibrations can be connected in series at the same time to improve working efficiency.
Product Parameter
1. AC current output: 0-500a (customizable)
2. Digital AC ammeter: 4 ½ 0.5 class accuracy
A. Digital timer
Timing length: 0 ~ 999.999 seconds
Error: class 0.2 accuracy
B. Boundary dimension: 44 30 34cm
C. Weight: 7kg
Product Introduction
Single Phase Relay Test Set General
TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay.
Product Characteristics
Single Phase Relay Test Set Main Features
1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range.
2 Maximum Output Current:0150Aã??
3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state.
4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement.
5 Light-weight design, small-volume, and fully-functional.
TKRJ- electronic thermal relay calibration is mainly used for setting and calibration of various thermal relays and motor protection devices. Because of its reasonable design convenient operation and high output power it is widely used in electric test sites of power system railway petrochemical metallurgical and mining enterprises.
1. It can output three-phase 0-500a current at the same time.
2. It can synchronously test the action time of thermal relay thermocouple and motor protector.
3. Normally open and normally closed contact detection.
4. Several calibrations can be connected in series at the same time to improve working efficiency.
Product Introduction
Single Phase Relay Test Set General
TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay.
Product Characteristics
Single Phase Relay Test Set Main Features
1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range.
2 Maximum Output Current:0150A
3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state.
4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement.
5 Light-weight design, small-volume, and fully-functional.
1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output.
2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate.
3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc.
4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc.
5. Switch quantity contact is rich three - phase for 7 contact input and 2 pairs of empty contact output. The input contacts are compatible with 0 ~ 250V potential contacts and can be identified automatically. Input and output contacts can be expanded according to user needs.
6. Large screen LCD display microcomputer relay protection tester adopts 320Ã??240 lattice large screen high-resolution graphics LCD display all the operation process are set on the display screen the operation interface and test results are displayed in Chinese the display is intuitive and clear.
7. Self-protection adopt reasonable design of heat dissipation structure and have a variety of reliable and perfect protection measures and power soft start and a certain fault self-diagnosis and locking function.
8. With an independent dedicated dc power output the device is equipped with one 110V and 220V dedicated dc power output.
9. High cost performance belongs to the cross - professional joint design products integrated multi - professional advanced scientific and technological achievements. Both large tester performance and small tester price with a high performance ratio.
Product Introduction
SF6 switch is a widely used high voltage electrical appliance in the power system. SF6 gas density relay is an important element used to monitor the variation of SF6 gas density in the SF6 switch body during operation. Its performance directly affects the operation safety of SF6 switch.Due to the infrequent operation of SF6 gas density relay in the field it is often found that the operation is not flexible and the contact contact is not good after a period of time and some of the temperature compensation performance of the density relay becomes worse. When the ambient temperature changes suddenly the SF6 density relay often misoperates.Therefore DL/T596-2005 "precautionary test regulations for power equipment" stipulates that each SF6 switch user should verify SF6 gas density relay regularly.From the perspective of actual operation it is necessary to carry out regular calibration of SF6 density relay and pressure gauge in field operation.
The check pressure sensor with high precision and high speed A/D converter combining with the 32 bit high performance microprocessor can check the performance of A variety of SF6 gas density relay can accurately measure the movement of the signal when the current temperature pressure value arbitrary automatically when the environment temperature of 20 â?? conversion standard pressure and have A print store and U disk offload function at the same time the fault in the process of automatic identification test.Sf6 gas density relay calibrator is convenient to carry simple to operate high test accuracy strong stability and good reliability which reflects the characteristics of "intelligent" instrument.
Product Parameter
1. It can output three-phase 0-500a current at the same time.
2. It can synchronously test the action time of thermal relay thermocouple and motor protector.
3. Normally open and normally closed contact detection.
4. Several calibrations can be connected in series at the same time to improve working efficiency.
Product Parameter
1. AC current output: 0-500a (customizable)
2. Digital AC ammeter: 4 0.5 class accuracy
A. Digital timer
Timing length: 0 ~ 999.999 seconds
Error: class 0.2 accuracy
B. Boundary dimension: 44 30 34cm
C. Weight: 7kg
Overview
The gas relay calibrator is a tester device that specializes in verification of gas gas relays. The gas relay calibrator is a detection check device for the detection of the Vaste Relay Flow Period Value, Cable Point Value, and Sealing Pressure Value. Gas Relay Calibrator is suitable for more than 90 of Gas Relay checks in .
Gas relay is also known as gas gas relay, is a protective unit in an oil immersion transformer, mounted in an oil pipe under transformer oil pillow. The gas relay detector is a dedicated gas relay pressure release valve calibrator device for the gas relay value, a capacity value, and sealing pressure value, and the gas relay tester uses a microcomputer control technology, and the gas relay tester is detected by detecting a high-precision pressure sensor. When the gas relay tester simulates the internal failure of the transformer, the gas method of the gas relay tester is calculated to calculate the flow rate value to achieve the detection of gas relatives, the Gas protection action value, the gas relay calibrator adopts the fine container combined with the US MCC's micro Press the precision sensor, detect the inside of the gas relay to exclude the liquid volume method to calculate the light gas capacity value
Technical parameter
Portable gas relay calibrator
Protection IP65
Execution standard Compliance with DL T540 1994 standards and IEC
power input 50HZ 220V
Flow speed detection heavy gas 0.1-0.5m s 0.05m s resolution 0.01
0.5-2.5m s 0.1m s resolution 0.1
Maximum error 1
Volume detection light mill
0 300ml resolution 0.01ml
300ml 700ml resolution 0.1ml
Maximum error 1
test method Automatic measurement, semi automatic measurement, manual measurement of three measurement methods
Sealing test
0 150KPA resolution 0.1
0 300KPA resolution 1.0
Comprehensive error
TKRJ- electronic thermal relay calibration is mainly used for setting and calibration of various thermal relays and motor protection devices. Because of its reasonable design convenient operation and high output power it is widely used in electric test sites of power system railway petrochemical metallurgical and mining enterprises.
1. It can output three-phase 0-500a current at the same time.
2. It can synchronously test the action time of thermal relay thermocouple and motor protector.
3. Normally open and normally closed contact detection.
4. Several calibrations can be connected in series at the same time to improve working efficiency.
Product Parameter
Introduction
The SF6 gas comprehensive instrument is a three-in-one tester that integrates, concentration, and main crystallization measuring instruments. It concentrates the achievable capabilities into one and completes three functional tests at a time, which greatly reduces the gas emissions in the equipment and effectively protects the environment. , Pollution, while reducing the user's workload and improving work efficiency.
It is because the sensor of Finland Vaisala is used; the SF6 gas comprehensive supplementary instrument has sufficient performance, and it uses an efficient absorption sensor.
The special instrument adopts the sensor of German HNP; some products adopt the special sensor of imported American Dekang SF6.
The SF6 integrated equipment display adopts a large-screen Chinese display, real-time various parameters, intelligent and intelligent operation, massive information, and dual-use rechargeable batteries.
Energy saving technology, energy saving and environmentally friendly instruments.
The SF6 comprehensive tester adopts the sensor, sensor, SOH2S, CO and other sensors of , and adopts the thermal conductivity type of
Sensors and R&D sensors; more advanced ARM development technology, quality sensors, sensors and other precision sensors, equipped with sensors and sensors are more realistic, more simultaneous, and manufactured. The tester uses a color screen screen display, friendly interface, and easy to operate.
This type of comprehensive tester uses reliable imported sensors as sensitive components, and at the same time integrates real time measurement, curve display, power management, time system, file system, data query, data understanding and other update functions, and integrates advanced sensor technology. And information technology, humanized operation information technology, humanized operation and perfect functions, you can learn her ability and perfection in printing.
Product Introduction:
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.
The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature 0â??-52â??
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
Size 229 65 65mm3
Probe length 35.5cm
Product Introduction:
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.
The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
Product Overview
TKKGG-H Series HV/LV Switch Cabinet Test Bench is mainly applied for ex-work energized testing for high voltage and low voltage cabinet manufacturers. The test bench could provide various AC/DC power source in order to detect switch cabinet.
Features
Reading directly: Digital meters to display current voltage power factor test value.
Measuring accurately: High precision test value is accurate.
Full protections: Each circuit is with air switch protection.
Portable: Small size light weight easy to move.
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. For circuit breakers with closing resistors the closing resistor and switching waveform can be accurately measured. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nicknameï¼?High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-pressure Breaker Analyzer Breaker Analyzer circuit breaker tester switch mechanical characteristic tester switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Overview
Light digital relay protection tester characteristics 4 6 8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850 9 1 2 frame format, Goose, IEEE 1588 packets more support 24 sets of SV packets 64 groups of Goose packets simultaneously 3 5 pairs of 2 10M fiber serial port, can send and receive IEC60044 7 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals
Technical parameter
Fiber Ethernet port
4 6 8 pairs 100 Mbits S, ST, Mode, 1310nm
IEC61850 9 1 2 Le, Goose, IEEE-1588
Send dispersion
Product description
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
Technical index
Electrical parameters
Accuracy class
0.05, 0.1
Resolution
6 TFT 640 480
Electrical parameters - continued
Power supply
220V 10%, 50 60Hz
Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh
Power line supply U1, UN, 85V-265V 50 60Hz
Communication port
RS232
Test voltage
Range
5-480V
Error
0.05% 30V-480V
0.1% 5V-30V
Harmonic
2nd-63st
Product description
Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.
Technical index
Test range: 5A5A~25000A5A or 5A1A~5000A1A
Tested current transformer work scope: 1% 120%
Second load 2.5 VA 300VA, COS 0.8 1.0
Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S
Resistance, admittance measurement errors 5.0%
Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS
Power consumption 20 VA
Accuracy level 0.05 S level
Shape dimension mm 460 L 375 W 183H
Weight kg 10
Feature
HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device.
HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Product description
Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.
Technical index
Product description
The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage
Oil Immersed Testing Transformer 1
Technical index
Model
Capacity
High Frequency Voltage Output Voltage
High Frequency Voltage Output Currentm)
Low Frequency Voltage input
Change
Tempera- ture raised
30 minute
V
A
YD G1.5
1.5
50
30
200
7.5
500
10
YD G 3
3
50
60
200
15
500
10
YD G 5
5
50
100
200
25
500
10
YD G10
10
50
200
220/380
50/26
500
10
YD G 20
20
50
400
380
53
500
10
YD G 30
30
50
600
380
79
500
10
YD G 40
40
50
800
380
105
500
10
YD G 50
50
50
1000
380
132
500
10
Product Introduction
TKJB - 1200 Six phase voltage and six phase current can be output, which has made it is possiable to be any combition, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out differential test of three-phase transformer.
Product Characteristics
1 Meet all field test requirements.The Microcomputer relay protection tester is a standard of six phase current six phase voltage output at the same time the current a/phase 30 voltage125V/phase.Six - phase current in parallel up to 180A.It can not only test the traditional relays and protection devices but also test the modern microcomputer protection especially the transformer differential protection and backup self-switching device the test is more convenient and perfect.
2All kinds of technical indexes have reached the standard of DL/ t624-1997 "technical conditions of microcomputer test equipment for relay protection" issued by the ministry of electric power.
3 Classic WindowsXP operation interface man-machine interface friendly easy and quick to operate;The high-performance embedded industrial control computer and 8.4-inch TFT true-color display with a resolution of 800 600 provide rich and intuitive information including the current working status of the device and various help information.
product brief introduction Product Introduction
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
Product description
This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc.
Technical index
Temperature control:
a. Chromatographic column chamber temperature
a.1 Temperature control range: room temperature +8 400(Set the temperature increment 1)
a.2 The precision of temperature control: It is±0.1, which is below 200;
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Product brief introduction Product Introduction
FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight-looking appearance Stability and other advantages.
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/q10); Small size and light weight with the same capacity large output capacity of the device and small power capacity required for configuration cheap convenient and safe operation.
2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown.
4ã??After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
1 monitoring functions output current instrument voltage null-reading cross pointer Closing indicator timing indicator
2 defensive function overcurrent protection timer
3 Adopt new time relay The timing range is much wider
4 Adopt new current relay more accurate more credible ensure personal and equipment safety
5 reasonably structured small in size in light weight
Product Introduction
TKJB - 1200 Six phase voltage and six phase current can be output, which has made it is possiable to be any combition, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out differential test of three-phase transformer
Product Characteristics
1 Meet all field test requirements.The Microcomputer relay protection tester is a standard of six phase current six phase voltage output at the same time the current a/phase 30 voltage125V/phase.Six - phase current in parallel up to 180A.It can not only test the traditional relays and protection devices but also test the modern microcomputer protection especially the transformer differential protection and backup self-switching device the test is more convenient and perfect.
2 All kinds of technical indexes have reached the standard of DL/ t624-1997 "technical conditions of microcomputer test equipment for relay protection" issued by the ministry of electric power.
3 Classic WindowsXP operation interface man-machine interface friendly easy and quick to operate;The high-performance embedded industrial control computer and 8.4-inch TFT true-color display with a resolution of 800-600 provide rich and intuitive information including the current working status of the device and various help information.
4 The native Windows XP system with recovery function to avoid illegal shutdown or misoperation caused by the system crash.
5 The device has an ultra-thin industrial The keyboard and a photoelectric mouse that handles everything just like a PC.
6 The main control board adopts DSP+FPGA structure and 16-bit DAC output which can generate high-density sinusoidal wave of 2000 points per week for the basic wave greatly improving the quality of waveform and improving the precision of tester.
7 High-fidelity linear power amplifier ensures the accuracy of small current and the stability of large current.
8 The Microcomputer relay protection tester with USB interface and PC communication directly without any connection easy to use.
9 Connect to laptop (optional) to run.Laptop computer and industrial computer use the same set of software no need to learn how to operate.
10 It is equipped with the independent auxiliary voltage source output the output voltage is 110V(1A) and 220V(0.6a) respectively.To be used by relays or protective devices that require dc working power.
11 With the function of software self-calibration it avoids the need to open
Product description:
standard current transformer is used as a standard for calibrating current transformers, Used as a standard to calibrate current transformer whose accuracy class is two or more lower than itself. The grounding pole of the machine shell must be grounded. To avoid electric shock, the conductor must be connected to the ground
Technical index
1. Temperature: -5-40
2. Relative humidity: 80%
3. Allow long-term work under the rated current; More than 600A across the core.
Feature;
1. The current of standard CT and tested CT must be the same in CT calibration.
2. Follow the given wiring diagram strictly.
3. Test whether the load box is accurate or not before calibrating the transformer.
4. Forbid secondary winding opening during the calibration.
5. Select demagnetization before calibration.Short out the secondary winding before cutting off the power when the demagnetization is finished.
6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Overview
In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy.
Technical parameter
range 0.910000
The accuracy of
reading 0.1 2 words or equal to 500
reading 0.2 2 words 500 3000
Reading 0.3 2 words 3000
The resolution of the
0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1
10 99.999 0.001 1000 9999.9 0.1
Working power supply AC220V 10 50Hz
Instrument weight 3.5kg
The use of temperature 10 50
Overall dimensions 260mm l 200mm W 160mmH
Relative humidity 90 no dew
Feature
Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision
Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function
Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known;
CT variable ratio polarity test function
Angle difference test function for single-phase test
Tap position can be tested up to 197
product brief introduction Product Introduction
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
product brief introduction
AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
Dc resistancetest around group is an indispensable test project of transformer after the submission of pick up overhaul and change of subpick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce work burden of test personnel, our company developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small size easy to use high measurement precision and good data repeatability. Measurement transformer is around the group and large power inductor dc resistance ideal equipment
product names Dc resistance tachometer Transformer dc resistance test instrument. Transformer winding dc resistance test instrument. Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance tester
Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.
Product name Transformer capacity test instrument transformer capacity load tester
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault.
After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent.
The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
product names Electric power transformer winding deformation test instrument Transformer winding deformation detector Transformer winding deformation meterTransformer winding deformation analyzer
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation.
Dc resistance around the group of measurement transformers is a very important test project. In the "test regulations of electric power equipment" its order ranks the second in the transformer test project. The "regulations" stipulates that pick up overhaul minor repair change sub-pick up head position fault check and pre-test etc. should be done in transformer. Measurement transformer must have dc resistance around the group whose purpose is:
(1) check the welding of line and lead line around the group;
(2) check if the pick up touch is good;
(3) check whether there is a broken place around the group or leading line;
(4) check the correctness of the parallel branch whether there is a few parallel guide lines winding into the winding group or a few broken line situation;
(5) check whether there is a short circuit between layers and turns.
The interface design of Dc resistance rapid test instrument adopts microcomputer control big screen backlit Chinese liquid crystal screen show operation is simple show clear man-machine interaction interface friendly measurement process and instrument work state prompt is clear and sufficient no operation personnel need to memorize too many procedures; Huatian electric power adopts current source line-based compensation technology with stable test high measurement precision and fast speed improving measurement efficiency and reducing work intensity of operation personnel. Technically "four-end" measurement is adopted to eliminate the measurement error caused by line resistance with pick up contact. Overvoltage protection function can resist electric potential impact. Panel printer can print measurement results quickly (selected). Small size light weight easy to carry.
Dc resistance rapid test instrument is applicable to measurement with analysis of various electric transformer transformer winding group and other perceptual low resistance.
product names Dc resistance tachometer Transformer dc resistance test instrument Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance rapid test instrument
Transformer dc resistance test instrument is an indispensable test project of Transformer after handing in pick up overhaul and change sub-pick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce the work burden of test personnel huatian electric power company developed Transformer dc resistance test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small volume easy to use high measurement precision and good data repeatability. Measurement transformer around the group and large power inductor dc resistance ideal equipment.
product namesï¼?Dc resistance tachometerã?? Transformer dc resistance test instrumentã?? Transformer winding dc resistance test instrument Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument
Product Introduction
The test system is mainly for power transformer distribution transformer no-load load characteristics; Dc resistance; Variable ratio group test also can be tested transformer power frequency withstand voltage test. At the same time external pick up ct interface is reserved for capacity increase.
Transformer comprehensive test station measurement part is controlled by single chip microcomputer and testdata such as digital display no-load and short circuit are sampled synchronously by single chip microcomputer avoiding errors caused by manual calculation of voltage ammeter and power meter readings respectively in traditional test methods.
product names Comprehensive test platform for transformer characteristics Transformer characteristic test station Transformer comprehensive test bed Transformer test station Transformer test bed Transformer comprehensive test station
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to the standard current ratio indicated on nameplate
This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling
Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63/(HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
Product description
The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage
Oil Immersed Testing Transformer 1
Technical index
Model
Capacity
High Frequency Voltage Output Voltage
High Frequency Voltage Output Current )
Low Frequency Voltage input
Change
Tempera- ture raised
30 minute
V
A
1.5
50
30
200
7.5
500
10
3
50
60
200
15
500
10
5
50
100
200
25
500
10
10
50
200
220/380
50/26
500
10
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
Product Introduction
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to standard current ratio indicated on nameplate
3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling
Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63 (HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
product brief introduction Product Introduction
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
Product nickname voltage transformer Calibration voltage transformer voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to the standard current ratio indicated on the nameplate
3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling
Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63/(HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
Product nickname, Precision voltage transformer, Calibration voltage transformer Calibrating voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight good-looking appearance Stability and other advantages.
Product nickname Transformer Load Box Voltage Transformer Load Box Current Transformer Load Box Voltage load box Current load box Voltage load box Current load box
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Pproduct brief introduction
AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to the standard current ratio indicated on the nameplate
3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling
Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63 /(HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates.
1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display.
2. With computer interface improve the level of office automation and reduce the labor intensity.
3. Can have a large screen display provide a friendly operation interface and rich measurement information.
4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box.
5. Possess good catching measures and be able to promptly inform users of wrong information.
6. This automatic transformer calibration station can reach level 2.
7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.
Product description
Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard
technical parameter
Temperature -5 40
Relative humidity 80%
Rated Primary Current 5-5000A 5A,1A
Rated secondary current 5A 1A
Accuracy Class 0.05S
Allow long-term work under the rated current; More than120A across the core.
Precautions
The current of standard CT and tested CT must be the same in CT calibration.
Follow the given wiring diagram strictly.
Test whether the load box is accurate or not before calibrating the transformer.
Forbid secondary winding opening during the calibration.
Select demagnetization before calibration.The wiring diagram is shown in figure 5.
Short out the secondary winding before cutting off the power when the demagnetization is finished.
Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product description
Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard
technical parameter
1. Temperature:
2. Relative humidity
3. Rated Primary Current:5-5000A 5A,1A
4.Rated secondary current:5 1A
5 Accuracy Class 0.05S
6. Allow long-term work under the rated current; More than120A across the core.
Precautions:
1. The current of standard CT and tested CT must be the same in CT calibration.
2. Follow the given wiring diagram strictly.
3. Test whether the load box is accurate or not before calibrating the transformer.
4. Forbid secondary winding opening during the calibration.
5. Select demagnetization before calibration.The wiring diagram is shown in figure 5.
Short out the secondary winding before cutting off the power when the demagnetization is finished.
6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Overview
Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer.
Technical parameter :
AC current output
Output accuracy
Phase current output (effective value)
Three merge current output (effective value) 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 900VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (fundamental) 20 1000Hz
Harmonics 1 20 times
AC voltage output
Output accuracy Level 0.2
Phase voltage output valid value 120V
Line voltage output valid value 210V
Maximum voltage output value 240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 20 1000Hz
Harmonics 1 20 times
Product Introduction
AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
xc control cabinet Technical Paramenters
environment temperature 0 40
altitude 100m
relative humidity 85%
Main product specifications
type specification capacity power source output operating mode Refer to the weight
anthroposcopy V A V A
XC-2 2 1 220 50 0-220 10 manual operation 14
XC-3 3 1 220 50 0-220 15 manual operation 16
XC-5 5 1 220 50 0-220 20 manual operation 18
Introduction
The SF6 gas comprehensive instrument is a three in one tester that integrates, concentration, and main crystallization measuring instruments. It concentrates the achievable capabilities into one and completes three functional tests at a time, which greatly reduces the gas emissions in the equipment and effectively protects the environment. , Pollution, while reducing the user's workload and improving work efficiency.
It is because the sensor of Finland Vaisala is used the SF6 gas comprehensive supplementary instrument has sufficient performance, and it uses an efficient absorption sensor.
The special instrument adopts the sensor of German HNP; some products adopt the special sensor of imported .
The SF6 integrated equipment display adopts a large screen Chinese display, real time various parameters, intelligent and intelligent operation, massive information, and dual use rechargeable batteries.
Energy saving technology, energy saving and environmentally friendly instruments.
The SF6 comprehensive tester adopts the sensor, sensor, SOH2S, CO and other sensors of Finland , and adopts the thermal conductivity type of
Sensors and R&D sensors; more advanced ARM development technology, quality sensors, sensors and other precision sensors, equipped with sensors and sensors are more realistic, more simultaneous, and manufactured. The tester uses a color screen screen display, friendly interface, and easy to operate.
This type of comprehensive tester uses reliable imported sensors as sensitive components, and at the same time integrates real time measurement, curve display, power management, time system, file system, data query, data understanding and other update functions, and integrates advanced sensor technology. And information technology, humanized operation information technology, humanized operation and perfect functions, you can learn her ability and perfection in printing.
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture.
Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues.
Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection device TCD.
Chromatographic instrument using microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrument large screen liquid crystal display. The detection apparatus and its control assembly unit adopt plug and play control model simplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motion temperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations.
The detector adopts the unitized combination design which is easy to install and maintain. The chromatography can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time.
The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
Product nickname hydrogen generator full-automatic hydrogen generator self-motionHydrogen generator chromatographic instrument
Application:
TKQC type SF6 gas recovery device is an integrated recovery device. The device is composed of a recovery system a vacuum pumping system a cleaning system a storage system and a condensing system.
Features:
Adopt advanced principles and technology advanced design complete function reasonable structure simple operation.
Two-stage rotary vane vacuum pump the vacuum speed is fast and equiped with anti oil return device.
Automatically confirm and adjust the three phase power supply for electrical system.
Using the newest patented technology SF6 special instrument and valves more reliable than similar products.
The device adopts air cooling movable type and can be used without external water source.
Product Introduction
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture.
Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues.
Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection deviceï¼?TCDï¼?.
Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal displayï¼?The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations.
The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time.
The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
Product description
Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V 50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots gloves withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.
A special water tank can be customized according to needs to test 68 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots gloves
Product Introduction
Insulation boot (glove) withstand voltage test device is designed and manufactured by our company according to the test procedure of gloves (insulated boots) and in accordance with the opinions of users. This product effectively solves the irregular test methods in the past which simplifies the testing procedures and improves the testing speed. More reliable identification of gloves (insulated boots) leakage current insulation aging power frequency withstand voltage and other parameters. It is the ideal equipment for gloves (insulated boots). Its main features: It can test 3 pairs of gloves (insulated boots) at the same time and can read each leakage circuit to accurately judge the unqualified gloves (insulated boots); the bottom of the structure can be moved freely.
product features Product Characteristics
1 Insulation boot (glove) withstand voltage test device effectively solved the past irregular test
2 improve work efficiency ensure work safety is an ideal special equipment for insulated boots (gloves)
Product Introduction
Insulation boot (glove) withstand voltage is designed and manufactured by our company according to the test procedure of insulated boots (gloves) and in accordance with the opinions of users. Insulation boot (glove) withstand voltage uses automatic (lower) voltage to automatically read out the leakage current of each test item. The whole test process is completed automatically and the test data is automatically printed which effectively solves the irregular test method in the past. This simplifies the testing procedures and improves the testing speed. More reliable identification of the leakage current of the insulated boots (gloves) power frequency withstand voltage and other parameters. It is the ideal equipment for insulating boots (gloves) to ensure the safety of test workers. Its main features: test 6 test items at the same time and read the leakage current of each test item to accurately judge the unqualified test items; the test vehicle is equipped with casters at the bottom for easy movement using a large white light display under strong light Still clearly visible with a one-click shuttle easy to operate with a good interactive experience.
1 automatic and fast: the use of high-fine stepper motor to control the voltage regulator boost process according to the national standard test parameters fully automatic pressure test. After the test starts the instrument automatically closes and automatically boosts the boosting speed according to the national standard. It reaches the scheduled voltage and starts to count and keeps the test voltage. It automatically depressurizes the timer until the preset time. After zero the power is automatically turned off indicating that the test is over. Display each sample leak Current and display the test result
2 full-featured: full Chinese interface work status display simple and clear operation wide application; with status display with reminder function the user can see the status of the device at a glance; rotate the mouse operation all functions can be rotated by one Mouse setting all digital adjustment abandoned the old potentiometer adjustment mode the field is very convenient to use; button directly set the target Voltage leakage Current pressure time application freely
3 intelligent security protection: with Current over the protection of the Voltage. Accurate and fast protection ensuring the safety of personnel and equipment
4 output Voltage large measurement is convenient and flexible: the device can customize the output of any voltage of 1-30kV the leakage Current threshold can be set arbitrarily 1-20mA the test time can be arbitrarily set 1-10min and the common insulation equipment parameters are in accordance with the national standard. Integrated synthesis module easy and quick to test
5 friendly man-machine interface: white light large screen 320*240 dot matrix Chinese character graphic interface clear and beautiful writing; can be clearly visible under strong light using high-performance rotating mouse easy to operate long life; comes with high-speed micro printer instant print test data
Overview
The electric red line external thermometer can determine the surface temperature by measuring the infrared energy radiated by the target surface, and the power infrared thermometer low-power design ensures that the product can work longer. Electrical infrared thermometer intelligent design helps users more easily test, more quickly capture the true value of the object being measured, and the meter can intelligently select the battery or USB connection. The surface temperature can be determined by measuring the infrared energy radiated by the target surface.
