Adding strength to the bond of PVC pipes and fittings, S-lon Solvent Cement brings superior bonds, providing for a vital link in your PVC pipe installations.
Place of Origin:Sri Lanka
Product Classification: Volatile Solvent Adhesives
Usage: Construction and Plumbing, For bonding PVC-U pipes and fittings in non-pressure applications
Material: PVC Resin with Solvent
Certificate: SLS 935:1991 / BSEN 681/ASTM D 2564
Appearance: Even , Continuous and free of lumps and foreign matter
Package: Bottles of 500g,250g,125g,75g,50g,25g
Storage: Store in a cool dry place and out of direct sunlight
Appearance/ colour : liquid/ pale yellow.
Specific gravity at 230 c 0.94(+ 0.03).
Viscosity ford cup 4 sec's : 70 (+ 5)
Solid content % : 20 (+ 4)
Cementing /cure time hrs : 2.5 to 3.5
Service temperature deg.C : (-)10 to (+)85
Applications : for use with pvc conduit, drain, waste and vent pipe up to 4" diameter.
Tin containers of 125ml, 250ml, 500ml & 1 ltr only.
For the diverse requirements of our clients, we offer an effective grade of CPVC Solvent Cement that is extensively used for sealing for cold water pipe line. Under the direction of our chemical experts, the offered cement is precisely processed utilizing optimum quality chemical compounds that ensure fast sealing. Our offered cement is stringently tested against various quality parameters to assure its long shelf life.
Features:
Fast drying with high solid content
High viscosity
Good heat resistance
Better stability at high and low temperature
Benefits:
No dripping and wastage in application
Excellent gap filling ability hence highly suitable for interference & non- interference fit pipe & socket
High bond strength
Pipe can be put to use fast
Suitable for cold water pipe line
Suitable for use in all climatic condition
Medium Bodied, Fast Setting, High Strength, Low VOC CPVC Cement
Designed for all grades and types of CPVC pipe and fittings
For Hot and Cold Potable water upto 82 Degree Celcius
Store Product Below 33 Degree Celcius
Nirmaan Pipes is one of the leading manufacturers of UPVC Fitiings in Eastern India. Nirmaan UPVC Fittings are manufactured in strict accordance to the standards of ASTM-D-2467 and are joined and installed with Nirmaan UPVC pipes manufactured according to ASTM-D-1785.
DIRECTIONS FOR USE:
- Shake well before using.
- Keep container closed when not in use.
- Set time is the time required before joint can safely be handled.
- Cure time is the time required before joint can be pressure tested.
1. Cut pipe square with saw or hand cutter. Remove all burrs.
2. Check dry fit of pipe and fitting. Pipe should easily go A1/A3 to A1/A2 way into fitting. If pipe bottoms into fitting it should be very snug.
3. Pipe and Fitting should be free of dirt, grease and other foreign materials. If necessary clean pipe and fitting using RPC-WELD Pipe Cleaner. Primer is highly recommended for 3 and larger diameter installation. Apply liberal coat. Primer will start softening surface of pipe and fitting thus ensuring superior joint.
4. Use applicator supplied with the can or suitable applicator at least A1/A2 the size of the pipe diameter.
5. Apply liberal coat of cement to the pipe (equal to depth of fitting) and adequate coat inside of fitting. Make sure there is no uncoated surface. Avoid puddling of cement, it may weaken the joint.
6. Immediately insert pipe into fitting with twisting motion. Cement should be wet. If it has dried recoat both parts. Use sufficient force to ensure pipe bottoms into fitting.
7. Hold joint together for 30-40 seconds to make sure pipe is not pushed out longer time if temperature is low and for larger pipes.
8. Allow 15 minutes set time before handling the assembly and 2 hours cure time if temperature is below 16 C or 60 F Longer cure time may be required for larger pipe and /or temperature is below 16 C or 60 F.
DIRECTIONS FOR USE:
Shake well before using.
Keep container closed when not in use.
Set time is the time required before joint can safely be handled.
Cure time is the time required before joint can be pressure tested.
1. Cut pipe square with saw or hand cutter. Remove all burrs.
2. Check dry fit of pipe and fitting. Pipe should easily go way into fitting. If pipe bottoms into fitting
it should be very snug.
3. Pipe and Fitting should be free of dirt, grease and other foreign materials. If necessary clean pipe and
fitting using RPC-WELD Pipe Cleaner. Primer is highly recommended for 3 and larger diameter installation.
Apply liberal coat. Primer will start softening surface of pipe and fitting thus ensuring superior joint.
4. Use applicator supplied with the can or suitable applicator at least the size of the pipe diameter
5. Apply liberal coat of cement to the pipe (equal to depth of fitting) and adequate coat inside of fitting.
Make sure there is no uncoated surface. Avoid puddling of cement, it may weaken the joint.
6. Immediately insert pipe into fitting with twisting motion. Cement should be wet. If it has dried recoat both parts.
Use sufficient force to ensure pipe bottoms into fitting.
7. Hold joint together for 30-40 seconds to make sure pipe is not pushed out longer time if temperature is low
and for larger pipes.
8. Allow 15 minutes set time before handling the assembly and 2 hours cure time if temperature is below 16 C or
60 F Longer cure time may be required for larger pipe and /or temperature is below 16 C or 6