1. Measurement range: co: 0-10.0 10-2(%)
Co2 : 0-20.0 10-2 (%)
Hc: 0-10000 10-6 (ppm)
O2 : 0-25.0 10-2 (%)
No: 0-5000 10-6(ppm)
Petrol temperature: 18f¦-150f¦
Engine speed: 100-20000rpm
2. Repetitiveness: f_f+2%
3. Zero point floating: co:f+0.06 10-2(%)/1h
Co2: f+0.5 10-2(%)/1h
Hc:f+30 10-6(ppm)/1h
O2: f+0.5 10-2(%)/1h
No: f+30 10-6(ppm)/1h
4. Crossing floating: not over the permitted indicated error range (1hour)
5. Indicated error: co: f+5%(relative error: 0-10%)
Co2: f+5%(relative error: 0-20%)
Hc:f+5%(relative error: 0-4000ppm) f+10%(relative error: 4001-10000ppm)
O2: f+5%(relative error: 0-25%)
No: f+5%(relative error: 0-5000ppm)
6. Environmental condition: petrol temperature: f+2f¦(relative error)
Engine speed: f+1.0%(relative error)
Temperature: 0f¦-40f¦
Humidity: f_80%
Atmospheric pressure: 60-105kpa
Power: ac 220vf+10%, 50hzf+1hz
7. Preheat time: 10 minutes
8. Method of sample taking:
Tail gas: taking directly, and the length of sample pipe and probe are 5m and 900mm
Petrol temperature: put the probe into the hole of lubricating oil gauge of engine, and the length of probing is the length of oil gauge. Then seal it with stopper in order to avoid the leakage of oil. The pipe length is 5m
Engine speed: the result is available at the point no more than 20cm from the high voltage coil of engine
9. Display method: lcd large screen display
10. Optional configuration: gas temperature and engine speed
11. Main features: built-in printer, and computer network communications, 30 minutes automatically suggest zero. Idle and idle-two measurement methods, plates imported functional group can store 500 measurements, natural gas, liquefied petroleum gas and petrol fuel three choices.
1. Measurement range: non-transparence n: 0-99.9%;
Ray absorption coefficient k: 0-16.06m-1;
Petrol temperature: 0¦-150¦;
Engine speed: 100-20000rpm;
2. Resolution: non-transparence n 0.1%;
Ray absorption coefficient k 0.01m-1;
Petrol temperature: 1%;
Engine speed: 1rpm;
3. Indicated error: non-transparence n:+2.0%(absolute error);
Petrol temperature:+ 2¦(absolute error);
Engine speed:+ 30rpm (absolute error);
4. Power: ac220v+10% ; 50hz+1hz;
5. Weight: control unit: 5kg(include printer);
Test unit: 7.5kg;
6. Effective optical path length: 215mm+0.1mm;
7. Preheat time: 15 minutes;
8. Method of sample taking:
Smoke: taking directly, and the length of sample pipe is 2m.
Petrol temperature: put the probe into the hole of lubricating oil gauge of engine, and the length of probing is the length of oil gauge. Then seal it with stopper in order to avoid the leakage of oil. The pipe length is 5m.
Engine speed: speed folder will be fixed on the engine nozzle can be tightened
9. Display method: lcd large screen display
10. Optional configuration: gas temperature and engine speed;
11. Main functions: built-in printer, and computer network communications. Number plate input feature can be stored to 500 measurements, k-value exceeding alarm.
1. Measurement range: 0-10(rb)
2. Effective diameter of filter paper: ¦ª32mm
3. Time for air bleed: 1.4f+ 0.2s
4. Quantity of air bleed: 330 f+15ml
5. Resolution: 0.01(rb)
6. Indicated error: no more than f+3% of the full stroke
7. Repetitiveness: no more than f+2% of the full stroke
8. Stability: continuous working within 3h, with floating quantity no more than f+3% of the full stroke
9. Power: ac 220v f+10%, 50hzf+1hz
10. Method of air bleed: air bleed by electricity
11. Display method: lcd large screen display;
12. Main features: connect with outer printer and computer;
Auto alarm for lack of paper;
Auto paper pass, test, reset and clean.
Brief introduction:
Sv-2lb semi-automatic smoke meter has a high light led screen with light conduction controlling. The average data after three times' test can be displayed, and the equipment can be connected with computer through rs-232 plug. Function of automatic air bleed made the compressed air is not in need.
-n main technical feature:
1. Measurement range: 0-10(rb)
2. Effective diameter of filter paper: ¦ª32mm
3. Time for air bleed: 1.4 f+0.2s
4. Quantity of air bleed: 330 f+15ml
5. Resolution: 0.1(rb)
6. Indicated error: no more than f+3% of the full stroke
7. Repetitiveness: no more than f+2% of the full stroke
8. Stability: continuous working within 3h, with floating quantity no more than f+3% of the full stroke
9. Environment condition: temperature: 0f¦ -40f¦
Relative humidity: 20% -80%
Atmospheric pressure: 70-105kpa
Power: ac220v f+10%; 50hzf+1hz
10. Method of air bleed: air bleed by electricity
11. Display method: led high light display
12. Main features: connect with computer
Supplier: Industrial safety (ppe), height safety, fire detection & protection system, gas detection system and building management system (bms) product.
"Total Weight - 1.3 KG
Diameter - 146mm
Activation Time - Approx 10 seconds
Warning Sound - 120 - 140 dBA
Fire Extinguish for an area - 3 Cubic Meters"
Key Specifications :
Work on all types of fire
Automatically activates upon contact with flames
Simple to use, no training required
Ideal for homes, offices, hotel, industrial settings
provides fast and reliable fire safety
No maintenance cost required for Agni Kawach fire extinguisher ball."
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.!
Features & Benefits:
1. Designed for sprinkler standards NFPA 13, 15 and 16.
2. Dual hazard operation.
3. Cross-zone (double-interlock) capability.
4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
5. Optional Digital Alarm Communicators