Please click here to check who's online and chat with them.

Insulator Distribution Voltage Tester

Supplier From China
Jul-08-21

Application:

TK-15 insulator distribution voltage tester is used to test string of voltage distribution of AC circuit 35-500kV insulator. Insulator distribution voltage test meter also can do all kinds of 35kV and AC voltage measurement in laboratory. It is an ideal testing meter for the safety of line operation and the auxiliary tools for live operation.


Features:

This insulator voltage distribution tester use the static structure converted the measured voltage into electric field to measure so the impedance is high.

Small impact on tested system. The measured signal is amplified by the internal process and finally directly visualized voltage value by LCD.
Operate quickly simple and clear.

Price and Minimum Quantity

Price: $770 - $15397
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Insulator Distribution Voltage Tester

Jun-10-21

Insulator Distribution Voltage Tester

$770 - $15.40K
MOQ: Not Specified
 
Application:

TK-15 insulator distribution voltage tester is used to test string of voltage distribution of AC circuit 35-500kV insulator. Insulator distribution voltage test meter also can do all kinds of 35kV and AC voltage measurement in laboratory. It is an ideal testing meter for the safety of line operation and the auxiliary tools for live operation.


Features:

This insulator voltage distribution tester use the static structure converted the measured voltage into electric field to measure so the impedance is high.

Small impact on tested system. The measured signal is amplified by the internal process and finally directly visualized voltage value by LCD.

Operate quickly simple and clear.
May-06-22
 
Product description

Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.

A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves).

The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment.



Technical Parameters

Input voltage AC220V 50 Hz

Output voltage 0~30kV

Capacity 3kVA

Test number 3 pairs each time

Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Jul-02-18
 
Scope
Test standards: ASTM D1816, ASTM D877.
This instrument uses special hardware and software anti-interference technology, it can work in a strong magnetic field environment, and widely used in power, oil and research departments.

Features
1. The instrument uses a microprocessor, three cups of whole, auto-complete boost, hold, stirring, static discharge, calculate, print and other operations, oil circulation pressure test can be carried out within 0-80KV range.
2, large-screen LCD, English menu, easy to operate.
3, this instrument is simple to operate, the operator simply simple setup, the instrument will automatically complete the 1-3 oil sample pressure test in accordance with the setting. Each oil sample, each cycle of breakdown voltage and frequency are automatically stored, after completion of the test, a thermal printer can print out the voltage value of each oil sample breakdown various times and average.
4, retentive, it can store 100 test results and can display the current ambient temperature and humidity.
5, using SCM control uniform boost, voltage frequency accuracy of 50HZ, making the entire process easy to control.
6, overvoltage, overcurrent, limit and other protection to ensure the safety of the operator.
7, having a temperature measuring and display function displays the system clock.

Technical Parameters
1, the test voltage: 0-80KV (optional)
2, the voltage distortion:
GOLD Member
Mar-28-23
 
Salisbury's Self-Testing Voltage Detectors allow testing to be continuous and automatic. An intermittent flash and beep confirms the detector is functioning properly. Self-Testing Voltage Detectors are used to verify live or de-energized conductors. These testers may be used with rubber insulating gloves or hot sticks using the splined universal end fitting. Testers indicate the presence of voltage with an extra bright LED light and a distinctive audible signal. It is recommended that the tester be moved closer to the conductor until a warning is indicated, or it touches the conductor, apparatus, or elbow test point. Each tester requires three C batteries (included).

Features & Benefits: Do not assume conductors that have been tested de-energized will stay de-energized. Always install proper grounding devices before working. Failure to do so may result in serious injury or death. Dimensions in. (mm): 11 x 3.5 ( 279.4 x 89 )
Aug-05-22
 
Product Introduction:
Lightning Protection Element Tester is suitable for testing the DC parameters of over-voltage protection components such as zinc oxide surge arresters (varistor) cermet two three-electrode discharge tubes and vacuum lightning arresters.


Product Parameters:

Varistor measurement
Technical index Measuring range Maximum error Test Conditions
Aug-13-22
Buyer From Coimbatore, Tamil Nadu, India
Dec-16-21
 
Overview

Light digital relay protection tester characteristics 4 6 8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850 9 1 2 frame format, Goose, IEEE 1588 packets more support 24 sets of SV packets 64 groups of Goose packets simultaneously 3 5 pairs of 2 10M fiber serial port, can send and receive IEC60044 7 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals



Technical parameter

Fiber Ethernet port
4 6 8 pairs 100 Mbits S, ST, Mode, 1310nm

IEC61850 9 1 2 Le, Goose, IEEE-1588

Send dispersion
Dec-15-21
 
Product description

Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.



Technical index




Electrical parameters

Accuracy class

0.05, 0.1

Resolution

6 TFT 640 480





Electrical parameters - continued

Power supply

220V 10%, 50 60Hz

Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh

Power line supply U1, UN, 85V-265V 50 60Hz

Communication port

RS232

Test voltage

Range

5-480V

Error

0.05% 30V-480V


0.1% 5V-30V

Harmonic

2nd-63st
Dec-24-21
 
Product Introduction
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.

This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.



Technical Parameters




Measuring range Dew point value 80 20
Moisture content 0 19999uLL
Accuracy of measurement 0.5 60 20
1.0 80 60
The resolution of the Dew point value 0.1
Moisture content 1uLL
Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20
63 needs 10s 90 needs 240s 20 60
Sampling flow 0.6L min 20
Pressure range 01.0Mpa
The use of temperature 20 60
Environmental humidity 0 100 RH
Storage temperature 20 80
Charging time 4 hours
The whole machine size 250 150 300mm3
The weight of The machine 3.5kg

Verification Status