The electric red line external thermometer is a tool for detecting internal structural fault detection of the power transformer, which can determine the surface temperature by measuring the infrared energy radiated by the target surface, widely used in electric power, electronics and cast, architecture, energy, smelting, petrochemical , Railways, cars and other industries. The infrared thermometer is designed with low-power intelligence. It is capable of intelligently selecting a battery or USB connection. The low-power design ensures that the product can work for a long time, reducing the user's troubles. The infrared thermometer helps users easily test, quickly capture the true value of the object to be measured.
Technical parameter:
Measuring range 50 1050 (-58 1992)
Spectrum range 8 14um
Infrared temperature precision ± 1.8% or 1.8 C (4 F)
T-C temperature measurement accuracy ± 1% or 1 C (2 F) (assuming the environmental working temperature is 23 to 25 C (73 to 77 F) 0 C below the original foundation + 1 C, - 35 C or less only for reference)
Repeatability ± 0.5 C or ± 0.5% reading
Response time (95% s) 250ms
Transmission rate adjustment 0.101.00
display resolution 0.1C (0.1 F) (0.2 C in less than 10 C; 1 C / 1 F greater than 999.9)
Secondary display information Maximum, minimum, difference, mean
laser
Aiming Single point laser
Power Level 2 (ii) operation; output
Overview
The electric red line external thermometer can determine the surface temperature by measuring the infrared energy radiated by the target surface, and the power infrared thermometer low-power design ensures that the product can work longer. Electrical infrared thermometer intelligent design helps users more easily test, more quickly capture the true value of the object being measured, and the meter can intelligently select the battery or USB connection. The surface temperature can be determined by measuring the infrared energy radiated by the target surface.
The electric red line external thermometer is a tool for detecting internal structural fault detection of the power transformer, which can determine the surface temperature by measuring the infrared energy radiated by the target surface, widely used in electric power, electronics and cast, architecture, energy, smelting, petrochemical , Railways, cars and other industries. The infrared thermometer is designed with low-power intelligence. It is capable of intelligently selecting a battery or USB connection. The low-power design ensures that the product can work for a long time, reducing the user's troubles. The infrared thermometer helps users easily test, quickly capture the true value of the object to be measured.
Technical parameter:
Product Introduction
It is suitable for evaluating the insulation quality of high voltage transformergenenratorling-distance power cable and busbar under strong interference in the field of high-voltage substation and power plant.Specially used for 110KV and above large capacity transformer and long distance power cable power system
Product Characteristics
1.Strict accordance with the safety standards for design with 5 range: 500V 1000V 2500V 5000V 10000V test up to 10T�©.
2.This instrument has the function of automatic calibration and calibrate precision automatly before test
3.Actual test object live voltage measurement functionmeasure leakage currentdischarge automatly.
4.automatic measure and remenber R15Sã??R60S ã??R10min valueAutomatic display polarization index (PI) induced electric absorption test values than (DAR)and test time.
5.Anti-jamming performance is superior the interference current reaches 600 mA still ensure accuracy of test instruments.
6.Automatic discharge:quickly discharge for capacitive test object by advanced high-voltage discharge technology and real-time measurement of discharge voltage (test voltage to 0v) .
7.powered by internal rechargeable lithium battery or ac power supply the real ac and dc dual use does not affect the test accuracy.
8.digital displayautomatic display battery level and undervoltage alarm protection function.
9.Short circuit protection short circuit condition will not burn out the instrument
Transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The acid value is the trace value of potassium sulfate that neutralizes the petroleum acid in 1g of oil, which contains a certain amount of inorganic acid and inorganic acid. The acid value includes organic and inorganic acids contained in the oil. In most cases, oil does not contain mineral acids. Therefore, the oleic acid value actually represents the content of organic acids in the oil. The organic acid contained in the new oil is mainly cyclonic acid. In the oil and in the process of use, the acid value of the oil produced by oxidation is an indicator to measure the degree of refining of the new oil. Whether the oil is running is an important indicator of the continued use of oil quality equipment.
2. Technical index:
1.Test range: 0.002 1mg KOH/g
2.Test error: 0.005mg KOH/g
3.Repeatability: 0.005mg KOH/g
4.Ambient temperature: 10 45
5.Relative humidity(RH): 85%RH
6.Voltage supply: AC220V/50Hz
7.Power: 50W
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables.
1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use.
2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
Product Introduction
Designed for automatic testing of protective and metrological CT/PT suitable for laboratory and field testing.
The product namesï¼?PT volt-ampere characteristic tester transformer volt-ampere characteristic integrated tester CT voltage-current characteristic integrated tester CT voltage-current characteristic tester PT volt-ampere characteristic tester transformer volt-ampere characteristic tester volt-ampere characteristics of variable polarity than integrated tester volt-ampere characteristic tester volt-ampere characteristics integrated tester volt-ampere characteristic tester features comprehensive tester
Product Introduction
WFLC-VI Portable Waveform Recorder is a portable device based on the structure of an industrial portable computer. It takes high-performance DSP high-precision ADC chip and embedded operating system as hardware and software architecture and integrates data acquisition processing transmission storage analysis and other functions as one.
DSP acquisition chip for data acquisition and calculation so as to achieve full digital analog signal filtering flexible and diverse sampling frequency from 10K /s 20K /s 50k/s 100K /s can be selected by users can be used for transient electrical signal waveform recording and analysis.
With advanced industrial control kernel and embedded operating system users can easily carry out data storage backup analysis output and other operationsã??
WFLC-VI portable waveform recorder is a collection of fault wave record generator characteristic test and other functions in the integration of intelligent instrument with its small size strong function scope of application is wide flexible configuration and many other advantages favored by the masses of users is a power utility workers standing it will be for the electric power industry production and technological progress to make due contributions.
Product description
This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc.
Technical index
Temperature control
Chromatographic column chamber temperature
1 Temperature control range: room temperature (Set the temperature increment 1)
2 The precision of temperature control: It is0.1, which is below 200
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.
Technical index
Oil cup technical specifciations:
Distance between High Voltage terminal
and Low Voltage terminal 2mm
Capacitance of Empty Cup 602PF
The Highest testing voltage Industrial Frequency 2000V
Dielectric Loss of Empty Cup tg1 10-4
Liquid capacity About 40ml
Electrode Material Stainless Steel
Volume 70mm(D) 120mm
1
Condition of Uss
2
Power Source
AC 110V10% Without Frequency Limit
3
AC High Voltage Output
4
DC High Voltage Output
Temperature Control Induction Stove
Maximal Power 500W
6
Temperature Control Range
Product description
Automatic tension tester Intermolecular Forces formed liquid surface tension.Numbers of tension reflect on liquid sample s physics and chemical properties, it is one of the most important index to product quality. automatic interfacial tension tester apply to GB/T6541,it can test kinds of liquid surface tension and boundary surface tesion.this method sample and accuracy,so it s used widely.
Specifications
Product Introduction
YDW series PD tester system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities.
product features Product Characteristics
A variety of control methods and insulation methods can be used to configure freely according to user demand.
â??Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi- frequency power generator which can be used to measure the discharge of high voltage transformer.
Manual control operation is intuitive easy to use maintenance low price.
It has gas insulation transformer oil insulation dry epoxy resin insulation and other forms test transformer can choose and match according to user's demand.
According to the user's requirements different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults.
Automatic control system can be used in different configurations of the bureau and the results can be automatically detected and analyzed.
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Characteristics
1ã??Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;
2ã??Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3ã??The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;
4ã??After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
1 The output voltage is stable: the high-frequency voltage doubler circuit is applied and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate so that the voltage stability is high and the ripple is small.
2 comprehensive protection: full protection function with zero protection over-voltage protection over-current protection breakdown protection protection circuit uses nanosecond-level special sensor action fast and reliable effectively protect personal and equipment safety.
3 0.75U function: Add intelligent high-precision 0.75U function one-button button press this button the voltage and current will automatically jump to the 0.75U state which is conducive to the test of zinc oxide arrester.
4ã??zero boost: The boost potentiometer starts from zero adopts imported multi-turn potentiometer the boosting process is stable and the adjustment precision is high.
5 over-voltage setting: over-voltage setting uses digital dialing switch easy to operate and has a high setting accuracy.
6 one-piece design: the choice of integrated design Host and double pressure cylinder is placed in a chassis. The imported high-frequency high-voltage rectifier diode is used to make the double-pressure cylinder small in size improve the efficiency of the whole machine and is easy to carry.
7 reliable performance: the key components use high-performance imported components the pressure roller is coated with special insulating materials good electrical performance strong moisture resistance no leakage.
8 the operation is simple: the instrument interface each function button the layout is reasonable the instructions are clear easy to learn and use.
1 This product is composed of large current generator voltage regulator temperature tester industrial controlling computer operation system.
2 Voltage and current displayed by industrial controlling computer software precision level is 0.5.
3 With zero position starting up protection function and emergency stop function.
4 Software test time self setting and with prompting function.
5 After current setting any deviation software can automatically adjust according to the parameters set in advance.
6 Prevent strong magnetic interference.
7 Use imported K type thermocouple: 0~1370
8 Temperature tester with multi channel temperature monitoring measuring recording function and comparing with the test point temperature formrising temperature self alarm when the rising temperature higher than setting temperature. Any point temperatures and temperature rising value can be checked measurement error is �±1%.
9 Adopt anti interference technology combined with the hardware and software function is stable and anti-interference is strong. Four basic screens digital display picture bar chart display picture real time curve picture recall curve picture.
TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches.
Features
1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes.
2. Need not disassemble the vacuum switch during the field test.
3. High precision.
4. With LCD easy to operate.
5. Can save print and review the test results.
6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life.
7. Light in weight easy to carry.
Product Parameters
Alternating current source
SMG7000 Handheld Power Quality Analyzer Accuracy
1. Electric parameter measurement part: Voltage: ± 0.2% Frequency: ± 0.01Hz
Current power: ± 0.5% Phase: ± 0.2
2. Power quality parts: Fundamental voltage permissible error 0.5%F.S.
Fundamental current allowable error:1%F.S.
3. Fundamental error of measurement of phase differencebetween voltage and current: 0.2
4. Harmonic voltage rate measurement error: 0.1%
5. Contain measurement error of harmonic current: 0.2%
6. Three-phase voltage unbalance error: 0.2%
7. Voltage deviation error: 0.2%
8. Voltage tolerance: 0.2%
working temperature:-10 ~ + 40 power supply: AC220V frequency 45Hz-55Hz
power consumption: 3VA battery operating time: less than 10 hours insulation:
1) input voltage and current on the chassis of theinsulation resistance: 100M Max.
2) power input terminals for shell under industrialfrequency 1.5KV (RMS) a 1-minute experiment.
9. Volume: 320mmx240mmx130mm
10. Weight: 2.0Kg
In the preventive insulation test of power equipment it is required to measure the insulation oil parameters of power equipment periodically. The measurement of dielectric loss and resistivity of insulating oil is one of the most important. For a long time most of them adopt the bridge method for measurement which is complicated in operation and the measurement accuracy is affected by many factors thus leading to a large measurement error. With the rapid development of electronic technology and the power industry for small volume light weight easy to operate rapid measurement high precision measurement instrument requirements I refer to domestic and foreign related instruments developed in the domestic leading insulation oil dielectric loss factor and dc resistivity tester. The instrument is designed and manufactured according to gb5654-2007 and related standards. It is controlled by microcomputer easy to use high measurement accuracy high test efficiency and greatly reduces labor intensity.
Dielectric strength tester for insulation oil is my company all the scientific and technical personnel according to national standard GB507-86 line and the DL - 474-4-92 the relevant provisions of the DL/T596-1996 play their own advantages after a lot of field test and long-term unremitting efforts carefully research and development of high accuracy fully digital industrial equipment.Dielectric strength tester for insulation oil as a simple modelling is beautiful and easy.Due to the use of automatic digital microcomputer control so high measurement accuracy strong anti-interference ability safe and reliable.
Product names Oil tester insulation oil pressure tester dielectric strength tester automatic insulating oil dielectric tester insulation oil pressure automatic tester automatic insulation oil pressure tester microcomputer automatic insulating oil tester automatic test machine fully automatic testing device portable oil pressure test device the electric strength tester Dielectric strength tester for insulation oil
In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB/ t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL/ t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China.
DC system grounding fault tester is a new generation of tester. It can be applied to dc systems of any voltage grade. It is equipped with high-precision detection clamp table which greatly improves the detection range and anti-interference ability through efficient processing of multiple signals. Advanced algorithm and fuzzy control theory are adopted to express the superiority degree of detected insulation branch in numerical form which fully reflects the superiority of artificial intelligence. They have accurate judgment on the location of the grounding point and can point out the location and direction of the grounding point every time.
DC system grounding fault tester takes system safety as the primary premise conducts detection in a reliable low-frequency signal in strict accordance with the requirements of industry standards and carries out a large number of practical applications in the field without any impact on the system.
Dc systems in power plants and substations provide power supply for control protection signals and automatic devices. The safe and continuous operation of dc systems is of great importance to ensure power supply and distribution. As the dc system is not grounded by floating system if two-point grounding occurs it may cause the above devices to misoperate and refuse to operate thus causing a major accident. Therefore when one point grounding occurs the grounding point should be accurately and quickly detected while ensuring the normal power supply of the dc system to eliminate the grounding fault so as to avoid the possible harm of two points grounding.
DC system grounding fault tester is used to find the exact location of DC system grounding points of power plants and substations in the case of constant electricity. All kinds of grounding faults can be found out quickly with good accuracy.
Product nickname: DC Ground Fault Tester DC System Fa
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation
1) AC/DC analog value input measurement
2) state variables input measurement
3) remote control execution testing
4) remote regulation function testing
5) digital value input testing
6) impulse input testing
2. AC Power source
It can output AC voltage AC current
accuracy 0.05 class
can provide standards of AC/DC voltage/current power phase power factor frequency energy.
Output method and output electric quantity can be set arbitrarily
3. Data management
It can save search browse print or delete RTU testing data.
Calibrated parameters can be saved permanently
Product description
Partial discharge inspection instrument is a digital partial discharge charged detection instrument designed by our company based on years of experience in partial discharge measurement. It adopts two emerging technologies, ultra high frequency (UHF) measurement and ultrasonic (US) measurement. This system uses modern electronic and computer integrated technology to realize signal amplification, filtering, data acquisition, data processing, partial discharge parameter calculation, map drawing, and automatic generation of test reports, thereby completing the intelligent measurement and analysis of partial discharge. This device adopts handheld design and Wince system development; the device is lightweight, convenient to carry, fast to measure, and easy to use on the spot; it has friendly interface, simple operation, and high refresh rate; and the device has complete functions, strong anti-interference ability, and accurate measurement. This instrument has no damage to the power equipment to be tested during the testing process, and has no impact on the operation of the equipment. According to the maps obtained by the multiple detection modes of the UHF and US methods, the diagnostic analysis of the detection of insulation defects or hidden dangers of power equipment can be performed to clearly determine the operating status of the power equipment.
Technical index
Host parameters
Number of interfaces
2 interfaces 1 UHF interface 1 US interface
Sampling accuracy
12bit
Way of synchronization
Internal synchronization,External synchronization,
Light synchronization
UHF parameters
Measurement frequency range
300MHz-1.5GHz
Output method
Output with SMA head
Receiving method
Receive with antenna
Transfer method
Coaxial cable
Sensitivity
70dB
Mean sensitivity
50dB
Dynamic Range
80dB
Hardware
Display screen
4.3 TFT true color LCD screen
Resolution
480 272
Product description
Partial discharge comprehensive analyzer is the dedicated product to measure and analyze the insulation ability of electrical equipment. This system adopts modern electronic and computer integrated technology with the functions of signal amplification(analog signal, electronic signal, digital signal), filtration, data sampling, data processing, figure display, test report generation automatically so that it may finish the measurement, location and analysis of the partial discharge.
Technical index
Technical characteristics
Number of interfaces
Free-running 4 interfaces
Sampling rate
1M. 5M. 10M selected
Sampling accuracy
12bit
Range changing
-40dB, -20dB, 0dB, 20dB, 40dB ,60dB, totally 6 types
Measurement frequency range
3db bandwidth 10kHz 1MHz
Digital filtering
10kHz 1MHz freely selected
Program controlled filter subsection
Nonlinear error in the range
10%
Measurement range
0.1pC~100,000pC
Sensibility
0.1pC
Capacity range of the measured product
6pF 250 F
Frequency range of test power
50 500Hz
Display
Display screen
12 TFT true color touchable LCD screen
Resolution
1024 768
Interface
USB
3 types, use of external mouse, keyboard or other USB devices.
Power mode
AC 220V; Frequency 50Hz; Power 300W
Electric signal interface
4 BNC interfaces, use of signal input.
Optical signal interface
4 types, use of signal input
Network interface
1 type
Landing button
External landing
General instruction
CPU
Basic frequency 1.60GHz
Ram
2.0GB
Hard disk
128GB SSD
System
Windows Xp
Operating environment
Size
Weight
15.8kg
The hand-held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.
Technical parameter
Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01A;
The AC current is in the range of 10A-100kA, error: no more than 0.03%.
Current resolution: current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V;
The AC voltage is within 100V-1000kV range, error: no more than 0.03%.
Current resolution: current is 0.001V in the range of 0V-1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;
2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;
4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
Overview
The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user communication in and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.
Technical parameter
Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A10A, error no more than 0.01A;
The AC current is in the range of 10A-100kA, error: no more than 0.03
Current resolution current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V
The AC voltage is within 100V-1000kV range, error no more than 0.03
Current resolution: current is 0.001V in the range of 0V1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0 359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
GOOSE input and output function
The tester is really ready for the Goose output function, supports the output of 60 GOOSE control blocks, and the output message is required to meet the needs of the configuration file. The output message data type can support single point, double point, floating point type
The tester has a Goose reception function, and the analysis of multiple Goose block messages can be performed. The statistics include channel variations, and displacement channel information.
Overview
Gas vacuum device is suitable for various power supply companies, substation of substation transmission, power plant, ultra high voltage transmission and power plant and other power plants, ultra high voltage transmission power stations, SF6 electrical switch manufacturing factories, etc., as SF6 electrical products such as GCBP, GCBT , GIS, installation, modulation, and overhaul essence.
With the rapid development of the power industry, the infrastructure of the power industry, especially the continuous increase in SF6 electrical equipment, the SF6 electrical equipment is installed, maintenance and maintenance.It is getting higher and higher, and the relevant departments have higher quality and time requirements for the vacuum and return ingredients in the SF6 electrical equipment especially the GIS construction and overhaul. In order to adapt to this development, the company has been engaged in SF6 gas electrical equipment test, detection and professional technical experience accumulation. According to the analysis of foreign advanced maintenance equipment, the technical indicator requirements of foreign advanced equipment have been developed. Further, it can meet the products of domestic users SF6 gas vacuum device
Technical parameter:
Vacuum pump rate L S 4
Extreme vacuum PA 6 10 2
Vacuum time m 30L 60L 180L 300L 600L 1200L
8 16 48 80 160 320
Outer 550cm 300cm 1200cm length width height
weight 40kg
Operating Voltage 380 460V 50Hz AC electricity
Noise level 62dBA
Vacuum rate customizable
Recovery rate customizable
Extreme vacuum 10Pa
Leak rate 0.5
Conveyor 5 meters
tire High quality casters, easy to move, do not harm
Vacuum table Pointer or digital optional
Voltage 380V 50Hz
OVERVIEW
Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB T507-2002, industry standard DL429.9 91 and the latest Electric Power Industry Standard DL T846.7-2004 by ourselves. This instrument, by using a single chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.
MAJOR TECHNICAL INDICATORS
Output voltage 0 100KV optional
Voltage distortion rate 3
Voltage raising speed 0.5 5 KVS adjustable
Standing time 15min adjustable
Boosting interval 5 min adjustable
Boosting frequency 1 9 time s optional
Booster capacity 1.5KVA
Measuring accuracy 3
Supply voltage AC220V 10
50Hz1 Hz
Power 200W
Applicable temperature 0 45
Applicable humidity 75 RH
Overall dimension 465 385 425
Transformer Oil Dielectric Strength Tester 2
Overview
Gas vacuum device is suitable for various power supply companies, substation of substation transmission, power plant, ultra high voltage transmission and power plant and other power plants, ultra high voltage transmission power stations, SF6 electrical switch manufacturing factories, etc., as SF6 electrical products (such as GCBP, GCBT) , GIS, installation, modulation, and overhaul essence.
With the rapid development of the power industry, the infrastructure of the power industry, especially the continuous increase in SF6 electrical equipment, the SF6 electrical equipment is installed, maintenance and maintenance.It is getting higher and higher, and the relevant departments have higher quality and time requirements for the vacuum and return ingredients in the SF6 electrical equipment (especially the GIS) construction and overhaul. In order to adapt to this development, the company has been engaged in SF6 gas electrical equipment test, detection and professional technical experience accumulation. According to the analysis of foreign advanced maintenance equipment, the technical indicator requirements of foreign advanced equipment have been developed. Further, it can meet the products of domestic users SF6 gas vacuum device
Technical parameter:
Vacuum pump rate (L / S) 4
Extreme vacuum (PA) 6 10-2
Vacuum time (m) 30L 60L 180L 300L 600L 1200L
8 16 48 80 160 320
Outer 550cm height)
weight 40kg
Operating Voltage 380 460V 50Hz AC electricity
Noise level 62dB(A)
Vacuum rate customizable
Recovery rate customizable
Extreme vacuum 10Pa
Leak rate 0.5%
Conveyor 5 meters
tire High quality casters, easy to move, do not harm
Vacuum table Pointer or digital (optional)
Voltage 380V 50Hz
Function
1. Electronic vacuum display (other vacuum tables can be configured according to user requirements);
2. Equipped with various types of imports, domestic SF6 electrical equipment connection connector (optional);
3. Automatically vacuum (optional) according to the time or vacuum set by the user.
4. A variety of protection functions, effectively guarantee the safe operation of the vacuum pump;
5. Easy to maintain, the vacuum inflatable device has adopted a good performance, and it is not necessary to repair for a long time.
In the power system and factories mines enterprises have a large number of oil filling equipment. The flash point of insulating oil is a routine test item that must be measured. KKY open flash point tester is a replacement of the current open flash point tester for petroleum products. This instrument is based on the national standard GB/ t3536-2008 which requires the determination of samples. The whole determination process is carried out automatically. The instrument adopts the super large screen liquid crystal display the determination is accurate the performance is stable can completely satisfy the petroleum chemical industry the electric power the scientific research and so on department determination petroleum product open flash point need the use is very convenient deeply the majority of oil workers welcome.
Product Introduction
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
Product Characteristics
1. With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
2. The short-circuit current of test power> 5mA, maximum up to 15mA. Be suitable for testing high capacity and high inductance.
3. Wide resistance range from 0.5M�© ~ 200000M�©. With high-resolution, having accurate readings.
4. Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV, you can smoothly adjust voltage from 0V to the desired value.
5. With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.
Product Introduction
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price performance ratio.
The high tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
We have more than 30 years of production experience recently launched a new generation of automatic intelligent leak detector.It is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users.At the same time we apply our rich technology and experience to this product so that users can enjoy excellent performance and price ratio.
The high-tech central microprocessing unit is the core of sf6 gas qualitative leak detector. Its digital signal processing ability can better manage the circuit and process the detection signal. Due to the large number of integrated circuits the number of components in the circuit is reduced by 40% which greatly improves the reliability and efficiency. The microprocessor can monitor the probe and battery voltage at the rate of 4000 times per second. Even the tiniest signal can be captured. It can work stably and reliably in any environment.
The sf6 gas qualitative leak detector has added some convenient functions. The seven-level sensitivity increases the sensitivity by 64 times. The three-color leds indicate the degree of leakage in a wide range in a progressive manner and are also used to display sensitivity levels and battery power.Touch keyboard for all operations. Avant-garde long and thin shape design greatly facilitates users to use and maintain. It is very convenient to use the indicator light in the direct range.
Description
Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor Power generator No load test, Short circuit test, Motor excitation step response test, motor excitatory de excitation test, motor load rejection test and grid synchronous connection test and also on
Technique index
There are 12channels voltage current sample. The analog range include 10V10V, 200V 200V, 400V 400V and 20mA 20mA. Users can switch the input range from software. Also there is one channel 100mV 100mV which allow the input signal less than 10V.
The voltage and current input range assured errors are as follow
400V 400V assured error less than 0.5V
200V 200V assured error less than 0.2V
10V 10V assured error less than 0.01V
20mA 20mA assured error less than 0.02m
100mV 100mV assured error less than 0.2mV
There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V.
There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V 1A.
There are 2 USB port used for data export and mouse keyboard input
The LCD is 12.1 inches touch pad input mode. Make the human interface more simple.
The saved space in the tester is 32G for standard configuration
Input resistances for different channels are as follow
10V 10V Range Input resistance is 820K
200V 200V Range Input resistance is 820K
400V 400V Range Input resistance is 820K
20mA 20mA Range Input resistance is 820K
100mV 100mV Range Input resistance is 10M
Power supply AC 220V 10 45Hz-65Hz
Overview
High pressure wireless phase detector is a dedicated test high-voltage nuclear phase tester based on national power industry standard norms and market demand, and high-voltage nuclear photographic applies to detecting the two-sided circuit breaker of the ring or dual power supply power network closed loop circuit breaker. Whether it is produced in the same phase.
Before the closed loop two power supply, you must perform a nuclear phase, otherwise a short circuit can occur, suitable for the 6KV ~ 220KV transmission line with the electrical core, the sight can reach 200 meters, and the wall can be used, and it has a test function.
Wireless high-pressure cores use wireless transmission technology, safe and reliable operation, easy to use, in line with national electric power safety equipment quality supervision and testing standards. Compared with the cable core, it is the main advantage that the lead wire connected to both grids (power supply) is removed, and the safety is used to improve the security in a manner that is not subject to any terrain and facility architecture.
Technical parameter:
Phase difference
Error 5
Frequency accuracy 0.1Hz
The voltage grade measured by this product is 6kv-220kv
Transmission distance of the transmitter and receiving host
Product Introduction
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506-2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Technical Parameters
Measuring range Dew point value 80 20
Moisture content 19999uL L
Accuracy of measurement 0.5 60 20
1.0 80 60
The resolution of the Dew point value 0.1
Moisture content 1uL L
Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20
63 needs 10s 90 needs 240s 20 60
Sampling flow 0.6L min 20
Pressure range 1.0Mpa
The use of temperature 20 60
Environmental humidity 100 RH
Storage temperature 20 80
Charging time 4 hours
The whole machine size 250 150 300mm3
The weight of The machine 3.5kg
product description
Oil trace moisture tester This instrument is able to work more reliably and conveniently by using the most advanced control circuit and 32 bit embedded microcontroller processor as the master control core and utilizing embedded mini operating system.
