DESCRIPTION: RPC-WELD CPVC is an orange, heavy bodied, high strength, medium setting CPVC solvent cement for all classes and schedule. This cement is manufactured in the India.
APPLICATION: RPC-WELD CPVC is for use on all grade CPVC pipes and fittings. This cement may be used for potable water, irrigation drain, waste, vent, sewer and conduit. This cement can be used for HOT and COLD water applications.
PROPERTIES AND SPECIFICATIONS:
Color Orange
Appearance Liquid
Set TimeFast Medium
Cure Time Consult ASTM schedule
Exceeds ASTM F- 493 specification
Shelf Life 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units/case Units/ master
59 ml 24 192
118 ml 24 144
237 ml 24 96
473 ml 12 48
946 ml 6 24
DESCRIPTION: King PVC Solvent is a clear, medium bodied, high strength, fast setting PVC solvent cement for all classes and schedule. This solvent cement is manufactured in the India.
APPLICATION: King PVC Solvent is for use on PVC pipes and fittings. This cement may be used for upto 4â??â?? pipes and fittings with interference fit for potable water, irrigation, drain, waste, vent, sewer and conduit applications.
PROPERTIES AND SPECIFICATIONS:
Color: Clear
Appearance: Liquid
Set Time: Fast
Cure Time: Consult ASTM schedule
Exceeds: ASTM D2564 specification
Shelf Life: 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units / case Units/ master
59 ml 24 192
118 ml 24 144
237 ml 24 96
473 ml 12 48
946 ml 6 24
DESCRIPTION : RPC-WELD PVC Solvent is a clear, heavy bodied, high strength, fast setting PVC solvent cement for all classes and schedule. This solvent cement is manufactured in the India.
APPLICATION : RPC-WELD PVC Solvent is for use on PVC pipes and fittings. This cement may be used for all grade pipes and fittings irrespective of diameter with interference fit for potable water, irrigation, drain, waste, vent, sewer and conduit applications.
PROPERTIES AND SPECIFICATIONS:
Color: Gray
Appearance: Liquid
Set Time: Fast
Cure Time: Consult ASTM schedule
Exceeds: ASTM D2564 specification
Shelf Life: 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units / case Units/ master
50 ml 24 192
100 ml 24 144
200 ml 24 96
250 ml 24 96
500 ml 12 48
1000 ml 6 24
DESCRIPTION: RPC-WELD PVC Solvent is a clear, heavy-bodied, high strength, fast setting PVC solvent cement for all classes and schedule. This Solvent cement is manufactured in the India.
APPLICATION: RPC-WELD PVC Solvent is for use on PVC pipes and fittings. This cement may be used for all grade pipes and fittings irrespective of diameter with interference fit for potable water, irrigation, drain, waste, vent, sewer and conduit applications.
PROPERTIES AND SPECIFICATIONS:
Color: Clear
Appearance: Liquid
Set Time: Fast
Cure Time: Consult ASTM schedule
Exceeds: ASTM D2564 specification
Shelf Life: 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units / case Units/ master
50 ml 24 192
100 ml 24 144
200 ml 24 96
250 ml 24 96
500 ml 12 48
1000 ml 6 24
DESCRIPTION : RPC-WELD PVC Solvent is a clear, heavy bodied, high strength, fast setting PVC solvent cement for all classes and schedule. This solvent cement is manufactured in the India.
APPLICATION: RPC-WELD PVC Solvent is for use on PVC pipes and fittings. This cement may be used for all grade pipes and fittings irrespective of diameter with interference fit for potable water, irrigation, drain, waste, vent, sewer and conduit applications.
PROPERTIES AND SPECIFICATIONS:
Color: Clear
Appearance: Liquid
Set Time: Fast
Cure Time: Consult ASTM schedule
Exceeds: ASTM D2564 specification
Shelf Life: 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units/Case Units/ master
50 ml 24 192
100 ml 24 144
200 ml 24 96
250 ml 24 96
500 ml 12 48
1000 ml 6 24
DESCRIPTION : RPC-WELD PVC Solvent is a clear, heavy bodied, high strength, fast setting PVC solvent cement for all classes and schedule. This solvent cement is manufactured in the India.
APPLICATION: RPC-WELD PVC Solvent is for use on PVC pipes and fittings. This cement may be used for all grade pipes and fittings irrespective of diameter with interference fit for potable water, irrigation, drain, waste, vent, sewer and conduit applications.
PROPERTIES AND SPECIFICATIONS:
Color: Clear
Appearance: Liquid
Set Time: Fast
Cure Time: Consult ASTM schedule
Exceeds: ASTM D2564 specification
Shelf Life: 3 years
Raw Materials from U.S.A
AVAILABILITY:
Size Units / case Units/ master
59 ml 24 192
118 ml 24 144
237 ml 24 96
473 ml 12 48
946 ml 6 24
RPC-WELD PVC solvent cements have passed the following tests performed according to ASTM Standard D2564
Test Pressure
2 hour Hydrostatic Burst Test 400 psi
2 Hour Lap Shear Test 250 psi
16 Hour Lap Shear Test 500 psi
72 Hour Lap Shear Test 900 psi
DIRECTIONS:
Keep container close when not in use
Set time is the time required before joint can safely be handled.
