Jul-14-09
Supplier : Earth resistivity meters, geophysical equipments digital resistivity meters, aquameter CRM

Established: 1980

Verification Status



Contact Details:
Lane No. 1
Dahanukar Colony
Kothrud
Prasad Apt.
Pune 411029
Maharashtra India


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Anvic Systems

Jul-14-09

Earth Resistivity Meter

$3.00K
MOQ: Not Specified
Supplier From Pune, Maharashtra, India
 
Depth of Investigation v 400 meters

a. Transmitter

1) Constant Current Selected automatically depending on
ground conditions
Max. Current 500mA
Min. Current 1mA
2) Voltage (Max) 500 V (1000 Vpp)
3) Power 40W

b. Amplifier
Voltage Measurement
Input Impedance 10 M Ohm
Input Range 0-200V
Precision + 0.05 mV
Noise Rejection 95 dB at 50-60 Hz

c. Resistance Measurement
Apparent R Range m Ohm, Ohm, K Ohm
Apparent R Precision 0.02 m Ohm at 500 mA

d. System Data
Cycle time 12 seconds
Accuracy 2%
Diagnostic display 9 codes
Temp. Range 0 v 50 degree c

e. Power Source 12 Volt, 12 Ah Rechargeable Battery
Measuring capacity 2000 readings at 20 mA
200 readings at 500 mA

f. Weight 12.5 Kg

g. Dimensions L 400mm X W 225mm X H 330mm



Weight 20 kg of instrument Additional Accessaries 60-80 Kg.
GOLD Member
VERIFIED
Nov-21-20
Supplier From New Delhi, Delhi, India
GOLD Member
VERIFIED
Oct-28-24
Supplier From Peshawar, KPK, Pakistan
VERIFIED
Jan-19-22
Supplier From Chakan, Maharashtra, India
 
flow meter
GOLD Member
Dec-15-23
Supplier From Dubai, United Arab Emirates
May-15-14
Supplier From Busan, South Korea (Republic Of Korea)
 
Weight Measurement Function: By Hours, minutes and seconds unit, Display the status of the usage of liquid gas and it can be used being installed on storage tank or tank lorry and can be carried as a portable measuring instrument.
PC Monitoring Function: As the remained liquid goes below 10% of its capacity, it automatically alarms to supplement liquid gas. Thus, the appropriate time for supplement of liquid gas can be decided on time.
Alarm Function: the liquid remaining of the storage tank is less than 10%, The alarm sound provides information that you can setting the a liquid supply time.
Diversity Of Power Supply: Use the usual 220volt electric, in case of power outage, the built-in battery will supply the charged electricity, in addition built-in battery is operated and available for tank lorry using the car battery.

Option (Printer : additional purchase): Receipt Output Function; Portable thermal transfer printer can use the output value measuring of storage tank and tank lorry without visiting a long measuring place directly by the output as a receipt.
Mar-09-10
 
Xl5135v-1 ac220v power supply--measuring dc voltage--voltmeter

Technical index:

Digit display: 1999

Operating temperature:0~40

Relative humidity:20%~80%

Power supply:ac220v

Installation method:inlay

Tapping size:76 x 39 (mm)

Dimension: (w) 79mm x (h) 42.5mm x (d) 25.5mm

Resolution: 10mv

Input impedance: 100mª+

Max. Input voltage:ía10v

Full range:ía199.9mv.
Mar-05-09
 
1.General
PZ96 Series power analyzer specializes in measuring the data of all kinds of AC networks, such as the currents, the voltages, the powers, the energies etc... It may be used for local display, or it is connected with the control equipment in measuring and controlling system.
They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication with Modbus-RTU protocol; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely
They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system.

2.Technical feature
- Input
Network: Single-phase network; 3-phase balanced network, 3-phase unbalanced, 3 wires; 3-phase unbalanced, 4 wires
Measurable: 26 parameters (3I, 6U, F, 4P, 4Q, 4cos, 4E)
Frequency: 45í½65Hz
Voltage: AC 100V, 400V (programmable); Overload: 480V (continuous), 800V/30s; Consumption: < 0.2VA
Current: AC 1A, 5A (programmable); Overload: 6A (continuous), 50A/30s; Consumption: < 0.2VA
Thermal drift: <200ppm
Transformation ratio: Programmable
- Power supply: AC/DC 85í½270V; Consumption í_ 4VA
- Test voltage: 2kVAC/min (voltage input / power; between current inputs); 1.5kVAC/min (outputs / power)
- Insulation: input / housing and output / housing >100Mª+
- Environment
Work T: -10Cí½+45C
Storage T: -20Cí½+70C
Relative humidity: 5%í½95% (no condensation)
Altitude: í_2500m

3.Options
- Display (L): LED or LCD display, the brightness can be set
- Communication (/C): RS485 (Modbus-RTU); 1 start bit, 8 data bit, 1 stop bit, no parity, speed
(1200/2400/4800/9600/19200)
- Alarm output(/J): 1 passive relay (1A/30VDC, 1A/250VAC); alarms of over voltage, low voltage and over current;
The hysteresis and the delay can be set
- Analog output(/M): DC4~20mA, DC0~20mA( load < 600ª+), DC0~5V,DC1~5V( load > 1kª+); Number: /M, /M3 (1 or 3
analog outputs)
- Logic options(/K)
4 logic inputs and 2 logic outputs
Logic Input: dry contact Input, supplied inside, optoisolator
Logic output: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments)
- Accuracy: 0.2
Note: /M and /K can not be chosen simultanously.

4. Specification
96 * 96 mm
PZ96-E3 3 Phase LED
PZ96L-E3 3 Phase LCD

72 * 72 mm
PZ72-E Single Phase LED
PZ72L-E Single Phase LCD

80 * 80 mm
PZ80-E Single Phase LED
PZ80-E3 3 Phase LED
PZ80L-E Single Phase LED
PZ80L-E3 3 Phase LCD

120 * 120 mm
PZ42-E3 3 Phase LED
PZ42L-E3 3 Phase LCD

144 * 144 mm
PZ144-E3 3 Phase LED
Jan-28-09

Digital Ph-Meter

$200
MOQ: Not Specified
Supplier From Mumbai, Maharashtra, India
 
The product is used to measure the pH of given aqueous sample.The Range is from 0pH to 14pH.It is given with automatic temperature sensor.