The Intelligent dielectric loss tester also applies to the measurement of tg and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes.

It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg´ of capacitor voltage transformer and capacitance of main capacitor C1and C2.



Main Specifications

Control panel printer, keyboard, indicator and communication transferring.

Variable frequency power supply SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage.

Step-up transformer the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA one minute.

Standard capacitor internal Cn. It is the measuring basis.

Cn current detection it is used to detect the internal standard capacitor current, 10A 1A. The input resistance is

Price and Minimum Quantity

Price: $770 - $15397
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Intelligent Dielectric Loss Tester

Aug-25-21

Intelligent Dielectric Loss Tester

$770 - $15.40K
MOQ: Not Specified
 
Overview:

The Intelligent dielectric loss tester also applies to the measurement of tg�´ and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes.

It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg of capacitor voltage transformer and capacitance of main capacitor C1and C2.



Main Specifications

Control panel: printer, keyboard, indicator and communication transferring.

Variable frequency power supply: SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage.

Step-up transformer: the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA/one minute.

Standard capacitor: internal Cn. It is the measuring basis.

Cn current detection: it is used to detect the internal standard capacitor current, 10A ~ 1A. The input resistance is
Sep-09-21

Intelligent Tg Dielectric Loss Tester

$770 - $15.40K
MOQ: Not Specified
 
Overview:

The Intelligent Tg dielectric loss tester is equipped with high voltage step-up transformer. Besides, it takes security measures like zero-cross closing, lightning protection, etc. During the experiment, different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantages of convenient and safe operation.



Technical index

The Intelligent Tg dielectric loss tester has: printer, keyboard, indicator and communication transmission.

Detect internal standard capacitor current: 10�¼A~1A

Positive connection measurement: 10�¼A~1A

Amount of negative connection side: 1A~1A

Side volume range: 0.001%
May-06-22
 
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.


Technical index

Oil cup technical specifciations:

Distance between High Voltage terminal

and Low Voltage terminal 2mm

Capacitance of Empty Cup 602PF

The Highest testing voltage Industrial Frequency 2000V

Dielectric Loss of Empty Cup tg1 10-4

Liquid capacity About 40ml

Electrode Material Stainless Steel

Volume 70mm(D) 120mm


1

Condition of Uss

2

Power Source

AC 110V10% Without Frequency Limit

3

AC High Voltage Output

4

DC High Voltage Output

Temperature Control Induction Stove

Maximal Power 500W

6

Temperature Control Range
Aug-25-21

Oil Dielectric Loss Tester

$770 - $15.40K
MOQ: Not Specified
 
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.


Technical index

Oil cup technical specifciations:

Distance between High Voltage terminal

and Low Voltage terminal 2mm

Capacitance of Empty Cup 60 ±2PF

The Highest testing voltage Industrial Frequency 2000V

Dielectric Loss of Empty Cup tg 1 10-4

Liquid capacity About 40ml

â?¹ Electrode Material Stainless Steel

â?º Volume 70mm(D)�?120mmï¼?Hï¼?


1

Condition of Use

-5â??â?½40â?? RHï¼?80%

2

Power Source
Aug-05-21

Oil Dielectric Loss Tester

$770 - $15.40K
MOQ: Not Specified
 
Product description
Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.


Technical index

Oil cup technical specifciations:

Distance between High Voltage terminal

and Low Voltage terminal 2mm
Capacitance of Empty Cup 60±2PF

The Highest testing voltage Industrial Frequency 2000V

Dielectric Loss of Empty Cup tg 10-4

Liquid capacity About 40ml

Electrode Material Stainless Steel

Volume 70mm(D) 120mm H
1

Condition of Use

-5-40 RH 80%

2

Power Source

AC 110V±10% Without Frequency Limit

3

AC High Voltage Output

400V 2200V ±2% Every 100V 50VA

4

DC High Voltage Output

200V 600V ±2%

5

Temperature Control Induction Stove

Maximal Power 500W

6

Temperature Control Range
Dec-24-21
 
Product Introduction
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.

This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.



Technical Parameters




Measuring range Dew point value 80 20
Moisture content 0 19999uLL
Accuracy of measurement 0.5 60 20
1.0 80 60
The resolution of the Dew point value 0.1
Moisture content 1uLL
Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20
63 needs 10s 90 needs 240s 20 60
Sampling flow 0.6L min 20
Pressure range 01.0Mpa
The use of temperature 20 60
Environmental humidity 0 100 RH
Storage temperature 20 80
Charging time 4 hours
The whole machine size 250 150 300mm3
The weight of The machine 3.5kg
Jul-09-21

Insulating Oil Dielectric Loss

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
In the preventive insulation test of power equipment it is required to measure the insulation oil parameters of power equipment periodically. The measurement of dielectric loss and resistivity of insulating oil is one of the most important. For a long time most of them adopt the bridge method for measurement which is complicated in operation and the measurement accuracy is affected by many factors thus leading to a large measurement error. With the rapid development of electronic technology and the power industry for small volume light weight easy to operate rapid measurement high precision measurement instrument requirements I refer to domestic and foreign related instruments developed in the domestic leading insulation oil dielectric loss factor and dc resistivity tester. The instrument is designed and manufactured according to gb5654-2007 and related standards. It is controlled by microcomputer easy to use high measurement accuracy high test efficiency and greatly reduces labor intensity.
Jul-08-16
 
ZJY automatic dielectric oil breakdown voltage tester is highly precise laboratory testing instrument, it is used to determine the withstanding capacity of any insulating oil. BDV test is a test of choice because it takes very less time to conduct and is a precursor to the condition of the insulating liquid, before carrying out extensive series of tests. ZJY dielectric oil breakdown voltage tester is accurate automatic oil BDV test set and testing standard can be IEC156 and ASTM according user’s requirement.

Features:
1.ZJY Oil Breakdown Tester are available in a variety of maximum test voltages (60KV,80KV and 100KV)
2. Repetitive test sequence (up to 99 iterations)and average readings (from first to last)
3. Digital display output With LCD screen.
4.ZJY oil breakdown voltage tester can be used to test specimen as per standard IEC 156 and ASTM
5.ZJY oil breakdown voltage tester is wildly applied to accurately measure the dielectric oil breakdown voltage
Dec-23-21
 
OVERVIEW

Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB T507-2002, industry standard DL429.9 91 and the latest Electric Power Industry Standard DL T846.7-2004 by ourselves. This instrument, by using a single chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.



MAJOR TECHNICAL INDICATORS

Output voltage 0 100KV optional

Voltage distortion rate 3

Voltage raising speed 0.5 5 KVS adjustable

Standing time 15min adjustable

Boosting interval 5 min adjustable

Boosting frequency 1 9 time s optional

Booster capacity 1.5KVA

Measuring accuracy 3

Supply voltage AC220V 10

50Hz1 Hz

Power 200W

Applicable temperature 0 45

Applicable humidity 75 RH

Overall dimension 465 385 425

Transformer Oil Dielectric Strength Tester 2

Verification Status