Oil trace moisture tester 2
Technical index
Titration method Coulometric titration Coulomb analysis
Display Color LCD touch screen
Electrolytic current control 400mA automatic control
Measurement scope 3ug 100mg
Sensitive valve 0.1 µg H2O
Accuracy 10 µg 1000 3 µg
More than 1mg but not greater than 0.3
Printer Miniature thermal printer
Power supply 220V 10 50Hz
Power 40W
Ambient temperature 5 40
Ambient humidity 85
External dimension 340 295 155
Weight About 5.5kg
Product description
120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard Generation Requirement of Portable HVDC Generator ZGF 24003 90
Technique Index
power AC220V 10, 50Hz 1
Output voltage indicator accuracy
Overview
The power infrared thermal imaging is used for on-site temperature detection, electric prophylactic maintenance. Electricity infrared thermal imaging standard support: ZBY097-1994, power infrared thermal imaging adopts UFPA non-refrigeration flat infrared detector and high quality optical lens as the core.
The heat imager uses the UFPA non-cool focal plane infrared detector and optical lens as the core. It combines the convenient and quick operating system, leading the horizontal ergonomic structure design, and has a perfect development of accessories. It has created a clear, Ideal temperature measuring tool for accurate, simple operation, and lightness, the infrared thermal imaging device | heat imaging instrument measuring temperature 20 C to 300 C (expandable to 1500 C) is on-site detection, prophylactic maintenance and other applications Operation selection. The TK660A infrared thermal imaging can be widely used in electricity, electronics and buildings, energy, smelting, petrochemical, railways, automotive and other industries.
Technical parameter:
Resolution 160 120 pixels
Thermal sensitivity 0.08 C 30 C
Measuring accuracy 0.2% 2 words (full range)
Spatial resolution 2.2mRad
Focus method Manual focus
Palette Six types (iron red / anti-iron red / color red / feather / white hot / black hot)
Work band 8-14um
Temperature range -20 C to + 300 C (expandable to 1500 C)
Temperature measurement accuracy 2% or 2 C (the maximum value is taken)
Working temperature -15 C to 50 C
Storage ambient temperature 40 C to + 70 C
Humidity -95% RH (non-condensation)
Power Adapter 8V-11V DC output
Total Weight
Product Introduction
Digital PD Detector Partial Discharge Testing
Digital PD Detector Partial Discharge Testing Product Overview
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method).
Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy.
product features Product Characteristics
Digital PD Detector Partial Discharge Testing Working Condition
Altitude 3000m
Environmental Temperature -20~60C
Relative Humidity 95%
SMG6600 six channel differential protection vector tester is a kind of instrument which can measure primary side current secondary side current and secondary side voltage at the same time and then make analysis and report. The instrument can analyze three-phase unbalance degree and hexagonal vector diagram by measuring primary side current secondary side current and secondary side voltage and can output word and Excel files without upper computer software which is convenient for users Period processing report.
The instrument adopts high-precision data acquisition chip with analog 24 bit ADC precision DSP processing data arm and TFT touch screen display measurement data intuitively and conveniently.
1. At the same time measure the 1-3 AC voltage on the secondary side;
2. At the same time measure 1 to 3 AC currents on the primary side;
3. At the same time measure 1-3 AC current at secondary side;
4. Measure the phase between voltage current and voltage (angle between primary and secondary current);
5. Measurement of power grid frequency;
Measurement of active and reactive power;
7. Measurement of power factor;
8. Three phase voltage and current unbalance detection;
9. Secondary side phase voltage range: 1-500v secondary side current range: 1ma-10a primary side current: 100ma-5a;
10. Display hexagonal vector diagram (mixed primary side and secondary side);
11. It is used as leakage current meter;
12. Low power consumption design built-in rechargeable battery as backup power supply;
13. Automatic range user-friendly design of mouse operation;
14. Data storage can be exported through U disk which is convenient for user data processing;
15. The field measured data can be printed out by micro printer;
16. Export files in word and excel format to facilitate printing reports.
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
TKHG-Q current transformer field calibrator was developed based on high-end testing technology large-scale electronic circuit design and in compliance with relevant national regulations. It solves the problems of on-site verification of current transformer and voltage transformer with high working intensity and tedious operation. At the same time the product has reliable performance and powerful functions.
1. The instrument also has a recursive method to measure the current transformer error which is convenient for the on-site verification of the measurement device.
2. On-site verification of current transformers does not require standard current transformers current risers load boxes voltage control boxes and high-current conductors. It uses extremely simple test wiring and operations to achieve the verification of current transformers greatly reducing the work The intensity and working efficiency are improved which is convenient for the on-site verification of transformers.
3. The instrument has a standard voltage transformer equivalent to the same transformation ratio of the measured current transformer. Its accuracy can reach 0.05 level and the transformation ratio and no-load error of the measured current transformer can be accurately measured. Then combine the test results of impedance and admittance to calculate the error of the transformer.
4. Adopt different frequency power supply test close to power frequency to prevent on-site power frequency electromagnetic radiation and series interference.
5. Wide measuring range can reach 5A / 5A ~ 25000A / 5A or 5A / 1A ~ 6300A / 1A.
product brief introduction Product Introduction
Intelligent instrument calibrator for PT CT error and impedance admittance test.It meets the requirements of jjg313-94 current transformer verification regulation and jjg314-94 voltage transformer verification regulation.
Product Introduction
1. Integration design of clamp meter and energy standards colorful and touch-screen display easy operation
2. Intelligent Li-battery power supply longest working time: 24 hours
3. Wide voltage and current measuring range: voltage 5-220V current 0.01-50A
4. Parameters display in one screen display
5. Automatic compensation accuracy reaches 0.1 class
6. Easy carrying strong anti-interference ability
7. 16 bits high precision AD converter 32 bit ARM processor core.
8. Data saving and calibration storage capacity up to 999groups of testing data
Product Overview
Adapts advanced technology TKGX Underground Cable Detector is the most effective device to detect underground utilities of gas electric power telecom water supply drainage cable television and etc.
Features
Portable designation suitable for wild field testing.
Full digital control easy to control.
English graphic display.
Transmitter designed with over load and overheating protection.
To detect the location and depth of underground cable accurately also is available for branch pipe or network construction underground cable.
Two detect methods: AC current gradient method and ground electric field method.
To locate and detect depth of underground cable synchronously.
Product Introduction
Underground cable fault locator is my company in order to cater to the advent of the era of power the power industry in the integration of many high-quality goods package the cable fault testing industry with the rapid development of the IT era as an opportunity the single chip microcomputer and laptop type of cable fault tester on the basis of embedded computer platforms to create suitable for cable fault testing industry characteristics of network cable fault testing service platform and systematic integration of the USB communication technology touch screen technology 3 g communications technology greatly improve the function of the use of the instrument and the use value and convenient site environment operation.Considering the increasing number of buried cables;The system satisfy the People's Republic of China power industry standard "DL/T849.1 ~ DL/T849.3-2004" electric power equipment dedicated testing equipment general technical conditions the system test by the host system multiple pulse generator the path of cable fault locator and instrument of four parts used in power cable fault test path the embedding depth of cable for airport and railway signal control cable and street lamp accurate test of cable fault.
Thanks to the hard work of many engineers in the company the product has reached the international level especially since the whole set of devices has surpassed the world level in portability.The core technology of the multi-pulse method has changed the traditional testing method which has fundamentally solved the problem of high-resistance fault waveform reading that was difficult to solve previously. After multi-pulse generator any complex high-resistance waveform can be converted into a very familiar and easy to identify low-voltage pulse short-circuit fault waveform.It solves the problem that the user cannot recognize the complicated high resistance fault waveform for a long time and improves the level of the key rough measurement.
TKBLQ-II zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-II zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable.
1. This machine adopts large screen LCD display all English menu operation easy to use.
2. High precision sampling and processing circuit and advanced Fourier harmonic analysis technology ensure more reliable data.
3. The instrument adopts high-speed magnetic isolation digital sensor to directly collect the input voltage and current signals which ensures the reliability and safety of the data.
4. Support wireless synchronous voltage sampling mode (type II).
5. The instrument can use electric field induction instead of PT secondary wiring (type I).
6. It has the functions of resistive current fundamental peak output and side phase correction.
7. The instrument is equipped with rechargeable battery calendar clock and micro printer which can store 120 sets of measurement data.
1. Wide range of measuring voltage can test up to 1000G (Max 2000G) insulation resistance
2. Three and a half bit LCD digital display of insulation resistance value
3. automatically shift resistance measuring range
4. environment temperature can be measured
5. self-clocking function short buzz every 15 seconds
6. automatically calculate and save R15S R60S R600S DAR and Polarization Index
7. Output short-circuit current larger than 5mA (meet fast charging request to capacitive load)
8. strong anti-interference ability stable and reliable reading
9. perfect protection safe for operation
10. powered by rechargeable Li-battery auto power off when battery energy is not enough
Application:
TK-15 insulator distribution voltage tester is used to test string of voltage distribution of AC circuit 35-500kV insulator. Insulator distribution voltage test meter also can do all kinds of 35kV and AC voltage measurement in laboratory. It is an ideal testing meter for the safety of line operation and the auxiliary tools for live operation.
Features:
This insulator voltage distribution tester use the static structure converted the measured voltage into electric field to measure so the impedance is high.
Small impact on tested system. The measured signal is amplified by the internal process and finally directly visualized voltage value by LCD.
Operate quickly simple and clear.
Application:
TKBLQ-I zinc oxide arrester tester is a special instrument used to test the electrical performance of arresters. The instrument is suitable for live or power failure detection of arresters of various voltage levels, so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-I zinc oxide arrester test instrument is easy to operate and easy to use. The whole measuring process is controlled by microcomputer. It can measure the total current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large screen.
Features:
1. 5.7 "320 Ã?? 240 LCD, high-speed thermal printer; graphic display, intuitive interface, easy to operate and use.
2. It is applicable to live arrester, power failure or laboratory.
3. The current and voltage sensors are completely isolated, safe and reliable. A, B, C three-phase arrester can be stored as a group of test data.
4. The instrument can test continuously, display voltage current curve, and print data and curve quickly.
5. The internal configuration memory can store 200 groups of test data when power down.
6. With RS232 communication interface, the test data can be exported through the upper computer.
7. High speed sampling frequency, advanced digital signal processing technology, strong anti-interference performance, high accuracy of measurement results.
8. It adopts dustproof, waterproof and anticorrosive engineering plastic sealing box, which is small in volume, light in weight and easy to carry.
1. The vacuum filtering device has the advantages of mature technology convenient use and high efficiency. It contains a number of taps can realize a number of filtering process. The use of water circulation device to replace the oil circulation pump make it more convenient with low failure rate
2. The air blast drying device adopts German technology the air duct is advanced the fan noise is small the performance is stable;
3. Microcomputer High precision intelligent control. Once set the temperature it self judge the heating power and display heating state.
4. Adjustable air inlet for temperature control and gas emissions.
5. digital electronic balance has correction function self-checking function and multiple modes
Product Introduction:
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL/ t506-2007 "insulation gas humidity measurement method for sulfur hexafluoride electrical equipment" and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Technical Parameters:
Measuring range Dew point value: -80~ +20
Moisture content: 0 ~ 19999uL/L
Product Introduction:
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.
The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
Introduction
3 phase transformer on-load tap changer testeris mainly used to test three-phase transient time, transition waveform, transition resistance, synchronization state, etc. The transformer on-load switch tester is a comprehensive transformer on-load switch measurement and tester, which is used to measure and analyze the electrical performance indicators of power transformers and special transformers on-load tap-changers. The transformer on-load switch tester can automatically capture and display the transition resistance during the transition process. There is also a process of time jumping.
Technical parameters
Three phase constant current source charge,charge current: 3A/1A; 0.6A/0.2A
Maximum voltage of the port: 24V
Maximum range of transition resistance: 100
Measuring range: 1A 0.4 20 0.2A 10 100
Record time of waveform:300ms
Sample rate: 30k
Resolution of time:0.1ms
Resolution of resistance: 0.1
Accuracy of transition resistance: ±5% Reading±0.1
Accuracy of transient time: ±0.5% Reading±0.2mS
Temperature: -10-40 Humidity:
Product description
Automatic tension tester Intermolecular Forces formed liquid surface tension.Numbers of tension reflect on liquid sample s physics and chemical properties, it is one of the most important index to product quality. automatic interfacial tension tester apply to GB/T6541,it can test kinds of liquid surface tension and boundary surface tesion.this method sample and accuracy,so it s used widely.
Specifications
Measuring range 0-200mN/m
Accuracy 0.1%( test result) 0.1 mN/m
Precision 0.1mN/m
Sensibility 0.1mN/m
Mains voltage AC220V 20% 50HZ 10%
Maximum power dissipation 20W
Suit ambient temperature 10 30
Suit ambient humidity RH
Overall dimensions 200 300 330(mm)
Weight 6kg
Function
It used electromagnetic force -balance-type transducer, improving the accuracy of the measurement
Demarcated one point and you can adjust the instrument, and it's very convenient.
the instrument can show current weight values and tesion Equivalence
the instrument can revise the test result Automatly
used high-quality screen,the life of screen extended
the instrument can storage 255 records
the instrument has a mini- printer,you can print the test result any time.
the instrument has RS232 interface equipment,it can connect to computer,and it convenient for data processing.Automatic tension tester Points for attention
Keep the Pt ring clean and circularity.clean the Pt ring with pure water,and burn it in flames,until the ring turn red.
You must be sure that the test container will be clean.if the test container is dirty,the test result can not be accuratly.you can use pure water to clean the test container several times and dry it.
If the instrument crashed violencly,you must be calibrated again.
Product description
120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90)
The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are (also available for sports), and measure the speed of the A point to the B point.
Technical parameter:
Measuring range 0.0001-999.9999 seconds
Timing accuracy 0. 01% 2 words
power supply AC 220V 10% 50Hz
power 5W
input signal Mechanical air contact or electrical signal (5-20V)
Reset method Manual or software clearing
Relative humidity 80%RH
Dimensions 195*175*80
weight 1.5 kg
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
Underground cable fault locator is my company in order to cater to the advent of the era of power the power industry in the integration of many high-quality goods package the cable fault testing industry with the rapid development of the IT era as an opportunity the single chip microcomputer and laptop type of cable fault tester on the basis of embedded computer platforms to create suitable for cable fault testing industry characteristics of network cable fault testing service platform and systematic integration of the USB communication technology touch screen technology 3 g communications technology greatly improve the function of the use of the instrument and the use value and convenient site environment operation.Considering the increasing number of buried cables;The system satisfy the People's Republic of China power industry standard "DL/T849.1 ~ DL/T849.3-2004" electric power equipment dedicated testing equipment general technical conditions the system test by the host system multiple pulse generator the path of cable fault locator and instrument of four parts used in power cable fault test path the embedding depth of cable for airport and railway signal control cable and street lamp accurate test of cable fault.
Thanks to the hard work of many engineers in the company the product has reached the international level especially since the whole set of devices has surpassed the world level in portability.The core technology of the multi-pulse method has changed the traditional testing method which has fundamentally solved the problem of high-resistance fault waveform reading that was difficult to solve previously. After multi-pulse generator any complex high-resistance waveform can be converted into a very familiar and easy to identify low-voltage pulse short-circuit fault waveform.It solves the problem that the user cannot recognize the complicated high resistance fault waveform for a long time and improves the level of the key rough measurement.
1. Wide range of measuring voltage can test up to 1000G (Max 2000G insulation resistance
2. Three and a half bit LCD digital display of insulation resistance value
3. automatically shift resistance measuring range
4. environment temperature can be measured
5. self-clocking function short buzz every 15 seconds
6. automatically calculate and save R15S R60S R600S DAR and Polarization Index
7. Output short-circuit current larger than 5mA (meet fast charging request to capacitive load)
8. strong anti-interference ability stable and reliable reading
9. perfect protection safe for operation
10. powered by rechargeable Li-battery auto power off when battery energy is not enough
1. The vacuum filtering device has the advantages of mature technology convenient use and high efficiency. It contains a number of taps can realize a number of filtering process. The use of water circulation device to replace the oil circulation pump make it more convenient with low failure rate
2. The air blast drying device adopts German technology the air duct is advanced the fan noise is small the performance is stable;
3. Microcomputer High precision intelligent control. Once set the temperature it self judge the heating power and display heating state.
4. Adjustable air inlet for temperature control and gas emissions.
5. digital electronic balance has correction function self-checking function and multiple modes
SMG6600 six channel differential protection vector tester is a kind of instrument which can measure primary side current secondary side current and secondary side voltage at the same time and then make analysis and report. The instrument can analyze three-phase unbalance degree and hexagonal vector diagram by measuring primary side current secondary side current and secondary side voltage and can output word and Excel files without upper computer software which is convenient for users Period processing report.
The instrument adopts high-precision data acquisition chip with analog 24 bit ADC precision DSP processing data arm and TFT touch screen display measurement data intuitively and conveniently.
1. At the same time measure the 1-3 AC voltage on the secondary side;
2. At the same time measure 1 to 3 AC currents on the primary side;
3. At the same time measure 1-3 AC current at secondary side;
4. Measure the phase between voltage current and voltage (angle between primary and secondary current);
5. Measurement of power grid frequency;
Measurement of active and reactive power;
7. Measurement of power factor;
8. Three phase voltage and current unbalance detection;
9. Secondary side phase voltage range: 1-500v secondary side current range: 1ma-10a primary side current: 100ma-5a;
10. Display hexagonal vector diagram (mixed primary side and secondary side);
11. It is used as leakage current meter;
12. Low power consumption design built-in rechargeable battery as backup power supply;
13. Automatic range user-friendly design of mouse operation;
14. Data storage can be exported through U disk which is convenient for user data processing;
15. The field measured data can be printed out by micro printer;
16. Export files in word and excel format to facilitate printing reports.
Product Introduction
this instrument is specially used to test power grid waveform distortion voltage fluctuation and flicker harmonic content and unbalanced three-phase power quality problems such as high precision testing instruments; at the same time it also have the the functions of electric parameter test the vector analysis.
Product Characteristics
Can accurately measure voltage current active power reactive power frequency phase Angle power factor and other electrical parameters
It can display the measured voltage and current phasor diagram the users can know the device wiring correctly or not through the analysis of vector diagram .
The current is measured by using the clamp transformer.Because using clamp current transformer measurementthe operators do not need to disconnect current loop can be measured convenient and safety. It can be equipped with different range of clamps according to the user's measurement range.
It can measure and analysis the power quality from the utility grid to the client's use its measure and analysis frequency deviation voltage deviation voltage fluctuation and flicker unbalanced three-phase voltage allowed degrees and power grid harmonic.
Can display the single phase voltage and current waveform and can also show three phase voltage and current waveform. All tests have screen lock function interface to facilitate users to reading and analyze the data.
Product Overview
TKKGG-H Series HV/LV Switch Cabinet Test Bench is mainly applied for ex-work energized testing for high voltage and low voltage cabinet manufacturers. The test bench could provide various AC/DC power source in order to detect switch cabinet.
Features
Reading directly: Digital meters to display current voltage power factor test value.
Measuring accurately: High precision test value is accurate.
Full protections: Each circuit is with air switch protection.
Portable: Small size light weight easy to move.
Product Introduction
The standard output of 4 phases of voltage and 3 phases of current
It could combine various type of current or voltage conveniently and has diversity type of protective experiment. Every phase of voltage output is 120V and the total of the parallel current is 120A. The fourth phase voltage Ux has many functions and it can be set to be 4 type of every three voltages or synchronism checking voltage or output any value of voltage.
Product Characteristics
1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output.
2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate.
3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc.
4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc.
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement.
1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ;
2. High Anti-interference ability accurate and reliable measurement;
3. Easy operation equipped with large LCD and American rotating mouse and micro printer
4. Simple wiring only connecting with tested down leads to finish all line parameter measurement
5. High speed micro-controller as inner core integrated structure
6. Fast testing process one sequence parameter testing time is 1 min
7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
Product Overview
TKDL Cable Identifier is designed to identify a special one within a group of cables during the power cables setting up moving maintaining and faults processing. It is suitable for all kinds of HV & LV cables.
Features
Can identify energized or de-energized cable.
The system is composed by signal transmitter receiver transmit clamp receive clamp and some connection leads.
Large power current pulse output.
On-site receiving signal is clear.
Light weight high sensitivity and anti-interference ability.
To identify needed cable with or without electric.
Accurate and fast identifying.
Reliable protective circuit.
Large diameter clamp suitable for all kinds of section surface cable.
Build-in large power insulated transformer there is no any electrical contact between mains supply and user.
Product Introduction
The normal operation of cable-communication and electric transport completely rely on the good condition of the cable-circuit. Once the circuit breaks down and without punctually examination and repairing it will no doubt trigger the mass economic loss and bad social influence. So the electric fault measuring testing instrument is a very important tool. The intellectual testing instrument uses multiple testing methods and adopts the most advanced electronic devices and with computer and special electronic technology combining our companyâ??s successful experience of long-time exploitation on cable-fault measuring testing instruments and it is absolutely of high tech intelligence and abundant functions.
Our cable-fault detector is a testing device of good integrity. It can test on the High Resistance Flashover Fault Grounding High and Low Resistance Fault Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument it can exactly detect the fault point. Furthermore it especially applies to test for various power cable and communication cable.
Product nickname Cable fault meter Power Cable Fault Teater Street Light Cable Fault Teater Cable fault finder Cable fault finder Portable cable fault location system Cable fault flash meter Geo Cable Fault Teater Cable Trailer Cable Fault Teater
This instrument is an instrument which is specially used for transformer loss parameters and line frequency parameters testing. The instrument has the advantages of ingenious design excellent performance and powerful functions. The interior adopts advanced multi A/D synchronous sampling and digital signal processing technology and successfully solves the problem of multi-channel signal synchronous measurement and calculation. The instrument adopts large screen liquid crystal display Chinese menu prompt simple operation equipped with high-speed thermal printer and has storage function convenient for data storage and printing. The instrument is small in volume light in weight easy to carry and is very convenient to use in the field. It greatly reduces the labor intensity of the experimenters and improves the working efficiency.
1. Large LCD display simple menu operation.
2. With thermal printer storage function.
3. Small volume and light weight suitable for field work.
Product Introduction
The three-phase phase voltammeter is used for measuring three-phase electrical parameters which can be used for high-precision measurement of voltage current phase Angle frequency power power factor and other electrical parameters of the Three phases.
The three-phase phase voltammeter is designed with a high-speed Cortex M3 processor plus a 24-bit high-speed ADC to measure and calculate electrical parameters. It has a completely graphical interface. True color displays The resolution of The 320Ã??240.
Product namesï¼?Smart digital three-phase phase voltammeter multi-function digital three-phase phase voltammeter three-clamp digital phase voltammeter three-phase phase voltammeter
Recommended products
Applications:
Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
Features:
1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.
SMG6600 six channel differential protection vector tester is a kind of instrument which can measure primary side current secondary side current and secondary side voltage at the same time and then make analysis and report. The instrument can analyze three-phase unbalance degree and hexagonal vector diagram by measuring primary side current secondary side current and secondary side voltage and can output word and Excel files without upper computer software which is convenient for users Period processing report.
The instrument adopts high-precision data acquisition chip with analog 24 bit ADC precision DSP processing data arm and TFT touch screen display measurement data intuitively and conveniently.
1. At the same time measure the 1-3 AC voltage on the secondary side;
2. At the same time measure 1 to 3 AC currents on the primary side;
3. At the same time measure 1-3 AC current at secondary side;
4. Measure the phase between voltage current and voltage (angle between primary and secondary current);
5. Measurement of power grid frequency;
Measurement of active and reactive power;
7. Measurement of power factor;
8. Three phase voltage and current unbalance detection;
9. Secondary side phase voltage range: 1-500v secondary side current range: 1ma-10a primary side current: 100ma-5a;
10. Display hexagonal vector diagram (mixed primary side and secondary side);
11. It is used as leakage current meter;
12. Low power consumption design built-in rechargeable battery as backup power supply;
13. Automatic range user-friendly design of mouse operation;
14. Data storage can be exported through U disk which is convenient for user data processing;
15. The field measured data can be printed out by micro printer;
16. Export files in word and excel format to facilitate printing reports.
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification.
1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use.
2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute.
3. The instrument is equipped with a micro printer which can print test data on site.
4. It can store 1000 sets of data and can communicate with PC by RS-232 interface.
5. The equipped data management software can be networked with the power system MIS software.
6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument.
7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
Product Introduction
this instrument is specially used to test power grid waveform distortion voltage fluctuation and flicker harmonic content and unbalanced three-phase power quality problems such as high precision testing instruments; at the same time it also have the the functions of electric parameter test the vector analysis.
Product Characteristics
Can accurately measure voltage current active power reactive power frequency phase Angle power factor and other electrical parameters
It can display the measured voltage and current phasor diagram the users can know the device wiring correctly or not through the analysis of vector diagram .
The current is measured by using the clamp transformer.Because using clamp current transformer measurementthe operators do not need to disconnect current loop can be measured convenient and safety. It can be equipped with different range of clamps according to the user's measurement range.
It can measure and analysis the power quality from the utility grid to the client's use its measure and analysis frequency deviation voltage deviation voltage fluctuation and flicker unbalanced three-phase voltage allowed degrees and power grid harmonic.
Can display the single phase voltage and current waveform and can also show three phase voltage and current waveform. All tests have screen lock function interface to facilitate users to reading and analyze the data.
product brief introduction Product Introduction
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
product brief introduction Product Introduction
series is the equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through which completely overcome the problems of long blow water time bottom water hard to dry easy to cause arcing within the coil. The device is light simple wiring and easy to read. Polarization compensation voltage is output directly by the case.
product features Product Characteristics
1. Electronic control and tune easy to operate.
2. The date of voltage and current are recorded in the panel reading without conversion.
3. One minute timing and tip function.
4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator.
5. Portable design suitable for on-site testing.
6. Four parts separated: control unit Intermediate Frequency T
Product Introduction
The TKJF-208 hand-held partial discharge detector is used to detect the local discharge power supply in medium and high voltage equipment.If no discharge is detected it does not mean that there is no discharge activity in medium and high voltage equipment.Power discharges often have an incubation period and the insulation may fail for reasons other than partial discharge.If a significant discharge is detected in equipment connected to the medium-high voltage power system the equipment maintenance department should be notified immediately.
product features Product Characteristics
a) Screen display: high-contrast 3.5 TFT color screen.
b) Data storage: 1000 groups of test data can be stored.
c) Working power supply: embedded 8.4V lithium battery for 8hs continuous operation.
d) Power supply: input 100-240VAC output 8.4V/3A charging time 3 4h.
e) Boundary dimension:230 * 120 * 55(mm).
f) Instrument weight:1.5kg.
g) Environment temperature: -25-45
h) Storage temperature: -35-60
Complete configuration: host machine sensor AC adapter connecting cable and transport case.
