Infusion pump

Specifications
Controls:
Drop counting and adjusting the delivery rate automatically
Pump type: peristaltic finger
Applicable iv sets:
Various iv sets(including lucifugal iv sets)
Accuracy:
25drop/min:2%, >25drop/min:3% (used in the drop counting control way)
5% (used in the volumetric control way with the correct calibration)
Delivery rate range:
1½400drop/min(1drop/min step)
1.0ml/h½1200ml/h (1.0ml/h½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery time range: 1min½1999min (1 min step)
Volume limit range: 0½9999ml (1 ml step)
Total volume range: 1½9999ml (1 ml step)
Purge rate: 600ml/h
Kvo rate:
When the delivery rate 10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h.
Alarms:
Air-in-line, infusion complete(a volume limit has been set), empty container, occlusion, door open, over time, no drop sensor, operation error, low battery and other device failures.
Power source:
Ac power supply: ac 100 to 240v10%ú¼50/60hzú+
Internal li battery: 11.5v, 2000mah. Battery life with continuous operation is approx. 8 hours (when using a new, full charged battery and running at 20drop/min with any standard of iv set).
Power consumption: 25va
Shock protection: classó, type bf



Dimensions: 130mm 200mm 230mm


Jul-28-08

Syringe pump

Characteristics
Can be used with any standard syringe.
Can identify the dimensions of syringe automatically.
Has a broad range of delivery rate setting.
Has a unique color lcd and an internal battery with a high capability .
Has a three modes of the infusion: rate mode, time mode and body weight mode.
Can be set at any of three levels of alarm volume: high, medium and low.
Can be set at any of three levels of maximum pressure: high, medium and low.
Kvo functionafter infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus.



Dimensions: 280mm160mm130mm
Net weight: approx. 3.5kg


Double channel syringe pump

Specifications
Applicable syringe:
Any standard syringe with 10mló20ml(30ml)and 50ml(60ml)
Accuracy: 2% (after the correct calibration)
Delivery rate range:
50ml(60ml)¦0.1ml/h½1800.0ml/h (0.1ml/h step)
20ml(30ml)¦0.1ml/h½800.0ml/h (0.1ml/h step)
10ml¦0.1ml/h½400.0ml/h (0.1ml/h step)
Time mode range:
Sol.Vol.¦0.1½999.9ml (0.1ml step)
Time¦1½1999min (1min step)
Body weight mode range:
Sol.Vol.¦0.1½999.9ml(0.1ml step)
Drug mass¦0.1½999.9mg(0.1mg step)
Dose¦0.01½99.99ug/kg/min(0.01ug/kg/min step)
Weight¦0.1½300kg(0.1kg the least step)
Volume limit range: 0½1999.9ml (0.1 ml step)
Total volume range: 0.1½1999.9ml (0.1 ml step)
Purge rate: 50ml(60ml)¦1800.0ml/h, 20ml(30ml)¦800.0ml/h, 10ml¦400.0ml/h
Kvo rate: 1ml/h
Alarms: near empty, syringe empty, volume complete(a volume limit has been set), occlusion, syringe loose, operation error, low battery and other device failures.
Power source:
Ac power supply: ac 100 to 240v10%¼50/60hz+
Internal li battery: 11.5v, 2000mah. Battery life with continuous operation is approx. 8 hours(when using a new, full charged battery and running at 5ml/h with any standard of syringe).
Power consumption: 25va



Dimensions: 300mmß240mmß250mm
Net weight: approx. 3.5kg


 
 
Contact Supplier
Renew

Verification Status