VFD for biomass burner, biomass gasification burner. For electric cabinet frequency and voltage converting, to meet different countries voltage. Ensure the bioamss burner can work well.
RS-232C communication function expansion board. Series Name: f920got with keys, with a series of effective functional modules. System screen display language: English. Display: 2.6 inches.
Display color: monochrome (blue / white) fr-a8nc parameter setting tutorial. Display device: STN LCD Resolution: 128X64 points. Installation type: panel installation.
Built in communication port: RS-422 (1ch) / RS-232C (1ch) fr-a8nc power supply voltage: DC5V.
Touch screen refers to the field or interface where people and machines contact or interact in information exchange and function. The man-machine interface refers to the hard contact and soft contact between people and machines,
This joint surface includes not only the direct contact between points, lines and surfaces, but also the function space of long-distance information transmission and control, fr-a8nc parameter setting tutorial.
The man-machine interface is the central link in the man-machine system,
It is mainly studied and put forward the basis for solution by safety ergonomics, a branch of safety engineering, and has passed safety engineering and equipment engineering,
Safety management engineering and safety system engineering to study specific solutions and measures safety ergonomics fr-a8nc parameter setting tutorial. RS-232C through adapter. (fx1n-cnv-bd is required).
(common to fx1s and FX1N hosts). It can be isolated from the output of programmable controller for a / B / C contact relay, SSR and tr output. Input points: 14 points.
Output points: 10 points fr-a8nc (type selection data). Power supply voltage: AC100-240V. Output type: relay output.
Built in CPU, power supply, input and output. Improve performance while maintaining FX1N convenience. Fx3 series special adapter and function expansion board can be installed. High speed operation processing.
Basic instruction: 0.21us/instruction. Application instruction: 0.5us/instruction. Large capacity memory.
There are 32000 steps of fr-a8nc in the internal program memory (type selection reference material).
EEPROM memory box with program transfer function can be used. Input and output points: 16 points. Input points: 8 points. Input specification: drain type. Output points: 8 points.
Output form: relay output. Power consumption: 6W. Weight: 0.25kg.
Overall dimension: 34x90x87mmfr-a8nc (type selection data). The third generation micro programmable controller of jiancuo type. Connector type input / output type economizer.
It has greatly strengthened the high-level built-in functions such as high-speed processing and positioning in the industry. Space saving model with high cost performance.
Fx3uc not only saves space and wiring, but also greatly strengthens the internal harm functions such as high-speed processing and positioning. The host has built-in DC24V power supply and transistor output in the form of connector input and output.
Supplier: AC and DC current-voltage switch-plate meter and lever meter as well as installation type electric meter accessories and SSR series solid state relay, SCR power regulator
Qx80h is q series DC high-speed input module, negative common terminal type, 16 points. Qx80h price (face price), the market stock is very small.
Qx80h Parameter Description: 24VDC / 4mA, common cathode, 16 points, terminal block (high speed).
Specification details of PLC module qx80h:
DC input module negative common end
input points 16 points
isolation method Optocoupler
rated input voltage DC24V 20% - 15%, ripple coefficient above 5%)
rated input current about 6mA
derating chart
on voltage / on current 13V or higher / 3mA or higher
off voltage / off current 8V or less / 1.6mA or less
function setting SW2 off interrupt, on high speed input
dielectric withstand voltage 560vac MS / 3 cycles (altitude 2000m (6557.38 feet))
[insulation resistance] 10m or higher measured by insulation resistance tester
through 1500vp-p noise voltage, 1 Voice simulator with s voice width and 25 to 60Hz voice frequency
First instantaneous voice iec61000-4-4: 1kV
protection grade IP2X
common terminal arrangement 8 points / common terminal common terminal: tb9, tb18
I / O points 16 I / O allocation is set to 16 point high-speed input module or interrupt module
working status indicator set by setting in GX developer switch
running indicator on indication (LED)
external connection 18 point terminal block (M3 6 screw)
applicable wire diameter core 0.3mm2 to 0.75mm2 (maximum outer diameter 2.8mm)
applicable to clamping terminal R1 25 ~ 3 clamping terminal with sleeve cannot be used
5VDC internal current consumption 80mA standard: all points on
overall dimension h w d 98 * 27.4 * 90 mm
weight 0.16kg
Supplier: Electrical power products for power supply systems, Automatic voltage regulators ( AVR), Uninterruptable power suppliers (UPS), Inverters (INV), Modified power inverter, pure sine wave inverter, grid tie inverter, solar panel, Emergency power source (EPS), Battery chargers, Intelligent circuit breaker, LED light and transformers
Power input Rated voltage 3-phase AC220V/AC230V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V
