- Quantum Efficiency Testing System: 300nm-1100nm (expandable to 2500nm)
- Software: PDSW software, Upgradable to FETOS-SW (3T or 4T devices)
- Probe Station System (option): 4â??standard probe station (MPS-4-S)
- Customized integration solution combining probe stage and shielding dark box.
Application
- Optical Sensor in LiDAR - InGaAs Photodiode / SPAD
- Photosensor of APPLE Watch
- Photodiode-gated Transistor for high gain sensing and imaging
- Highly-sensitive indirect-conversion X-ray Detector characterization
- High Photoconductivity Gain and Fill-Factor Optical Sensor
- Silicon Photonics
Specification
- Three independent white light sources with different color temperatures:
3000K +/- 500K
4000K +/- 500K
5500K +/- 500K
- User can define the output light color temperature
Manual and continuous adjustment of light intensity
Illumination intensity: 250 Lux - 1000 Lux
Illumination area: 100mm x 100mm
Uniform area: >95%@ 50mm x 50mm
>90%@ 100mm x 100mm
Application
- PV characterization under indoor light environment
Specification
- Output Beam Size: 50x50, 100x100, 160x160, 180x180, 200x200, 220x200mm2
- Working Distance: 250mm, 300mm, 500mm, 400mm
- Flexible Output Directions: up-to-down, bottom-up, right & left
- Xe Power Supply, RS232 Port, 3.5â??color-touch-panel
- Enlitech provides the worldâ??s most types of reference cells which comply with the WPVS type and IEC 60904 standards
- Can be controlled by the IVS-KA6000 software
Application
- Perovskite Solar Cell Efficiency measurement
- Organic Solar Cell Efficienty measurement
- Perovskite / Si Tandem Solar Cell Efficiency measurement
- Ideality Factor n test
- Sun-Voc test
- Water Splitting Cell test
- HJT, PERC, TOPCon Si Solar Cell test
Specification
- 4 illumination modes: up, down, left and right. Light can be emitted in four directions.
- Spectrum Range: 300~1800 nm
- Automatic Shutter on/off
- Compatible with IVS-KA6000 + KA Viewer, the most powerful measurement and analysis software
- Modetls:
SS-ZXR100 : 100x100mm2 Spot Size, 30cm working distance.
SS-ZXR160 : 160x160mm2 Spot Size, 50cm working distance.
SS-ZXR180: 180x180mm2 Spot Size, 50cm working distance
Application
- Silicon solar cells for space
- Organic solar cells
- Perovskite solar cell
- Concentrator Photovoltaic
- Aging tests for solar cells
Specification
- Illumination Area : 100x100mm2
- Spectrum Range : 300 ~ 1700 nm
- Spectrum : A++
- In-stability : A+
- Uniformity : A
- Reference Cell (option) : KG3 for Perovskite Top / BL7 for Si Bottom
- Spectrometer (option) : HS-IL
- Achieve the spectral level of dual lamp system (xenon lamp plus halogen lamp)
- 100% SPC and better SPD
Application
- Accurate measurement of perovskite/crystalline silicon tandem solar cells
Specification
- Super A+ spectrum from Visible wavelength range to NIR wavelength range.
- Light intensity range: 0.01 sun to 1 sun (1mW/cm2 to 100mW/cm2 or 1k lux to 100k lux)
- Computer controlled light intensity output
- Beam size: 100mm x 100mm
- Beam un-uniformity:
Specification
- PD-QE has different modules, and the bias voltage range can be from 20 V to 1000 V.
At the same time, the measuring resolution of photocurrent is very high (10-16 Amp achievable).
- Wavelength extension up to 1800 nm
- Option: Software upgradable for controlling Keithley 4200 SMU
Application
- OPD (Organic Photodiode)
- PPD (Perovskite Photodiode)
- QDPD (Quantum Dots Photodiode)
- New generation Photodiode
Specification
- Lamp Wavelength Range: 250nm-2500nm
- Measuring Wavelength Rane: 300nm-1100nm, 300nm-1800nm, 300nm-2500nm
- Un-Repeatability:
Specification
- Lamp Wavelength Range: 250nm-2500nm
- Measuring Wavelength Rane: 300nm-1200nm
- Un-Repeatability:
Specification
- Omnidirectional light receiving system (100 mm integrating sphere)
- Enhanced Multi-Channel Spectrometer Test System
- Photoluminescence measuring module (365 nm LED excitation light source)
- Software
- IPC & monitor
- Optional: EL spectrum testing module
- Optional: Infrared Spectrum Expansion Module (900 â?? 1700 nm)
- Optional: Glovebox integration kit, Excitation light source
- Optional: LED light source (Wavelength: 385 nm / 405 nm / 430 nm / 470 nm / 532 nm)
- Optional: Laser light source (Wavelength: 375 nm / 405 nm / 532 nm)
Application
- Phosphor
- LED fluorescent material
- OLED fluorescent material
- Perovskite
- Laser dies
- Perovskite quantum dot powder and single crystal
- PbS quantum dot
- Visible and infrared absorbing dyes
Specification
- Omnidirectional light receiving system (50 mm integrating sphere)
- Enhanced Multi-Channel Spectrometer Test System
- Probe System
- Software
- IPC & monitor
- Optional: Infrared Spectrum Expansion Module (900 â?? 1700 nm)
- Optional: Glovebox integration kit
Application
- Perovskite LED / Perovskite Laser Diode
- Organic IR LED
- QD LED / QD Laser Diode
- VESEL Laser Diode
Specification
- Full-spectrum wavelength range: 300-1100nm or 350-1000nm (PTC)
- Wavelength range can be extented to 1700nm or more.
- Single wavelength source: 470nm, 530nm, 630nm, 940nm (+/-5nm) or customized
- Dynamic Range: 80dB ,100dB, or 140dB
- Test fixtures: DUT
Specification
- Spactral Range: 400nm to 1700nm
- Color Contrast Temperature: 3000K to 5200K
- Area of Uniform Illumination: 42mm x 25mm at >200mm working distance
- Uniformity of Illumination: better than 98%
- Short Term Light Instability:
Specification
- High stable Xe white light source:
Color temperature: 5,500k - 6,000K
Optical instability =250 lux
Green light: peak@550nm+/-5nm; >=300 lux
Blue light: peak@475nm+/-5nm; >=100 lux
- White light intensity: >= 8,000 lux
- Light intensity adjustment:
0~100% with 0.1% resolution
Max 4-order light intensity dynamic range
Application
- Optical Fingerprint Sensor testing
- Development of Fingerprint Recognition Algorithm in ISP Chip
- Sensor Properties test and analyze
- Analyze the image qualities of the Optical Sensor Module