Please click here to check who's online and chat with them.

Voltage Output Ac Current Clamp Sensor

Supplier From China
Nov-09-20

Model HQ15-A5 HQ15-A100
Rated primary current 5A AC 100A AC
Output Voltage 10 mV AC/A 1mV AC/A
Maximum input current 50A AC (Continuous) 130A AC (Continuous)
(45-66Hz,Ambient temp.50C)
Amplitude accuracy ±0.3%RD ±0.02%FS (10%-100%I1n),(45Hz- 66Hz)
Phase accuracy ±2 (10%-100%I1n)(45Hz-5kHZ)
The amplitude frequency characteristic ±0.1% (45Hz-5kHZ)(Deviation accuracy)
Conductor impact ±0.5 (Off-center)
The influence of external lectromagnetic fields 0.1A (In AC 400A / m electromagnetic fields)
Temperature coefficient ±0.02%/C of the reading data
Dielectric strength 3000 V AC rms/Continue 15 seconds(Circuits-iron core, iron core-shell)
The maximum rated voltage 300V AC rms
Applicable standards Safety: EN61010-2-032:2002,300V CAT III, Contamination II
EMC: EN61326:1997+A1:1998+A2:2001+A3:2003(Class A)
Mechanical parameters
Measurable conductor diameter Max.15mm
Cable length About 3m
Dimension (W x H x D) About 46135 21 (Excluding protruding parts)
Weight About 230g
Environmental conditions
Operating temperature 0 to 50 C (32-122 F)
Operating humidity 80%RH(No condensate)
Storage temperature -10 to 60 C (14-140F)
Storage humidity 80%RH(No condensate)
Operating environment Indoor, altitude up to 2000 meters

Price and Minimum Quantity

Price: $78
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Voltage Output Ac Current Clamp Sensor

GOLD Member
Feb-07-00
Supplier From Mumbai, Maharashtra, India
Oct-28-20
 
FEATURES
Suitable for 5A, 10A cable online measurement.
Holding wire diameter: 8mm
Dimension: 42.6mm 122.5mm 23mm
Load capacity: 4
Installation: clamp type
Output mode: lead output

PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%
Primary current 0 - 10A AC
Secondary current 0 - 10mA AC (customized)
Max. Cont. Input current 12 A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 10mA AC at nominal input current
Output signal (AC voltage) From 0 to 1V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 42.6 122.5 23
Weight (g) 225
Holding wire diameter (mm) 8
Max. jaw opening (mm) 8
Color Gray
Material PC+ABS+Polycarbonate, UL94 V0
GOLD Member
VERIFIED
Nov-21-20
Supplier From New Delhi, Delhi, India
GOLD Member
VERIFIED
Oct-19-20
Supplier From Seoul, South Korea (Republic Of Korea)
Nov-03-20
 
FEATURES
Suitable for 10A-200A cable online measurement.
Holding wire diameter: 20mm
Dimension: 52.5mm137.5mm28mm
Load capacity:
Installation: clamp type
Output mode: lead output

PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.1%, 0.2%
Primary current 0 - 200A AC
Secondary current 0 - 200mA AC (customized)
Max. Cont. Input current 240A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 200mA AC at nominal input current
Output signal (AC voltage) From 0 to 2V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28
Weight (g) 400
Holding wire diameter (mm) 20
Max. jaw opening (mm) 20
Jaw color Red, yellow, blue, green, black
Material PC+ABS+Polycarbonate, UL94 V0
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
GOLD Member
VERIFIED
Oct-02-20
Supplier From Singapore, Singapore, Singapore
GOLD Member
Feb-18-21
 
Product description

VFD for biomass burner, biomass gasification burner. For electric cabinet frequency and voltage converting, to meet different countries voltage. Ensure the bioamss burner can work well.
Jul-16-15

Hall Current (Voltage) Sensor

$0.50 - $500
MOQ: Not Specified
 
Hall components have many advantages, they are strong construction, small volume, light weight, long service life , easy installation, wide bandwidth ( can reach 1 MHZ);vibration resistance, Not afraid of pollution or corrosion of dust ,oil, greasy dirt, moisture , salt mist and so on.

• Hall linear elements are excellent accuracy, good linearity. Hall switch elements are no contactless, no in-gage, clear output waveforms, no instant jitter, high-precision positional repeatability.

In recent years, with the development of China aerospace industry .Our hall-effect product is widely used in new rocket ,new generation communication satellite, new navigation satellite, new recoverable satellites, chang-e satellites, Shenzhou spacecraft and so on . Its related products is also can widely used in automotive matching, environmental protection, medical equipments, instrument, power protection, office automation and many other civil fields.

It is wildly used in frequency driver, contravariant devices, UPS, contravariant welding machine, converting station, electrolyze & electroplating, CNC machine, PC monitoring, grid monitoring, insulated current & voltage testing, Etc.

Working Principle
1.Direct measurement principle
2.Magnetic compensation principle


Packed in box ,can be customized

Verification Status