Please click here to check who's online and chat with them.

Pansani Imp.

Supplier From United States
Sep-27-07
Supplier : Eletronics

Verification Status



Contact Details:
1105 W Boylson St
# 3
MA 01606
Worcester United States


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Pansani Imp.

Jul-26-16
 
I product features
Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life.
Adopt unique pulse deduct technology to achieve overload protection.
Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network.
Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable.
Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use.
Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f)


Ii technical parameters
Lamp watts: 70w high pressure sodium lamp
Input voltage frequency: 50/60hz
Input voltage range: 160-260v ac
Input current: 0.35a
Power factor: >0.99
Total harmonic current distortion: =8%
Short circuit protection yes
Open circuit protection yes
Overheating protection yes
Lamp failure protection yes
Temperature range : - 30 ? ~ + 50 ?
Size (l * w* h) 148 x 77 x 51.2 mm

Iii: standards and certification:
Safety en61347-2-12
Emi en61000-3-2
Ems cisper15.Ed7.2
Quality standard iso9001
Environmental standards iso1400
Related certification ce/ccc
Sep-24-02
May-31-05
Supplier From Johannesburg, Gautend, South Africa
Apr-15-06
Aug-06-08
 
Dimmable electronic ballasts

Fl 2x35/220-240v t5 dim-a
Dimming range from 1-100%
Lamp start at 1% possible
Standard dc1-10v control interface
(en60929 with earth leakage 0.5ma)
Defined lamp friendly warm start within
1.5 s with ac and 0.6s with dc
Dc operation in emergency lighting
Installations to vde0108
Safe shutdown of defective lamps
Safe shutdown of lamps at end of life
Automatic restart after lamp replacement
Operating frequency ~40-120khz


Carton
Jul-26-16
 
I product features:
 using unique pulse phase modulation method eliminate tubes acoustic oscillation 
 to ensure the safety of tubes, prolong services life.
 
 adopt unique pulse deduct technology to achieve overload protection.


 its consumption is low, the efficiency is as high as 96%; the power factor above 0.99,
 low total harmonic current distortion, less impact on power network.


 wide working voltage range: ac 90v~260v, which can guarantee the output power constant
 when the input power voltage is unstable.


 perfect protection function, such as built-in overvoltage, undervoltage, output short circuit,
 open circuit, which can protect automatically for safe use.


 low temperature rise, it is suitable for wide range environment temperature: -30ºc to +50ºc(-22~+122f)


Ii technical parameters

Lamp watts:      400w high pressure sodium lamp
Voltage frequency:     50/60hz
Input voltage range:  160-260v  ac
Power factor:   >0.99
Wave crest ratio: =1.7
Short circuit           yes
Open circuit            yes
Over-temperature      yes
Lamp failure            yes
Temperature range :          - 30 ºc ~ + 50 ºc
Size (l * w* h)           197 x 106 x 63 mm


Iii: standards and certification:
Safety                            en61347-2-12
Emi                                en61000-3-2
Ems                               cisper15.Ed7.2
Quality standard               iso9001
Environmental standards    iso1400 
Related certification          ce/ccc
Jul-26-16
 
I product features:
Using unique pulse phase modulation method eliminate tubes acoustic oscillation
To ensure the safety of tubes, prolong services life.

Adopt unique pulse deduct technology to achieve overload protection.

Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99,
Low total harmonic current distortion, less impact on power network.

Wide working voltage range: ac 90v~260v, which can guarantee the output power constant
When the input power voltage is unstable.

Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit,
Open circuit, which can protect automatically for safe use.

Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f)

Ii technical parameters

Lamp watts: 360w high pressure sodium lamp
Voltage frequency: 50/60hz
Input voltage range: 160-260v ac
Power factor: >0.99
Wave crest ratio: =1.7
Short circuit yes
Open circuit yes
Over-temperature yes
Lamp failure yes
Temperature range : - 30 ? ~ + 50 ?
Size (l * w* h) 197 x 106 x 63 mm


Iii: standards and certification:
Safety en61347-2-12
Emi en61000-3-2
Ems cisper15.Ed7.2
Quality standard iso9001
Environmental standards iso1400
Related certification ce/ccc
Jul-26-16
 
I product features
Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life.
Adopt unique pulse deduct technology to achieve overload protection.
Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network.
Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable.
Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use.
Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f)


Ii technical parameters
Lamp watts: 130w high pressure sodium lamp
Input voltage frequency: 50/60hz
Input voltage range: 160-260v ac
Input current: 0.65a
Power factor: >0.99
Total harmonic current distortion: =8%
Short circuit protection yes
Open circuit protection yes
Overheating protection yes
Lamp failure protection yes
Temperature range : - 30 ? ~ + 50 ?
Size (l * w* h) 148 x 77 x 51.2 mm

Iii: standards and certification:
Safety en61347-2-12
Emi en61000-3-2
Ems cisper15.Ed7.2
Quality standard iso9001
Environmental standards iso1400
Related certification ce/ccc
Jul-26-16
 
I product features
Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life.
Adopt unique pulse deduct technology to achieve overload protection.
Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network.
Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable.
Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use.
Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f)


Ii technical parameters
Lamp watts: 110w high pressure sodium lamp
Input voltage frequency: 50/60hz
Input voltage range: 160-260v ac
Input current: 0.54a
Power factor: >0.99
Total harmonic current distortion: =8%
Short circuit protection yes
Open circuit protection yes
Overheating protection yes
Lamp failure protection yes
Temperature range : - 30 ? ~ + 50 ?
Size (l * w* h) 148 x 77 x 51.2 mm

Iii: standards and certification:
Safety en61347-2-12
Emi en61000-3-2
Ems cisper15.Ed7.2
Quality standard iso9001
Environmental standards iso1400
Related certification ce/ccc

Verification Status