Product description
To satisfy the requirement for quick measurement of DC resistance of transformer, our Company has developed three-channel, DC resistance tester aiming at YN connection winding. The tester can fulfill functions such as simultaneous energization on three phases, independent current sampling, voltage sampling, as well as simultaneous measurement and display of three-phase resistance value and three-phase unbalance rate, thus can significantly reduce test time for DC resistance of transformer, solve the problem of long test duration for DC resistance of each tapped winding of electric power transformer. It requires only 1/3 of the time required by traditional method
Technical index
1. Output current: select current automatically (maximum 20 A)
2. Range ability: 0-100
3. Accuracy: 0.2% ±20-100
4. Minimum resolution: 0.1
5. Working temperature: -20-40
6. Ambient humidity: 80%RH, no condensation
7. Working power supply: AC220 V ±10%, 50 Hz±1 Hz
8. Volume: L 400 mm*W 340 mm*H 195 mm
9. Net weight: 8 kg
Product description
Transformer oil flash point tester is used to determine the flash point value of petroleum products. The instrument adopts electric ignition mode without any flammable gas and meets the requirements of GB3536-2008 and GB267-88. Moreover, it utilizes many kinds of latest technologies such as ARM series high-performance microprocessor, electric erasing memory (can store thousands of data records), 7-inch color liquid crystal display and touch screen and PID self-tuning, etc.
Technical index
Test range: 40~400
Test type: Open flash point
Temperature detection: Platinum resistance
Accuracy: ±1
Repeatability: Meet GB3536-2008 and GB/T 267-88
Display: 7-inch touch screen and colorful LCD
Information storage: 1000 test results can be stored
Ignition method: Electronic ignition
Cooling method: Forced air cooling
Atmospheric pressure: Automatic detection of atmospheric pressure, automatic correction of test results
Printer: Dot matrix thermal printer
Self-check function: Lift lever, scratch lever, printing, etc.
Power: 600VA
Power supply: (AC) 220V ±11V frequency: 50Hz ±2.5Hz
Ambient temperature:10~35
Ambient humidity: 90%
Packaging weight: about 17kg
Overview
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
Technical Parameters
Technical parameters
Measurement voltage range 0.5kV 1kV 2.5kV 5kV 10kV 20kV
Measurement voltage accuracy ±(5% 10V)
Short circuit current 10mA
Measurement range and accuracy
Measurement range
Resistance measurement
range
Accuracy
20M 0.01 19.99M ±(5%+3d)
200M 5.0 199.9M ±(5%+3d)
2000M 50-1999M ±(5%+3d)
20G 0.5-19.99G ±(5%+3d)
200G 5.0-199.9G ±(10%+3d)
2000G 50-1999G ±(20%+10d)
Product Description:
Transformer GIS SF6 switch CT/PT insulator bus bar cable bushing and others capacitive devices are the common primary electric equipments.
The complete set of frequency conversion series resonance test equipment is mainly used for ac withstand voltage test of cross-linked cable hydraulic generator main transformer bus GIS etc.
The complete set of frequency conversion series resonance test equipment is mainly composed of frequency conversion control power supply excitation transformer reactor capacitor voltage divider and compensation capacitor (optional).
Product Parameters:
technical parameter
Rated output voltage 0 1000kV and below
output frequency 30 300Hz
Resonance voltage waveform Pure sine wave waveform distortion rate 1.0%
Working time Full power continuous working time of 60min
Quality factor 30~90
Frequency regulation sensitivity 0.1Hz
Instability 0.05%
Working power supply Single-phase 220V or three-phase 380V ±10%
Power frequency 50Hz ±5%
Overview:
The Intelligent Tg dielectric loss tester is equipped with high voltage step-up transformer. Besides, it takes security measures like zero-cross closing, lightning protection, etc. During the experiment, different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantages of convenient and safe operation.
Technical index
The Intelligent Tg dielectric loss tester has: printer, keyboard, indicator and communication transmission.
Detect internal standard capacitor current: 10�¼A~1A
Positive connection measurement: 10�¼A~1A
Amount of negative connection side: 1A~1A
Side volume range: 0.001%
Product description AC DC high voltage dividerFRC series AC DC high voltage divider also known as FRC Divider, it is a kind of resistance-capacitance equivalent potential screen voltage division type high voltage measurement device, is mainly used for the measurement of pulsed high voltage, lightning high voltage and power frequency high voltage. It is the first choice for the replacement of high voltage electrostatic voltmeter.
Technical index
Item
FRC-50
Voltage grade(kV)
AC: 50
DC: 50
DC frequency(Hz)
Overview
Cable check and cable, cable lookups are a bit a bit of arbitrary wiring (no need to publicly line). It can greatly improve the construction progress, which is a new test tool in on-site construction such as electricity, telecommunications, automation control.
The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate.
Technical parameter:
Parameter Display the maximum row of LEDs 1000�©, the maximum distance of the quilt is 40km / 1.5mmmmmmmmma
size Transmitter Size: 135 * 70 * 24MM Receiver Size: 135 * 70 * 24mm
Function
1. The entire instrument consists of a transmitter and a receiver;
2. There is no need to determine the public line to make it easy to use;
3. Wire recognition, distribution, application to a part of the wire or multi-heeled wire;
4. One item can be identified, if you need to distinguish more wires can measure or use multiple instruments;
5. Can determine whether there is a short circuit or disconnect between the wires;
6. The receiver is also a disconnect detector that can be used to measure whether the wire is turned on;
7. The structure is small and easy to operate.
Overview
The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are (also available for sports), and measure the speed of the A point to the B point.
Technical parameter:
Measuring range 0.0001-999.9999 seconds
Timing accuracy 0. 01% 2 words
power supply AC 220V 10% 50Hz
power 5W
input signal Mechanical air contact or electrical signal (5-20V)
Reset method Manual or software clearing
Relative humidity 80%RH
Dimensions 195*175*80
weight 1.5 kg
Overview
Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals;
Technical parameter:
Fiber Ethernet port
S, ST, Mode, 1310nm;
IEC61850-9-1 / 2 / Le, Goose, IEEE-1588;
Send dispersion:
Product description
Ground continuity tester is the connecting part of power equipment and grounding gird, during long time run of power equipment, Connection is likely due to moisture and other factors, node corrosion, even fracture phenomenon, lead to lead off the assembly line and the main grounding grid connection point resistance increase, there is no security risk in the operation of the equipment, serious when will cause the equipment to run away from the grounding grid.
Technical index
Technical parameter
Product description
Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .
Technical index
Measuring range and accuracy
(Temperature, humidity: 23RH)
Model
BC2305
Rated
Voltage
250V
500V
1000V
2500V
5000V
Measuring Range
Product description:
Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices.
Major Technical Index
1. Environmental conditions
Temperature Humidity
Product description
Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry.
Technical Parameter
CTA-1000
Usage
CT PT
Output
Voltage measurement accuracy
CT Ratio
Range
1~40000
accuracy
PT Ratio
Range
1~40000
accuracy
Phase
Range
accuracy
0.5min
DC resistance
Range
0~300
accuracy
Burden
Range
0~1000VA
accuracy
Power supply
Environmental Conditions
Weight and Dimensions
Product Introduction
Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply.
product features Product Characteristics
1 the company's Triple frequency transformer is simple to operate reliable performance
2 can well meet the needs of transformers transformers withstand voltage
Leakage Protector Tester is well designed and manufactured for online measuring the leakage operating current leakage non-operating current leakage operating time of the leakage protector; adopt 16 characters blue display it is convenient and intuitive. The range of leakage current is 0~1000mA range of the leakage operating time is 0~999ms. It is a product with high accuracy small size light weight exquisite appearance easy to carry is an ideal tool for a variety of leakage protector in site or in laboratory testing.
1. Handheld type small and esay to operate
2. Can measure single phase or three phase all kinds of leakage protector
3. Auto test leakage operating current
4. Directly test leakage operating time
5. LCD display intuitive reading
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the latest Ministry of Power Standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made a measurement ( Isolation) The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results.
The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A and 200A recommended by national standards. The loop resistance can be directly measured under the condition of DC 100A and 200A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A 150A gears for users to choose; custom Test time the maximum setting time is 599S which is larger than the standard 60S; it is a very stable contact resistance tester with a resolution of 0.01�¼�© in China and its performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance of electric power and power supply departments and loop resistance test of high-voltage switch factory.
Product nickname Contact resistance tester switch loop resistance tester contact loop resistance tester contact (loop) resistance tester High Precision Micro Ohmmeter
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the Ministry of Power standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made measurement (isolated The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results.
The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A recommended by the national standard. The loop resistance can be directly measured under the condition of DC 100A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A gear position for users to choose; custom test time maximum The set time is 599S which is much larger than the standard 60S. It is a very stable contact resistance tester with a resolution of 0.01�¼�© in China. The performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance and high-voltage switch factory loop resistance test in electric power and power supply departments.
At present the contact resistance measurements of the conventional type QJ44 arms widely used in electric power system dc bridge and this kind of bridge test current mA level only it is difficult to find circuit conductor cross-sectional area to reduce defects when measuring contact resistance high-voltage switch electric circuit due to the contact between the oil film and the influence of the oxide layer several times the measured value is big can't reflect real contact resistance.Therefore the standard sd301-88 ac 500kV power equipment handover and preventive test regulations and the new version of preventive test regulations for power equipment stipulate that the measuring current of circuit breaker and isolating switch contact resistance is not less than dc 100A to ensure the accuracy of test results.
Micro Ohmmeter is designed in accordance with The implementation standard DL/ t845.4-2004 of The new Electric Power of The People's Republic of China which combines high-frequency switch The Power supply technology and digital circuit technology.It is suitable for measuring the circuit resistance of switch control equipment.The test current is 100A dc recommended by the national standard.The circuit resistance can be measured directly under the condition of current 100A and displayed by digital display.The instrument is accurate in measurement and stable in performance. It meets the requirements of high voltage switch maintenance and resistance test of high voltage switch factory circuit.
Product Introduction
TKJB - 1200 Six phase voltage and six phase current can be output, which has made it is possible to be any combination, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out a differential test of three-phase transformer.
Product Characteristics
1 Meet all field test requirements.The Microcomputer relay protection tester is a standard of six phase current six phase voltage output at the same time the current a/phase 30 voltage125V/phase.Six - phase current in parallel up to 180A.It can not only test the traditional relays and protection devices but also test the modern microcomputer protection especially the transformer differential protection and backup self-switching device the test is more convenient and perfect.
2ã??All kinds of technical indexes have reached the standard of DL/ t624-1997 "technical conditions of microcomputer test equipment for relay protection" issued by the ministry of electric power.
3 Classic WindowsXP operation interface man-machine interface friendly easy and quick to operate;The high-performance embedded industrial control computer and 8.4-inch TFT true-color display with a resolution of 800Ã??600 provide rich and intuitive information including the current working status of the device and various help information.
4 The native Windows XP system with recovery function to avoid illegal shutdown or misoperation caused by the system crash.
5 The device has an ultra-thin industrial The keyboard and a photoelectric mouse that handles everything just like a PC.
6 The main control board adopts DSP+FPGA structure and 16-bit DAC output which can generate high-density sinusoidal wave of 2000 points per week for the basic wave greatly improving the quality of waveform and improving the precision of tester.
7 High-fidelity linear power amplifier ensures the accuracy of small current and the stability of large current.
8 The Microcomputer relay protection tester with USB interface and PC communication directly without any connection easy to use.
9 Connect to laptop (optional) to run.Laptop computer and industrial computer use the same set of software no need to learn how to operate.
10 It is equipped with the independent auxiliary voltage source output the output voltage is 110V(1A) and 220V(0.6a) respectively.To be used by relays or protective devices that require dc working power.
11 With the function of software self-calibration it avoids the need to open the chassis and adjust the potentiometer to calibrate the precision thus greatly improving the stability of the precision.
High-Performance Industrial Control Computer
High performance Industrial control computer is adopted as the controlling computer, through which you can run the windows operating system directly. 6.4"TFT true color LCD display, tracking ball and optimized keyboard are allocated on the faceplate of this tester, which can be used without the external mouse and keyboard. USB interface, 10-100M net mouth and serial communication interface are located on the back plate of this tester, through which you can access data, communicate data and upgrade software conveniently.
The whole process and the result of the test will all be showed on the LCD. The English operational interface of the complete set is very friendly and convenient. The tracking ball and keyboard on the faceplate will implement the operation. The operation is simple and convenient, and is easy to be mastered. Operator only needs a little knowledge of computer.
Keyboard and mouse interface are also allocated on the faceplate. If you would like to use the external mouse and keyboard, through pluging them with corresponding interfaces, you can operate this tester just like operate a desk-top computer.
Application:
ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method.
Features:
Apply to all kinds of ground lead.(round bar flat bar angle iron).
Non-contact measured grounding resistance safe fast.
Without using assistant ground rod. Without interrupting the grounding of the device under test.
With double protecting insulation.
With strong anti-interference ability and high accuracy.
Use 5# alkaline batteries convenient for users.
The electric power production hold detector using embedded industrial microcomputer real-time operating system digital to analog pointer and digital code display perfect combination the whole list has a variety of output voltage level (2500 v 5000 v 10000 v) strong anti-interference analog pointer and digital synchronous display ac/dc simple operation automatic save measurement results etc. It is an ideal tester for measuring insulation resistance of transformers mutual inductors generators high voltage motors lightning arresters etc.
Product nickname Digital Megabyte meter pointer Megabyte meter insulation meter digital high voltage Megabyte meter high voltage insulation resistance tester insulation resistance meter insulation characteristics tester electric shake meter electronic insulation resistance tester high voltage Megabyte meter insulation resistance tester
TheBY2671 digital megohm meter (2500V) is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD.
Product nicknameï¼?Digital megohmmeter megohmmeter digital megohmmeter digital display insulation sheet insulation resistance by megger tester high voltage insulation resistance tester insulation resistance meter insulation characteristics tester electric shake table digital wave table digital display table digital megohmmeter digital megohmmeter high voltage digital insulation resistance tester high voltage insulation resistance tester digital high voltage megohmmeter digital high voltage megohmmeter high Voltage digital megohm meter digital insulation meter digital display insulation meter electronic insulation resistance tester digital insulation resistance tester digital display insulation resistance tester digital display insulation resistance tester insulation resistance meter digital electric megohm meter digital high voltage megohm meter high voltage megohm meter.
Product Introduction
The electrical integrity of grounding device refers to the grounding device should be between all kinds of electrical equipment grounding device parts and the electrical connectivity between each equipment that is direct current resistance value also known as electrical conductivity. Reliable and effective connection between grounding lead and ground network is the fundamental guarantee of safe operation of power equipment. Ground down lead is electric power equipment and the connection part of the network in the long running process of electric power equipment joint is likely to be affected due to factors such as moisture rust a node or even the phenomenon such as fracture lead to ground down lead and the main grounding network connection resistance increases which cannot meet the requirements of power regulation problems in the operation of the equipment in safe hidden trouble caused serious ground operation. Corrosion and even fracture may occur to the underground grounding pole and its connecting part of the grounding device. Therefore it is necessary to test the electrical integrity of ground equipment regularly.
Electric power industry standard DL/T475-2006 "guidelines for the grounding device parameters measurement regulation electric conductivity connectivity should choose special measuring instrument for 1 m instrumentresolution accuracy is not lower than 1.0 on the Richter scale are unlikely. Our company is based on this The standard developed Ground Continuity Tester is a portable Tester with a high degree of automation which is specially used to test the electrical integrity of grounding devices. Its various technical indicators meet or are superior to relevant standards. Ground Continuity Tester is a simple and convenient operation high precision fast test speed good retesting performance and intuitive reading. It is an ideal special instrument in line with the requirements of regulations which greatly facilitates the development of test projects and improves work efficiency.
Product nickname Ground lead down Tester and Ground Continuity Tester
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Product nickname Earth grid earth resistance tester earth grid earth resistance tester large earth grid earth resistance tester
Product Introduction
ground resistance tester rejects the traditional manual manual power generation method adopts advanced medium and large scale integrated circuit and applies DC/AC conversion technology to combine the three-end button and four-end button measurement mode into a new type of Ground Resistance meter..
The working principle is that the DC/AC converter in the machine changes DC into low-frequency constant current of AC and the circuit is formed by auxiliary ground electrode C and measured object E which generates AC voltage drop on the measured object and is fed into AC amplifier for amplification through auxiliary ground electrode P and then sent to the meter head for display through detection. With the aid of multiplying power switch three different quantity limit can be obtained: 0 ~ 2 0 ~ 20 0 ~ 200 .
Didital ground resistance tester is suitable for measuring Ground Resistance of various devices and conductor Resistance of low Resistance in electric power post and telecommunications railway communication mining and other sectors; Didital ground resistance tester also measures soil resistivity and Ground voltage.
Product nickname Ground Resistance Tester Didital Ground Resistance Tester Ground contact Resistance meter Ground Resistance meter Ground pile Didital Ground Resistance Tester digital Ground Resistance meter portable Didital Ground Resistance Tester digital Ground Resistance meter Didital Ground Resistance meter Tester
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates.
1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display.
2. With computer interface improve the level of office automation and reduce the labor intensity.
3. Can have a large screen display provide a friendly operation interface and rich measurement information.
4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box.
5. Possess good catching measures and be able to promptly inform users of wrong information.
6. This automatic transformer calibration station can reach level 2.
7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.
SMG7000 Handheld Power Quality Analyzer Input Characteristics
1. Voltage measuring range: 0~400V auto.
2. Current measurement range
3. Clamp transformers (three): 5A/25A (standard)
100A/500A (optional)
400A/2000A (optional)
4. Phase angle measurement range: 0~359.99 �°.
5. Frequency range: 45~55Hz.
6. Voltage number of channels: three channels (UA UB and UC).
7. Current number of channels: three channels (IA IB IC).
8.Maximum number of harmonic analysis: 63 times.
9. Intervals of 1 minute maximum storage period: 18 months
Product Introduction
3-phase energy meter calibrator introduction:
HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
Product Characteristics
3-phase energy meter calibrator introduction:
TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument.
3-phase energy meter calibrator technical parameters:
Input feature
Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range.
Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional)
Phase angle measuring range: 0 ~ 359.999
Frequency Measurement Range: 45 ~ 55Hz.
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification.
1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use.
2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute.
3. The instrument is equipped with a micro printer which can print test data on site.
4. It can store 1000 sets of data and can communicate with PC by RS-232 interface.
5. The equipped data management software can be networked with the power system MIS software.
6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument.
7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
Product Introduction
this instrument is specially used to test power grid waveform distortion voltage fluctuation and flicker harmonic content and unbalanced three-phase power quality problems such as high precision testing instruments; at the same time it also have the the functions of electric parameter test the vector analysis.
Product Characteristics
Can accurately measure voltage current active power reactive power frequency phase Angle power factor and other electrical parameters
It can display the measured voltage and current phasor diagram the users can know the device wiring correctly or not through the analysis of vector diagram .
The current is measured by using the clamp transformer.Because using clamp current transformer measurementthe operators do not need to disconnect current loop can be measured convenient and safety. It can be equipped with different range of clamps according to the user's measurement range.
It can measure and analysis the power quality from the utility grid to the client's use its measure and analysis frequency deviation voltage deviation voltage fluctuation and flicker unbalanced three-phase voltage allowed degrees and power grid harmonic.
Can display the single phase voltage and current waveform and can also show three phase voltage and current waveform. All tests have screen lock function interface to facilitate users to reading and analyze the data.
Digital double clamp Phase voltammeter is a high-precision low-price hand-held double-channel input measurement instrument designed for voltage current and Phase measurement on site.Using this meter the phase between u-u i-i and u-i can be easily measured in the field the phase sequence of sensitive and capacitive circuits and three-phase voltage can be distinguished the wiring group of transformers can be detected the secondary circuit and bus differential protection system can be tested the phase relationship between CT of each differential protection group can be read out and the wiring of the electricity meter can be checked.The tongs current transformer is used to input the measured current so there is no need to disconnect the measured line.When measuring the phase between u1-u2 the two input circuits are completely insulated and isolated so it completely avoids the possible short-circuit of the measured circuit caused by wrong wiring and thus burns out the measuring instrument.The display screen USES high-contrast Liquid crystal display with words up to 25mm and The screen Angle can be freely converted to about 70 to obtain better visual effects.
Digital double clamp Phase voltammeter enclosure USES engineering insulation materials another rubber vibration protection sleeve safe and reliable.
Product namesï¼?Phase meter double clamp Phase meter double clamp Phase voltammeter clamp forms a table clip-on Phase voltammeter Digital Phase double clamp Phase meter Digital double clamp table low-pressure volt-ampere Phase inspection table hand-held Digital double clamp Phase voltammeter double clamp type Digital Phase meter double clamp Digital Phase meter double clamp type volt-ampere Phase meter double clamp volt-ampere Phase table double clamp Phase meter Digital display double clamp Phase voltammeter
Product Characteristics
1 Simultaneous measurement of three-phase voltage or four-channel current (including zero current)
2 At the same time the phase Angle current phase Angle and work Angle of three-phase ac voltage are measured
3 Measure the frequency and phase sequence of the grid
4 Automatic discrimination of transformer winding capacitive and inductive load
5 Hexagon diagram display color phase sequence analysis
6 Measurement of active power reactive power apparent power three-phase power and power factor
7 Data view and save function
8 Data static storage function
9 The 3.5-inch TFT color screen display has touch function
10 The three-phase phase voltammeter is powered by lithium battery and can be standby for more than 20 hours with a single charge
Applications:
Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
Features:
1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.
Send InquiryCHAT NOW
Product Details
Product description 60KV 2ma DC Cable Test System is designed and manufactured based on the latest China electric power industrial standard DL/T848.1-2004 General Technical Specifications of DC High Voltage Generator. It is mainly applicable for DC withstand voltage tests on high-voltage electrical equipment such as zinc oxide arrester, power cables, transformers, and generators used in electric power departments, mine industry, and metallurgy and iron & steel enterprises.
Product Description:
Transformer GIS SF6 switch CT/PT insulator bus bar cable bushing and others capacitive devices are the common primary electric equipments.
The complete set of frequency conversion series resonance test equipment is mainly used for ac withstand voltage test of cross-linked cable hydraulic generator main transformer bus GIS etc.
The complete set of frequency conversion series resonance test equipment is mainly composed of frequency conversion control power supply excitation transformer reactor capacitor voltage divider and compensation capacitor (optional).
Send InquiryCHAT NOW
Product Details
Product introduction
Series resonance device is mainly designed and manufactured for communication voltage endurance test of 11kV/30MW hydro-generator. Two separate designs are adopted for reactor.
Series resonance device is mainly composed of frequency conversion control power supply excitation transformer reactor and capacitor voltage divider.
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
TKHG-Q current transformer field calibrator was developed based on high-end testing technology large-scale electronic circuit design and in compliance with relevant national regulations. It solves the problems of on-site verification of current transformer and voltage transformer with high working intensity and tedious operation. At the same time the product has reliable performance and powerful functions.
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification.
1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use.
2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute.
3. The instrument is equipped with a micro printer which can print test data on site.
4. It can store 1000 sets of data and can communicate with PC by RS-232 interface.
5. The equipped data management software can be networked with the power system MIS software.
6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument.
7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
WFLC-VI Portable Waveform Recorder is a portable device based on the structure of industrial portable computer. It takes high-performance DSP high-precision ADC chip and embedded operating system as hardware and software architecture and integrates data acquisition processing transmission storage analysis and other functions as one.
DSP acquisition chip for data acquisition and calculation so as to achieve full digital analog signal filtering flexible and diverse sampling frequency from 10K /s 20K /s 50k/s 100K /s can be selected by users can be used for transient electrical signal waveform recording and analysis.
With advanced industrial control kernel and embedded operating system users can easily carry out data storage backup analysis output and other operationsã??
WFLC-VI portable waveform recorder is a collection of fault wave record generator characteristic test and other functions in the integration of intelligent instrument with its small size strong function scope of application is wide flexible configuration and many other advantages favored by the masses of users is a power utility workers standing it will be for the electric power industry production and technological progress to make due contributions.
product features
1 The reactor of the same voltage grade and capacity has smaller volume and lighter weight. Small temperature rise at rated load; Dry pouring high mechanical strength good electrical insulation beautiful and reliable.
2 Large capacity margin of frequency conversion power control box; Strong protection function; Good output waveform; Good stability; With a variety of working modes easy to operate; Single-phase 220V or three-phase 380V input power supply is common which is convenient for on-site power collection.
3 Flexible configuration. Can choose different types of reactor meet the requirements of different test products achieve a multi-purpose cost-effective.
Leakage Protector Tester is well designed and manufactured for online measuring the leakage operating current leakage non-operating current leakage operating time of the leakage protector; adopt 16 characters blue display it is convenient and intuitive. The range of leakage current is 0~1000mA range of the leakage operating time is 0~999ms. It is a product with high accuracy small size light weight exquisite appearance easy to carry is an ideal tool for a variety of leakage protector in site or in laboratory testing.
1. Handheld type small and esay to operate
2. Can measure single phase or three phase all kinds of leakage protector
3. Auto test leakage operating current
4. Directly test leakage operating time
5. LCD display intuitive reading
ntroduction
TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches.
Features
1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes.
2. Need not disassemble the vacuum switch during the field test.
3. High precision.
4. With LCD easy to operate.
5. Can save print and review the test results.
6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life.
7. Light in weight easy to carry.
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the latest Ministry of Power Standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made a measurement ( Isolation) The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results.
The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A and 200A recommended by national standards. The loop resistance can be directly measured under the condition of DC 100A and 200A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A 150A gears for users to choose; custom Test time the maximum setting time is 599S which is larger than the standard 60S; it is a very stable contact resistance tester with a resolution of 0.01�¼�© in China and its performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance of electric power and power supply departments and loop resistance test of high-voltage switch factory.
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the Ministry of Power standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made measurement (isolated The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results.
The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A recommended by the national standard. The loop resistance can be directly measured under the condition of DC 100A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A gear position for users to choose; custom test time maximum The set time is 599S which is much larger than the standard 60S. It is a very stable contact resistance tester with a resolution of 0.01�¼�© in China. The performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance and high-voltage switch factory loop resistance test in electric power and power supply departments.
Application:
TKBLQ-I zinc oxide arrester tester is a special instrument used to test the electrical performance of arresters. The instrument is suitable for live or power failure detection of arresters of various voltage levels, so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-I zinc oxide arrester test instrument is easy to operate and easy to use. The whole measuring process is controlled by microcomputer. It can measure the total current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large screen.
Features:
1. 5.7 "320 Ã?? 240 LCD, high-speed thermal printer; graphic display, intuitive interface, easy to operate and use.
2. It is applicable to live arrester, power failure or laboratory.
3. The current and voltage sensors are completely isolated, safe and reliable. A, B, C three-phase arrester can be stored as a group of test data.
4. The instrument can test continuously, display voltage current curve, and print data and curve quickly.
5. The internal configuration memory can store 200 groups of test data when power down.
6. With RS232 communication interface, the test data can be exported through the upper computer.
7. High speed sampling frequency, advanced digital signal processing technology, strong anti-interference performance, high accuracy of measurement results.
8. It adopts dustproof, waterproof and anticorrosive engineering plastic sealing box, which is small in volume, light in weight and easy to carry.
Product Characteristics
1. small size, light weight.
2. the measurement process is safe, fast, accurate measurement results.
