Place of Origin Guangdong, China
Purpose for replace/repair
Condition New
Model Number RDD1000
Brand Name RAWSUNS
Product Name EV conversion kit RDD1000 Direct drive motor + motor controller
application 4.5-8T truck /6M bus
Motor Type PMSM
IP Grade 67
Motor Rated (Kw) 90
Motor Peak (Kw) 172
Rated Torque (Nm) 450
Peak Torque (Nm) 1000
Rated Speed(rpm) 1910
Peak Speed (rpm) 4500
Warranty: 1 year
Model Number: RSEV-EVCU-2VT-01
Dimensions: 206.6 149.1 28.6mm
Weight: 11.5 kg
Working voltage: 9-18 (12V) 9-36 (24v)
Static Power: 1.2 mA
IP Grade: IP67
Analog input: 3 Channels
Digital input high effective: 7 Channels
Digital input low effective: 5 Channels
Digital input: 8/10 Channels
CAN Channel: 2 Channels
Place of Origin:Guangdong, China
Brand Name:rawsuns
Model Number:RDD2800 motor and inverter
Type:Synchronous Motor
Phase:three-phase
Certification:ce
Protect Feature:IP67
AC Voltage:336/540/576VDC
Efficiency:90%
rated power:100kw
peak power:200kw
rated torque:1200Nm
peak torque:2800Nm
max speed:2600rpm
Warranty: 12 months
Certification: CE
Place of Origin: Guangdong, China
Brand Name: Rawsuns
Model Number: RMC60
Product name: Rawsuns RMC60 60kw Motor Controller for Electric Cars/Trucks/Vehicles
high volt input range: 250-420VDC
peak efficiency: 99%
IP grade: 67
low volt input range: 9-30VDC
Dimensions: 380*280*98mm
Maximum working alitude: 3500m
Max output current peak: 320Arms
Warranty: 12 months
Certification: ce
Place of Origin: Guangdong, China
Brand Name: rawsun
Model Number: RMC120
Peak power: 120kw
Rated Power: 80KW
Max output continuous current: 200A
High volt input range: 260-720 VDC
Cooling type: Water cooled
Weight: 11.5Kg
Max output peak current: 400A
Low volt input range: 9-32 VDC
Peak efficiency: 97%
Dimension: 380mm*280mm*98mm
Power input Rated voltage 3-phase AC220V/AC230V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V
1-phase
AC220V/AC230V
Rated input current See Section 2.3 in user manual
Frequency 50Hz/60Hz, acceptable fluctuation range ¡¨¤5%
Allowable range of voltage Continuous voltage fluctuation ¡¨¤10%, short fluctuation -15%~+10%, i.e. 323V~528V;
Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC61800-2
Power output Standard applicable motor (kW) See Section 2.3 in user manual
Rated current (A) See Section 2.3 in user manual
Output voltage (V) 3-phase: 0~ rated input voltage, Bias < ¡¨¤3%
Output frequency (Hz) 0.00~ 600.00Hz; unit: 0.01Hz
Overload capacity 150% - 1min; 180% - 10s; 200% - 0.5s once per 10 minutes
Operation characteristics Control mode V/f control
Sensor-less vector control without PG 1
Sensor-less vector control without PG 2
Range of speed regulation 1:100 ( V/f control, sensor-less vector control without PG 1)
1:200 (sensor-less vector control without PG 2)
Speed accuracy ¡¨¤0.5% (V/f control)
¡¨¤0.2% (sensor-less vector control without PG 1 & 2)
Speed fluctuation ¡¨¤0.3% (sensor-less vector control without PG 1 & 2)
Torque response < 10ms (sensor-less vector control without PG 1 & 2)
Starting torque 0.5Hz: 180% (V/f control, sensor-less vector control without PG 1)
0.25Hz: 180% (sensor-less vector control without PG 2)
Basic functions Start frequency 0.00~ 600.00Hz
Acceleration/deceleration time 0.00~60000s
Carrier frequency 0.7kHz~16kHz
Frequency command source Digital command + operating panel ¡Ä/¡Å
Digital command + terminal UP/DOWN
Communication
Analog command (AI1/AI2/EAI)
Terminal pulse command
Motor Started method Started from starting frequency
DC braking and then started
Speed search then started smoothly
Motor Stopped method Ramp to stop
Coast to stop
Ramp stop + DC brake
Basic functions Dynamic brake capacity Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake unit for GK600-4T45G/55L or below could be internally mounted
DC brake capacity DC brake start frequency: 0.00~600.00Hz
DC brake current: 0.0~100.0%
DC brake time: 0.0~30.00s
Input terminals Six digital input terminals (can be extended to 7), one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input
Two analog input terminals, one of which is voltage/current programmable, and the other is voltage only (can be extended to 3; extension terminal is voltage/current programmable)
Output terminal One high-speed pulse output terminal, 0~50kHz square wave signal output; can output signals such as setting frequency and output frequency. etc
One digital output terminal
One relay output terminal (can be extended to 2)
One analog output terminal (can be extended to 2), voltage/current output optional; can output signals such as setting frequency and output frequency, etc
Characteristics Parameter copy, parameter backup, common DC bus, free switching between two motors¡¡¥ parameters, flexible function code displayed & hidden, various main & auxiliary command and switchover, speed searching, a variety of acceleration/deceleration curves optional, automatic correction of analog value, mechanical brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), swing frequency control programmable, fixed-length control, counting function, three faults recorded, over excitation braking, over voltage stall prevention, under voltage stall prevention, restart upon power off, hopping frequency, frequency binding, free switching between four sections of acceleration/deceleration time, motor thermal protection, flexible fan control, process PID control, simple PLC, flexible multi-functional key setting, droop control, parameter identification, weak magnetic control, high-precision torque restraint, V/f separated control
Protection function Refer to Chapter VII - Fault Diagnosis and Abnormity Handling
Environment Place of operation Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drip or salt content etc.
Altitude 0~2000m
Derating is required where altitude is more than 1,000m; each increase of 100m in height corresponds to a decrease in rated output current by 1%
Ambient temperature -10¡ãC~50¡ãC
Humidity 5~95%, condensation not allowed
Vibration Less than 5.9m/s2 (0.6g)
Storage temperature -40¡ãC~+70¡ãC
Others
Efficiency Rated power
7.5kW and below: ¡Y93%
11~ 45kW: ¡Y 95% 55kW and higher: ¡Y98%
Installation mode Wall-mounted
Protection level IP20
Cooling mode Forced air cooling
Country of Origin: China (Mainland) Guangdong
Brand: GTAKE
Model: as type
Output power: other
0.4KW-800KW
Output type: Triple
Size: as model
Weight: as model
Input voltage :208V/220V/230V/380V/400V/415V/440V/460V/480V
Output: 0-rated input voltage
Type: AC/AC, or DC/AC inverters
Output frequency: 0.00-600.00Hz
Output current: as model
Input terminals: DI-7(HDI-1), AI-3 0~10V, or 0-20mA
Output terminals: DO-2(HDO-1), RO-2, AO-2
Certificate: CE, GOST
Applying motor: Asynchronous motor and synchronous motor
Cooling: Air cooling
IP grade: IP20
Input voltage: AC, or DC
Frequency command source:Keypad, terminals, communication
Communication: Modbus, Profibus-DP, CANopen, CAN
Control technique: V/f, SVC1, SVC2
Stepper motor drive
-Bipolar Motor Drive
-Microprocessor based Design
-Operating Voltage up to 80V DC
-Programmable Motor current up to 8A
-Up to 64 Microsteps - Selectable through DIP Switch
-Microstepping for Smooth Operation