Please click here to check who's online and chat with them.

Liaoyang Sunny Pharmaceutical Machinery Co.Ltd

Supplier From China
Oct-23-06
Supplier : Tubular centrifuges, cup type precipitation centrifuges, 3-point setting centrifuges, 3-point filtering centrifuges and various centrifugal equipment

Established: 1988

Verification Status



Contact Details:
No12-5Western Fifth Street Liayang
Liaoyang 111000
Liaoning China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Liaoyang Sunny Pharmaceutical Machinery Co.Ltd

Jun-20-05
 
Ss 3-point filter centrifuge
1.The machine can be used for filtering solid granular suspension, for dehydration suspension, for dehydration of fiber material and textile after dyeing and washing.
2.Feed material from thetop.
3. Low speed starting and high speed separation, enabling the drum to set up centrifugal force field.
4.The liquid can be drained off from liquid outlet in the bottom. The solid phase can be chained off from the top after the machine stops.
Main features
1 the structure is simple, it is convenient for operation and maintenance.
2 its generality of usage si very great.
3 all parts in contact with the material are made of stainless in order to prevent pollution.
4 the hand brake can shorten the working period.
5 it can be used as rough separation equipment in the first process of the tubular separator.

Standard
GOLD Member
May-16-21
Supplier From Saint-Paul, France
 
Measuring Range - 0-100%
Range of Precision - 70-10%
Measuring Precision - 2%
Resolution - 1%
Data update time - 1s

Pulse Rate

Measuring Range - 18-250bpm
Range of Precision - 25-250bpm
Measuring Precision - 3bpm
Resolution - 1bpm
Data update time - 1s

Packing Information

Working Size - 7cm*3cm*2.4cm
Packing Size - 40cm*37cm*24cm
N.W. - 0.075kg
G.W - 0.15kg
GOLD Member
May-16-21
Supplier From Saint-Paul, France
 
FINGERTIP PULSE OXIMETER

Parameters:

Two parameters:SPO2, Pulse Rate.



Waveforms:

SpO2 Waveform.



Features:

1 COLOR OLED display, four direction adjustable.

2 SpO2 and pulse monitoring, and Waveform display.

3 With menu operation.

4 With beep and alarm.

5 Low-power consumption, continuously work for 50 hours.

6 Small in size, light in weight, and convenient to carry.

7 Low voltage alarm display, Auto power-off.

8 Runs on standard AAA batteries.

Detailed descriptions of product functions:

SPO2:

1 Measurement range: 70%-99%

2 Accuracy: �±2% on the stage of 70%-99%, unspecified(<70%) for SPO2

3 Resolution: �±1%

4 Low perfusion: <0.4%

PR:

1 Measurement: range:30BPM-240BPM

2 Accuracy: �±1BPM or �±1%(the larger one)

3 Power: two AAA 1.5V alkaline batteries

4 Power consumption: below 30mA

5 Automatic power-off: the product shuts down automatically after no signal for 8 seconds
GOLD Member
May-17-21
 
Technique Parameter

Oxygen flow rate .. 1L-5L
Oxygen concentration .. 93% + 3%
Rated voltage / Power .. AC220+V 22V ,50Hz + 1Hz
Material .. Plastic
Oxygen concentration .. 0.5-3L/min + 90%
Flow fluctuation .. 0.7L/min
Atomization amount .. + 0.2ml/min
environment temperature .. 5-40
humidity range .. 80%
Atmospheric pressure range .86kpa -- 106kpa
Size .. L448*W245*H492
Weight .. 14.5g


1. Headset type components (optional)
2. Nasal tube assembly (optional)
3. Atomizer assembly
GOLD Member
May-16-21
 
Technique Parameter

Oxygen flow rate .. 1L-5L
Oxygen concentration .. 93% + 3%
Rated voltage / Power .. AC220V + 22V ,50Hz + 1Hz
Material .. Plastic
Oxygen concentration .. 0.5-3L/min 90%
Flow fluctuation .. 0.7L/min
Atomization amount .. 0.2ml/min
environment temperature .. 5-40
humidity range .. 80%
Atmospheric pressure range .. 86kpa -- 106kpa
Size .. L448*W245*H492
Weight .. 14.5g

1. Headset type components (optional)
2. Nasal tube assembly (optional)
3. Atomizer assembly
GOLD Member
VERIFIED
Oct-12-21
Buyer From Aurangabad, Maharashtra, India
GOLD Member
Aug-16-22
 
Wrist Splint (Tubular Type) AJY-S07

For wrist or distal forearm fractures, functional fixation of wrist arthroplasty, and rest for wrist arthritis and other lesions

Position immobilization or lunate dislocation colles fracture fixation.

300*280*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy
GOLD Member
Aug-16-22
 
Thumb plate (tubular type) AJY-S03

For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation.

210*145*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy
GOLD Member
Aug-16-22
 
Elbow Joint Splint (AJY-S12)

It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint.

448*260*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy

Verification Status