Product Parameters
1.Ambient temperature: -10 C~+50 C
2.Relative humidity: 20~90%(at 40 C)
3.atmospheric pressure:86~106kPa
4.Discharge test voltage: > 2kV
5.Charge time: < 1 minute
6.Power supply: 220V±10% Frequency: 50±1Hz Power < 30vA
7.Dimension: 300 200 180mm
8.Weight: 4KG
1.Test voltage: 5000V DC
2.Range: 0-1999M
3.Resolution: 1M
4.Basic error: ±5%
5.Power supply: one cell 9V layer-built battery
6.Power source current: about 20mA
7.Environment temperature: 0-40
8.Environment humidity:85%
9.Dimension: 120-70 50mm
Summary
The Arrester is suitable for testing the internal defects of 10KV and below 10KV MOA (metal Oxide Arrester).Before the annual season of thunderstormsit 's necessary to test metal Oxide using 1mA DC voltage and 0.75U1mA leakage current at Power plants/substations.The equipment was developped according to the requirement of site it 's integrated with DC HV supplymeasurement and control system. it has the characters of small size and light weight.
Feature
1.Supply power: AC220V or Charging battery.
2.LCD display test datas.
3.Convenient to carry.
Application:
TKQH-SF6 Series vacuum pumping and inflation device is mainly used for vacuum pumping and vacuum degree determining of magnetic pole SF6 circuit breaker transformer and other SF6 electric appliances when installation operation and maintenance. The entire SF6 gas inflation and vacuum pumping device comprises a vacuum pump a pointer type vacuum gauge a regulating valve a gas transmission pipe and a valve and SF6 circuit breaker necessary control components for maintaining.
Features:
Quick pumping.
Regulate pressure to inflate.
Solid structure.
High precision thermocouple vacuum gauge.
Handheld SF6 Gas Product Introduction
We have more than 30 years of production experience recently launched a new generation of automatic intelligent leak detector.It is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users.At the same time we apply our rich technology and experience to this product so that users can enjoy excellent performance and price ratio.
The high-tech central microprocessing unit is the core of sf6 gas qualitative leak detector. Its digital signal processing ability can better manage the circuit and process the detection signal. Due to the large number of integrated circuits the number of components in the circuit is reduced by 40% which greatly improves the reliability and efficiency. The microprocessor can monitor the probe and battery voltage at the rate of 4000 times per second. Even the tiniest signal can be captured. It can work stably and reliably in any environment.
The sf6 gas qualitative leak detector has added some convenient functions. The seven-level sensitivity increases the sensitivity by 64 times. The three-color leds indicate the degree of leakage in a wide range in a progressive manner and are also used to display sensitivity levels and battery power.Touch keyboard for all operations. Avant-garde long and thin shape design greatly facilitates users to use and maintain. It is very convenient to use the indicator light in the direct range.
Product nickname SF6 qualitative leak detector automatic SF6 qualitative leak detector SF6 gas qualitative leak detectorLeak Detector
Product Introduction
SF6 comprehensive tester is a collection of sf6 micrometer sf6 purity tester sf6 decomposition product analyzer in one concentrate the functions of three instruments in one instrument. One on-site measurement can complete the detection of three indicators greatly saving gas in the equipment. One measurement can save 2/3 gas consumption reduce the workload of users and improve the work efficiency.
Product nickname SF6 comprehensive tester fully automatic SF6 comprehensive tester automatic SF6 comprehensive tester
product brief introduction Product Introduction
The intermolecular forces form the interfacial tension or surface tension of the liquid. The value of the tension can reflect the physical and chemical properties of the liquid and its material composition. It is one of the important indicators for the inspection of product quality in related industries.Automatic statically tester manufactured by our company applies GB/T6541 standard and measures the surface tension of various liquids (liquid-gas phase interface) and liquid interface tension (liquid-liquid phase interface) based on the ring method (platinum ring method).This method is widely used because of its advantages of simple operation and high accuracy.Widely used in electric power petroleum chemical pharmaceutical food teaching and other industries.
Product Introduction
In power system and industrial and mining enterprises have a lot of oil-filled electrical equipment transformer oil and the acid value of turbine oil is a routine inspection items shall be measured acid tester used in transformer oil steam turbine oleic Acid value measuring instrument adopt computer control electric light chemical integration design of full - automatic machine entirely replace the manual operation improve work efficiency reduce the labor intensity of the workers minimize the organic solvents and chemicals to the harm of human body operation simple easy to use strong anti-interference ability stable and reliable.
The acid value is the number of milligrams of potassium hydroxide required to neutralize the acid in a gram of mgKOH/g oil and is one of the most tightly controlled quality indicators It is one of the indexes which should be strictly controlled in oil quality. Petroleum products acid tester GB/T264-83Standards developed and produced It is suitable for detection transformer oil turbine oil and anti - fuel oil.Through the comprehensive application of mechanical optics electronics and other technologies the product adopts advanced microprocessor and can realize self-motion function of multi-sample switching titration judge titration end point print measurement results and other functions and the system is stable and reliable self-motion high degree of chemical can be widely used in electric power chemical environmental protection and other fields.
product brief introduction Product Introduction
Automatic Closed Flash Point Tester used to measure the Closed flash point value of petroleum products.Advanced foreign technology is adopted. LCD TET's pure color touch screen displays the man-machine dialogue interface in Chinese. For parameters such as prevalue temperature oil test label atmospheric pressure and test date it has prompt menu prompt input which is convenient and fast.It is an ideal substitute for imported instruments.Widely used in railway aviation electric power petroleum industry and scientific research departments.
Product nickname FlashPoint Tester Automatic Closed Flash Point Tester Closed flash point automatic tester closed-cup flash pointfull-automatictester self-motionClosed flash point tester Closed flash point tester
Product Introduction
In the preventive insulation test of power equipment it is required to measure the insulation oil parameters of power equipment periodically. The measurement of dielectric loss and resistivity of insulating oil is one of the most important. For a long time most of them adopt the bridge method for measurement which is complicated in operation and the measurement accuracy is affected by many factors thus leading to a large measurement error. With the rapid development of electronic technology and the power industry for small volume light weight easy to operate rapid measurement high precision measurement instrument requirements I refer to domestic and foreign related instruments developed in the domestic leading insulation oil dielectric loss factor and dc resistivity tester. The instrument is designed and manufactured according to gb5654-2007 and related standards. It is controlled by microcomputer easy to use high measurement accuracy high test efficiency and greatly reduces labor intensity.
Product Introduction
In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB/ t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL/ t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China.
Product names insulation oil tester oil pressure tester insulated oil pressure tester oil dielectric strength tester insulation oil dielectric strength tester insulation oil pressure tester automatic insulation oil tester microcomputer automatic insulation oil tester automatic oil tester automatic oil tester portable oil pressure test device electrical strength tester
Product Introduction
TKYND full-automatic full-automatic kinematic viscosity tester is a new product newly launched by our company which is used to determine the kinematic viscosity of petroleum products. It is applicable to the national standard GB/T 265-1988. This instrument combines the advantages of our company and the original similar products at home and abroad carries out a new design concept is the older generation of kinematic viscosity tester replacement products.
Product Names automatic kinematic viscosity meter automatic kinematic viscosity tester determination of kinematic viscosity viscosity meter automatic kinematic viscosity meter
Product Introduction
In the power system and factories mines enterprises have a large number of oil filling equipment. The flash point of insulating oil is a routine test item that must be measured. KKY open flash point tester is a replacement of the current open flash point tester for petroleum products. This instrument is based on the national standard GB/ t3536-2008 which requires the determination of samples. The whole determination process is carried out automatically. The instrument adopts the super large screen liquid crystal display the determination is accurate the performance is stable can completely satisfy the petroleum chemical industry the electric power the scientific research and so on department determination petroleum product open flash point need the use is very convenient deeply the majority of oil workers welcome.
Product Names open flash point tester automatic open flash point tester automatic open flash point tester automatic open flash point tester
Product Introduction
With the development of China's electric power industry the capacitor compensation device has been unprecedentedly developed but with it the capacitor accident rate has risen sharply and there have been serious group injury accidents. In order to prevent the occurrence of parallel capacitor accidents and ensure the safe and reliable operation of the power grid State Grid Corporation has formulated the "Measures for Preventing High Voltage Shunt Capacitor Accidents". It is clearly stated that "the measurement of the capacitance of a single capacitor of a capacitor bank should be carried out on a regular basis. It is recommended to use a measurement method that does not remove the connecting wire to avoid the failure of the casing to leak due to the force of the casing caused by the disassembly and assembly of the connecting wire".
Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 "High Voltage Shunt Capacitors" DL/T840-2003 "Technical Conditions for Use of High Voltage Shunt Capacitors" and JB5346 -1998 "Series reactor" and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device.
Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data.
Product Introduction
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
Product Characteristics
1. With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
2. The short-circuit current of test power> 5mA, maximum up to 15mA. Be suitable for testing high capacity and high inductance.
3. Wide resistance range from 0.5M�© ~ 200000M�©. With high-resolution, having accurate readings.
4. Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV, you can smoothly adjust voltage from 0V to the desired value.
5. With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.
With the continuous update and expansion of modern technology higher requirements are put forward for the reliability of power system and high-voltage equipment. Accidents or damage of electrical equipment are usually closely related to insulation defects. Large capacity of electrical equipment high voltage structure diversification and sealing electrical equipment should be put forward a new higher requirements. With the increasing use of large-capacity equipment the insulation performance cannot be detected by ordinary megohm meter.
Power test procedures for a number of power equipment such as: cable motor generator transformer transformer high voltage switch lightning arrester and other requirements to do a series of insulation performance tests the first is to do insulation resistance test.
When testing the insulation resistance of large-capacity power equipment the insulation resistance value is related to the pressurizing time. The longer the pressurizing time is the higher the insulation resistance value is. This phenomenon is called insulation absorption phenomenon. In order to understand the insulation performance of the subject it is necessary to conduct the absorption ratio and polarization index test first so as to provide safety guarantee for the next leakage dielectric loss partial discharge and insulation performance test. According to the electric power standardization regulations our company specially introduces BC2010 Insulation Resistance Tester with large capacity high anti-interference and stable performance which can conduct Insulation absorption ratio and polarization index tests on electric power equipment providing accurate judgment in the early stage for series Insulation tests.
Product nicknameï¼?Digital megohmmeter pointer megohmmeter insulating sheet Insulation Resistance Tester high voltage Intelligent Dual Display Insulation to hold Tester Insulation Resistance meter Insulation characteristics Tester high voltage megohmmeter with the function of absorbing than megohmmeter megohmmeter with polarization index function the electric shake tables electronic Intelligent Dual Display Insulation to hold Tester high-power high-voltage megohmmeter
Product Introduction
Digital PD Detector Partial Discharge Testing
Digital PD Detector Partial Discharge Testing Product Overview
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method).
Through a variety of means to suppress various external noise interference it improved signal to noise ratio and measurement accuracy.
product features Product Characteristics
Digital PD Detector Partial Discharge Testing Working Condition
Altitude3000m
Environmental Temperature -20~60°C
Relative Humidity 95%
product brief introduction Product Introduction
Alternating and direct current amphibious light AC DC Hipot Test Set. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Product Introduction
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A.
1. The instrument can be used separately or linked to PC.
2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system.
3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability.
4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity.
5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure.
6. Two options: ampere-second characteristic test or through current characteristic test.
7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation.
8. Protection functions for overheat over-current and over voltage.
9. Anti-interference capacity and good EMC(electromagnetic compatibility).
TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches.
Features
1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes.
2. Need not disassemble the vacuum switch during the field test.
3. High precision.
4. With LCD easy to operate.
5. Can save print and review the test results.
6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life.
7. Light in weight easy to carry.
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the Ministry of Power standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made measurement (isolated The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results.
The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A recommended by the national standard. The loop resistance can be directly measured under the condition of DC 100A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A gear position for users to choose; custom test time maximum The set time is 599S which is much larger than the standard 60S. It is a very stable contact resistance tester with a resolution of 0.01�¼�© in China. The performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance and high-voltage switch factory loop resistance test in electric power and power supply departments.
The standard output of 4 phases of voltage and 3 phases of current
It could combine various type of current or voltage conveniently and has diversity type of protective experiment. Every phase of voltage output is 120V and the total of the parallel current is 120A. The fourth phase voltage Ux has many functions and it can be set to be 4 type of every three voltages or synchronism checking voltage or output any value of voltage.
Single Phase Relay Test Set General
TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay.
Product Characteristics
Single Phase Relay Test Set Main Features
1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range.
2 Maximum Output Current:0150Aã??
3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state.
4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement.
5 Light-weight design, small-volume, and fully-functional.
KDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables.
1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use.
2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
product description
Oil trace moisture tester This instrument is able to work more reliably and conveniently by using the most advanced control circuit and 32 bit embedded microcontroller processor as the master control core and utilizing embedded mini operating system.
Oil trace moisture tester (2)
Technical index:
Titration method Coulometric titration Coulomb analysis
Display Color LCD touch screen
Electrolytic current control 0 400mA automatic control
Measurement scope 3ug 100mg
Sensitive valve 0.1 µg H2O
Accuracy 10 µg 1000 µg ±3 µg
More than 1mg but not greater than 0.3%
Printer Miniature thermal printer
Power supply 220V ±10% 50Hz
Power 40W
Ambient temperature 5 40
Ambient humidity 85%
External dimension 340 295 155
Weight About 5.5kg
Product description
The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple.
Main technical indicators and conditions of useï¼?
Measurement accuracy: voltage, current: 0.2 level
Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade
Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade
Voltage measurement range: AC 3V300V
Internal power output range: voltage 0~250V, current 0~10A
Current measurement range: AC 0.2A 20A
Working temperature: -10-50
Working humidity: 0-80%
Working power supply: AC220V 10-50Hz1Hz
Dimensions: 360mm-220mm 150mm
Weight of the instrument: 20Kg
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Product Characteristics
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;
2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;
4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
Product description
Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry.
Technical Parameter
CTA-1000
Usage
CT PT
Output
0~180Vrms 12Arms 36A peak value
Voltage measurement accuracy
±0.1%
CT Ratio
Range
1~40000
accuracy
±0.05%
PT Ratio
Range
1~40000
accuracy
±0.05%
Phase
Range
±2min
accuracy
0.5min
DC resistance
Range
0~300
accuracy
0.2%±2m
Burden
Range
0~1000VA
accuracy
0.2%±0.02VA
0.2%±0.02VA
Power supply
AC220V ±10% 50Hz
Environmental Conditions
Operating temperature : -10 C~50 C Humidity : 90%
Weight and Dimensions
Dimensions: 365 mm 290 mm 153mm,Weight
Product description
Petroleum Kinematic Viscometer for conforms to GB/T 265-1988 "Measuring and calculating method for kinematic viscosity of petroleum products", which is applicable to test the kinematic viscosity of liquid petroleum products (Newtonian liquids). It is used to measure the time when a certain volume of liquid flowing through a calibrated glass capillary viscosimeter under the gravity at a constant temperature. The product of capillary viscosimeter constant and flow time is the kinematic viscosity of liquid at that temperature.
Technical indexï¼?
Display: Color LCD display and touch screen
Temperature control range: Room temperature~150
Overview
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
Overview
Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. .
The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits 0 2 0 20 0 200
Overview
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. measurable substation ground network (4) water and fire power plants microwave station (10) the lightning rod 10 multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Overview
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
Technical Parameters
Technical parameters
Measurement voltage range 0.5kV 1kV 2.5kV 5kV 10kV 20kV
Measurement voltage accuracy 5% 10V
Short circuit current 10mA
Measurement range and accuracy
Measurement range
Resistance measurement
range
Accuracy
20M 0.01 19.99M 5%+3d
200M 5.0199.9M 5%+3d
2000M 50 1999M 5%+3d
20G 0.519.99G 5%+3d
200G 5.0199.9G 10%+3d
2000G 50 1999G 20%+10d
Product description
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Technical index
1
Conditions of use
15 40
RH 80%
2
Anti-interference principle
Frequency conversion method
3
Electric source
AC 220V 10%
allowed generator
4
Measure output current
1A 5A Adjustable
5
Measure output voltage
V100V
6
Test power frequency
45, 50, 55, 60, 65HZ single frequency
45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency
7
Output rating
500W
8
Distinguishing rate
Grounding impedance 0.0001
Impedance angle 0.0001
9
Precision
Grounding impedance (1% reading +0.002)
Impedance angle (1% reading +0.02 )
10
Resistance measurement range
0.001 5
Product description
Ground continuity tester is the connecting part of power equipment and grounding gird, during long time run of power equipment, Connection is likely due to moisture and other factors, node corrosion, even fracture phenomenon, lead to lead off the assembly line and the main grounding grid connection point resistance increase, there is no security risk in the operation of the equipment, serious when will cause the equipment to run away from the grounding grid.
Technical index
Technical parameter
Current 10A 5A 1A 100mA
Range 10A 500 2
5A 1m 4
1A 10m 20
100mA1 200
Resolution 0.1
Precision 0.2%R 2D
Radius 50m
Dimension 345mm 295mm 175mm
Weight 5kg
Operation condition
Temperature -10 50
Humidity 85% RH
Power supply AC220V 10%
Frequency 50 1Hz
Product description
Automatic tension tester Intermolecular Forces formed liquid surface tension.Numbers of tension reflect on liquid samples physics and chemical properties, it is one of the most important index to product quality. automatic interfacial tension tester apply to GB/T6541,it can test kinds of liquid surface tension and boundary surface tesion.this method sample and accuracy,so it s used widely.
Specification
.
Working Principle
When measured piece Cx has partial discharge under testing voltage the circuit will have pulse current which get by the input unit. The pulse signal is amplified by front amplifier and the frequency band is chose by filter amplifier then been amplified to needed amplitude by the main amplifier. The pulse signal will be displayed on oscillograph screen. The pulse value is also sent to the pulse peak meter and displayed immediately. The time window unit chooses a working period of the pulse peak meter during each cycle of testing voltage and it increases the brightness of the relevant displaying area in this time. In this way it can avoid the disturbing of fixed phase.
Input discharge volume to the measured piece Cx through JZF series PD external calibrator adjust the fine adjusting knob till the displayed value is equal to the discharge volume the discharge can be read directly and conveniently on the meter without counting.
The testing voltmeter will have an over zero mark signal of testing voltage through the voltmeter resistance R and the zero mark pulse will be displayed on oscillograph screen. The testing voltage can be displayed on KV meter.
1. Electronic control and tune easy to operate.
2. The date of voltage and current are recorded in the panel reading without conversion.
3. One minute timing and tip function.
4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator.
5. Portable design suitable for on-site testing.
6. Four parts separated: control unit Intermediate Frequency Transformer doubler and accessories all packed with special shockproof aluminum alloy cabinet easy to move.
a) Screen display: high-contrast 3.5 TFT color screen.
b) Data storage: 1000 groups of test data can be stored.
c) Working power supply: embedded 8.4V lithium battery for 8hâ??s continuous operation.
d) Power supply: input 100-240VAC output 8.4V/3A charging time 3 4h.
e) Boundary dimension:230 * 120 * 55(mm).
f) Instrument weight:1.5kg.
g) Environment temperature: -25 45
h) Storage temperature: -35 60
Complete configuration: host machine sensor AC adapter connecting cable and transport case.
FRC A/D digital kilovoltmeter consists of a high stabilized resistive-capacitive type passive high-voltage divider and a precision digital voltmeter for measuring AC/DC high voltage on the site of electric power systems and in various high-voltage laboratories. Both of them with measuring cable, power supply cord, and operating manual are placed in a portable aluminium case for easy carrying and use.
The AC/DC digital kilovoltmetre is composed of two parts of a high voltage divider and a digital kilovoltmetre. The high voltage divider is of a passive resistive-capacitive type, assembled from precision low temperature drift resistors and high quility condensers. Digital kilovoltmeter consists of ture RMS value circuit, peak values measuring circuit and digital voltmeter. Voltage divider is connected to digital kilovoltmeter by a coaxial measuring cable. The high voltage is reduced to sample value by the voltage divider, and be fed to digital voltmeter. Through function selector, the voltmeter can display DC,AC effective(RMS)value, AC peak value, and AC peak/ 2 value with high measuring accuracy and convenience in use.
Product Introduction
TKJS Tan Delta Test Set is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipments in the power plants and substations. The adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.
The instrument is equipped with high voltage step-up transformer. Besides it takes security measures like zero-cross closing lightning protection etc. During the experiment different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantage of convenient and safe operation.
product names Dielectric loss tester anti-interference dielectric loss tester automatic dielectric loss tester dissimilar frequency dielectric loss tester anti-interference dielectric loss tester automatic dielectric loss tester
1. Automatic range switching fast measuring speed (3s/time)
2. Wide measuring range: 0.0001mg/cm2 9.9999mg/cm2
3. English interface
4. 480*272 (5) color touch screen
5. Can display and print out the ESDD conductivity temperature pollution class RUSCD ( reference unified specific creepage distance )
6. Temperature self-compensating auto display standard conductivity and ESDD under 20â??
7. Auto remove salt content which reduces the requirement for cleaning fluid.
8. Auto convert off line measurement value of ESDD to live line measurement value of ESDD
9. can store hundred thousand groups of testing results can export data to U disk and print out
10. single record can be browsed deleted or exported the total records can be deleted
11. Built-in 2600mAh Li-battery it is suitable for field work
Application:
TK-15 insulator distribution voltage tester is used to test string of voltage distribution of AC circuit 35-500kV insulator. Insulator distribution voltage test meter also can do all kinds of 35kV and AC voltage measurement in laboratory. It is an ideal testing meter for the safety of line operation and the auxiliary tools for live operation.
Features:
This insulator voltage distribution tester use the static structure converted the measured voltage into electric field to measure so the impedance is high.
Small impact on tested system. The measured signal is amplified by the internal process and finally directly visualized voltage value by LCD.
Operate quickly simple and clear.
Application:
TKQC type SF6 gas recovery device is an integrated recovery device. The device is composed of a recovery system a vacuum pumping system a cleaning system a storage system and a condensing system.
Features:
Adopt advanced principle and technology advanced design complete function reasonable structure simple operation.
Two-stage rotary vane vacuum pump the vacuum speed is fast and equiped with anti oil return device.
Automatically confirm and adjust the three phase power supply for electrical system.
Using the newest patented technology SF6 special instrument and valves more reliable than similar products.
The device adopts air cooling movable type and can be used without external water source.
With the development of China's electric power industry the capacitor compensation device has been unprecedentedly developed but with it the capacitor accident rate has risen sharply and there have been serious group injury accidents. In order to prevent the occurrence of parallel capacitor accidents and ensure the safe and reliable operation of the power grid State Grid Corporation has formulated the "Measures for Preventing High Voltage Shunt Capacitor Accidents". It is clearly stated that "the measurement of the capacitance of a single capacitor of a capacitor bank should be carried out on a regular basis. It is recommended to use a measurement method that does not remove the connecting wire to avoid the failure of the casing to leak due to the force of the casing caused by the disassembly and assembly of the connecting wire".
Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 "High Voltage Shunt Capacitors" DL/T840-2003 "Technical Conditions for Use of High Voltage Shunt Capacitors" and JB5346 -1998 "Series reactor" and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device.
Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data.
Application:
ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method.
Features:
Apply to all kinds of ground lead.(round bar flat bar angle iron).
Non-contact measured grounding resistance safe fast.
Without using the assistant ground rod. Without interrupting the grounding of the device under test.
With double protecting insulation.
With strong anti-interference ability and high accuracy.
Use 5# alkaline batteries convenient for users.
With the continuous update and expansion of modern technology higher requirements are put forward for the reliability of power system and high-voltage equipment. Accidents or damage of electrical equipment are usually closely related to insulation defects. Large capacity of electrical equipment high voltage structure diversification and sealing electrical equipment should be put forward a new higher requirements. With the increasing use of large-capacity equipment the insulation performance cannot be detected by ordinary megohm meter.
Power test procedures for a number of power equipment such as: cable motor generator transformer transformer high voltage switch lightning arrester and other requirements to do a series of insulation performance tests the first is to do insulation resistance test.
When testing the insulation resistance of large-capacity power equipment the insulation resistance value is related to the pressurizing time. The longer the pressurizing time is the higher the insulation resistance value is. This phenomenon is called insulation absorption phenomenon. In order to understand the insulation performance of the subject it is necessary to conduct the absorption ratio and polarization index test first so as to provide safety guarantee for the next leakage dielectric loss partial discharge and insulation performance test. According to the electric power standardization regulations our company specially introduces BC2010 Insulation Resistance Tester with large capacity high anti-interference and stable performance which can conduct Insulation absorption ratio and polarization index tests on electric power equipment providing accurate judgment in the early stage for series Insulation tests.
Product nickname Digital megohmmeter pointer megohmmeter insulating sheet Insulation Resistance Tester high voltage Intelligent Dual Display Insulation to hold Tester Insulation Resistance meter Insulation characteristics Tester high voltage megohmmeter with the function of absorbing than megohmmeter megohmmeter with polarization index function the electric shake tables electronic Intelligent Dual Display Insulation to hold Tester high-power high-voltage megohmmeter
The electrical integrity of grounding device refers to the grounding device should be between all kinds of electrical equipment grounding device parts and the electrical connectivity between each equipment that is direct current resistance value also known as electrical conductivity. Reliable and effective connection between grounding lead and ground network is the fundamental guarantee of safe operation of power equipment. Ground down lead is electric power equipment and the connection part of the network in the long running process of electric power equipment joint is likely to be affected due to factors such as moisture rust a node or even the phenomenon such as fracture lead to ground down lead and the main grounding network connection resistance increases which cannot meet the requirements of power regulation problems in the operation of the equipment in safe hidden trouble caused serious ground operation. Corrosion and even fracture may occur to the underground grounding pole and its connecting part of the grounding device. Therefore it is necessary to test the electrical integrity of ground equipment regularly.
Electric power industry standard DL/T475-2006 "guidelines for the grounding device parameters measurement regulation electric conductivity connectivity should choose special measuring instrument for 1 m instrumentresolution accuracy is not lower than 1.0 on the Richter scale are unlikely. Our company is based on this The standard developed Ground Continuity Tester is a portable Tester with a high degree of automation which is specially used to test the electrical integrity of grounding devices. Its various technical indicators meet or are superior to relevant standards. Ground Continuity Tester is a simple and convenient operation high precision fast test speed good retesting performance and intuitive reading. It is an ideal special instrument in line with the requirements of regulations which greatly facilitates the development of test projects and improves work efficiency.
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method).
Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy.
Product Introduction
TKDL-WS automatic temperature rise test system is used for manufacturers testing the high and low voltage electrical products before delivery. It provides two functions of large current and temperature test. Convenient for user operation improves working efficiency. It applies to power plant power distribution station electrical appliance manufacturing factories scientific researching institutes laboratory. Multi channel temperature recorder uses digital synchronous sampling technology with advantages of rapid test speed high precision convenient to operate good appearance.
product features Product Characteristics
1 This product is composed of large current generator voltage regulator temperature tester industrial controlling computer operation system.
2 Voltage and current displayed by industrial controlling computer software precision level is 0.5.
3 With zero position starting up protection function and emergency stop function.
4 Software test time self setting and with prompting function.
5 After current setting any deviation software can automatically adjust according to the parameters set in advance.
6 Prevent strong magnetic interference.
7 Use imported K type thermocouple: 0~1370.
8 Temperature tester with multi channel temperature monitoring measuring recording function and comparing with the test point temperature formrising temperature self alarm when the rising temperature higher than setting temperature. Any point temperatures and temperature rising value can be checked measurement error is ±1%.
