High speed dental turbine handpiece, developed with care by our technical stuff, is a new type of handpiece
Combining characteristics of many styles of handpieces. It is fine in its appearance, precise in its structure, reliable in its usage and has the advantages of low running noise, good vision and high running speed.Its hand grip is comfortable and easy to clean and maintain, in addition, this handpiece is easy to lubricate and also can be sterilized under high temperature. It is the first choice for dental treatment cente.
4-hole and 2-hole connection with fast join push button high quality axletree max speed 350, 0000-400, 000 r.P.M.
Washable(thermal disinfector) recommended air pressure: 2.5 kg
Low speed handpiece
Specifications/advantages:
Adjustable r.M.P up to 22, 000
Operating air preassure 29 to 40 psi
Low noise, vibration free
Fullu autoclavable
Lighrweight
Forward & reverse drive
Can us the air motor with any iso
E-type contra angle
Long life cycle
Standard configuration
High speed handpiece (4holes)------2sets
Low speed handpiece (4holes)-------1set
3-way syringe (cold and hot)-------2sets
High suction--------------------1set
Saliva ejector------------------1set
Automatic cup filler--------------1set
Operation light-----------------1set
Integral cuspidor----------------1set
Clean water system--------------1set
Motor-driven dental chair---------1set
Operator stool-----------------1set
Specfications
Voltage ~220v 50hz
Water pressure 200~400kpa
Air pressure 550~800kpa
Gross weight 330kg
Option
Air compressor
Ultrasonic scaler
Led curing light
Character
Need not to make adjustment automatically, high precise
Be use of high integration agglomerate, function all in single integration
Agglomerate, to realize computerized.
It is not necessary to make any adjustment according to different patients.
Automatic calibration ensures accuracy and eliminates the effect of changes
In temperature, moisture, etc. Inside the canal, even during the treatment.
With two kinds of different frequency signal, precise measurement results,
Irrespective of dry or bleeding purulence in the root canal.
Precise measurement results, although it's filled with naclo2,
Physiological saline, h2o2, water, etc.
Irrespective of kinds of teeth, size of root tip, thickness of root canal file.
Exact visualization of the file tip position on large color display
High precise, high contrast large color display
To make position of root canal file the same as indicator bar, adopts large
Lcd display with exact visualization.
Set shining position of root tip arbitrarily, to as length sign during operation.
Can be sterilized by autoclave
Dapper root file holder
Root canal holder, contrary electrode can be sterilized by autoclave.
With dapper holder, it's convenience for dentist during operation.
Normally click collect on root canal file to measure, or if root canal file get
To the side of holder front
Contact point of root canal file is made by high quality metal
Specification
Power voltage:dc7.5v(5*dc 1.5v aa alkali dry cells)
Power consumption: below 0.135va
Test voltage:below ac80mv
Test electric current: below 10ua
Display: reflex colored lcd display, buzzer
Dimensions: w105*d105*h115mm
Weigh: about370g
Spare parts
Probe cord 1pcs
File holders 5pcs
Contrary electrodes 3pcs
1. When adding up voltage, total current is less than 2a and total power is 500w;
2. The current and voltage of x-ray tubes are fixed in three groups, they are:
X exposure voltag (kvp) 60 65 70
X-ray current (ma) 0.5 0.85 1.10
3. When adding up voltage, total current is less than 2a and total power is 500w
4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1
5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable.
6. Wireless remote control in any angles within 10 meters part form the control box
7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes
A focus index: 0.3*0.3mm2
B. The voltage of the-highest-voltage generator: 90kv
C. The highest inverse peak voltage: 90kv
D. Filament characteristic: vf=5v+0.5v, f=3a
E. Target surface obliquity: 12
F. The cooling manner of bulb tube head: oil immersion
The parameter of x-ray generator (bulb tube head):
A. Focus-skin distance: 200mm
B.The thickness of filter-ray film: more than 1.5mmal
C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h)
D. The manner of limiting beam: using planigraphic device