Supplier: Electrical materials: wire, meter stacks, main disconnects, switchgear, panelboards, transformers, conduit, etc. Services: Broker Buyer: Electrical materials: wire, meter stacks, main disconnects, switchgear, panelboards, transformers, conduit, etc.
Supplier: Single phase & three phase distribution transformers, power transformers, dry type ct pt (current transformer potential transformer), electric meters, drop out fuses & lightning arresters, high tension switchgear & substation equipment, spun prestressed concrete (spc) poles amongst other varieties of elements of a distribution grid. Buyer: Copper wire scrap
SME series Metal Enclosed Switchgears are defined with followwing features
2 mm sheet steel
LSC 2A Loss of Service Continuity
Pl Partition Class
AFL Internal Arc Classification
3 earted accessible compartmments
Maximum personel safety with up to 25 kA / 1s internal arc test
Safety electrical and mechanical Interlocking systems
SF6 gas insulated Circuit Breaker allows fast and easy servicing
Grounding systems with ensured continuity.
General Production Range and Specifications
Rated Voltage : 3.640.5 kV
Power Frequency withstand Voltage : 1085 kV
Lighting Impulse withstand Voltage : 40185 kV
Rated Frequency : 50 / 60 Hz
Rated Current : 6301250 A
Short time withstand current : 16/20/25 kA ( 1 sec )
Internal Arc withstand Current: 16/20/25 kA ( 1 sec ).
LMZ designs the best proper Mobile Substation by analyzing customer requirements, site and transportation conditions.
SETAS Mobile Substations are used for military camps, industrial facilities, distribution networks, emergency power demands and additional power requests.
Mobile Substation General Specifications:
HV switching equipments can be gas ORA IR insulated
Trailer / Platform / Wagon / Vessel type applications
Up to IP 56 Protection Class
Entire substation can be deliver being ready to use in a SCADA system
Shorter manufacturing time compare to fixed type.
Ideal solution for emergency power demand, temporary services and new services
Production is made according to IEC 62271-202, 200, standards, different standards can also be applied on demand.
Metal Clad Switchgears
SETAS Metal Clad Switchgears are switching and control cubicles manufactured between 1 kV 40.5 kV comply with IEC 62271-200 standards.
SMC series Metal Clad Switchgears are defined with following features according to IEC 62271-200 standards.
3mm sheet steels
LSC 2B class Loss of Service Continuity
Pm Partition Class
AFLR Internal Arc Classification
4 earthed accessible compartments
Maximum personnel safety with 31.5 kA/ 1 s internal arc test.
Safety electrical and mechanical Interlocking systems.
Withdrawable type Vacuum / SF6 Circuit Breaker for fast and easy servicing
General Production Range and Specifications
Rated Voltage : 3.640.5 kV
Power Frequency withstand Voltage : 1085 kV
Lightening Impulse withstand Voltage : 40185 kV
Rated Frequency : 50/60 Hz
Rated Current ( natural ventilation ) : 6303150 A
Short Circuit withstand Current : 1631.5 kA ( 3 s )
Internal Arc withstand Current : 1631.5 kA ( 1 s ).