9 Adopt anti interference technology combined with the hardware and software function is stable and anti-interference is strong. Four basic screens digital display picture bar chart display picture real time curve picture recall curve picture.
Product Introduction
The TKJF-208 hand-held partial discharge detector is used to detect the local discharge power supply in medium and high voltage equipment.If no discharge is detected it does not mean that there is no discharge activity in medium and high voltage equipment.Power discharges often have an incubation period and the insulation may fail for reasons other than partial discharge.If a significant discharge is detected in equipment connected to the medium-high voltage power system the equipment maintenance department should be notified immediately.
product features Product Characteristics
a) Screen display: high-contrast 3.5 TFT color screen.
b) Data storage: 1000 groups of test data can be stored.
c) Working power supply: embedded 8.4V lithium battery for 8h continuous operation.
d) Power supply: input 100-240VAC output 8.4V/3A charging time 34h.
e) Boundary dimension:230 * 120 * 55(mm).
f) Instrument weight:1.5kg.
g) Environment temperature: -25-45.
h) Storage temperature: -35-60.
Complete configuration: host machine sensor AC adapter connecting cable and transport case.
product brief introduction Product Introduction
FRC A/D digital kilovoltmeter consists of a high stabilized resistive-capacitive type passive high-voltage divider and a precision digital voltmeter for measuring AC/DC high voltage on the site of electric power systems and in various high-voltage laboratories. Both of them with measuring cable, power supply cord, and operating manual are placed in a portable aluminium case for easy carrying and use.
Product features Product Characteristics
The AC/DC digital kilovoltmetre is composed of two parts of a high voltage divider and a digital kilovoltmetre. The high voltage divider is of a passive resistive-capacitive type, assembled from precision low temperature drift resistors and high quility condensers. Digital kilovoltmeter consists of ture RMS value circuit, peak values measuring circuit and digital voltmeter. Voltage divider is connected to digital kilovoltmeter by a coaxial measuring cable. The high voltage is reduced to sample value by the voltage divider, and be fed to digital voltmeter. Through function selector, the voltmeter can display DC,AC effective(RMS)value, AC peak value, and AC peak/2 value with high measuring accuracy and
Product Characteristics
1. Dielectric strength tester for insulation oil use large capacity single-chip microcomputer control stable and reliable work
2. Dielectric strength tester for insulation oil there is the function of temperature and humidity in time clock display and is equipped with grounding alarm to remind customers pay attention to safety
3. Dielectric strength tester for insulation oil has a wide range of watchdog circuit to eliminate the phenomenon of crash
4. Multiple operating option Dielectric strength tester for insulation oil program with GB1986 GB2002 two methods of national standard and custom operation able to adapt to a variety of different users choice
5 Dielectric strength tester for insulation oil oil cup is made of a special glass casting forming to eliminate the phenomenon of oil and other interference
6. Dielectric strength tester for insulation oil special high voltage side sampling design for test values directly into the A/D converter to avoid the error caused in the analog circuit makes the measurement more accurate
7. Dielectric strength tester for insulation oil inside has over current over voltage short circuit protection and other functions and with a strong anti-jamming capability good electromagnetic compatibility
1. The software is specially designed for DC system measurement
2. Adopts ARM DSP and 16 bit Flash memory
3. Touch panel simple operation
4. Can store review the testing results or upload data into PC
5. Module structure reliable running and reasonable design
6. Menu operation easy to use
7. Software can be upgraded via U disk
8. Data can be analyzed via DC system comprehensive analysis software installed in PC
9. large LCD display user-friendly interface
10. Full automation once set the parameters it automatically adjust AC voltage load loading resistance measure parameters record testing results and stop measuring
11. Real time on line test record single cell and battery bank voltage
12. RS232 and USB communication interface
13. Powerful data processing function: curve indication report generating accurate calculating
14. Protection function auto stop or manually stop measurement
15. Three phase digital control voltage regulator with high precision high stability
16. Module assembly structure small volume little weight easy for transporting or moving
Product Characteristics
1 Compact design light weight convenient for users to carry and operate
2 Battery internal resistance tester features: single battery measurement group battery measurement oscilloscope
3 You can use the keys or touch screens
Product Parameters
Technical parameters
Measuring range internal resistance 0.0m 100m
Voltage 0.000V 16V
Minimum measurement resolution internal resistance 0.01 m
Voltage 1mV
Accuracy of measurement internal resistance ±2.0%rdg±6dgt
Voltage ±0.2%rdg±6dgt
Display 240-320 24bit 3.5-inch TFT LCD + touch screen
Dimensions 190 100 30mm3
Weight 0.5KG
Memory capacity fLASH 16 M bytes
Working power supply Rechargeable lithium battery can work for 5 ~ 6 hours at full charge
Power converter AC100 ~ 240V/ DC 8.4v-1a power adapter/The charger
Communication interface USB interface (insert U disk)
Product Introduction
DC system grounding fault tester is a new generation of tester. It can be applied to dc systems of any voltage grade. It is equipped with high-precision detection clamp table which greatly improves the detection range and anti-interference ability through efficient processing of multiple signals. Advanced algorithm and fuzzy control theory are adopted to express the superiority degree of detected insulation branch in numerical form which fully reflects the superiority of artificial intelligence. They have accurate judgment on the location of the grounding point and can point out the location and direction of the grounding point every time.
DC system grounding fault tester takes system safety as the primary premise conducts detection in a reliable low-frequency signal in strict accordance with the requirements of industry standards and carries out a large number of practical applications in the field without any impact on the system.
Dc systems in power plants and substations provide power supply for control protection signals and automatic devices. The safe and continuous operation of dc systems is of great importance to ensure power supply and distribution. As the dc system is not grounded by floating system if two-point grounding occurs it may cause the above devices to misoperate and refuse to operate thus causing a major accident. Therefore when one point grounding occurs the grounding point should be accurately and quickly detected while ensuring the normal power supply of the dc system to eliminate the grounding fault so as to avoid the possible harm of two points grounding.
DC system grounding fault tester is used to find the exact location of DC system grounding points of power plants and substations in the case of constant electricity. All kinds of grounding faults can be found out quickly with good accuracy.
Product nickname: DC Ground Fault Tester DC System Fault Tester DC System Ground Fault Tester DC System Ground Fault Tester
roduct Introduction
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge tester can be in offline mode battery as discharge load through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data.
Battery discharge tester system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access.
Battery discharge tester has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Battery discharge tester there is perfect protection function not only sound light warning but also a clear interface tips.
Application:
ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method.
Features:
Apply to all kinds of ground lead.(round bar flat bar angle iron).
Non-contact measured grounding resistance safe fast.
Without using assistant ground rod. Without interrupting the grounding of the device under test.
With double protecting insulation.
With strong anti-interference ability and high accuracy.
Use 5# alkaline batteries convenient for users.
Product Introduction
The electric power production hold detector using embedded industrial microcomputer real-time operating system digital to analog pointer and digital code display perfect combination the whole list has a variety of output voltage level (2500 v 5000 v 10000 v) strong anti-interference analog pointer and digital synchronous display ac/dc simple operation automatic save measurement results etc. It is an ideal tester for measuring insulation resistance of transformers mutual inductors generators high voltage motors lightning arresters etc.
Product nickname Digital Megabyte meter pointer Megabyte meter insulation meter digital high voltage Megabyte meter high voltage insulation resistance tester insulation resistance meter insulation characteristics tester electric shake meter electronic insulation resistance tester high voltage Megabyte meter insulation resistance tester
Product Introduction
With the continuous update and expansion of modern technology higher requirements are put forward for the reliability of power system and high-voltage equipment. Accidents or damage of electrical equipment are usually closely related to insulation defects. Large capacity of electrical equipment high voltage structure diversification and sealing electrical equipment should be put forward a new higher requirements. With the increasing use of large-capacity equipment the insulation performance cannot be detected by ordinary megohm meter.
Power test procedures for a number of power equipment such as: cable motor generator transformer transformer high voltage switch lightning arrester and other requirements to do a series of insulation performance tests the first is to do insulation resistance test.
When testing the insulation resistance of large-capacity power equipment the insulation resistance value is related to the pressurizing time. The longer the pressurizing time is the higher the insulation resistance value is. This phenomenon is called insulation absorption phenomenon. In order to understand the insulation performance of the subject it is necessary to conduct the absorption ratio and polarization index test first so as to provide safety guarantee for the next leakage dielectric loss partial discharge and insulation performance test. According to the electric power standardization regulations our company specially introduces BC2010 Insulation Resistance Tester with large capacity high anti-interference and stable performance which can conduct Insulation absorption ratio and polarization index tests on electric power equipment providing accurate judgment in the early stage for series Insulation tests.
Product nicknameï¼?Digital megohmmeter pointer megohmmeter insulating sheet Insulation Resistance Tester high voltage Intelligent Dual Display Insulation to hold Tester Insulation Resistance meter Insulation characteristics Tester high voltage megohmmeter with the function of absorbing than megohmmeter megohmmeter with polarization index function the electric shake tables electronic Intelligent Dual Display Insulation to hold Tester high-power high-voltage megohmmeter
Product Introduction
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Product Introduction
ground resistance tester rejects the traditional manual manual power generation method adopts advanced medium and large scale integrated circuit and applies DC/AC conversion technology to combine the three-end button and four-end button measurement mode into a new type of Ground Resistance meter..
The working principle is that the DC/AC converter in the machine changes DC into low-frequency constant current of AC and the circuit is formed by auxiliary ground electrode C and measured object E which generates AC voltage drop on the measured object and is fed into AC amplifier for amplification through auxiliary ground electrode P and then sent to the meter head for display through detection. With the aid of multiplying power switch three different quantity limit can be obtained: 0 ~ 2 0 ~ 20 0 ~ 200.
Didital ground resistance tester is suitable for measuring Ground Resistance of various devices and conductor Resistance of low Resistance in electric power post and telecommunications railway communication mining and other sectors; Didital ground resistance tester also measures soil resistivity and Ground voltage.
Product nickname Ground Resistance Tester Digital Ground Resistance Tester Ground contact Resistance meter Ground Resistance meter Ground pile Didital Ground Resistance Tester digital Ground Resistance meter portable Didital Ground Resistance Tester digital Ground Resistance meter Didital Ground Resistance meter Tester
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates.
1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display.
2. With computer interface improve the level of office automation and reduce the labor intensity.
3. Can have a large screen display provide a friendly operation interface and rich measurement information.
4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box.
5. Possess good catching measures and be able to promptly inform users of wrong information.
6. This automatic transformer calibration station can reach level 2.
7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.
Recommended products
Product Introduction
SMG7000 Handheld Power Quality Analyzer Input Characteristics
1. Voltage measuring range: 0~400V auto.
2. Current measurement range
3. Clamp transformers (three): 5A/25A (standard)
100A/500A (optional)
400A/2000A (optional)
4. Phase angle measurement range: 0~359.99 �°.
5. Frequency range: 45~55Hz.
6. Voltage number of channels: three channels (UA UB and UC).
7. Current number of channels: three channels (IA IB IC).
8.Maximum number of harmonic analysis: 63 times.
9. Intervals of 1 minute maximum storage period: 18 months
Product Parameter Product Parameters
Use environment:
1. Temperature: 5 -- 40 relative humidity: < 80% (25 ) altitude: < 2500m
Power frequency: 50Hz ± 0.5Hz power voltage: 220V ± 5V
2. Measurement range:
In phase component (%): 0.0001 200.0 resolution: 0.0001
Orthogonal component (min): 0.001-700.0 resolution: 0.001
Impedance (): 0.0001 20.0 resolution: 0.0001
Mobility (MS): 0.0001 20.0 resolution: 0.0001
3. Basic error:
In phase component: �? x = �± (x �? 2% + y �? 2%) �± DX (with level 1 option)
Orthogonal component: y = ± (x 2% + y 2% 34.48) (Level 1 optional)
"X", "Y" - display value of the instrument
"DX, Dy" - quantization error of instrument Dx = 2, Dy = 5
4. Dial indicator: level 1.5 (optional level 1)
Scope of work:
1. Current: (1% - 149%) in (in = 5a)
5% 149% In In =1A
2. Voltage: (5% - 149%) UN (UN = 100V, 150V, 100V / 3)
Product Introduction
Transformer Tester is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARMadvanced manufacturing technology ensure a stable and reliable product performance full-featured high degree of automation high efficiency in the domestic leading level they are the professional testing equipments for transformer check in power industry.
Product names CT parameter analyzer CT analyzer frequency CT analyzer CTPT analyzer transformer tester frequency transformer characteristic tester transformer transient characteristic analyzer current transformer tester CT characteristics analyzer current transformer current transformer parameters analyzer features analyzer CT parameter tester tester current transformer current transformer parameters characteristics tester Comprehensive instrument for the transformer
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Characteristics
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;
2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;
4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
Dc resistance tachometer is an indispensable test project for transformer after handing in pick up overhaul and change sub-pick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce the work burden of test personnel huatian electric power developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). Dc resistance tachometer adopts new power supply technology featuring stable performance rapid measurement compact volume easy to use High measurement precision and good data repeatability. Measurement transformer around the group and large power inductor dc resistance ideal equipment.
Dc resistance tachometer meets the requirements of DL/ t845.3-2004 with national standard gb6587-86 "general outline of environmental test of electronic measurement instrument" and gb6593-86 "test rules of electronic instrument quality".
Product Introduction
TKJS Tan Delta Test Set is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipments in the power plants and substations. The adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.
The instrument is equipped with high voltage step-up transformer. Besides it takes security measures like zero-cross closing lightning protection etc. During the experiment different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantages of convenient and safe operation.
This instrument use high accuracy (1uA) leakage test and updated CT shielding technology. It is composed of special HV detector and HV insulation rod. It can wireless transmit testing data within distance of 30m.
1. The full realization of the zinc oxide arrester online uninterruptible power test.
2. The latest CT and shielding technology.
3. No lightning counter can test the zinc oxide arrester leakage current.
4. Completely solve the 6-10kV zinc oxide arrester test problems.
5 without climbing pole without wiring fast and accurate test.
6 can accurately detect the leakage current of 10uA.
7. Zinc oxide surge arresters or aging judgment online.
8. High-speed sampling frequency advanced digital signal processing technology anti-jamming performance high accuracy measurement results.
9. Optional configuration with battery especially suitable for power occasions.
10. Small size light weight easy to carry.
This instrument is carefully designed and developed by the relevant technical personnel of our company according to the needs of power users. The product is beautiful in appearance and easy to carry and use. It replaces the traditional bulky test instruments and test methods and is very popular among professionals.
1. Small size and light weight.
2. The measurement process is safe and fast and the measurement result is accurate.
1. Wide range of measuring voltage can test up to 1000G (Max 2000G) insulation resistance
2. Three and a half bit LCD digital display of insulation resistance value
3. automatically shift resistance measuring range
4. environment temperature can be measured
5. self-clocking function short buzz every 15 seconds
6. automatically calculate and save R15S R60S R600S DAR and Polarization Index
7. Output short-circuit current larger than 5mA (meet fast charging request to capacitive load)
8. strong anti-interference ability stable and reliable reading
9. perfect protection safe for operation
10. powered by rechargeable Li-battery auto power off when battery energy is not enough
1.Overview:
Transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The acid value is the trace value of potassium sulfate that neutralizes the petroleum acid in 1g of oil, which contains a certain amount of inorganic acid and inorganic acid. The acid value includes organic and inorganic acids contained in the oil. In most cases, oil does not contain mineral acids. Therefore, the oleic acid value actually represents the content of organic acids in the oil. The organic acid contained in the new oil is mainly cyclonic acid. In the oil and in the process of use, the acid value of the oil produced by oxidation is an indicator to measure the degree of refining of the new oil. Whether the oil is running is an important indicator of the continued use of oil quality equipment.
2. Technical index:
1.Test range: 0.00 1mg KOH/g
2.Test error: ±0.005mg KOH/g
3.Repeatability: 0.005mg KOH/g
4.Ambient temperature: 10-45
5.Relative humidity(RH): 85%RH
6.Voltage supply: AC220V/50Hz
7.Power: 50W
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.
Technical index
Oil cup technical specifciations:
Distance between High Voltage terminal
and Low Voltage terminal 2mm
Capacitance of Empty Cup 60±2PF
The Highest testing voltage Industrial Frequency 2000V
Dielectric Loss of Empty Cup tg 10-4
Liquid capacity About 40ml
Electrode Material Stainless Steel
Volume 70mm(D) 120mm H
1
Condition of Use
-5-40 RH 80%
2
Power Source
AC 110V±10% Without Frequency Limit
3
AC High Voltage Output
400V 2200V ±2% Every 100V 50VA
4
DC High Voltage Output
200V 600V ±2%
5
Temperature Control Induction Stove
Maximal Power 500W
6
Temperature Control Range
Product description
The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple.
Main technical indicators and conditions of use
Measurement accuracy: voltage, current: 0.2 level
Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade
Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade
Voltage measurement range: AC 3V300V
Internal power output range: voltage 0~250V, current 0~10A
Current measurement range: AC 0.2A 20A
Working temperature: -10-50
Working humidity: 80%
Working power supply: AC220V ±10-50Hz ±1Hz
Dimensions: 360mm 220mm 150mm
Weight of the instrument: 20Kg
Overview
Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB/T507-2002, industry standard DL429.9-91 and the latest Electric Power Industry Standard DL/T846.7-2004 by ourselves. This instrument, by using a single-chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.
Major Technical Indicators
1. Output voltage: 0-100KV (optional)
2. Voltage distortion rate: 3%
3. Voltage raising speed: 0.5-5 KV/S (adjustable)
4. Standing time: 15min (adjustable)
5. Boosting interval: 5 min (adjustable)
6.Boosting frequency: 1-9 time(s) (optional)
7. Booster capacity: 1.5KVA
8.Measuring accuracy: ±3
9. Supply voltage: AC220V ±10%
50Hz±1 Hz
10. Power: 200W
11.Applicable temperature: 0-45
12.Applicable humidity: 75%RH
13. Overall dimension: 465 385 425
Introduction
AC transformer ratio tester is an innovative product are mainly applied to change than group test transformer, PT and CT polarity test, test speed, high accuracy.
Technical Indicators
Working power supply
AC220 ±10% 50/60 HZ
Instrument weight
3.8 kg
Instrument dimension
325 mm L 225 mm W 125 mm H
Use of temperature
-10-50
Relative humidity
90% No dew
Functional Characteristics
It has the function of blind measurement, that is, to perform variable ratio and group test when there is no connection between high and low voltage.
Based on the test of conventional transformer, Z-type transformer and PT sample, the polarity test function of CT variable ratio is added, and the application field is wider
Wide range and high accuracy, the variable ratio measurement range can reach 10,000, and the test accuracy can be guaranteed 0.3% when the maximum value is 10,000.
It has perfect protection functions such as reverse connection protection and output short circuit protection.
Description
Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor (Power generator) No-load test, Short circuit test, Motor excitation step response test, motor excitatory de-excitation test, motor load rejection test and grid synchronous connection test and also on
Technique index ~200V, -400V~400V and -20mA~20mA. Users can switch the input range from software. Also there is one channel -100mV~100mV which allow the input signal less than 10V.
2. The voltage and current input range assured errors are as follow:
-400V~ 400V assured error less than 0.5V
-200V~ 200V assured error less than 0.2V
-10V~ 10V assured error less than 0.01V
-20mA~ 20mA assured error less than 0.02mA
-100mV~ 100mV assured error less than 0.2mV
3. There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V.
4. There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V/1A.
5. There are 2 USB port used for data export and mouse/keyboard input
6. The LCD is 12.1 inches touch pad input mode. Make the human interface more simple.
7. The saved space in the tester is 32G for standard configuration
8. Input resistances for different channels are as follow:
-10V~10V Range Input resistance is 820K
-200V~200V Range Input resistance is 820K
-400V~400V Range Input resistance is 820K
-20mA~20mA Range Input resistance is 820K
-100mV~100mV Range Input resistance is 10M
9. Power supply AC 220V 10% 45Hz-65Hz
Overview
The Intelligent dielectric loss tester also applies to the measurement of tg and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes.
It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg´ of capacitor voltage transformer and capacitance of main capacitor C1and C2.
Main Specifications
Control panel printer, keyboard, indicator and communication transferring.
Variable frequency power supply SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage.
Step-up transformer the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA one minute.
Standard capacitor internal Cn. It is the measuring basis.
Cn current detection it is used to detect the internal standard capacitor current, 10A 1A. The input resistance is
Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. .
The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits
Nearly the resistance tester is suitable for measuring the electrical resistance of low resistance of various departments such as various devices and power postal railway communication mining; Nearly the ground resistance tester also measures soil resistivity and ground voltage.
Technical parameters
Working Conditions Ambient temperature 0+45
Relative humidity 85%RH
Measurement range and constant
current value (effective value)
Resistance 020(10mA)2200(1mA)202000(0.1mA)
Voltage AC019.99V
Measurement accuracy and resolution Precision rowspan 0 0.23%1d
Overview
Cable check and cable, cable lookups are a bit a bit of arbitrary wiring (no need to publicly line). It can greatly improve the construction progress, which is a new test tool in on-site construction such as electricity, telecommunications, automation control.
The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate.
Technical parameter:
Parameter Display the maximum row of LEDs 1000 the maximum distance of the quilt is 40km / 1.5ma
size Transmitter Size: 135 * 70 * 24MM Receiver Size: 135 * 70 * 24mm
Function
1. The entire instrument consists of a transmitter and a receiver;
2. There is no need to determine the public line to make it easy to use;
3. Wire recognition, distribution, application to a part of the wire or multi-heeled wire;
4. One item can be identified, if you need to distinguish more wires can measure or use multiple instruments;
5. Can determine whether there is a short circuit or disconnect between the wires;
6. The receiver is also a disconnect detector that can be used to measure whether the wire is turned on;
7. The structure is small and easy to operate.
Overview
Hand-held transformer turn ratio tester is an innovative product with compact size, hand-held operation, more portable and easy to carry.
Technical index
Range
0.9 10000
Accuracy
Introduction
AC transformer ratio tester is an innovative product are mainly applied to change than group test transformer, PT and CT polarity test, test speed, high accuracy.
Technical Indicators
Working power supply
AC22050/60 HZ
Instrument weight
3.8 kg
Instrument dimension
325 mm L 225 mm W 125 mm H
Use of temperature
-10 50
Relative humidity
90 No dew
Functional Characteristics
It has the function of blind measurement, that is, to perform variable ratio and group test when there is no connection between high and low voltage.
Based on the test of conventional transformer, Z-type transformer and PT sample, the polarity test function of CT variable ratio is added, and the application field is wider
Wide range and high accuracy, the variable ratio measurement range can reach 10,000, and the test accuracy can be guaranteed 0.3% when the maximum value is 10,000.
It has perfect protection functions such as reverse connection protection and output short circuit protection.
AC transformer ratio tester
Packaging Content
Standard accessories
1 transformer turn ratio tester
1 sets of test lines (red and black each)
1 power cord
1 print user manual
1 copy of certificate and factory test report
Product Introduction:
Arrester Discharge Counter Calibrator is used for discharge action logger inspection and verification of discharge counter in valve-type arrester including silicon carbide common valve type (FZ and FS), silicon carbide magnetic blow valve-type (FCZ and FCD) and zinc oxide arrester.
It is used to verify the reliability of various lightning arrester counter actions. The reliability of the counter action is very important to the power system. It is an important parameter to record the number of lightning strikes by the lightning arrester in normal operation. It can provide the staff of the power system with an important basis for the targeted inspection of the arrester. This instrument is mainly used for high-voltage arresters above 35kV.
Product Parameters:
1.Ambient temperature
2.Relative humidity
3.atmospheric pressure:86 106kPa
4.Discharge test voltage: 2kV
5.Charge time: 1 minute
Functional characteristics
Transformer capacity and no-load tester Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses, capability.
Main technical parameters
Capacity measuring range : 30kVA 31500kVA
Current measuring range: 0 -100A auto-switch the measurement range
Current measurement accuracy: (0.2% + 3digits)
Voltage measurement range: Line Voltage0-750V;phase voltage 0-450V, auto-switch the measurement range
Voltage measurement accuracy: (0.2% + 3digits)
Insulation resistance:
Leakage current:
Product Introduction:
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL/ t506-2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.
This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.
Technical Parameters:
Product description
SF6 3in 1Comprehensive SF6 Analyzer can be used to measure the purity of the product, the product will be used to achieve the function of two instruments to achieve a single instrument. A field survey, the most complete two indicators of detection, greatly save the gas in the device, a measure to save 1/2 gas consumption, while reducing the user's workload, improve the work efficiency.
SF6 gas comprehensive tester Purity analyzer Technical index
SF6 Purity (optional)
Measurement range
Precision
SF6 Decomposition
Measuring gas type and range
CO: 0-1000ppm
Sensitivity
0.1ppm
Response time
Sampling
Built in regulator valve, filter, electronic flow meter
Working power source
AC / DC, built-in large capacity rechargeable battery, full of continuous working hours
Weight
About 3.5kg
SF6 gas comprehensive tester Purity analyzer
The product can be broken down, the purity measurement in one. A measurement can be completed a number of indicators.
The full import of precision dew point measurement sensor, automatic zero calibration, anti oil, anti drift.
The electronic flow display, power display.
The file system support, data storage, printing.
The instrument is a self diagnostic function, intelligent power display.
Overview:
Generator Rotor AC Impedance Testing Instrument is a special instrument for determining whether the turn-to-turn short circuit exists in the generator rotor winding, and can manually and automatically (unidirectionally or bidirectionally) measure many parameters of the generator rotor such as voltage, current, impedance, power and rotating speed.Generator Rotor AC Impedance Testing Instrument is the latest enhanced AC impedance tester launched by our Company. The instrument adopts the state-of-the-art high speed microprocessor technology with more powerful functions, preferable performances and more convenient use. The Tester has a series of characteristics such as high reliability, easy operation, high test precision, being compact and lightweight and etc., and currently is in the domestic leading level.
Major Technical Indicators
Temperature:
Relative Humidity: 0 1% FS+2d
0.1 0.5% FS+2d
Frequency 40-75HZ 0.2%
Weight 5kg
Product description
The Single-phase capacitance and inductance tester is specially developed for the problem of measuring the capacitance value of the capacitor on the substation.
Technical parameters
Instrument measurement range and accuracy:
a. Capacitance measurement
(1) Measurable capacitance range
(2) Measurable capacity range
(3) Measurement accuracy
(4) Resolution
b. Current measurement
(1)Current measurement range
(2)Measurement accuracy
(3)Resolution: 0.01A
c. Inductance measurement
(1)Inductance measurement range:
small inductance mode 0.1mH 5mH
large inductance mode 5 mH 50H
Product description
Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Feature
1. Current clamp and meter combined together, colorful and touch-screen display;
2. One AAA Li-battery can continuously working 4 hours;
3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A;
4. Display all the measuring parameters in one screen;
5. Current clamp has automatic compensation function, 0.2% class accuracy;
6. Current clamp has automatic calibration function;
7. Integration design of the meter and clamp;
8. 16bit high accuracy AD switch 32 bit ARM processor core.