1-phase
AC220V/AC230V
Rated input current See Section 2.3 in user manual
Frequency 50Hz/60Hz, acceptable fluctuation range ¡¨¤5%
Allowable range of voltage Continuous voltage fluctuation ¡¨¤10%, short fluctuation -15%~+10%, i.e. 323V~528V;
Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC61800-2
Power output Standard applicable motor (kW) See Section 2.3 in user manual
Rated current (A) See Section 2.3 in user manual
Output voltage (V) 3-phase: 0~ rated input voltage, Bias < ¡¨¤3%
Output frequency (Hz) 0.00~ 600.00Hz; unit: 0.01Hz
Overload capacity 150% - 1min; 180% - 10s; 200% - 0.5s once per 10 minutes
Operation characteristics Control mode V/f control
Sensor-less vector control without PG 1
Sensor-less vector control without PG 2
Range of speed regulation 1:100 ( V/f control, sensor-less vector control without PG 1)
1:200 (sensor-less vector control without PG 2)
Speed accuracy ¡¨¤0.5% (V/f control)
¡¨¤0.2% (sensor-less vector control without PG 1 & 2)
Speed fluctuation ¡¨¤0.3% (sensor-less vector control without PG 1 & 2)
Torque response < 10ms (sensor-less vector control without PG 1 & 2)
Starting torque 0.5Hz: 180% (V/f control, sensor-less vector control without PG 1)
0.25Hz: 180% (sensor-less vector control without PG 2)
Basic functions Start frequency 0.00~ 600.00Hz
Acceleration/deceleration time 0.00~60000s
Carrier frequency 0.7kHz~16kHz
Frequency command source Digital command + operating panel ¡Ä/¡Å
Digital command + terminal UP/DOWN
Communication
Analog command (AI1/AI2/EAI)
Terminal pulse command
Motor Started method Started from starting frequency
DC braking and then started
Speed search then started smoothly
Motor Stopped method Ramp to stop
Coast to stop
Ramp stop + DC brake
Basic functions Dynamic brake capacity Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake unit for GK600-4T45G/55L or below could be internally mounted
DC brake capacity DC brake start frequency: 0.00~600.00Hz
DC brake current: 0.0~100.0%
DC brake time: 0.0~30.00s
Input terminals Six digital input terminals (can be extended to 7), one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input
Two analog input terminals, one of which is voltage/current programmable, and the other is voltage only (can be extended to 3; extension terminal is voltage/current programmable)
Output terminal One high-speed pulse output terminal, 0~50kHz square wave signal output; can output signals such as setting frequency and output frequency. etc
One digital output terminal
One relay output terminal (can be extended to 2)
One analog output terminal (can be extended to 2), voltage/current output optional; can output signals such as setting frequency and output frequency, etc
Characteristics Parameter copy, parameter backup, common DC bus, free switching between two motors¡¡¥ parameters, flexible function code displayed & hidden, various main & auxiliary command and switchover, speed searching, a variety of acceleration/deceleration curves optional, automatic correction of analog value, mechanical brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), swing frequency control programmable, fixed-length control, counting function, three faults recorded, over excitation braking, over voltage stall prevention, under voltage stall prevention, restart upon power off, hopping frequency, frequency binding, free switching between four sections of acceleration/deceleration time, motor thermal protection, flexible fan control, process PID control, simple PLC, flexible multi-functional key setting, droop control, parameter identification, weak magnetic control, high-precision torque restraint, V/f separated control
Protection function Refer to Chapter VII - Fault Diagnosis and Abnormity Handling
Environment Place of operation Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drip or salt content etc.
Altitude 0~2000m
Derating is required where altitude is more than 1,000m; each increase of 100m in height corresponds to a decrease in rated output current by 1%
Ambient temperature -10¡ãC~50¡ãC
Humidity 5~95%, condensation not allowed
Vibration Less than 5.9m/s2 (0.6g)
Storage temperature -40¡ãC~+70¡ãC
Others
Efficiency Rated power
7.5kW and below: ¡Y93%
11~ 45kW: ¡Y 95% 55kW and higher: ¡Y98%
Installation mode Wall-mounted
Protection level IP20
Cooling mode Forced air cooling
Country of Origin: China (Mainland) Guangdong
Brand: GTAKE
Model: as type
Output power: other
0.4KW-800KW
Output type: Triple
Size: as model
Weight: as model
Input voltage :208V/220V/230V/380V/400V/415V/440V/460V/480V
Output: 0-rated input voltage
Type: AC/AC, or DC/AC inverters
Output frequency: 0.00-600.00Hz
Output current: as model
Input terminals: DI-7(HDI-1), AI-3 0~10V, or 0-20mA
Output terminals: DO-2(HDO-1), RO-2, AO-2
Certificate: CE, GOST
Applying motor: Asynchronous motor and synchronous motor
Cooling: Air cooling
IP grade: IP20
Input voltage: AC, or DC
Frequency command source:Keypad, terminals, communication
Communication: Modbus, Profibus-DP, CANopen, CAN
Control technique: V/f, SVC1, SVC2
Supplier: Gas stoves, hot plates, blender, extension leads, sockets, switches, floodlights, night lights, plug in doorbell, B & O doorbell, LED bulbs, christmas projector light heaters poundlines dollar items shower heads tools Services: Exporter, manufacturing