Volume: 0402, 0603, 0805, 1206, 1210
Unit: H, NH, UH, MH
Error: ±5%, ±10%
Packing: 4000PCS/reel, 3000PCS/reel above 1206
Current: the difference between small current and large current, unit A (A)
The SMD inductors in our inventory have complete specifications:
The conventional models are complete, including: chip beads, high current chip inductors, chip power inductors, high frequency inductors, chip winding inductors, laminated inductors, common mode inductors, shielded inductors, I-shaped inductors, etc.; Conventional inductance, rated current and other parameter products are available in stock.
The role of chip inductors:
1. Filtering
It can be used for power supply filtering because it has the characteristics of DC and AC resistance;
2. Resonance
It can form a resonant frequency selective circuit with a capacitor, and the resonant frequency is determined by the size of the chip inductance and capacitor;
3. Frequency division
Can be used for frequency division of high and low frequency signals
Application areas of chip inductors: Internet of Things products, smart products, Internet products, communication products, 3D printers, etc.
Item Specifics:
Model: PIM1030R12MZ
L0(uH)/inductance at 0A,100KH):Typ.:0.12
DCR (mª+)at 25ípC:Typ.0.65/Max:0.75
Irated(Adc)/Heat RatingCurrent :Typ.:30
Isat(Adc)/Saturation Current:Typ.:75
Available L0(uH):From 0.12 to 10.00
Molded Power Inductor
Operating temperature : -55íµ ~ +125íµ
Ambient Temperature, Maximum : 85íµ
Temperature Rise, Maximum: 40íµ
Features
Low profile, high current SMD type. Lowest DCR/µH, in this package size, low buzz noise due to its gap-less structure, RoHS compliant.
Frequency range up to 5MHz.
Lowest DCR/µH, in this package size
Low buzz noise due to its gap-less structure
RoHS compliant.
Applications
Notebook/Desktop/Server/Video Card applications.
High current POL converters.
Low profile, high current power supplies
Battery powered devices.
Ideal for power source circuits, DC-DC converter
DC-AC inverters inductor application.
Note:
1. L0 is inductance tested at 0 Adc.
2. Isat is the DC current which cause the inductance drop approximately 30% of its nominal inductance without current.
3. Irated is the DC current which cause the surface temperature of the part increase appproximately than 40íµ.
4. Operating Temperature Range: - 55íµ to +125íµ
5. The part temperature (ambient + temp rise ) should not exceed 125íµ under worse case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and other cooling provision all affect the part temperature. Part temperature should be verified in the end application.
6. The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Ef type high frequency transformer
-smd ift coils for tv receivers and am and fm radios
-variable inductor and coils with wide range of inductance
-designed for application in different types of circuits
-ift coils with internal capacitors
-smd ift coils for radio receivers and am and fm radios
-ift variable coils for wireless communication system and remotecontrol toy/equipment
-ift adjustable coils with wide range of inductance
-designed for application in different types of circuits
-ift coils with internal capacitors
-ec, ee.Ei and pq type high frequency switch transformer ep type magnet shielding switch transformer
-rm type communication filter, aux power transformer
-et, ft type linearity g (jar shape) switch transformer
-dr (i) type transformer t (ring) iron power core, dc filter inductorrm series: rm-4, 5, 6, 8, 10, 12, 14
Iso ul certification,
Welcome custom
Company with ul qualification
Original manufacturer
Iso 9001:2008
3-5pcs free samples
Short lead time
100% test before shipping
International standard specification
Professional packing
300k per month
Conform to ce, rohs, fcc
Oem/odm accepted
Range: 2500 kVA to 100,000 kVA, up to 220 kV Class
Standards:
The power transformers are designed and tested to the following standards:
Power transformers: IS: 2026, BS: 171 & IEC: 76
Converter transformers: IS: 4540, IEC: 146 & IEEE: 444
Furnace transformers: IS: 2026
System earthing transformers: IS: 3150 & BS: 4944
We are capable in supplying the transformers to any other standards as per customers'/consultants' requirements.
Range: 2500 kVA to 100,000 kVA, up to 220 kV Class
Standards:
The power transformers are designed and tested to the following standards:
Power transformers: IS: 2026, BS: 171 & IEC: 76
Converter transformers: IS: 4540, IEC: 146 & IEEE: 444
Furnace transformers: IS: 2026
System earthing transformers: IS: 3150 & BS: 4944
We are capable in supplying the transformers to any other standards as per customers'/consultants' requirements.
We are instrumental in trading and supplying an exclusive assortment of Power Transformers. These transformers are procured from some of the trustworthy and certified vendors of the industry who manufacture these in compliance with the international standards. Our offered transformers are used extensively in electronic products to step down the supply voltage to a level suitable for the low voltage circuits they contain. This range also electrically isolates the end user from contact with the supply voltage.
Specifications:
Power transformers from 1 MVA to 50 MVA up to 220KV Class