9. Automatically record and save 999 groups calibrate data;
10. Micro-multifunction optic sampler
Technical index
1. Manual/automatic test inductive single phase meters;
2. Manual/automatic test electric single phase meters;
3. Measure virtual value of alternating voltage (15 300Vrms);
4. Measure virtual value of alternating current (50mA 120Arms);
5. Test parameters: active power, phase angle of voltage and current, frequency and etc;
6. Automatic store testing data, and 999 group test results can besaved.
Product description
The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source.
Technical index
Electrical parameters
Accuracy class
0.05%, 0.1%
Power Supply
One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range
57.7V, 100V, 220V, 380V; max 500V
Adjustment range
(0-120)%RG(1)
Adjustment
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
0.01%/120s
Electrical parameters - continued
Distortion 0.2% (Non-capacitive load)
Output load max 25VA
Measuring accuracy 0.05%RG
AC Current Output
Range 200mA, 1A, 5A, 20A, 60A(100A) optional; max 120A
Adjustment range (0-120)%RG
Adjustment 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
Product Introduction
Insulation resistance tester dedicated to the measurement of water-cooled generator test but also can be used for laboratory or field testing insulation testing to do. Output current greater than 25mA. The maximum output voltage of 2500V. Includes high-precision micro-current measurement system digital boost system. Just use a high-voltage lines and a signal line connecting the test product can be measured. Automatic measurement the results from the large screen liquid crystal display and store the results.
Product Characteristics
First the main features
1. 32-bit micro-controller Chinese user interface easy to operate.
2. Automatically calculates the absorption ratio and the polarization index and automatically save 15 seconds 1 minute 2 minutes 10 minutes to facilitate analysis of data per minute.
3. Output current (2500V the output is greater than 25mA) short-circuit currents greater than 40mA.
4. A fully enclosed high-voltage generator module technology the protection of the internal resistance safe and reliable.
Anti-interference ability to meet the EHV substation on-site operation.
5. Automatic discharge test is completed and real-time monitoring the discharge process.
Product Introduction
Dc resistance around the group of measurement transformer is a very important test project. In the "test regulations of electric power equipment" its order ranks the second in the transformer test project. The "regulations" stipulates that pick up overhaul minor repair change sub-pick up head position fault check and pre-test etc. should be done in transformer. Measurement transformer must have dc resistance around the group whose purpose is:
(1) check the welding of line and lead line around the group;
(2) check if the pick up touch is good;
(3) check whether there is a broken place around the group or leading line;
(4) check the correctness of the parallel branch whether there is a few parallel guide lines winding into the winding group or a few broken line situation;
(5) check whether there is a short circuit between layers and turns.
The interface design of Dc resistance rapid test instrument adopts microcomputer control big screen backlit Chinese liquid crystal screen show operation is simple show clear man-machine interaction interface friendly measurement process and instrument work state prompt is clear and sufficient no operation personnel need to memorize too many procedures; Huatian electric power adopts current source line-based compensation technology with stable test high measurement precision and fast speed improving measurement efficiency and reducing work intensity of operation personnel. Technically "four-end" measurement is adopted to eliminate the measurement error caused by line resistance with pick up contact. Overvoltage protection function can resist electric potential impact. Panel printer can print measurement results quickly (selected). Small size light weight easy to carry.
Dc resistance rapid test instrument is applicable to measurement with analysis of various electric transformer transformer winding group and other perceptual low resistance.
product names Dc resistance tachometer Transformer dc resistance test instrument Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance rapid test instrument
Product Introduction
Direct resistance test apparatus is an indispensable experiment project for transformer after handing in pick up overhaul and sub-pick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce the work burden of test personnel huatian electric power developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small volume easy to use high measurement precision and good data repeatability. Measurement transformer around the group and large power inductor dc resistance ideal equipment.
Direct resistance test apparatus meets the requirements of DL/ t845.3-2004 with national standard GB6587 "general outline of electronic measurement instrument environmental test" and GB6593 "test rules of electronic instrument quality".
product names Dc resistance tachometer Transformer dc resistance test instrument Transformer winding dc resistance test instrument Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Direct resistance test apparatus
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement.
1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ;
2. High Anti-interference ability accurate and reliable measurement;
3. Easy operation equipped with large LCD and American rotating mouse and micro printer
4. Simple wiring only connecting with tested down leads to finish all line parameter measurement
5. High speed micro-controller as inner core integrated structure
6. Fast testing process one sequence parameter testing time is 1 min
7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
This instrument is an instrument which is specially used for transformer loss parameters and line frequency parameters testing. The instrument has the advantages of ingenious design excellent performance and powerful functions. The interior adopts advanced multi A/D synchronous sampling and digital signal processing technology and successfully solves the problem of multi-channel signal synchronous measurement and calculation. The instrument adopts large screen liquid crystal display Chinese menu prompt simple operation equipped with high-speed thermal printer and has storage function convenient for data storage and printing. The instrument is small in volume light in weight easy to carry and is very convenient to use in the field. It greatly reduces the labor intensity of the experimenters and improves the working efficiency.
1. Large LCD display simple menu operation.
2. With thermal printer storage function.
3. Small volume and light weight suitable for field work.
Product Overview
Adapts advanced technology TKGX Underground Cable Detector is the most effective device to detect underground utilities of gas electric power telecom water supply drainage cable television and etc.
Features
Portable designation suitable for wild field testing.
Full digital control easy to control.
English graphic display.
Transmitter designed with over load and overheating protection.
To detect the location and depth of underground cable accurately also is available for branch pipe or network construction underground cable.
Two detect methods: AC current gradient method and ground electric field method.
To locate and detect depth of underground cable synchronously.
Product Overview
TKDL Cable Identifier is designed to identify a special one within a group of cables during the power cables setting up moving maintaining and faults processing. It suitable for all kinds of HV & LV cables.
Features
Can identify energized or de-energized cable.
The system is composed by signal transmitter receiver transmit clamp receive clamp and some connection leads.
Large power current pulse output.
On-site receiving signal is clear.
Light weight high sensitivity and anti-interference ability.
To identify needed cable with or without electric.
Accurate and fast identifying.
Reliable protective circuit.
Large diameter clamp suitable for all kinds of section surface cable.
Build-in large power insulated transformer there is no any electrical contact between mains supply and user.
1. Small size lightweight
2. High voltage generated by electronic circuit powered by battery only need one operator
3. Digital display accurate measurement intuitive and stable display
1.Test voltage: 5000V DC
2.Range: 0-1999M
3.Resolution: 1M
4.Basic error: ±5%
5.Power supply: one cell 9V layer-built battery
6.Power source current: about 20mA
7.Environment temperature: 0-40
8.Environment humidity:85%
9.Dimension: 120x70x50mm
Application:
TKQH-SF6 Series vacuum pumping and inflation device is mainly used for vacuum pumping and vacuum degree determining of magnetic pole SF6 circuit breaker transformer and other SF6 electric appliances when installation operation and maintenance. The entire SF6 gas inflation and vacuum pumping device comprises a vacuum pump a pointer type vacuum gauge a regulating valve a gas transmission pipe and a valve and SF6 circuit breaker necessary control components for maintaining.
Features:
Quick pumping.
Regulate pressure to inflate.
Solid structure.
High precision thermocouple vacuum gauge.
Application:
TKWS Intelligent SF6 dew point analyzer introduced Finland Vaisala humidity sensor with high precision and high stability. It has the advantages of high accuracy and good repeatability fast test speed small drift.
Features:
Easy to operate convenient to carry.
Unique large screen display and large storage function.
Anti pollution anti interference.
Good repeatability quick response high sensitivity and good stability.
Origination of curve display and electric quantity display.
conversion to 20 standard value.
SF6 switch is a widely used high voltage electrical appliance in the power system. SF6 gas density relay is an important element used to monitor the variation of SF6 gas density in the SF6 switch body during operation. Its performance directly affects the operation safety of SF6 switch.Due to the infrequent operation of SF6 gas density relay in the field it is often found that the operation is not flexible and the contact contact is not good after a period of time and some of the temperature compensation performance of the density relay becomes worse. When the ambient temperature changes suddenly the SF6 density relay often misoperates.Therefore DL/T596-2005 "precautionary test regulations for power equipment" stipulates that each SF6 switch user should verify SF6 gas density relay regularly.From the perspective of actual operation it is necessary to carry out regular calibration of SF6 density relay and pressure gauge in field operation.
The check pressure sensor with high precision and high speed A/D converter combining with the 32 bit high performance microprocessor can check the performance of A variety of SF6 gas density relay can accurately measure the movement of the signal when the current temperature pressure value arbitrary automatically when the environment temperature of 20 â?? conversion standard pressure and have A print store and U disk offload function at the same time the fault in the process of automatic identification test.Sf6 gas density relay calibrator is convenient to carry simple to operate high test accuracy strong stability and good reliability which reflects the characteristics of "intelligent" instrument.
The intermolecular forces form the interfacial tension or surface tension of the liquid. The value of the tension can reflect the physical and chemical properties of the liquid and its material composition. It is one of the important indicators for the inspection of product quality in related industries.Automatic statically tester manufactured by our company applies GB/T6541 standard and measures the surface tension of various liquids (liquid-gas phase interface) and liquid interface tension (liquid-liquid phase interface) based on the ring method (platinum ring method).This method is widely used because of its advantages of simple operation and high accuracy.Widely used in electric power petroleum chemical pharmaceutical food teaching and other industries.
TKYND full-automatic full-automatic kinematic viscosity tester is a new product newly launched by our company which is used to determine the kinematic viscosity of petroleum products. It is applicable to the national standard GB/T 265-1988. This instrument combines the advantages of our company and the original similar products at home and abroad carries out a new design concept is the older generation of kinematic viscosity tester replacement products.
Product Names kinematic viscosity meter automatic kinematic viscosity tester determination of kinematic viscosity meter automatic kinematic viscosity meter
In power system and industrial and mining enterprises have a lot of oil-filled electrical equipment transformer oil and the acid value of turbine oil is a routine inspection items shall be measured acid tester used in transformer oil steam turbine oleic Acid value measuring instrument adopt computer control electric light chemical integration design of full - automatic machine entirely replace the manual operation improve work efficiency reduce the labor intensity of the workers minimize the organic solvents and chemicals to the harm of human body operation simple easy to use strong anti-interference ability stable and reliable.
The acid value is the number of milligrams of potassium hydroxide required to neutralize the acid in a gram of mgKOH/g oil and is one of the most tightly controlled quality indicators It is one of the indexes which should be strictly controlled in oil quality. Petroleum products acid tester GB/T264-83Standards developed and produced It is suitable for detection transformer oil turbine oil and anti - fuel oil.Through the comprehensive application of mechanical optics electronics and other technologies the product adopts advanced microprocessor and can realize self-motion function of multi-sample switching titration judge titration end point print measurement results and other functions and the system is stable and reliable self-motion high degree of chemical can be widely used in electric power chemical environmental protection and other fields.
Automatic Closed Flash Point Tester used to measure the Closed flash point value of petroleum products.Advanced foreign technology is adopted. LCD TET's pure color touch screen displays the man-machine dialogue interface in Chinese. For parameters such as prevalue temperature oil test label atmospheric pressure and test date it has prompt menu prompt input which is convenient and fast.It is an ideal substitute for imported instruments.Widely used in railway aviation electric power petroleum industry and scientific research departments.
1. The software is specially designed for DC system measurement
2. Adopts ARM DSP and 16 bit Flash memory
3. Touch panel simple operation
4. Can store review the testing results or upload data into PC
5. Module structure reliable running and reasonable design
6. Menu operation easy to use
7. Software can be upgraded via U disk
8. Data can be analyzed via DC system comprehensive analysis software installed in PC
9. large LCD display user-friendly interface
10. Full automation once set the parameters it automatically adjust AC voltage load loading resistance measure parameters record testing results and stop measuring
11. Real time on line test record single cell and battery bank voltage
12. RS232 and USB communication interface
13. Powerful data processing function: curve indication report generating accurate calculating
14. Protection function auto stop or manually stop measurement
15. Three phase digital control voltage regulator with high precision high stability
16. Module assembly structure small volume little weight easy for transporting or moving
Battery internal resistance tester adopts the most advanced ac discharge test method which can accurately measure the voltage and internal resistance at both ends of the battery and judge the advantages and disadvantages of the Battery capacity and technical state.Customers can choose battery internal resistance test voltage test capacity estimation according to their own situation.As the basis for matching the internal resistance of new batteries;Test the battery internal resistance before and after discharge to identify the real backward battery;Key operation and liquid crystal touch two operation mode;It can measure the accumulator in groups or in a single section.
1 Compact design light weight convenient for users to carry and operate
2 Battery internal resistance tester features: single battery measurement group battery measurement oscilloscope
3 You can use the keys or touch screens
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge tester can be in offline mode battery as discharge load through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data.
Battery discharge tester system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access.
Battery discharge tester has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Battery discharge tester there is perfect protection function not only sound light warning but also a clear interface tips.
With the development of China's electric power industry the capacitor compensation device has been unprecedentedly developed but with it the capacitor accident rate has risen sharply and there have been serious group injury accidents. In order to prevent the occurrence of parallel capacitor accidents and ensure the safe and reliable operation of the power grid State Grid Corporation has formulated the "Measures for Preventing High Voltage Shunt Capacitor Accidents". It is clearly stated that "the measurement of the capacitance of a single capacitor of a capacitor bank should be carried out on a regular basis. It is recommended to use a measurement method that does not remove the connecting wire to avoid the failure of the casing to leak due to the force of the casing caused by the disassembly and assembly of the connecting wire".
Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 "High Voltage Shunt Capacitors" DL/T840-2003 "Technical Conditions for Use of High Voltage Shunt Capacitors" and JB5346 -1998 "Series reactor" and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device.
Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data.
Product nickname: automatic capacitance and inductance tester referred to as
1.Strict accordance with the safety standards for design with 5 range: 500V 1000V 2500V 5000V 10000V test up to 10T�©.
2.This instrument has the function of automatic calibration and calibrate precision automatly before test
3.Actual test object live voltage measurement functionmeasure leakage currentdischarge automatly.
4.automatic measure and remenber R15Sã??R60S ã??R10min valueAutomatic display polarization index (PI) induced electric absorption test values than (DAR)and test time.
5.Anti-jamming performance is superior the interference current reaches 600 mA still ensure accuracy of test instruments.
6.Automatic discharge:quickly discharge for capacitive test object by advanced high-voltage discharge technology and real-time measurement of discharge voltage (test voltage to 0v) .
7.powered by internal rechargeable lithium battery or ac power supply the real ac and dc dual use does not affect the test accuracy.
8.digital displayautomatic display battery level and undervoltage alarm protection function.
9.Short circuit protection short circuit condition will not burn out the instrument
Product Introduction
Transformer Tester is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARMadvanced manufacturing technology ensure a stable and reliable product performance full-featured high degree of automation high efficiency in the domestic leading level they are the professional testing equipments for transformer check in power industry.
Product names CT parameter analyzer CT analyzer frequency CT analyzer CTPT analyzer transformer tester frequency transformer characteristic tester transformer transient characteristic analyzer current transformer tester CT characteristics analyzer current transformer current transformer parameters analyzer features analyzer CT parameter tester tester current transformer current transformer parameters characteristics tester Comprehensive instrument for the transformer
Product description;
The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester [MOA] leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's Republic of China DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests.
Zinc oxide arrester tester Technical Indexes:
Range of reference voltage input (peak): 10V-200V
Measurement range of full leakage current (peak): 100uA-10mA
Measurement range of resistive current (peak): 100uA-10mA
Measurement range of capacitive current (peak): 100uA-10mA
Measurement range of angle: 0·-90
Power consumption: 4W
System measurement accuracy: ± (reading 5% + 5 words) (not more than 2mA for harmonic current)
Send InquiryCHAT NOW
Product Details
Product description
Intelligent loop resistance tester is ergonomically designed, in line with operating practices, use high-frequency switching power supplies and digital circuit technology for measuring the contact resistance of the circuit switch control device. Test current is DC 100A. In the case of DC 100A can be directly measured contact resistance test result with a large-screen LCD display, and with data storage, print, time settings and other functions, and another gear 50A for user selection; custom test time, maximum 599S, much larger than the standard requirements of 60S; resolution 0.01 and very stable. Meet the power; the electricity sector on-site high voltage switch maintenance and high-voltage switch factory contact resistance testing requirements.
Technical index
1. Measurement range: 0-2999.9
2. Resolution: 0~99.99, 0.01
100.0~2999.9, 0.1
3. Measured current: DC 50A, 100A, fixed output.
4. Accuracy :±(0.5% rd+2d)
5. Continuous working time: 5s~599s
6. Display :LCD
7. Communication mode: USB
8. Power supply: AC220V±10% 50Hz
9. Power of the whole machine:600W
10. Maximum storage record: 200
11. Service conditions: temperature- 10â??ï½?40â?? humidityâ?¤80 %RH
12. Dimension: 360 300 250 mm3
13. Weight: 8kg (the accessories not included)
Product description
Transmission Line Parameter Test System is of an integrated structure, with a built-in variable frequency power supply module and a variable frequency voltage regulating output power supply. The frequency can be changed to 45Hz and 55Hz. Digital filtering technology is adopted to avoid the interference of power frequency electric field to the test and fundamentally solve the difficult problem of accurate measurement under strong electric field interference. At the same time, it is applicable to the occasions where the generator is used for power supply detection after all power outages.
Technical index
1 Utilization Conditions -20 50 RH 80%
2 Anti-interference Principle Frequency variation method
3 Power Supply AC220V±10% Generator 3KW
4 Power Output Max.output voltage AC300V
Voltage accuracy 0.5%
Current accuracy 0.5%
Max.output current 8A
Output frequency 45Hzã??55Hz
Interference Current 30A
Resistance to Induced Voltage 10KV
Memory Size 200 groups Support U Disk Data Storage
Weight 67 Kg
Send InquiryCHAT NOW
Product Details
Product description
This cable fault tester is a comprehensive set of cable fault detection equipment. It can be used to detect flash-over cable fault, the earthing of the resistance, short circuit , cable break, and poor contact, with acoustic instrument, the exact location of the fault can be accurately detected. This tester is particularly suitable for testing voltage power cables and communication cables in various models and different levels
Applications and Uses
This tester can test various types of power cables (voltage 1KV ~ 35KV) and telephone cable, FM communication cables, coaxial cables, and the short circuit on the metal overhead cables, grounding, high resistance leakage, high impedance fault flash-over ,cables disconnection, and poor contact fault; and it can also test the length of the cable and the waveform transmission velocity.
Product description
The portable search instrument of DC ground fault designed and manufactured by our company can apply to DC system of any voltage class. It is equipped by clamp meter of high-precision, which greatly expanded detection range and enhanced capacity of resisting disturbance through efficiently disposing various signals. It employed advanced computing method and fuzzy control theory and can manifest insulating degree of the detected circuit in the form of insulation index and wave, which fully reflects the advantage of artificial intelligence. It has precise judgment for deciding ground point. It can point out the direction of relative detecting point of ground point, thus accomplish ground detection of loop circuit rapidly and precisely. Beyond that, users can order instrument with appropriate insulation alarm threshold value within the range of insulation alarm threshold value based on the need of own system. Users can accomplish the detection of DC ground and analysis of insulation degree by matching the tap position of clamp meter with the measuring range of detecting instrument.
Overview:
Underground fault cable locator Consisting of the transmitter, receiver, magnetic induction wand, location detection frame and other components, This instrument is a special instrument cable, cable fault location test for the test object is a metal conductor (wire pairs, sheath, shield) of a variety of fiber optic cable. Its main function is to locate bad insulation test points, probe and cable depth testing cable path.
Main Technical Parameters:
Tracing positioning distance: telephone cable is around 3km, other cables are up to 20km
Positioning impedance range: 0-5M
Positioning accuracy:
Product Introduction
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area.
Product Characteristics
1. With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
2. The short-circuit current of test power> 5mA, maximum up to 15mA. Be suitable for testing high capacity and high inductance.
3. Wide resistance range from 0.5M�© ~ 200000M�©. With high-resolution, having accurate readings.
4. Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV, you can smoothly adjust voltage from 0V to the desired value.
5. With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.
The electric power production hold detector using embedded industrial microcomputer real-time operating system digital to analog pointer and digital code display perfect combination the whole list has a variety of output voltage level (2500 v 5000 v 10000 v) strong anti-interference analog pointer and digital synchronous display ac/dc simple operation automatic save measurement results etc. It is an ideal tester for measuring insulation resistance of transformers mutual inductors generators high voltage motors lightning arresters etc.
Product nicknameï¼?Digital Megabyte meter pointer Megabyte meter insulation meter digital high voltage Megabyte meter high voltage insulation resistance tester insulation resistance meter insulation characteristics tester electric shake meter electronic insulation resistance tester high voltage Megabyte meter insulation resistance tester
Product Introduction
Designed for automatic testing of protective and metrological CT/PT suitable for laboratory and field testing.
The product names PT volt-ampere characteristic tester transformer volt-ampere characteristic integrated tester CT voltage-current characteristic integrated tester CT voltage-current characteristic tester PT volt-ampere characteristic tester transformer volt-ampere characteristic tester volt-ampere characteristics of variable polarity than integrated tester volt-ampere characteristic tester volt-ampere characteristics integrated tester volt-ampere characteristic tester features comprehensive tester
Transformer Tester is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARMadvanced manufacturing technology ensure a stable and reliable product performance full-featured high degree of automation high efficiency in the domestic leading level they are the professional testing equipments for transformer check in power industry.
Product names CT parameter analyzer CT analyzer frequency CT analyzer CTPT analyzer transformer tester frequency transformer characteristic tester transformer transient characteristic analyzer current transformer tester CT characteristics analyzer current transformer current transformer parameters analyzer features analyzer CT parameter tester tester current transformer current transformer parameters characteristics tester Comprehensive instrument for the transformer
Applications:
Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
Features:
1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.
Alternating and direct current amphibious light AC DC Hipot Test Set. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Product Introduction
Dc high voltage generator adopts high frequency pulse width modulation (PWM) technology to makeclosed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The wide temperature LCD screen adopts green back light, which enables clear display either in bright light or in darkness. High-pressure components use Dupont new filling material, making the product more stable and reliable. Products are widely used in electricity power supply departments, power transmission and transformation engineering company and preventive test of large industrial enterprises and scientific research institutes as regulated dc high voltage power supply.
product brief introduction Product Introduction
series is the equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through which completely overcome the problems of long blow water time bottom water hard to dry easy to cause arcing within the coil. The device is light simple wiring and easy to read. Polarization compensation voltage is output directly by the case.
product features Product Characteristics
1. Electronic control and tune easy to operate.
2. The date of voltage and current are recorded in the panel reading without conversion.
3. One minute timing and tip function.
4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator.
5. Portable design suitable for on-site testing.
6. Four parts separated: control unit Intermediate Frequency Transformer doubler and accessories all packed with special shockproof aluminum alloy cabinet easy to move.
Product Introduction
The TKJF-208 hand-held partial discharge detector is used to detect the local discharge power supply in medium and high voltage equipment.If no discharge is detected it does not mean that there is no discharge activity in medium and high voltage equipment.Power discharges often have an incubation period and the insulation may fail for reasons other than partial discharge.If a significant discharge is detected in equipment connected to the medium-high voltage power system the equipment maintenance department should be notified immediately.
product features Product Characteristics
a) Screen display: high-contrast 3.5 TFT color screen.
b) Data storage: 1000 groups of test data can be stored.
c) Working power supply: embedded 8.4V lithium battery for 8hs continuous operation.
d) Power supply: input 100-240VAC output 8.4V/3A charging time 34h.
e) Boundary dimension:230 * 120 * 55(mm).
f) Instrument weight:1.5kg.
g) Environment temperature: -25 45
h) Storage temperature: -35 60
Complete configuration: host machine sensor AC adapter connecting cable and transport case.
Product Introduction
YDW series PD tester system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities.
product features Product Characteristics
A variety of control methods and insulation methods can be used to configure freely according to user demand.
Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi-frequency power generator which can be used to measure the discharge of high voltage transformer.
Manual control operation is intuitively easy to use maintenance low price.
It has gas insulation transformer oil insulation dry epoxy resin insulation and other forms test transformer can choose and match according to user's demand.
According to the user's requirements, different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults.
An automatic control system can be used in different configurations of the bureau and the results can be automatically detected and analyzed.
Product Introduction
Insulation boot (glove) withstand voltage test device is designed and manufactured by our company according to the test procedure of gloves (insulated boots) and in accordance with the opinions of users. This product effectively solves the irregular test methods in the past which simplifies the testing procedures and improves the testing speed. More reliable identification of gloves (insulated boots) leakage current insulation aging power frequency withstand voltage and other parameters. It is the ideal equipment for gloves (insulated boots). Its main features: It can test 3 pairs of gloves (insulated boots) at the same time and can read each leakage circuit to accurately judge the unqualified gloves (insulated boots); the bottom of the structure can be moved freely.
product features Product Characteristics
1 Insulation boot (glove) withstand voltage test device effectively solved the past irregular test
2 improve work efficiency ensure work safety is an ideal special equipment for insulated boots (gloves)
product brief introduction Product Introduction
TC power frequency voltage tester adopts integrated design, small size, light weight, more convenient for transportation and portable operation. The over-current protection of voltage tester is set by current relay, The high-voltage output, direct reading instrument and operation are integrated with the voltage stand. Therefore, the operation is simple, practical and reliable
product features Product Characteristics
1 Functions output current instrument voltage regulator Zero point/Closing indicator timing indicator.
2 defensive function overcurrent protection timer.
3 Adopt new time relay. The timing range is much wider.
4 Adopt new current relay more precise more reliable Ensure personal and equipment safety.
5 reasonably structured small in size in light weight.
Alternating and direct current amphibious light AC DC Hipot Test Set. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Product Parameters
technical parameters
environment temperature 0 40
altitude < 100m
relative humidity < 85%
Main product specifications
type specification capacity power source output operating mode Refer to the weight
anthroposcopy (V) (A) (V) (A)
XC-2 2 1 220 50 0-220 10 manual operation 14
XC-3 3 1 220 50 0-220 15 manual operation 16
XC-5 5 1 220 50 0-220 20 manual operation 18
product features Product Characteristics
1 monitoring functions output current instrument voltage null-reading cross pointer Closing indicator timing indicator
2 defensive function overcurrent protection timer
3ã??Adopt new time relayï¼?The timing range is much wider
4 Adopt new current relay more accurate more credible ensure personal and equipment safety
5 reasonably structured small in size in light weight
product brief introduction Product Introduction
The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
warning
1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit.
2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity.
3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire.
4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
product brief introduction Product Introduction
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Product Introduction
Dc high voltage generator adopts high frequency pulse width modulation (PWM) technology to makeclosed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The wide temperature LCD screen adopts green back light, which enables clear display either in bright light or in darkness. High-pressure components use Dupont new filling material, making the product more stable and reliable. Products are widely used in electricity power supply departments, power transmission and transformation engineering company and preventive test of large industrial enterprises and scientific research institutes as regulated dc high voltage power supply.
product features Product Characteristics
1 The output voltage is stable: the high-frequency voltage doubler circuit is applied and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate so that the voltage stability is high and the ripple is small.