Cure time is the time required before joint can be pressure tested
1. Cut pipe square with saw or hand cutter. Remove all burrs.
2. Check dry fit of pipe and fitting. Pipe should easily go to way into fitting. If pipe bottoms into fitting
it should be very snug.
3. Pipe and Fitting should be free of dirt, grease and other foreign materials. If necessary clean pipe and
fitting using RPC-WELD Pipe Cleaner. Primer is highly recommended for 3 and larger diameter installation.
Apply liberal coat. Primer will start softening surface of pipe and fitting thus ensuring superior joint.
4. Use applicator supplied with the can or suitable applicator at least the size of the pipe diameter
5. Apply liberal coat of cement to the pipe (equal to depth of fitting) and adequate coat inside of fitting.
Make sure there is no uncoated surface. Avoid puddling of cement, it may weaken the joint.
6. Immediately insert pipe into fitting with twisting motion. Cement should be wet. If it has dried recoat both parts.
Use sufficient force to ensure pipe bottoms into fitting.
7. Hold joint together for 30-40 seconds to make sure pipe is not pushed out longer time if temperature is low
and for larger pipes.
8. Allow 15 minutes set time before handling the assembly and 2 hours cure time if temperature is below 60 F.
Longer cure time may be required for larger pipe and /or if temperature is below 60 F.
Do not test with compressed air.
DIRECTIONS FOR USE:
- Shake well before using.
- Keep container closed when not in use.
- Set time is the time required before joint can safely be handled.
- Cure time is the time required before joint can be pressure tested.
1. Cut pipe square with saw or hand cutter. Remove all burrs.
2. Check dry fit of pipe and fitting. Pipe should easily go A1/A3 to A1/A2 way into fitting. If pipe bottoms into fitting it should be very snug.
3. Pipe and Fitting should be free of dirt, grease and other foreign materials. If necessary clean pipe and fitting using RPC-WELD Pipe Cleaner. Primer is highly recommended for 3 and larger diameter installation. Apply liberal coat. Primer will start softening surface of pipe and fitting thus ensuring superior joint.
4. Use applicator supplied with the can or suitable applicator at least A1/A2 the size of the pipe diameter.
5. Apply liberal coat of cement to the pipe (equal to depth of fitting) and adequate coat inside of fitting. Make sure there is no uncoated surface. Avoid puddling of cement, it may weaken the joint.
6. Immediately insert pipe into fitting with twisting motion. Cement should be wet. If it has dried recoat both parts. Use sufficient force to ensure pipe bottoms into fitting.
7. Hold joint together for 30-40 seconds to make sure pipe is not pushed out longer time if temperature is low and for larger pipes.
8. Allow 15 minutes set time before handling the assembly and 2 hours cure time if temperature is below 16 C or 60 F Longer cure time may be required for larger pipe and /or temperature is below 16 C or 60 F.
Description:
VCOLD is a rapid-setting structural repair mortar. It is designed primarily for the durable repair of concrete. Utilising all the latest technology this Portland cement-based and fibre-reinforced product is extremely strong and hard wearing. This makes it ideal for roads, runways, bridges, decks, floors and footpaths. Requiring only the addition of water, this single component mortar is rapid curing.
VCOLD quick set mortar is physically and chemically compatible with the host concrete. This means it is quick to exhibit a high adhesive and compressive strength.
Product name: VCOLD
Compressive strength
- 35 Mpa, in 6 hours
- 50 Mpa, in 1 day
- 80 Mpa, in 1 week
Application temperature
- In cold temperatures, tepid water may be used to adjust working life
- In 20-40 temperatures, cold water should be used to adjust working life
Mixing ratio:
- 25kgs powder: 3,7L water
- 5kgs powder: 0.7L water
Uses of VCOLD
VCOLD is used on floors that are subjected to heavy wear such as:
- Roads
- Runways
- Bridges
- Decks
- Floors
- Footpaths
The repair mortar can be used as supplied up to 100mm deep. It can also be bulked out with clean, washed, sharp sand to form a high performance screed or for floor or deck repairs up to maximum depth of 300mm.
One barrel 25kgs of VCOLD produces 13 litres
Applying VCOLD Rapid Set Repair Mortar:
VCOLD should only be installed by those experienced in structural waterproofing. Please follow manufacturerâ??s instructions for full details across the range of applications.
Preparation â?? Start by mechanically removing all damaged concrete back to a sound core. Ideally you want to expose the steel reinforcement to at least 25mm behind the bars and 50mm beyond the point at which corrosion is visible.
The perimeter of the repair area should be stepped to a depth of 10m using a saw, disc cutting or preferably a power chisel.
Make sure that all areas to be repaired are free from dust, oil, grease, corrosion by-products and all organic growth. Any smooth surfaces should be roughened with any surface laitance removed.
You should now thoroughly soak the prepared surface with clean water until uniformly saturated. Ensure there is no standing water.
Mixing:
Mechanically mix VCOLD using a forced action pan mixer or in barrel using a drill and paddle.
Normal applications = typically use 3,7 litres of clean water per 25kgs barrel
Normal applications = typically use 0.7 litres of clean water per 5kgs barrel
Note:
- In cold temperatures, tepid water may be used to adjust working life
- In 25-40 temperatures, cold water should be used to adjust working life
Important Note:
The product cannot be mixed using a normal concrete mixer. Pot life is about 10 minutes, depending on the temperature and humidity. For screeding applications or deep repairs consult technical sheets.