Please click here to check who's online and chat with them.

Guangzhou Sunho Testing Equipment Co., Ltd.

Supplier From China
Dec-15-21
Supplier : Testing equipment, laboratorial set up solutions, customized/standardized services

Established: 2003

Verification Status



Contact Details:
No.101 Block F, Fengsheng Indsutrial Park, Shibei Industrial Avenue, Panyu District
Guangzhou 511430
China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Guangzhou Sunho Testing Equipment Co., Ltd.

GOLD Member
May-21-25
Buyer From Chennai, Tamil Nadu, India
VERIFIED
Mar-25-13
Supplier From Banaglore, Karnataka, India
VERIFIED
Aug-14-20
Supplier From Vadodara, Gujarat, India
Dec-04-09
 
Manual operation to microprocessor operated testers from 0-60kV, 0-80kV, 0-90kV and 0-100kV.
VERIFIED
Mar-07-14
Supplier From Guangzhou, Guangdong, China
VERIFIED
Sep-10-20
Supplier From Vancouver, BC, Canada
Feb-02-22
 
1.It's used for safety testing of lithium battery protection boards.
2.Quick testing, precise testing and laboratory mode.
3.you can protect Internal resistance test, overcharge and over discharge test, short circuit protection test etc..
4.Type of protection board - Lithium iron phosphate, ternary lithium cobaltate, lithium manganate and lithium titanate.
5. Support the bar code scanning function and automatically save the test data.
Jul-14-11
 
Overview:
The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA.
3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range.
4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum).
5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã.
6. Frequency:45Hz~65Hz,Resolution:0.01Hz.
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%
9. Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions). If necessary, the maximum load can be extended to Current:1,800VA and Voltage:1,000VA.
10. Harmonic wave output: 2-21st sub-harmonic wave, content<40%; 3rd,5th and 7th superposed sub-harmonic wave, content<10% each;Control of conduction angle(odd sub-harmonic wave);Control of wave group(sub-harmonic wave).
11. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
12. Starting current output:5mA(minimum); Accuracy:5%;Starting power: Accuracy 5%
13. Energy meter testing positions:24/48 standard ;3 to 60 meter positions also available
14. Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing, Dial testing and etc.
15. Input power supply:220VAC,¡À10%,50Hz. Max power consumption:1,500VA(24 meter testing positions).
16. Tests: Demand test; Frequency impact test; Voltage impact test; Second pulse clock precision test; GPS clock synchronization; Constant calibration; Combined error test; Various register checking;RS485 communication port test.

Dimension:
Integral Type
24 Meter testing positions(1 rack): 2200*750*1920mm
48 Meter testing positions(2 racks): 2200*750*1920mm.
Jul-14-11
 
Overview:

The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.

Verification Status