2 comprehensive protection: full protection function with zero protection over-voltage protection over-current protection breakdown protection protection circuit uses nanosecond-level special sensor action fast and reliable effectively protect personal and equipment safety.
3 0.75U function: Add intelligent high-precision 0.75U function one-button button press this button the voltage and current will automatically jump to the 0.75U state which is conducive to the test of zinc oxide arrester.
4 zero boost: The boost potentiometer starts from zero adopts imported multi-turn potentiometer the boosting process is stable and the adjustment precision is high.
5 over-voltage setting: over-voltage setting uses digital dialing switch easy to operate and has a high setting accuracy.
6 one-piece design: the choice of integrated design Host and double pressure cylinder is placed in a chassis. The imported high-frequency high-voltage rectifier diode is used to make the double-pressure cylinder small in size improve the efficiency of the whole machine and is easy to carry.
7 reliable performance: the key components use high-performance imported components the pressure roller is coated with special insulating materials good electrical performance strong moisture resistance no leakage.
8 the operation is simple: the instrument interface each function button the layout is reasonable the instructions are clear easy to learn and use.
Product Introduction
TheBY2671 digital megohm meter (2500V) is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD.
Product nicknameï¼?Digital megohmmeter megohmmeter digital megohmmeter digital display insulation sheet insulation resistance by megger tester high voltage insulation resistance tester insulation resistance meter insulation characteristics tester electric shake table digital wave table digital display table digital megohmmeter digital megohmmeter high voltage digital insulation resistance tester high voltage insulation resistance tester digital high voltage megohmmeter digital high voltage megohmmeter high Voltage digital megohm meter digital insulation meter digital display insulation meter electronic insulation resistance tester digital insulation resistance tester digital display insulation resistance tester digital display insulation resistance tester insulation resistance meter digital electric megohm meter digital high voltage megohm meter high voltage megohm meter.
Product Introduction
The ground resistance measuring instrument is a new type of ground resistance measuring instrument which combines the three-end button and four-end button measuring methods by using advanced medium and large scale integrated circuit instead of the traditional manual manual power generation.
The working principle is that the DC/AC converter in the machine changes DC into low-frequency constant current of AC and the circuit is formed by auxiliary ground electrode C and measured object E which generates AC voltage drop on the measured object and is fed into AC amplifier for amplification through auxiliary ground electrode P and then sent to the meter head for display through detection. With the aid of multiplying power switch three different quantity limit can be obtained: 0 ~ 2 �© 0 ~ 20 �© 0 ~ 200 �©.
The earth resistance measuring instrument is suitable for measuring the earth resistance of various devices and the conductor resistance value of low resistance in electric power post and telecommunication railway communication mining and other departments. The table also measures soil resistivity and ground voltage.
Product nicknameï¼?digital ground resistance tester digital ground resistance tester ground resistance ground resistance meter ground resistance meter ground resistance meter ground resistance meter ground resistance meter ground pile ground resistance tester digital ground resistance meter portable ground resistance tester digital ground resistance meter
Product Introduction
Transformer Tester is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARMadvanced manufacturing technology ensure a stable and reliable product performance full-featured high degree of automation high efficiency in the domestic leading level they are the professional testing equipments for transformer check in power industry.
Product namesï¼?CT parameter analyzer CT analyzer frequency CT analyzer CTPT analyzer transformer tester frequency transformer characteristic tester transformer transient characteristic analyzer current transformer tester CT characteristics analyzer current transformer current transformer parameters analyzer features analyzer CT parameter tester tester current transformer current transformer parameters characteristics tester Comprehensive instrument for the transformer
Recommended products
Product Introduction
Digital PD Detector Partial Discharge Testing
Digital PD Detector Partial Discharge Testing Product Overview
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method).
Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy.
product features Product Characteristics
Digital PD Detector Partial Discharge Testing Working Condition
Altitude 3000m
Environmental Temperature -20~60C
Relative Humidity 95%
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Dc high voltage generator adopts high frequency pulse width modulation (PWM) technology to makeclosed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The wide temperature LCD screen adopts green back light, which enables clear display either in bright light or in darkness. High-pressure components use Dupont new filling material, making the product more stable and reliable. Products are widely used in electricity power supply departments, power transmission and transformation engineering company and preventive test of large industrial enterprises and scientific research institutes as regulated dc high voltage power supply.
product features Product Characteristics
1ã??The output voltage is stable: the high-frequency voltage doubler circuit is applied and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate so that the voltage stability is high and the ripple is small.
2ã??comprehensive protection: full protection function with zero protection over-voltage protection over-current protection breakdown protection protection circuit uses nanosecond-level special sensor action fast and reliable effectively protect personal and equipment safety.
3ã??0.75U function: Add intelligent high-precision 0.75U function one-button button press this button the voltage and current will automatically jump to the 0.75U state which is conducive to the test of zinc oxide arrester.
product brief introduction Product Introduction
series is the equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through which completely overcome the problems of long blow water time bottom water hard to dry easy to cause arcing within the coil. The device is light simple wiring and easy to read. Polarization compensation voltage is output directly by the case.
product features Product Characteristics
1. Electronic control and tune easy to operate.
2. The date of voltage and current are recorded in the panel reading without conversion.
3. One minute timing and tip function.
4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator.
5. Portable design suitable for on-site testing.
6. Four parts separated: control unit Intermediate Frequency Transformer doubler and accessories all packed with special shockproof aluminum alloy cabinet easy to move.
Product Introduction
The TKJF-208 hand-held partial discharge detector is used to detect the local discharge power supply in medium and high voltage equipment.If no discharge is detected it does not mean that there is no discharge activity in medium and high voltage equipment.Power discharges often have an incubation period and the insulation may fail for reasons other than partial discharge.If a significant discharge is detected in equipment connected to the medium-high voltage power system the equipment maintenance department should be notified immediately.
product features Product Characteristics
a) Screen display: high-contrast 3.5 TFT color screen.
b) Data storage: 1000 groups of test data can be stored.
c) Working power supply: embedded 8.4V lithium battery for 8hâ??s continuous operation.
d) Power supply: input 100-240VAC output 8.4V/3A charging time 3ï½?4h.
e) Boundary dimension:230 * 120 * 55(mm).
f) Instrument weight:1.5kg.
g) Environment temperature: -25-45
h) Storage temperature: -35-60
Complete configuration: host machine sensor AC adapter connecting cable and transport case.
Product Introduction
YDW series PD tester system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities.
product features Product Characteristics
A variety of control methods and insulation methods can be used to configure freely according to user demand.
Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi- frequency power generator which can be used to measure the discharge of high voltage transformer.
Manual control operation is intuitive easy to use maintenance low price.
It has gas insulation transformer oil insulation dry epoxy resin insulation and other forms test transformer can choose and match according to user's demand.
According to the user's requirements different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults.
Automatic control system can be used in different configurations of the bureau and the results can be automatically detected and analyzed.
product brief introduction Product Introduction
The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
warning
1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit.
2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity.
3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire.
4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
product brief introduction Product Introduction
TC power frequency voltage tester adopts integrated design, small size, light weight, more convenient for transportation and portable operation. The over-current protection of voltage tester is set by current relay, The high-voltage output, direct reading instrument and operation are integrated with the voltage stand. Therefore, the operation is simple, practical and reliable.
product features Product Characteristics
1 functions output current instrument voltage regulator Zero point/Closing indicator timing indicator.
2 defensive function overcurrent protection timer.
3 Adopt new time relay The timing range is much wider.
4 Adopt new current relay more precise more reliable Ensure personal and equipment safety.
5 reasonably structured small in size in light weight.
product brief introduction
AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
Product Introduction
TKJF fit for many products it has high sensitivity high S/N a large screen which has clear testing wave displaying high frequency ellipse scan (the power is less than 1VA). auxiliary zero marking system. The discharge meter has pointer/digital display and linearity /digital function. The amplifier has large dynamic range 9 kinds of frequency band combinations.
TKJF is a powerful tool for developing new high voltage electric products and improving the quality of the products. It is also an efficient testing device to judge the work condition of equipments on the work field. This device is used together with model JZF-9 or JZF-10 calibrator.
product features Product Characteristics
Working Principle
When measured piece Cx has partial discharge under testing voltage the circuit will have pulse current which get by the input unit. The pulse signal is amplified by front amplifier and the frequency band is chose by filter amplifier then been amplified to needed amplitude by the main amplifier. The pulse signal will be displayed on oscillograph screen. The pulse value is also sent to the pulse peak meter and displayed immediately. The time window unit chooses a working period of the pulse peak meter during each cycle of testing voltage and it increases the brightness of the relevant displaying area in this time. In this way it can avoid the disturbing of fixed phase.
Input discharge volume to the measured piece Cx through JZF series PD external calibrator adjust the fine adjusting knob till the displayed value is equal to the discharge volume the discharge can be read directly and conveniently on the meter without counting.
The testing voltmeter will have an over zero mark signal of testing voltage through the voltmeter resistance R and the zero mark pulse will be displayed on oscillograph screen. The testing voltage can be displayed on KV meter.
Product Introduction
TKDL-WS automatic temperature rise test system is used for manufacturers testing the high and low voltage electrical products before delivery. It provides two functions of large current and temperature test. Convenient for user operation improves working efficiency. It applies to power plant power distribution station electrical appliance manufacturing factories scientific researching institutes laboratory. Multi channel temperature recorder uses digital synchronous sampling technology with advantages of rapid test speed high precision convenient to operate good appearance.
product features Product Characteristics
1ã??This product is composed of large current generator voltage regulator temperature tester industrial controlling computer operation system.
2ã??Voltage and current displayed by industrial controlling computer software precision level is 0.5.
3ã??With zero position starting up protection function and emergency stop function.
4ã??Software test time self setting and with prompting function.
5ã??After current setting any deviation software can automatically adjust according to the parameters set in advance.
6ã??Prevent strong magnetic interference.
7ã??Use imported K type thermocouple: 0~1370â??.
8ã??Temperature tester with multi channel temperature monitoring measuring recording function and comparing with the test point temperature formrising temperature self alarm when the rising temperature higher than setting temperature. Any point temperatures and temperature rising value can be checked measurement error is �±1%.
9ã??Adopt anti interference technology combined with the hardware and software function is stable and anti-interference is strong. Four basic screens digital display picture bar chart display picture real time curve picture recall curve picture.
product brief introduction Product Introduction
FRC A/D digital kilovoltmeter consists of a high stabilized resistive-capacitive type passive high-voltage divider and a precision digital voltmeter for measuring AC/DC high voltage on the site of electric power systems and in various high-voltage laboratories. Both of them with measuring cable, power supply cord, and operating manual are placed in a portable aluminium case for easy carrying and use.
product features Product Characteristics
The AC/DC digital kilovoltmetre is composed of two parts of a high voltage divider and a digital kilovoltmetre. The high voltage divider is of a passive resistive-capacitive type, assembled from precision low temperature drift resistors and high quility condensers. Digital kilovoltmeter consists of ture RMS value circuit, peak values measuring circuit and digital voltmeter. Voltage divider is connected to digital kilovoltmeter by a coaxial measuring cable. The high voltage is reduced to sample value by the voltage divider, and be fed to digital voltmeter. Through function selector, the voltmeter can display DC,AC effective(RMS)value, AC peak value, and AC peak/2 value with high measuring accuracy and convenience in use.
product Characteristics
1 Instrument output current light weight
2 Two current output wider test range higher stability
3 It can calculate the transition resistance value and transition time value automatically
4 Has the perfect protection circuit the reliability is strong
5 5.7 "large LCD display easy to operate on site
6 With usb flash disk storage function you can store more data waveform
7 The keyboard and the one-key flying shuttle operate independently making the instrument operate more quickly and conveniently
Dc resistance around the group of measurement transformer is a very important test project. In the "test regulations of electric power equipment" its order ranks the second in the transformer test project. The "regulations" stipulates that pick up overhaul minor repair change sub-pick up head position fault check and pre-test etc. should be done in transformer. Measurement transformer must have dc resistance around the group whose purpose is:
(1) check the welding of line and lead line around the group;
(2) check if the pick up touch is good;
(3) check whether there is a broken place around the group or leading line;
(4) check the correctness of the parallel branch whether there is a few parallel guide lines winding into the winding group or a few broken line situation;
(5) check whether there is a short circuit between layers and turns.
The interface design of Dc resistance rapid test instrument adopts microcomputer control big screen backlit Chinese liquid crystal screen show operation is simple show clear man-machine interaction interface friendly measurement process and instrument work state prompt is clear and sufficient no operation personnel need to memorize too many procedures; Huatian electric power adopts current source line-based compensation technology with stable test high measurement precision and fast speed improving measurement efficiency and reducing work intensity of operation personnel. Technically "four-end" measurement is adopted to eliminate the measurement error caused by line resistance with pick up contact. Overvoltage protection function can resist electric potential impact. Panel printer can print measurement results quickly (selected). Small size light weight easy to carry.
Dc resistance rapid test instrument is applicable to measurement with analysis of various electric transformer transformer winding group and other perceptual low resistance.
Transformer dc resistance test instrument is an indispensable test project of Transformer after handing in pick up overhaul and change sub-pick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce the work burden of test personnel huatian electric power company developed Transformer dc resistance test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small volume easy to use high measurement precision and good data repeatability. Measurement transformer around the group and large power inductor dc resistance ideal equipment.
Product Parameters
Service conditions
Temperature 5-40
Humidity
The test system is mainly for power transformer distribution transformer no-load load characteristics; Dc resistance; Variable ratio group test also can be tested transformer power frequency withstand voltage test. At the same time external pick up ct interface is reserved for capacity increase.
Transformer comprehensive test station measurement part is controlled by single chip microcomputer and testdata such as digital display no-load and short circuit are sampled synchronously by single chip microcomputer avoiding errors caused by manual calculation of voltage ammeter and power meter readings respectively in traditional test methods.
Product Characteristics
1. Applicable to transformers connected in Z type.
2. Two output voltages are optional and applicable to transformer whose zero-load current is relatively high.
3. Have wide testing range and the highest transformation ratio may reach 10000.
4. Automatically calculate tap position.
5. Fast speed which is only 18 seconds for three-phase.
6. Favorable repeatability.
7. Automatically save 99 data at most.
8. Flexible data processing including retrieval print transfer to U-disk delete and upload to PC computer for testing.
9. Have transformer short-circuit protection and interturn short-circuit protection functions. In case of short circuit relevant information will be displayed on the LCD screen in characters.
10. The upper computer could control the whole testing process save data .
11. Struction manual is attached to the tester providing convenience for users.
12. The tester is small and is a little bigger than a piece of A4 paper.
13. The tester is light and its weight is only 6.9kg.
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A.
1. The instrument can be used separately or linked to PC.
2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system.
3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability.
4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity.
5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure.
6. Two options: ampere-second characteristic test or through current characteristic test.
7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation.
8. Protection functions for overheat over-current and over voltage.
Product Overview
TKKGG-H Series HV/LV Switch Cabinet Test Bench is mainly applied for ex-work energized testing for high voltage and low voltage cabinet manufacturers. The test bench could provide various AC/DC power source in order to detect switch cabinet.
Feature Reading directly: Digital meters to display current voltage power factor test value.
Measuring accurately: High precision test value is accurate.
Full protections: Each circuit is with air switch protection.
Portable: Small size light weight easy to move.
Product Overview
TKDL Cable Identifier is designed to identify a special one within a group of cables during the power cableâ??s setting up moving maintaining and faults processing. Itâ??s suitable for all kinds of HV & LV cables.
Features
Can identify energized or de-energized cable.
The system is composed by signal transmitter receiver transmit clamp receive clamp and some connection leads.
Large power current pulse output.
On-site receiving signal is clear.
Light weight high sensitivity and anti-interference ability.
To identify needed cable with or without electric.
Accurate and fast identifying.
Reliable protective circuit.
Large diameter clamp suitable for all kinds of section surface cable.
Build-in large power insulated transformer there is no any electrical contact between mains supply and user.
The normal operation of cable-communication and electric transport completely rely on the good condition of the cable-circuit. Once the circuit breaks down and without punctually examination and repairing it will no doubt trigger the mass economic loss and bad social influence. So the electric fault measuring testing instrument is a very important tool. The intellectual testing instrument uses multiple testing methods and adopts the most advanced electronic devices and with computer and special electronic technology combining our companyâ??s successful experience of long-time exploitation on cable-fault measuring testing instruments and it is absolutely of high tech intelligence and abundant functions.
Our cable-fault detector is a testing device of good integrity. It can test on the High Resistance Flashover Fault Grounding High and Low Resistance Fault Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument it can exactly detect the fault point. Furthermore it especially applies to test for various power cable and communication cable.
Product Overview
Adapts advanced technology TKGX Underground Cable Detector is the most effective device to detect underground utilities of gas electric power telecom water supply drainage cable television and etc.
Features
Portable designation suitable for wild field testing.
Full digital control easy to control.
English graphic display.
Transmitter designed with over load and overheating protection.
To detect the location and depth of underground cable accurately also is available for branch pipe or network construction underground cable.
Two detect methods: AC current gradient method and ground electric field method.
To locate and detect depth of underground cable synchronously.
Underground cable fault locator is my company in order to cater to the advent of the era of power the power industry in the integration of many high-quality goods package the cable fault testing industry with the rapid development of the IT era as an opportunity the single chip microcomputer and laptop type of cable fault tester on the basis of embedded computer platforms to create suitable for cable fault testing industry characteristics of network cable fault testing service platform and systematic integration of the USB communication technology touch screen technology 3 g communications technology greatly improve the function of the use of the instrument and the use value and convenient site environment operation.Considering the increasing number of buried cables;The system satisfy the People's Republic of China power industry standard "DL/T849.1 ~ DL/T849.3-2004" electric power equipment dedicated testing equipment general technical conditions the system test by the host system multiple pulse generator the path of cable fault locator and instrument of four parts used in power cable fault test path the embedding depth of cable for airport and railway signal control cable and street lamp accurate test of cable fault.
Thanks to the hard work of many engineers in the company the product has reached the international level especially since the whole set of devices has surpassed the world level in portability.The core technology of the multi-pulse method has changed the traditional testing method which has fundamentally solved the problem of high-resistance fault waveform reading that was difficult to solve previously. After multi-pulse generator any complex high-resistance waveform can be converted into a very familiar and easy to identify low-voltage pulse short-circuit fault waveform.It solves the problem that the user cannot recognize the complicated high resistance fault waveform for a long time and improves the level of the key rough measurement.
TKBLQ-II zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-II zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable.
1. This machine adopts large screen LCD display all English menu operation easy to use.
2. High precision sampling and processing circuit and advanced Fourier harmonic analysis technology ensure more reliable data.
3. The instrument adopts high-speed magnetic isolation digital sensor to directly collect the input voltage and current signals which ensures the reliability and safety of the data.
4. Support wireless synchronous voltage sampling mode (type II).
5. The instrument can use electric field induction instead of PT secondary wiring (type I).
6. It has the functions of resistive current fundamental peak output and side phase correction.
7. The instrument is equipped with rechargeable battery calendar clock and micro printer which can store 120 sets of measurement data.
This instrument is carefully designed and developed by the relevant technical personnel of our company according to the needs of power users. The product is beautiful in appearance and easy to carry and use. It replaces the traditional bulky test instruments and test methods and is very popular among professionals.
1. Small size and light weight.
2. The measurement process is safe and fast and the measurement result is accurate.
Product description
Digital detector partial discharge test and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
Echnical parameter
Number of channels: 4 independent measurement channels (scalable) and 1 external trigger input channel.
Sampling rate: 200MSa / s
Sampling accuracy: 12bit
Host Screen size: 6.5 inches
Operation: mouse keyboard touch screen
Host interface: 2 USB ports 1 Ethernet port 1 VGA port.
Synchronous Frequency range: 30Hz ~ 1MHz
Power Mode: Built-in lithium battery or external AC power supply (AC220V 50Hz)
Measurement content: Discharge magnitude (Q) the discharge phase (?) the discharge density (N)
Data processing sampling period: 1s
3 amplitude-time a relationshipmagnitude-phase relationship number of discharges-phase relationship
Charging power supply: AC220V; 50Hz frequency
System design life: more than 10 years
Product description
Partial discharge test system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities.
Technical Parameters:
Rated Capacity
5-1000kVA
Impedance Voltage
10%
Input Voltage
AC 220V/AC 380V
Output Voltage Waveform
Power frequency sine wave
Output Voltage
AC 0-1000kV
Surface Temperature
Oil immersed:
Overview:
The Intelligent dielectric loss tester also applies to the measurement of tg�´ and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes.
It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg of capacitor voltage transformer and capacitance of main capacitor C1and C2.
Main Specifications
Control panel: printer, keyboard, indicator and communication transferring.
Variable frequency power supply: SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage.
Step-up transformer: the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA/one minute.
Standard capacitor: internal Cn. It is the measuring basis.
Cn current detection: it is used to detect the internal standard capacitor current, 10A ~ 1A. The input resistance is
Product description
Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system.
When it is interfered or contaminated, grid power quality canâ??t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.
3 phase handheld power quality analyzer Technical index
1. Input characteristics
Voltage measuring range: 0 200V 800V, automatic cutting gear.
Current measurement range
Clamp transformers (three types): 5A / 25A (standard)
100A / 500A (optional)
400A / 2000A (optional)
Phase angle measuring range: 0 ~ 359.99 .
Frequency measurement range: 45 ~ 55Hz.
Voltage channels: three-channel (UAã??UBã??UC).
Current channels: three-channel (IAã??IBã??IC).
Maximum harmonic analysis times: 63 times.
Maximum continuous storage period in 1 minute interval: 18 months.
2. Accuracy
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.
Technical index
Oil cup technical specifciations:
Distance between High Voltage terminal
and Low Voltage terminal 2mm
Capacitance of Empty Cup 60 ±2PF
The Highest testing voltage Industrial Frequency 2000V
Dielectric Loss of Empty Cup tg 1 10-4
Liquid capacity About 40ml
â?¹ Electrode Material Stainless Steel
â?º Volume 70mm(D)�?120mmï¼?Hï¼?
1
Condition of Use
-5â??â?½40â?? RHï¼?80%
2
Power Source
Product description
6 Phase Relay Protection Tester High performance Industrial control computer is adopted as the controlling computer, through which you can run the windows operating system directly. 8.5"TFT true color LCD display, tracking ball and optimized keyboard are located on the faceplate of this tester, which can be used without the external mouse and keyboard. USB interface, 10-100M net mouth and serial communication interface are located on the back plate of this tester, through which you can access data, communicate data and upgrade software conveniently.
Technical index
Current generators General
Setting range Accuracy 0.2%typical 6-phase ac(L-N) 6*0 30A Distortion 0. 5%typical 3-phase ac(L-N) 3*0 60A Resolution 4.0mV
1-phase ac(L-N) 1*0 180A Generator, general
6-phase dc(L-N) 6*0 10A Frequency range
3
Introduction
The SF6 gas comprehensive instrument is a three-in-one tester that integrates, concentration, and main crystallization measuring instruments. It concentrates the achievable capabilities into one and completes three functional tests at a time, which greatly reduces the gas emissions in the equipment and effectively protects the environment. , Pollution, while reducing the user's workload and improving work efficiency.
It is because the sensor of Finland Vaisala is used; the SF6 gas comprehensive supplementary instrument has sufficient performance, and it uses an efficient absorption sensor.
The special instrument adopts the sensor of German HNP; some products adopt the special sensor of imported American Dekang SF6.
The SF6 integrated equipment display adopts a large-screen Chinese display, real-time various parameters, intelligent and intelligent operation, massive information, and dual-use rechargeable batteries.
Energy-saving technology, energy-saving and environmentally friendly instruments.
The SF6 comprehensive tester adopts the sensor, sensor, SOH2S, CO and other sensors of Finland VAISALA company, and adopts the thermal conductivity type of British ALPHA company.
Sensors and R&D sensors; more advanced ARM development technology, quality sensors, sensors and other precision sensors, equipped with sensors and sensors are more realistic, more simultaneous, and manufactured. The tester uses a color screen screen display, friendly interface, and easy to operate.
This type of comprehensive tester uses reliable imported sensors as sensitive components, and at the same time integrates real-time measurement, curve display, power management, time system, file system, data query, data understanding and other update functions, and integrates advanced sensor technology. And information technology, humanized operation information technology, humanized operation and perfect functions, you can learn her ability and perfection in printing.
Product description
Multifunctional transformer test bench is a new generation of calibrating device, faster and more accurate. We dedicately develop it to meet the demand of modern calibration. It is made up of an HGQA-C Transformer Calibrator, a current load case, a special test standard for CT and so on. Inheriting the oringinal the features, it is remarkably improved. With flexible match with more load cases and transformers, it performs excellently in quick test and quick point location during CT test.
Technical index
Environment Conditions
Temperature 5 C~40 C
Relative humidity
Product description
Automatic tension tester Intermolecular Forces formed liquid surface tension.Numbers of tension reflect on liquid sampleâ??s physics and chemical properties, it is one of the most important index to product quality. automatic interfacial tension tester apply to GB/T6541,it can test kinds of liquid surface tension and boundary surface tesion.this method sample and accuracy,so its used widely
Specifications
Measuring rang 0-200mN/m
Accuracy 0.1%( test result) ±0.1 mN/m
Precision 0.1mN/m
Sensibility 0.1mN/m
Mains voltage AC220V ±20% 50HZ±10%
Maximum power dissipation 20W
Suit ambient temperature 10 30 (25 the best)
Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 High Voltage Shunt Capacitors DLT840-2003 Technical Conditions for Use of High Voltage Shunt Capacitors and JB5346 1998 Series reactor and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device.
Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data.
Overview
Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer.
Technical parameter :
AC current output
Output accuracy 0.5A 2mA
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 900VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (fundamental) 20 1000Hz
Harmonics 1 20 times
AC voltage output
Output accuracy Level 0.2
Phase voltage output valid value 120V
Line voltage output valid value 210V
Maximum voltage output value 240V
Phase voltage / line voltage output power 80VA 100VA
Frequency range (fundamental) 20 1000Hz
Harmonics 1 20 times
Product description
Insulation Resistance Tester is suitable for measuring high capacity transformers, transformers, generators, high voltage electric motors, power capacitors, power cables, surge arresters and other ideal insulation resistance test equipment.
Technical index
Model
BC2306
Rated
Voltage
5000V
10000V
Measuring Range
This instrument use high accuracy (1uA) leakage test and updated CT shielding technology. It is composed of special HV detector and HV insulation rod. It can wireless transmit testing data within distance of 30m.
1. The full realization of the zinc oxide arrester online uninterruptible power test.
2. The latest CT and shielding technology.
3. No lightning counter can test the zinc oxide arrester leakage current.
4. Completely solve the 6-10kV zinc oxide arrester test problems.
5 without climbing pole without wiring fast and accurate test.
6 can accurately detect the leakage current of 10uA.
7. Zinc oxide surge arresters or aging judgment online.
8. High-speed sampling frequency advanced digital signal processing technology anti-jamming performance high accuracy measurement results.
9. Optional configuration with battery especially suitable for power occasions.
10. Small size light weight easy to carry.